Public Works Department Tender
... More
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Public Works Department - PWD Tender
Eprocure
Opening Date7 Dec 2019
Closing Date18 Dec 2019
Tender Amount₹ 95,58,272
Costs
EMD
₹ 1,91,165Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Annual Running Maint And Operation Of Street Light And High Mast Light I/c Monitoring Of Street Lights, Pumps And Ei Of Vrs Underpasses Rub, Subways And Underneath Of Flyover And Sewage/storm Water Pumps, Dg Sets At Vrs Location Under M-251, Delhi
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_PWD_185197_1Bid Award Id
ViewTender No
73/EE (E)/ PWD NE and Shah. Elect. Divn/19-20Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://www.pwddelhi.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
HPSV
-
-
-
... More
Providing and carrying out the comprehensive, routine, day to day & preventive including maintenance of street lights by using Tower Wagon, ladders,& all other relevant required for smooth, healthy & proper illumination on pwd (Annexure-C) roads complete with supplying and replacement (all rating) of all electrical accessories like Ballast, Lamp, igenitor and feeder pillar accessories like MCCB, Contactors, Relay, Bus Bar, timers, panel wiring, pole wiring cable, lugs, nuts and bolts etc and ensuring security thereof and to prevent theft of electricity from street light installation complete including daily inspection of roads, repairs and attending the complaints as and when required and submit daily inspection report to concern JE(E) / AE( E) and updating the inventory regularly ( including addition/removal of Poles/High mast poles/ Fittings/ Feeder pillars) and handing over the dismantled materials to JE at his store. 1261 Points as per inventory
Minimum Staff to be deployed at site for attending complaints
a) Wireman – 3 Nos. (on all days i/c Sunday and Holidays)
b) Khallasi – 3 Nos. (on all days i/c Sunday and Holidays)
12
-
176540
... More
Providing services of the qualified and experienced staff for monitoring & maintenance of Street light/ High Mast Fittings/ Feeder Pillars/Electrician fitting in under pass, Subways & various RUBs and FOB under North East Distt. i.e should be capable enough to perform repairs to poles, fixtures, cables, junction boxes,
feeder pillars and other associated accessories and should posses two wheeler for visiting the sites/Field whenever necessary or as per the instructions of Engineer-In- Charge on all days including Sunday and G. Holiday in two shifts (shift of the duty shall be decided by Engineer-in-Charge
1. Supervisor - 1 No. (B. Tech/Diploma holder (electrical) with 3 years of experience) on all days i/c Sunday and Holiday.
2. Wireman – 2 No. (on all days i/c Sunday and Holidays)
3. Khallasi – 2 No. (on all days i/c Sunday and Holidays)
12
-
115169
... More
Sub Head - II ( Materials)
-
-
-
... More
Supply of following materials which are to be used in case of theft (after registering FIR) shall be handed over to the Engineer-In-Charge and record of all the materials where replacement has been done has to be maintained and to be submitted to the Engineer-In-Charge every week. For 1 Year
-
-
-
... More
LED drivers suitable for CROMPTON/ WIPRO/ TRILUX/ SURYA/ PHILIPS fittings a) 250/200/160/120/80 Watts
100
-
1000
... More
HPSV Ballast (Make:- Havells/ Bajaj/ Crompton/ Phillips)
a) 400 Watts
25
-
1070
... More
b) 250 Watts
10
-
763
... More
c) 150 Watts
10
-
528
... More
HPSV lamp (Make:- Havell’s/ Bajaj/ Crompton/ Phillips)
a) 400 Watts
10
-
378
... More
b) 250 Watts
10
-
378
... More
c) 150 Watts
10
-
343
... More
Ignitor (Make:- Havell’s/ Bajaj/ Crompton/ Phillips)
a) 400/ 250/ 150 Watts
20
-
68
... More
Capacitor for HPSV Fittings (Make:- Havell’s/ Bajaj/ Crompton/ Phillips)
a) 20 Mfd
20
-
39
... More
b) 10 Mfd
10
-
29
... More
ML 4 Contactor 100 Amps (Make:- L&T)
10
-
6040
... More
Timers (L & T make)
10
-
1638
... More
MCCB & MCB
a) 250 A, 36kA, FPMCCB
5
-
12474
... More
b) 100 A, 30kA, FPMCCB
5
-
4500
... More
c) 100 A, 16 kA, TPMCCB
5
-
2656
... More
d) SP MCB's 6 A to 32 A ratings, SP MCB, “C” curve, 10 kA breaking capacity
10
-
117
... More
PVC insulated PVC sheathed copper conductor multicore cable in the existing poles from pole box to fittings complete etc. as required at site.
a) 3 X 4 Sq.mm
50
-
72
... More
b) 3 X 1.5 Sq.mm
50
-
29
... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
1000
-
135
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
a) Upto 35 sq. mm
1000
-
18
... More
Supply of following capacity aluminium armourd cable PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade in the existing RCC/ HUME/ METAL pipe as required.
a) 2 X 16 sq. mm
500
-
63
... More
b) 4 X 16 Sq. mm
500
-
80
... More
c) 4 X 25 Sq. mm
500
-
103
... More
Misc. spares such as relays, Ammeter, Voltmeter, indication lamps and also providing wiremesh protection and locking arrangement to the feeder pillars
1
-
10000
... More
Pump Set for underpasses, Subways
-
-
-
... More
Operation & Maintenance of DG set & Substation Operation & maintenance of 11 KV / 415 V,400 KVA substation comprising of transformer, HT/LT panel and 1 no 100 KVA DG set with auto start panel round the clock on all the days i/c Sundays & holidays and general maintenance of E.I & Fans in the following locations. The job also includes recording of all parameters like HT & LT voltages, current, power factor etc. & routing periodical checking & testing as per terms and conditions and as per inventory attached. (Annexure-D)
1. Wireman/Electrician – 3 Nos. (on all days i/c Sunday and Holidays) a) Shastri park
(For 1 no locations)
12
-
72492
... More
Operation of Dewatering Pumps at Underpasses
A) Running, Maintenance operation and Watch & ward of dewatering pumps installed at following locations round the clock on all the days i/c Sundays & Holidays & as per terms and conditions and as per inventory attached. (Annexure-E)
1. Pump Operator – 3 Nos. (on all days i/c Sunday and Holidays)
2. Khallasi – 1 No. (on all days i/c Sunday and Holidays)
a) Nathupura underpass
(For 1 no locations)
4
-
92385
... More
Operation & Maint. Of sewage/storm water pumps Harsh Vihar and Old Seemapuri
-
-
-
... More
Repairing of existing pumps i/c replacement of stuffing box, shaft sleeve, straighting of shaft, ball bearing, greasing and the all necessary replacement of spares in the existing pumps at harsh vihar and old seemapuri and reinstallation & Commissioning of those pumps in their places including making and correcting the level of foundation with the help of necessary tools and equipments with all safety precautions for executing the work etc as required. 150 HP
1
-
29708
... More
100 HP
3
-
29708
... More
75 HP
2
-
27597
... More
40 HP
4
-
26088
... More
Fabricating , providing and installation of waste handling motorized screen mesh made out of SS 410 stainless steel perforated sheet of size 25mm spacing and whose dimension as per site requirement (Screen area not less than 2 sqm and thickness not less than 8 mm) suitable for inlet channel of the pumping facility. This screen is to be supported with help of ISMC 200 along with electrical hoist facility with a capability not less than 1 metric ton which is used to raise and lower the screen. The screen is to be arranged in the inlet of suction line at such an inclination that the position of the screen should not be misaligned because of incoming flow complete as required at site.
2
-
153283
... More
Fabrication Supplying and providing waste handling bin of size 2mtr X 2Mtr. X 1 Mtr. Height made out of 5 mm thick or more M.S. Sheet dully painted with tarpaulin cover, to be fixed in ground with suitable size M.S. angle lugs /CC foundation the tank to be supported by suitable size M.S angle all around complete etc as required (the design of this bin is to be approved by engineer in charge before excavation)
4
-
25000
... More
SITC of self priming mono submersible pump of 1 hp or more suitable for automatic priming to all the existing pumps fitted with necessary accessories and complete piping connection as required.
2
-
25000
... More
Fabrication , supplying, installation, testing and commissioning of indoor type free standing weather and vermin proof flush compartmentalized modular, totally enclosed type electrical starter panel ( as per general arrangement size not less than 2.4m (W) x 2.175 m (H) x 0.7 m deep made out of 2.0mm thick sheet steel with front and back hinged openable double leaf doors with panel lock including supplying and fixing following accessories inside the panel, drilling, welding, providing detachable gland plate / knock outs plate, connections, inter -connections with suitable size aluminium strips / earthing etc, as required. The cubicle board shall be provided with base channel of (ISMV 100 designation) of size 50 x 50mm including painting the base channel with primer and finish paint, complete as per general arrangement drawing approved by Engineer-in-charge.
The LT panel shall generally confirm to CPWD General Specifications for Electrical works, Part-I, Internal 2005, Part-II External 1994 and Part -IV substation equipment -2007 as amended upto date.
The panel shall be installed on a suitable brick pedestal of suitable size in an approved manner.
-
-
-
... More
(A) 630A MCCB INCOMER
i) 630 Amp. TP MCCB 50KA with Microprocessor based (O/C, S/C & E/F Release) – 1
ii) Rotary Operating for 630 Amp. FP MCCB -1
iii) Spreader terminal for 630 Amp. TP MCCB -1
iv) 630 AMP. FP On LOAD CHANGEOVER SWITCH -1
(B) METERING & INDICATION
i) Phase indicating light R,Y (Red/Yellow), 22.5 Sq. MM Dia 230V AC – 2
ii) Phase indicating light B (Blue), 22.5 Sq. MM Dia, 230V AC -1
iii) Digital flush type class 1 accuracy multifunction meter, Showing V, A PF, Hz ,KW, kWH kVAR -1
iv) Metering CT-630/5A, CL-1.0, 15 VA Tape Wound – 3
v) 6A SP MCB, 10kA, TYPE ‘C’ CURVE - 3
-
-
-
... More
Centrifugal pump 150HP–S/D STARTER–1 No.
i) 400 Amp. TP MCCB 50KA MOTOR DUTY WITH S/C RELEASE – 1
ii) Rotary Operating For 400 Amp. TP MCCB – 1
iii) Spreader terminal For 400 amp. TP MCCB – 1
iv) 250A, AC-3 Duty power contactor, with 2 NO+2NC Coil Voltage 230 AC – 3
v) Over load relay 90-150 Amp. With Built-in Single Phasing protection – 1
vi) Auxiliary Contactor with 2 NO+2NC, Aux, Supply 230V AC – 1
vii) Metering CT- 400/5A, CL-1.0, 10A Tape Wound – 3
viii) Digital Amp. Meter, 1 Phase, 2 Wire, CTR-5A, CL-1.0, Aux. Supply 230 V AC, 96 Sq. Mm – 1
ix) Amp. Meter selector Switch – 1
x) Single Phase Preventer Relay, 230V AC – 1
xi) Indicating light R, G(Red), Green, 22.5 Sq. MM Dia, 230 V AC – 3
xii) Start/Stop Push button, Red, 22.5 Eq. Dia with Center Off, 6 Amp. – 2
xiii) Auto/Manual Selector Switch, 1P, 2 W With Center OFF 6 Amp. – 1
xiv) Star Delta Timer 0-60 Seconds, Aux. Supply 230V AC – 1
xv) 6A SP MCB, 10kA, TYPE ‘C’ CURVE - 3
-
-
-
... More
100 HP – S/D STARTER – 2 NOS.
i) 250 amp. TP MCCB 50KA MOTOR DUTY WITH S/C RELEASE – 2 ii) Rotary Operating For 250Amp. TP MCCB – 2
iii) Spreader terminal For 250 Amp. TP MCCB – 2
iv) 140A, AC-3 Duty power contactor, WITH 2 NO+ 2NC Coil Voltage 230V AC -6
v) Over load Relay 60-100 Amp. With Built-in- Single Phasing protection – 2
vi) Auxiliary Contactor with 2 NO + 2 NC, Aux. Supply 230V AC – 2
vii) Metering CT-250/5A, CL-1.0, 10A Tape Wound – 6
viii) Digital amp. Meter, 1 Phase, 2 Wire, CTR/5A, CL-1.0, Aux. Supply 230 V AC, 96 Sq. mm
ix) Amp. Meter Selector switch – 2
x) Single Phase Preventer relay, 230V AC – 2
xi) Indicating light R, G(Red, GREEN 22.5 Sq. MM Dia with 1 NO Element – 6
xii) Start/Stop Push button, Red, 22.5 sq. Dia With 1 No Element – 4
xiii) Auto/Manual Selector Switch, 1P, 2W With Center OFF, 6 Amp. – 2
xiv) Star delta Timer 0-60 Seconds, Aux. Supply 230V AC – 2
xv) 6 A SP MCB, 10kA, TYPE ‘C’ CURVE - 6
-
-
-
... More
75 HP- S/D STARTER – 2 NOS.
i) 250 Amp. TP MCCB 50KA MOTOR DUTY WITH S/C Release – 2
ii) Rotary operating For 250 Amp. TP MCCB – 2
iii) Spreading terminal For 250 Amp. TP MCCB–2
iv) 95 A, AC-3 Duty power Contactor, with 2 NO + 2 NC Coil Voltage 230V AC – 6
v) Over load relay 42-79 Amp. With Built-in Single Phasing Protection – 2
vi) Auxiliary Contactor With 2 NO+ 2NC, Aux. Supply 230V AC – 2
vii) Metering CT- 250/5A, CL-1.0, 10A Tape Wound – 6
viii) Digital amp. Meter, 1 Phase, 2 Wire, CTR/5A, CL-1.0, Aux. Supply 230 V AC, 96 Sq. Mm – 2
ix) Amp. Meter Selector Switch – 2
x) Single phase preventer Relay, 230V AC – 2
xi) Indicating light, R G (Red, GREEN 22.5 Sq. MM Dia, 230 V AC – 6
xii) Start/Stop Push button, Red, 22.5 Sq. Dia With 1 No. Element- 4
xiii) Auto/Manual Selector switch, 1 P, 2 W With Center OFF 6 Amp. – 2
xiv) Star Delta Timer 0-60 Secons, Aux. Supply 230 V AC – 2
xv) 6 A SP MCB, 10kA, TYPE ‘C’ CURVE - 6
-
-
-
... More
40 HP – S/D STARTER – 1 NO.
i) 250 Amp. TP MCCB 50KA MOTOR DUTY WITH S/C RELEASE – 1
ii) Rotary Operating For 250 Amp. TP MCCB – 1
iii) Spreader terminal For 250 Amp. TP MCCB – 1
iv) 95 A, AC-3 Duty power Contactor, with 2 No. +2 NC Coil Voltage 230V AC – 3
v) Over load relay 28-46.5 Amp. With Built-in Single Phasing Protection -1
vi) Auxiliary Contactor With 2 NO+ 2NC, Aux. Supply 230V AC – 1
vii) Metering CT- 250/5A, CL-1.0, 10A Tape Wound – 3
viii) Digital amp. Meter, 1 Phase, 2 Wire, CTR/5A, CL-1.0, Aux. Supply 230 V AC, 96 Sq. Mm – 1
ix) Amp. Meter Selector Switch – 1
x) Single phase preventer Relay, 230V AC – 1
xi) Indicating light, R G (Red, GREEN 22.5 Sq. MM Dia, 230 AC – 3
xii) Start/Stop Push button, Red, 22.5 Sq. Dia With 1 No. Element- 2
xiii) Auto/Manual Selector switch, 1 P, 2 W With Center OFF 6 Amp. – 1
xiv) Star Delta Timer 0-60 Seconds, Aux. Supply 230 V AC – 1
xv) 6 A SP MCB, 10kA, TYPE ‘C’ CURVE - 3
2
-
508600
... More
Supplying and fixing M.S. chequered plate of size 6mm thick including supporting with angle iron frame work on the existing masonry open duct etc, complete as required.
100
-
4572
... More
Supplying installation testing & commissioning of 630 Amps. off load change over switch- AC 21 (side handle) 4 pole 415 volts, 50 Hz of following ratings in sheet metal enclosure complete the existing panel etc as required.
2
-
39099
... More
Dismantling of existing damaged, corroded MS delivery pipe of following sizes i/c cutting the pipe, taking it out from the delivery header from a height of approx 2-3 mtrs dismantling from Sewage pump suctions with the help of special hoist and safety belts with highly skilled riggers with all safety precautions and storing it at PWD store/designated place Length of pipes shall be in sorted sizes ranging from 1-3 mtr.
150/200 mm dia
18
-
389
... More
250/300/400 mm dia
6
-
442
... More
Replacement of old damaged pipe line with new Supplying, fabrication and installation of following sizes of MS pipes i/c cutting, welding, fixing in position/c making fabrication of tees/miter bends and installing with heavy duty lifting hoists/hydra etc as required in the sump/overhead at approx 3 mtr height/ installing in sump suction with special hoist, highly skilled riggers with safety belts as required.
-
-
-
... More
150 mm dia medium (C class)
6
-
1783
... More
200 mm dia 6 mm thick
12
-
2645
... More
300 mm dia 6 mm thick
6
-
3427
... More
Replacement of old damaged flanges with new Supplying, fixing and welding of following sizes of MS heavy duty flanges complete with water proof gasket, nuts bolts etc as required.
-
-
-
... More
150mm dia 6mm thick
6
-
1145
... More
200 mm dia 6 mm thick
12
-
1334
... More
300 mm dia 6 mm thick
6
-
2222
... More
Replacement of damaged bends with new Supplying, Fixing , welding of heavy duty Bands of Following sizes i/c anticorrosive painting and dismantling the existing defective one etc as required
-
-
-
... More
150mm dia 6mm thick
4
-
2020
... More
200 mm dia 6 mm thick
6
-
2722
... More
300 mm dia 6 mm thick
6
-
3762
... More
Less on Account of dismantled material received from the work.
-
-
-
... More
Burnt out/ defective spares of various sizes pumps
1
-
25000
... More
Various sizes MS Pipe 150/200/250/300 mm dia
1
-
10000
... More
Various sizes MS Flanges/ Bends 150/200/250/ 300 mm dia etc.
1
-
5500
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements