Military Engineer Services Tender
... More
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 85,554Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Special Repair Of Lt Distribution Panels At Ncs Chanakyapuri And Special Repair/ Replacement Of Lt Panel Near Swimming Pool Ss Complex
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_677501_2Bid Award Id
ViewTender No
NIT No GE/ND-70/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supplying, fabrication, installation, testing and commissioning of LT panel not less than 3mm thick made out of modular polycarbonate thermoplastic enclosures outdoor type with copper bus bar factory made CPRI approved,floor mounting type, environment friendly,recyclable,UV resistant,halogen and silicon free,anti-acid and anti corrosive,IP-65 Protection in accordance with IEC 60529.The gasket material shall be plyurethane while the gas/ket shall be internally embedded including suitable working space in bus bar chamber suitable for 3 phase 4 wire system 415V,50HZ,AC supply and fixed on raised PCC 1:2:4,type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring,CT of suitable Ratio,digital voltmeter and ammeter, air passing holes with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangement including excavation and earth work including dismantling the unserviceable panel complete all as specified and directed and comprising the followings.
Incoming:-
(a) MCCB 100 Amps Amps 4 Pole, 25 KA- 01 No
(b) Bus bar rating- 160 Amps
(c) CT 100/5 Amps- 03 Nos
(d)Control fuse terminal block-06 Nos
(e) RYB Indicating lamp
(f) Digital Voltmeter and ammeter of suitable rating
Outgoing:-
(a) MCCB 63 Amps 3 pole,20 KA- 03 Nos
(b) MCB TPN 63 Amps,10 KA - 03 Nos
(c) MCB TPN 40 Amps,10 KA - 04 Nos
1
-
-
... More
Supplying, fabrication, installation, testing and commissioning of LT panel not less than 3mm thick made out of modular polycarbonate thermoplastic enclosures outdoor type with copper bus bar factory made CPRI approved,floor mounting type, environment friendly,recyclable,UV resistant,halogen and silicon free,anti-acid and anti corrosive,IP-65 Protection in accordance with IEC 60529.The gasket material shall be plyurethane while the gas/ket shall be internally embedded including suitable working space in bus bar chamber suitable for 3 phase 4 wire system 415V,50HZ,AC supply and fixed on raised PCC base 1:2:4,type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring,CT of suitable Ratio,digital voltmeter and ammeter, air passing holes with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangement including excavation and earth work including dismantling the unserviceable panel complete all as specified and directed and comprising the followings:-
Incoming:-
(a) MCCB 250 Amps,adjustable type, 4 Pole, 36 KA- 01 No
(b) Busbar rating- 400 Amps
(c) CT 250/5 Amps- 03 Nos
(b) spreader Link- 01 set( 06 Pcs)
(d) RYB Indicating lamp
(e) Digital Voltmeter and ammeter of suitable rating
Outgoing:-
(a) MCCB 125 Amps,adjustable type, 3 pole, 25 KA- 02 Nos
(b) MCCB 100 Amps,adjustable type, 3 pole 25 KA- 03 Nos
(c) MCCB 63 Amps,adjustable type, 3 pole 25 KA- 08 Nos (d) MCB TPN 32 Amps- 03 Nos
1
-
-
... More
Supplying, fabrication, installation, testing and commissioning of LT panel not less than 3mm thick made out of modular polycarbonate thermoplastic enclosures outdoor type with copper bus bar factory made CPRI approved,floor mounting type, environment friendly, recyclable, UV resistant, halogen and silicon free, anti-acid and anti corrosive, IP-65 Protection in accordance with IEC 60529.The gasket material shall be plyurethane while the gas/ket shall be internally embedded including suitable working space in bus bar chamber suitable for 3 phase 4 wire system 415V,50HZ,AC supply and fixed on raised PCC 1:2:4,type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring,CT of suitable Ratio,digital voltmeter and ammeter, air passing holes with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangement including excavation and earth work including dismantling the unserviceable panel complete all as specified and directed and comprising the followings:-
Incoming:-
(a) MCCB 125 Amps,adjustable type, 4 Pole, 25 KA- 01 No
(b) Bus bar rating- 200 Amps
(c) CT 125/5 Amps- 03 Nos
(d) spreader Link- 01 set( 06 Pcs)
(e) RYB Indicating lamp
(f) Digital Voltmeter and ammeter of suitable rating
Outgoing:-
(a) MCCB 63 Amps,adjustable type, 3 pole,25 KA- 02 Nos
(b) MCB TPN 40 Amps- 01 No
(c) MCB TPN 32 Amps-02 No
1
-
-
... More
Supplying, fabrication, installation, testing and commissioning of LT panel not less than 3mm thick made out of modular polycarbonate thermoplastic enclosures outdoor type with copper bus bar factory made CPRI approved,floor mounting type, environment friendly,recyclable,UV resistant,halogen and silicon free,anti-acid and anti corrosive,IP-65 Protection in accordance with IEC 60529.The gasket material shall be plyurethane while the gas/ket shall be internally embedded including suitable working space in bus bar chamber suitable for 3 phase 4 wire system 415V,50HZ,AC supply and fixed on raised PCC 1:2:4,type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring,CT of suitable Ratio,digital voltmeter and ammeter, air passing holes with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangement including excavation and earth work including dismantling the unserviceable panel complete all as specified and directed and comprising the followings:-
Incoming:-
(a) MCCB 100 Amps,,adjustable type, 4 Pole,25 KA- 01 No
(b) Busbar rating- 160 Amps
(b) CT 100/05 Amps- 03 Nos
(C) spreader Link- 01 set( 06 Pcs)
(d) RYB Indicating lamp
(e) Digital Voltmeter and ammeter of suitable rating
Outgoing:-
(a) MCCB 63 Amps,adjustable type, 3 pole,25 KA- 01 No
(b) MCB TPN 40 Amps - 01 Nos
(c) MCB TPN 32 Amps - 02 Nos
1
-
-
... More
Supplying, fabrication, installation, testing and commissioning of LT panel not less than 3mm thick made out of modular polycarbonate thermoplastic enclosures outdoor type with copper bus bar factory made CPRI approved,floor mounting type, environment friendly,recyclable,UV resistant,halogen and silicon free,anti-acid and anti corrosive,IP-65 Protection in accordance with IEC 60529.The gasket material shall be plyurethane while the gas/ket shall be internally embedded including suitable working space in bus bar chamber suitable for 3 phase 4 wire system 415V,50HZ,AC supply and fixed on raised PCC 1:2:4,type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring,CT of suitable Ratio,digital voltmeter and ammeter, air passing holes with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangement including excavation and earth work including dismantling the unserviceable panel complete all as specified and directed and comprising the followings:-
Incoming:-
(a) MCCB 160 Amps,adjustable type, 4 Pole, 36 KA- 01 No
(b) Bus bar rating- 250 Amps
(c) CT 160/5 Amps- 03 Nos
(d) spreader Link- 01 set( 06 Pcs)
(e) RYB Indicating lamp
(f) Digital Voltmeter and ammeter of suitable rating
Outgoing:-
(a) MCCB 63 Amps,adjustable type, 3 pole, 25 KA- 05 Nos
1
-
-
... More
Note For item No 01 to 08: The manufacturer of board / panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60 439-1 and IEC 61 439-2 for power switchgear and control gear assembly. The party must be submitted routine test certificate from manufacturer/principal company in accordance with IEC 60 439-1. The type test report as per CPRI (in accordance with IEC 60 439-1) should consist with following:
i) Degree of protection of system
ii) Temperature Rise Limit
iii) Dielectric Properties
iv) Short Circuit Withstand Strength
v) Effectiveness of protective circuit
vi) Clearance and creepage distance
vii) Mechanical Operation
2. For better safety the Polycarbonate encl shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-1, DIN VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 deg. Cent.
3. The impact strength of polycarbonate enclosures / boards i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08.
4. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable.
Make:- Hensel/Rittal/Seimens.
-
-
-
... More
M&L for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering including taking down old unsv earthing complete all as specified and directed by Engr-in-Charge.
16
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements