Public Works Department Tender

... More
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Public Works Department - PWD Tender

Services
Eprocure
Opening Date14 Feb 2025
Closing Date21 Feb 2025
Tender Amount₹ 24,26,869 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
3 Module (100 mmX75 mm)

40

327

13080

... More
6 Module (200mmX75mm)

25

402

10050

... More
8 Module (125 mmX125 mm)

15

454

6810

... More
12 Module (200mmX150mm)

10

547

5470

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
3 X 1.5 mm

400

95

38000

... More
3 x 4 sq. mm

250

206

51500

... More
3 x 6 sq. mm

150

304

45600

... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm

100

256

25600

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 amps switch

50

103

5150

... More
15/16 A switch

25

156

3900

... More
3 pin 5/6 A socket outlet

20

122

2440

... More
6 pin 15/16 A socket outlet

10

197

1970

... More
Telephone socket outlet

10

148

1480

... More
Bell push

15

140

2100

... More
Supply, Installation, Testing and Commissioning of BEE rated, ceiling fan with squirrel cage induction Motor, class of insulation: B, 3 nos. metal( Aliminium alloy blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body, Power Factor not less than 0.9 , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit of suitable wattage for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as reqd. i) 1200mm, BEE 3 star rating, service value ≥5.0 to 5.5 CM/Min/Watt, air delivery 210 CM/Min ( Minimum).

50

2669

133450

... More
Supplying, Installation, Testing and Commissioning of 380 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd.

5

4694

23470

... More
Supplying, Installation, Testing and Commissioning of 250 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd.

5

1535

7675

... More
Supplying, installation, Testing & Commissioning of LED Recessed/surface Panel Down lighter (Round / square/ Rectangular, powder coated die cast aluminium/polycarbonate body with built in driver ( 750ma), Operating voltage AC 100-240 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, IP20, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard (As mentioned in Bottom Note)and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. "complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required" , (LM79 & LM80) certificate / Report from OEM shall be submitted, Minimum 5 year OEM warranty, . Shape size and CCT shall be as approved by Engineer in charge. System lumen efficacy ≥105 and 120 lm/Watt output All as per pre approved by Engineer-in-charge.

-

-

-

... More
8-10 watt

50

1346

67300

... More
Supplying, installation, Testing & Commissioning of LED surface mounted Batten light, powder coated die cast aluminium /polycarbonate body with built in driver ( 750ma),Operating voltage AC 100-240 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, IP20, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard (As mentioned in Bottom Note)and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. "complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required" , (LM79 & LM80) certificate / Report from OEM shall be submitted. Minimum 5 year OEM warranty, . Shape size and CCT shall be as approved by Engineer in charge. System lumen efficacy system lumen efficacy ≥105 and 120 lm/Watt output. All as per pre approved by Engineer-in-charge.

-

-

-

... More
18-20watt (1200 mm 4 Feet)

150

1418

212700

... More
Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in driver (700ma), Input voltage: Input voltage: 100-240 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency 85%,THD 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-65,IK-08, CRI 80 , under voltage and over voltage protection, EMI-EMC As per CISPER 15 A, lenses for beam angle 45* 120 deg., suitable tilt able fitting, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. "complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required" , (LM79 & LM80) certificate / Report from OEM shall be submitted. Minimum 5 year OEM warranty, . Shape size and CCT shall be as approved by Engineer-in-charge. System lumen efficacy ≥120 and 135 lm/Watt output All as per pre approved by Engineer-in-charge ( Thermal management: heat sink of aluminium housing. aluminium metal-core printed board of thermal conductivity more than 2.0W/mk and thermal pad with thermal conductivity more than 1.5W/mk) etc. as required.

-

-

-

... More
150 watt

5

9924

49620



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.