Northern Railway Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 4,94,500Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Provision Of Rcc Overhead Tank And Pump House With Pipeline For Passengers At Kex, kql,thbn,& Nnx Under Aden/smql
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
NIT-18B-23-24-W-2-DELHI DIVISION-ENGG/NORTHERN RLYTender No
NIT-18B-23-24-W-2Tender Authority
Northern Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Item No.045010 (045011 to 045016) under chapter No.4 i.e. item of Steel Reinforced of NR/DLI 4 USSOR-2010 edition (Corrected upto date) complete for all L&M as per Indian Railways Unified standard Specifications (Works & Materials) Volume-I & II 2010 edition (Corrected upto date).of USSOR-2010 (Corrected up to date)
-
-
7694256.96
... More
All items under chapter No.3 i.e. the chapter of Plain Concrete (except item No. 033061 to 033064 5 i.e."Cement Items" and except items banned by HQ (Corrected upto date) for USSOR-2010) of NR/DLI USSOR- 2010 edition (Corrected upto date) complete for all L&M as per Indian Railways Unified standard Specifications (Works & Materials) Volume-I & II 2010 edition (Corrected upto date).
-
-
2541836.03
... More
All items under chapter No.5 i.e. the chapter of BRICK WORK except items banned by HQ 7 (Corrected upto date) for USSOR-2010) of NR/DLI USSOR-2010 edition (Corrected upto date) complete for all L&M as per Indian Railways Unified standard Specifications (Works & Materials) Volume-I & II 2010 edition (Corrected upto date).
-
-
1956667.85
... More
All items under chapter No.7 i.e. the chapter of WOOD WORK except items banned by HQ 8 (Corrected upto date) for USSOR-2010) of NR/DLI USSOR-2010 edition (Corrected upto date) complete for all L&M as per Indian Railways Unified standard Specifications (Works & Materials) Volume-I & II 2010 edition (Corrected upto date).
-
-
72546.55
... More
All items under chapter No.8 i.e. the chapter of STEEL WORK AND ALUMINIUM WORK except 9 items banned by HQ (Corrected upto date) for USSOR-2010) of NR/DLI USSOR-2010 edition (Corrected upto date) complete for all L&M as per Indian Railways Unified standard Specifications (Works & Materials) Volume-I & II 2010 edition (Corrected upto date).
-
-
2051656.17
... More
All items under chapter No.9 i.e. the chapter of FLOORING PAVING AND DADO except items 10 banned by HQ (Corrected upto date) for USSOR-2010) of NR/DLI USSOR-2010 edition (Corrected upto date) complete for all L&M as per Indian Railways Unified standard Specifications (Works & Materials) Volume-I & II 2010 edition (Corrected upto date).
-
-
1793233.94
... More
All items under chapter No.10 i.e. the chapter of ROOFS AND CEILING except items banned by 11 HQ (Corrected upto date) for USSOR-2010) of NR/DLI USSOR-2010 edition (Corrected upto date) complete for all L&M as per Indian Railways Unified standard Specifications (Works & Materials) Volume-I & II 2010 edition (Corrected upto date).
-
-
332501.46
... More
All items under chapter No.11 i.e. the chapter of FINISHING AND MASONARY except item 12 No.115010 to 115200 and Item No.117050 to 117090 and items banned by HQ (Corrected upto date) for USSOR-2010) of NR/DLI USSOR-2010 edition (Corrected upto date) complete for all L&M as per Indian Railways Unified standard Specifications (Works & Materials) Volume-I & II 2010 edition (Corrected upto date).
-
-
703348.61
... More
Item No.115010 to 115200 and Item No.117050 to 117090 under chapter No.11 i.e. the chapter of 13 FINISHING AND MASONARY except items banned by HQ (Corrected upto date) for USSOR-2010) of NR/DLI USSOR-2010 edition (Corrected upto date) complete for all L&M as per Indian Railways Unified standard Specifications (Works & Materials) Volume-I & II 2010 edition (Corrected upto date).
-
-
1950333.34
... More
All items under chapter No.12 i.e. the chapter of PAINTING, POLISHING & VARNISHING except 14 items banned by HQ (Corrected upto date) for USSOR-2010) of NR/DLI USSOR-2010 edition (Corrected upto date) complete for all L&M as per Indian Railways Unified standard Specifications (Works & Materials) Volume-I & II 2010 edition (Corrected upto date).
-
-
156686.06
... More
All items under chapter No.13, 14 & 15 i.e. the chapter of WATER SUPPLY, DRAINAGE AND 15 SEWERAGE & SANITARY INSTALLATION except items banned by HQ (Corrected upto date) for USSOR-2010) of NR/DLI USSOR-2010 edition (Corrected upto date) complete for all L&M as per Indian Railways Unified standard Specifications (Works & Materials) Volume-I & II 2010 edition (Corrected upto date).
-
-
19659731.78
... More
All items under chapter No.17 i.e. the chapter of MISCELLANEOUS BUILDING WORKS except 16 items banned by HQ (Corrected upto date) for USSOR-2010) of NR/DLI USSOR-2010 edition (Corrected upto date) complete for all L&M as per Indian Railways Unified standard Specifications (Works & Materials) Volume-I & II 2010 edition (Corrected upto date).
-
-
366336.57
... More
All items under chapter No.18 i.e. the chapter of DISMANTLING AND DEMOLISHING except items 17 banned by HQ (Corrected upto date) for USSOR-2010) of NR/DLI USSOR-2010 edition (Corrected upto date) complete for all L&M as per Indian Railways Unified standard Specifications (Works & Materials) Volume-I & II 2010 edition (Corrected upto date).
-
-
56216.06
... More
All items under chapter No.19, 20, 21 & 22 i.e. the chapter of BRIDGE WORKS except items banned by HQ (Corrected upto date) for USSOR-2010) of NR/DLI USSOR-2010 edition (Corrected upto date) complete for all L&M as per Indian Railways Unified standard Specifications (Works & Materials) Volume-I & II 2010 edition (Corrected upto date).
-
-
1010477.57
... More
All items under chapter No.23 i.e. the chapter of ROAD AND PLATFORM WORKS except items 19 banned by HQ (Corrected upto date) for USSOR-2010) of NR/DLI USSOR-2010 edition (Corrected upto date) complete for all L&M as per Indian Railways Unified standard Specifications (Works & Materials) Volume-I & II 2010 edition (Corrected upto date).
-
-
1147918.45
... More
Supplying and fixing water level indicator with 100 mm pipe metal, float M.S. gauge boards, wires etc. incl. Painting of board as per approved plan for all heights, all labour and material as a complete job.
10
6893
68933.7
... More
P&F lightening conductor with copper strip 20 mm x 3 mm fixed to be center of the top slab of the ventilator with aluminium down conductor in accordance with the I.S. specifications, incl. all heights and depths with all labour and materials etc. with earthing embedded in ground as a complete job. Per Metre
10
7069
70694.4
... More
Conducting Plate load test with contractor's T & P, labour etc. and submitting report to Divn. For approval of foundation detail
16
18864
301826.08
... More
Item rate for testing bearing capacity of soil from recognised lab etc. with all inclusive.
10
21488
214880.2
... More
"Item rate P & adding water proofing cement admixture of pidiproof LW or similar made @ 200 ML per bag ( 50 Kg.) as per direction of the engineer, water proofing compound to be got approved from the engineer. Rate shall be inclusive of all lead, lift, taxes L&M, T&P etc."
1185
100
119033.25
... More
Providing and laying in position M 25/30 Grade concrete for reinforced concrete cast in situ as per 8 approved plan in foundation, beam, pillars, dome etc. for all heights structural elements including cost of centring, shuttering mechanical mixing, vibrating and reinforcement alongwith cost of Admixtures in recommended proportion (as per IS: 9103) to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge ( cost of cement and steel extra)
900
11737
10563912
... More
C I Rate for drilling suitable size of bore for installation of tube well of 250/200 mm dia in soil rack,soilder stone ,mica etc by mechanical rig including all L&M,T&P,Fuel etc.Nothing extra will be paid whatsoever the case may be.
1000
1953
1953140
... More
C I Rate for supplying,lowering of MS pipe 200 mm dia blind pipe (medium pipe).4.85 mm thick,including handling ,rehauling,loading unloading,crossing of track nallah etc as a complete job.Nothing extra will be paid whatsoever the case may be.
1128
2963
3342692.64
... More
C I Rate for supplying,lowering of MS pipe 200 mm dia slotted pipe(medium pipe).4.85 mm thick,including handling ,rehauling,loading unloading,crossing of track nallah etc as a complete job.Nothing extra will be paid whatsoever the case may be.
100
3185
318564
... More
Gravel packing in Tube well construction in accordance with IS:4097, including providing gravel fine/medium/ coarse in required grading and sizes as per actual requirement, all complete as per direction of Engineer -In -Charge.
20
971
19425.8
... More
Development of tube well in accordance with IS:2800 (Part -I) and IS :11189 , to establish maximum rate of usable water yield without sand content ( beyond ppermissible limits), with required capacity air 13 compressor, running the compressor for required time till well is fully developed , measuring yield of well by 'V' Notch method or any other approved method , measuring static level and draw down etc by step draw down method , collecting water samples & getting tested in approved laboratory , i/c disinfection of tube well, all complete including hire and labour charges of air compressor, tools, & accessories etc , all as per requirement and direction of Engineer-In-Charge.
800
596
477336
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements