Northern Railway Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
AI Insights
Technical
Technical
Financial
Bid Capacity
... View More
The bid capacity required is the minimum average annual contractual turnover of V/N or 'V' whichever is less, where V = 207.08225 crores and N = 0.5 years. To calculate this, we need to determine V/N and compare it to 'V'. V/N = 207.08225 / 0.5 = 414.1645 Since 'V' (207.08225) is less than V/N (414.1645), the minimum average annual contractual turnover required is 207.08225 crores. Therefore, the bid capacity required in the given tender to bid is 207.08225 crores.
Technical Capacity
... View More
The required prior work experience for the bidder involves successfully completing similar works within a specified timeframe. For subletting work costing above Rs 50 lakh, the subcontractor must have completed at least one similar work in the last 5 years, with a value of not less than 35% of the work to be subletted. However, for work costing up to Rs 50 lakh, no prior experience is required. In another scenario, the tenderer must have completed one of the following: three similar works each costing at least 30% of the advertised tender value, two similar works each costing at least 40% of the advertised tender value, or one similar work costing at least 60% of the advertised tender value, all within the last 7 years. For composite works, similar requirements apply, with the percentages (30%, 40%, 60%) relative to the advertised value of each component of the tender. The bidder must submit supporting documents such as work orders, bills of quantities, and payment details to verify the work experience.
Costs
EMD
₹ 2,53,600Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Electrical Work In Connection With Repair Of Defective Solar Plant, Solar Water Heater (swh), Solar Pumps And Stand-alone Solar Street Light And Camc Of Above Plant Over Delhi Division.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
30-Elect-58-T-R1-24-25-E3-DELHI DIVISION-ELECTRICAL/NORTHERN RLYTender No
30-Elect-58-T-R1-24-25-E3Tender Authority
Northern Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply, Fixing, Testing & Commissioning of Dry cell battery Bank (make in India) to 4 store the power of 10kwp back up, 120volt, 350ah DC Service life of 8000c/s (guarentee of 5 yrs) including accessories i.e. copper interconnection wire, SS304 Hardware nut, bolt, washer etc (as per RDSO approved make C10/material confirming to latest CEE Specification) for NRWWO TKD KG School.
1
472000
472000
... More
Provision of Cloud based Remote Monitoring System, weather sensor, MODBUS RS 484, 5 communication port etc. for existing ON/OFF Grid solar plant over DLI Division. Location: Railway Board; 03 Nos., B. H.: 03 Nos., Panipat: 01 No., Diwana: 01 No., Sonipat; 01 No., NDLS: 03 Nos., MTC: 03 Nos., PHG NRCH & NRWO: 02 Nos., SBB (Old & New): 02 Nos., TKD School: 01 No., DKZ: 01 No., RPSF: 01 No., DEC: 01 No., EMU GZB: 01 No., GGN: 01 No., BGZ: 01 No.
26
25000
650000
... More
Laying, fixing and commissioning of 50/35 sq.mm 4 core AI Armoured XLPE cable under the ground and some open through cable tray from one building to other as per site requirement. Note: Cable will be supplied by Railway.
500
80
40000
... More
Supplying, Installation, Testing & Commissioning of 10kva OFF GRID SOLAR INVERTER, 7 Single phase in, Single phase out, Purely Sinusoidal AC Voltage output, 50Hz, DC I/P Voltages 200V DC - 1000V DC, Inbuilt MPPT charger along with WIFI Data Logger with compatibility to provide remote data through SCADA/Ethernet provision on Optical Fibre connectivity complete. For RNA Station Make: Havells, ABB, SUNGROW, Delta or equivalent
1
150000
150000
... More
Supplying, Installation, Testing & Commissioning of 10kva ONGRID SOLAR INVERTER, 8 input 415volt AC 3phase, output 3 phase 415 volt AC 50Hz, DC Voltages 280V DC to 1000V DC, 2MPPT Inbuilt Dual Circuit Programmable output voltage along with WIFI Data Logger with compatibility to provide remote data through SCADA/Ethernet provision on Optical Fibre connectivity complete. Location: DRM OFFICE, NDLS Make: Havells, ABB, SUNGROW, Delta or equivalent.
1
130000
130000
... More
Supplying, Installation, Testing & Commissioning of 25KVA ONGRID SOLAR INVERTER, input 415volt AC 3phase, output 3 phase 415-volt AC 50Hz, DC Voltages 280V DC to 1000V DC, 9 2MPPT Inbuilt Dual Circuit Programmable output voltage along with WIFI Data Logger with compatibility to provide remote data through SCADA/Ethernet provision on Optical Fibre connectivity complete. make: Havells, Sang row, ABB or equivalent and Provision/Modification of Solar Plant FROM OFF GRID TO ON GRID SOLAR PLANT and Provision of solar plant NET METERING System in cooperation with DISCOM for converting Bahadurgarh Railway station .
1
202448
202448
... More
Supplying, Installation, Testing & Commissioning of 25kVA ONGRID SOLAR INVERTER, 10 input 415volt AC 3phase, output 3 phase 415 volt AC 50Hz, DC Voltages 280V DC to 1000V DC, 2MPPT Inbuilt Dual Circuit Programmable output voltage along with WIFI Data Logger with compatibility to provide remote data through SCADA/Ethernet provision on Optical Fiber connectivity complete. For DEC & SBB Station. Make:Havells, ABB, SUNGROW, Delta or equivalent.
2
202448
404896
... More
Replacement/Repair of 1.75kwp capacity PCU with Battery 48volt DC of Solar wind stream technology (Hybrid System) of existing Baraut Station (BTU).
1
300000
300000
... More
Supplying, Installation, Testing & Commissioning of conventional Lightening arrestor for 11kv, max current 150-200KA ,4MTR Hight from Roof Top and connection to the existing earth pit complete.
7
12000
84000
... More
Supplying, Installation, Testing & Commissioning of Single Core TPR Copper tinted Red 13 & Black Colour wire BIS Approved 4 SQ MM, highly insulated, Flame Retardant(FR), UV Protected. Note: Old defective dc string to be removed and deposited to store. Make :Polycab, Havells, KEI or equivalent Location:- NDLS DRM office, NDLS PF 2&3, SBB, DEC, NRCH
5000
53
265000
... More
Supplying, Installation, Testing & Commissioning of 40 mm PVC Conduit pipe, Heavy type with Gland including accessories consumable as per site requirement. Make: Polycab, KALINGA or equivalent
2500
90
225000
... More
Supplying, Installation, Testing & Commissioning of MC4 Solar Connector with 15 accessories compatible for 04/6 sq mm DC wire, UV Protected, Rated voltage 1000V DC, Contact resistance less than 1mohm, Water and fire resistance as per site requirement. Make: Kenbrook, Evelta or equivalent.
500
45
22500
... More
Supplying, Installation, Testing & Commissioning of PV Module Junction box for existing PV Module whose junction box is damaged suitable for 230wp-280wp Capacity module. For NRCH, BGZ station
150
2000
300000
... More
Dismantling, Shifting and reinstallation of existing 32.5 KWp capacity solar plant of Delhi DEC Station to other station at Delhi Division .The palnt will be convert from off Grid to ON Grid solar plant.
1
267800
267800
... More
Reinstallation of Solar PV Module in existing Solar Plant at NDLS Railway Station (PF No-2/3) which was dismantled during roof replacement work. (250 Nos. module, 300 Wp Capacity each) including fixing of DC Wire and MC-4 connector
75
6000
450000
... More
2X2500 LPD ETC SWH (Make: Arsh Electronics Private Limited) 48 Tube Manifold (1500o58)-5 sets 5000L Overhead Tank Heating Element 3kWx3 Nos. DEFECTS: i) 10 tubes damage, ii) 20 Rubber Gasket damage, iii) Pipeline Leakage, iv) De-scaling required LOCATION: EMU CAR SHED GZB 1 LPD= 1 Per Unit
-
-
19
... More
Removing of existing solar battery and battery box from pole and deposit to store.
50
1000
50000
... More
Supply, Fixing, Testing & Commissioning of 26 watt. LED street light inbuilt lithium ion battery (12 Watt) with battery charger IP65
50
20000
1000000
... More
Repair/Replacement of solar pump PCU unit as per site condition. Capacity-5 KWp (21/250 Wp), PCU make dalta Defective: PCU Driver starter defective and Protection circuit faulty Station :- KEX, GZB, MOZ, MDNR
4
412000
1648000
... More
Repair/Replacement of solar pump PCU unit as per site condition. Capacity-13( 17/250) PCU make dalta Defective : PCU Driver starter 1 and protection circuit faulty Station :- BPM
1
1236000
1236000
... More
Repair/Replacement of solar pump PCU unit as per site condition. Capacity:- 5Kwp(21/250 Wp), PCU make dalta Defective:- PCU Driver starter and protection circuit faulty. Station :- KPKI
1
412000
412000
... More
Repair/Replacement of solar pump PCU unit as per site condition. Capacity:- 5Kwp(21/250 Wp), PCU make dalta Defective:- PCU Driver starter and protection circuit faulty. Station :- KQL
1
412000
412000
... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and 31 providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 Item No. 5.2
15
6855
102825
... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip 32 earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 Item No. 5.9
75
144
10800
... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in 33 convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. etc as required conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 4.6.2. 150 mm width X 50 mm depth X 1.6 mm thickness
300
716
214800
... More
Comprehensive Annual Maintenance Contract of Solar Power Plants over Delhi Division in all respect complete for three years. (Total Plant Capacity: 551kwp OVER DLI DIVISION)
551
5856
3226656
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%