Military Engineer Services Tender

View complete overview of Goa MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Mar 2025
Closing Date29 Mar 2025
Tender Amount₹ 42,85,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(i) Red/Green VCB ON-OFF Indication. (ii) AMBER : Trip Indication (iii) WHITE: Trip Circuit Healthy Indication with Push Button. (iv) BLUE : VCB Mechanism Spring charged Indication. (j) 11 kv, 350 MVA 800 Amps Three Phase busbars of aluminium with Rear cable termination ie, Provision for terminating 3 core 95 Sqmm, XLPE Cable. (k) 2 No. Strip heater- 100 W (continuously rated) with thermostat control for breaker/CT compartment with manual ON-OFF switch. (l) Structural steel frame including PCC foundation and earthwork as per manufacturer specifications. (m) 1 to 3 way breaker control switch with popsitions TRIP-NEUTRAL-CLOSE. (n) Manual charging/operating arrangement. (o) Fuses for metering and protection system.

-

-

-

... More
(p) (i) Auto trip. (ii) Motor/manual charged spring operating/closing mechanism. (iii) Fault alarm (iv) Manual tripping (q) All wiring necessary for the above including interconnection to trip coil. The wire should be FRLS type in all panels. (r) Test Terminal Block (TTB) to test meters and relays with sealing arrangement.

-

-

-

... More
NOTE:- 1. The HT panel comprising of VCB to be manufactured by OEM 2. Contractor shall produce manufacturer's test certificate for all routine and type test of VCB's 3. Rate quoted is deemed to be inclusive for above provisions and Civil works for foundation as per manual of manufacturer 4.Any spare/item required at site for functional of above VCB shall be done without any extra cost to the department 5.Auxillary supply voltage for thr Relay/Close/Trip coil 24 volt DC.

-

-

-

... More
Supply, laying, testing and commissioning XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, earthed electric power cables (Heavy duty) aluminium conductor 11 KV Earthed grade suitable earthed system cross sectional area 95 Sqmm, 3 core HT UG Cable laid in trenches/through GI pipe /fixed along with pole complete all as specified and as directed. Note:- a) Excavation and earth work shall be measured and paid seperately under relevant items of schedule b) High voltage test to be conducted at site with suitable voltage after laying of HT cable and reading to be recoreded jointly and test report to be submitted in triplicate,the cost of the same is deemed to be included in unit rate of subject item. (c) The HT cable route indicator as specified by Engr-in- Charge is also included in the rate quoted.

1710

-

-

... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying/taking out cable and getting out in soft/loose soil all as specified and as directed.

600

-

-

... More
Returning,filling in including spreading, levelling, watering and well ramming in layer not exceeding 25 cm in soft/loose soil all as specified and as directed.

550

-

-

... More
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and as directed.

50

-

-

... More
Supply and laying of flexible DWC pipe of nominal diameter 63 mm under the ground and drawing the XLPE cable through the DWC pipe complete all as specified and as directed.

1610

-

-

... More
Supply & Laying in repair GI tubing light grade with necessary fittings as in cable protection in trenches/fixed on wall / floor including necessary clamps bolts and nuts complete all as specified and as directed of sizes 80mm dia

10

-

-

... More
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm.

3

-

-

... More
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm

4

-

-

... More
M&L for earthing complete in repairs with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI strip of size 32 X 6 mm and 40 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009. Note :- All joints either strip to strip of strip to earth plate are fixed with welded joints.

6

-

-

... More
M & L for construction of Plinth of dimension 6 x 6 x 6 ft with foundation work providing PCC type B2 (1:3:6) with 40 mm graded for installing outdoor transformer of capacity 500 kVA.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.