Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Telecommunication Services
Eprocure
Opening Date2 Sep 2024
Closing Date30 Sep 2024
Tender Amount₹ 48,88,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, laying and connecting of Ethernet Cat 6 LAN cable 4 pair UTP outdoor including suitable connectors and flexible PVC pipe for laying along with mast tower/in duct complete all as specified and directed by the Engg-in-Charge.

400

-

-

... More
M&L for tracing out faulty optical fibre cable using Optical Time Domain Reflectometer (OTDR) instrument testing kit and Route Tracer machine kit to trace/locate the exact route/location of faulty/damaged underground optical fibre cable of any length and any size/core, cutting the damaged/faulty fibre cable for splicing and jointing work and testing the optical fibre cable after fixing the joint enclosure complete all as specified and directed by the Engg-in-Charge. Notes:- (a) OFC, joint enclosures, excavation and earth work shall be measured and paid separately under respective item of Schedule. (b) OFC link up through joint work shall be completed within 48 hours of intimation of fault to the contractor including fault/route tracing time. For delay beyond 48 hours, the penalty @ Rs 1000.00 per day per OFC route shall be imposed on the contractor and the same shall be recovered from next RAR due to the contractor.

42

-

-

... More
Supply, laying, jointing, testing and connecting in replacement of OFC cable, armoured 12 core complete all as specified and directed by the Engg-in-Charge. Note: Earthwork for laying of HDPE duct for OFC shall be measured and paid separately under respective item.

1200

-

-

... More
M&L in replacement HDPE duct 40 mm, PN 6, manufactured as per IS-4984 & ISO-4427 standards in PE-63 grade complete all as specified and directed by the Engg-in-Charge.

1000

-

-

... More
S&F OFC Joint enclosure HDE type suitable for 12 core armoured optical fibre cable including splicing, isopropyl alcohol for cleaning complete all as specified and directed by the Engg-in-Charge.

60

-

-

... More
Excavation in trenches not exc. 1.5 mtr wide and not exc 1.5 mtr deep in any type of soil (soft/loose/hard) for laying/taking up/taking down of cables and getting out and levelling of bottom surface to required level complete all as specified and directed by the Engg-in-Charge.

180

-

-

... More
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified and directed by the Engg-in-Charge.

162

-

-

... More
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by the Engg-in-Charge.

18

-

-

... More
Boring of hole horizontally under road/pavement/hard standing or any other situation by manual means for crossing of HDPE pipe/fibre cable complete up to 50 mm bore and making good both the ends complete all as specified and directed by the Engg-in-Charge.

120

-

-

... More
Boring of hole horizontally under road/pavement/hard standing or any other situation by ultrasonic Trenchless technology for crossing of HDPE pipe/fibre cable complete up to 50 mm bore all as complete all as specified and directed by the Engg-in-Charge.

100

-

-

... More
M&L for RCC joint chamber open lid type of internal dimension 300 mm dia (minimum) suitable for fibre optic cable (OFC) joint enclosures incl all necessary earthwork in any type of soil, PCC base etc complete all as specified and directed by the Engg-in-Charge.

30

-

-

... More
M&L for RCC route marker indicator for Optical Fibre Cable of min height 500 mm above ground level, duly painted with yellow colour and marked (MES OFC) with black colour incl all necessary earthwork complete all as specified and directed by the Engg-in-Charge.

20

-

-

... More
Supply, installation, configration and testing in replacement of LTE router/modem, IP-67 rated for transmitting data on IEC 60870-5-104 protocol and having Industrial Grade processor CPU min 500MHz, flash memory min 32MB, RAM (DDR2) min 128MB, Communication Protocols -IEC 60870-5-104, Modbus RTU to TCP support, Modbus master, Ethernet port RJ45 AND rs 232, Security-Zone Based firewall, VLAN, DMZ, HTTPS local and remote connection, SIM PIN, Routing-DHCPO, Static routing, port forwarding, traffic routing, static/dynamic, DNS, Operating Voltage Range 24V DC, + 15%, Operating Temperature range -40 deg C to 60 deg C, up to 95% RH, Din Rail mountable and dual SIM (one standby) via two mini-SIM held in trays complete all as specified and directed by the Engg-in-Charge.

6

-

-

... More
Supply, configuration, testing and commissioning of STM Multiplexer in replacement complete having following configuration as minimum complete all as specified and directed by the Engg-in-Charge. a) STM-1 (1+1) SDH Add-Drop Multiplexer b) 19-inch 1U High Rack Mount version c) 2 x STM-1 Ports (1+1) d) Management: EOW, SNMP, EMS, NMS e) 8 x E1 cards. f) 4 x Ethernet Port (100Mbps, Electrical RJ45 (F)) g) Power Supply 48V DC, +/- 20%. h) 155Mbps SFP Transceiver, SDH/STM-1, Fast Ethernet, Duplex LC, 15Km, SMF j) 8E1 75 Ohm Connectorized Cable.

1

-

-

... More
Supply, installation, testing and commissioning in replacement AC-DC power supply having AC supply input range 110–265V, 50Hz and stable output DC supply 24/48V DC (+/- 5%) of capacity 2.5 Amp complete all as specified and directed by the Engg-in-Charge.

2

-

-

... More
Supply, installation, testing and commissioning in replacement DC power supply converter module suitable with input power supply 48 / 110 VDC with +/- 15% and stable output 24V DC supply of 2.5 Amp rating complete all as specified and directed by the Engg-in-Charge.

2

-

-

... More
S&F in replacement Digital Multifunction Transducer (Accuracy class 0.5) with LCD/LED display for measurement of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication of data on Modbus protocol including associated wiring using 1.5 Sqmm FRLS copper wire complete all as specified and directed by the Engg-in-Charge.

25

-

-

... More
M&L for configuration of Static IP address provided by Engineer-in-charge in LTE router/modem /gateway and integration of analog and digital data points of substation/panel for transferring data to centralized control centre on IEC 60870-5-104 communication protocol through M2M gateway and connectivity testing between router/modem and gateway using ping check for link up of wireless connectivity between router/modem and control centre through M2M gateway complete incl shifting of modem/router as per requirement complete all as specified and directed by the Engg-in-Charge.

36

-

-

... More
Supply, installation, configuration and testing in replacement of Numerical Feeder Relay for HT 11 KV VCB Panel comprising of new and modern numerical scheme for detecting, indicating and tripping the breaker on various faults like directional over-current or earth-fault in any of the three phases, negative sequence currents, circuit-breaker-failure alarm, tripping-circuit-failures complete including associated DI/DO wiring and integration with existing HT VCB panel, taking out old unsv relay complete all as directed. The relay shall also have the following features as minimum; (i) Programmable rated current 1A & 5A, (ii) Last 10 fault record & 100 event record with time stamping, (iii) 6 DI & 4 DO, (iv) Communicable on IEC61850 protocol, (v), Disturbance recording, (vi) CT Supervision, (vii) Self supervision function etc. The relay shall be fully integrated with the feeder, internally capturing feeder statuses incl. Breaker On/Off/Spring Chrgd/Test/ Service/AC-Fail and display the same locally through suitably labelled status LEDs. Relay shall have facility to locally Trip/Close the breaker as a backup to TNC switch provided separately on the panel. Testing and commissioning of devices shall be carried out by OEM after installation of equipment and cost of the same is deemed to be included complete all as specified and directed by the Engg-in-Charge.

20

-

-

... More
M&L for weekly deep cleaning of under mentioned Control Centre Hardwares and Servers using vaccum cleaner to avoid damage to the servers complete all as specified and directed by the Engg-in-Charge. (i) Different type of Servers - 22 Nos (ii) UPS 20 KVA - 02 Nos (iii) Ethernet Switches / Routers - 10 Nos (iv) Workstations - 06 Sets (v) Server Rack Panel with IP based KVM Switch & LCD Console - 02 Sets Notes:- (a) The deep cleaning of servers and hardwares shall be to full satisfaction of Engr-in-charge. (b) The vaccum cleaner and labour shall be arranged by the contractor at his cost and no extra claim shall be entertained in this regard. (c) Timely Non cleaning of servers and hardwares shall attract a penalty of Rs 1000 per week to the contractor and the same shall be recovered from next due RAR.

36

-

-

... More
Arrangement of monthly recharge/bill payment of dual SIM cards per communication equipment 4G modem/router system including replacement of SIM, if required due to non availability of existing network complete all as specified and directed by the Engg-in-Charge.

630

-

-

... More
M&L for Splicing work of optical fibre cable of 6/12 core for connection at fibre optic distribution box complete all as specified and directed by the Engg-in-Charge.

12

-

-

... More
S&F patch cords having any type of connectors (SC/LC/ST/FC) at both ends as per site requirement complete all as specified and directed by the Engg-in-Charge.

10

-

-

... More
S&F in replacement OFC 12 LIU port complete all as specified and directed by the Engg-in-Charge.

2

-

-

... More
M&L for configuring, testing, programming to integrate of 33/11 KV 16MVA transformer panel at Kirby Place substation with SCADA system and Integration of communication protocols to enable seamless data exchange between the transformer panel and the SCADA system and real-time monitoring of critical parameters such as KW, KWh, voltage, current, power factor, and temperature etc. with protocols such as Modbus, DNP3, or IEC 61850 for seamless integration with the SCADA system and have scalability to accommodate future expansion and integration with additional electrical assets and have compatibility with existing 33 kV transformer panel hardware and SCADA communication interfaces. The execution of all SCADA software integration items of work shall be carried out under technical support and guidance of System integrator and liability for software and system strictly adhere to no compensation on this account will be admissible. Performance of any equipment/items pertaining to MES shall not be hampered or damaged.

1

-

-

... More
S&F 4x1.5 sqmm PVC insulated and PVC sheathed copper flexible cable as required at site incl making connections complete all as specified and directed by the Engg-in-Charge.

100

-

-

... More
S&F 4x2.5 sqmm PVC insulated and PVC sheathed copper flexible cable as reqd at site incl making necessary connections complete all as specified and directed by the Engg-in-Charge.

100

-

-

... More
M&L for maintenance of RF communication network including inspection, cleaning, and recalibration of RF equipment components, antennas, transmitters, receivers, amplifiers, filters and associated hardware and testing and revalidation of RF equipment performance parameters, including frequency response, signal strength, modulation accuracy, and noise levels and resolve. Labour charges for replacement of worn-out or damaged components like cables, connectors, and other accessories, are included. As necessary, if any issue arises in communication due to RF network, prompt response to equipment failures, malfunctions, or performance degradation issues is required. Troubleshooting and diagnosis of RF equipment faults in hardware and software. Spare parts shall be supplied seperately.

1

-

-

... More
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.