Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_692615_1Tender No
GE/DE-133/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
CLEANING/ DESLUDGING OF SEWAGE LINE, SEPTIC TANKS/ SOAKAGE WELLS AND REPAIRS/ MAINT OF FOOTPATH, PCC PAVING, COMPOUND WALL, FENCING, DRAIN, CULVERT IN BASE HOSPITAL UNDER GE (EAST) DELHI CANTT-10
BOQ Items
... More
Demolition of brick work built in cement mortar complete all as specified and directed
35
-
-
... More
M & L for brick work with sub-class B brick straight or curved on plan built in cement mortar 1 : 6 complete all as specified and directed
35
-
-
... More
Taking down cement plaster/Grit plaster of any description on brick or stone walls etc including raking out joints hacking for key scrubbing down with water etc
800
-
-
... More
M&L rendering 15mm thick in Cement Mortar 1:4 on fair faces of brick or concrete, internal surfaces of walls finished and even & fair without using extra cement complete all as specifed & as directed.
300
-
-
... More
M & L 15 mm thick rendering in cement mortar (1:4), on brick or concrete wall surface, mixed with water proofing compound @ 3% by weight of cement, finished fair & even without using extra cement complete all as specified and as directed. (Note: WPC shall be measured and paid separately as supply only under relevent item of this Schedule)
550
-
-
... More
Supply only integral water proofing compound complete all as specified and directed by Engr-in-charge.
153
-
-
... More
M&L preparation of new plastered wall surfaces and applying two coats of Oil Bound Distemper over and including a coat of alkali resistant primer, over and including 3 mm thick cement based wall care putty complete all as specified and as directed.
300
-
-
... More
M&L preparation of new plastered wall surfaces and applying two coats of weather proof Exterior emulsion paint of colour & shade as approved (Colour scheme shall be as approved by the GE & user) over and including a coat of priming paint, over and including 3 mm thick cement based wall care putty complete all as specified and as directed. Make - Asian Apex Ultima or equivalent of make specified in PS.
435
-
-
... More
M & L for washed stone grit plaster on exterior walls in two layers, under layers 12 mm thick cement plaster 1:4 (1 cement :4 coarse sand) following the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer with 15 mm thick cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand:2 coloured marble stone chipping 10mm nominal size) including using Colour pigment & marble powder as required in ground in panels with groove all around as per approved pattern including scrubbing and washing the top layer with wire brushes and water to expose the stone chippings includind forming groove of uniform size 15mm wide and 15mm deep as per approved pattern complete all as specified and as directed.
150
-
-
... More
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified.
42
-
-
... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge.
150
-
-
... More
Dismantling of Stone slabs and tiles of any description or thickness laid bedded and pointed in any mortar in floor, aprons etc and including disposal of all debris exc 1.5 KMtr not exc 5 Km.
56
-
-
... More
M&L for 50 mm PCC type C -2 (1:3:6) using 40 mm graded crushed stone aggregate as in Sub base/levelling course complete all as specified and directed.
400
-
-
... More
M&L for non-skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over & including 15mm thick cement screed bed or bedding layer in CM 1:6, etc. complete all as specified and directed by Engr-in-Charge.
150
-
-
... More
M&L for 20-25 mm thick machine cut kota stone slab flooring jointed and pointed with grey cement slurry mixed with pigment to match the shade of the slab laid over 20 mm thick screed bed of CM 1:4 including rubbing and polishing complete all as specified and directed by Engr -in Charge.
200
-
-
... More
M&L for 20-25 mm thick machine cut kota stone slab in riser, steps and skirting jointed and pointed with grey cement slurry mixed with pigment to match the shade of the slab laid over 20 mm thick screed bed of CM 1:4 including rubbing and polishing complete all as specified and directed by Engr -in Charge.
10
-
-
... More
M&L for 100mm PCC type D -2 (1:4:8) using 40 mm graded crushed stone aggregate as in Sub base complete all as specified and directed.
350
-
-
... More
M&L for 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
200
-
-
... More
M&L for heavy duty coloured (approved colour) fully vitrified paving tiles of size 400mmx400mmx11 to 12mm thick, set and jointed in neat cement slurry and pointed in coloured or white cement to match the shade of tiles over and including 15 mm thick screed in cement mortar 1:6 complete all as specified and directed.
150
-
-
... More
Dismantling fencing wiremesh any type from TMT Bar/Fencing post complete all as spd & directed.
120
-
-
... More
Excavation in post hole (similar hole) each N Exc 0.5 Cum getting out, returning filling and ramming earth or brocken rubble mixed with earth around in layer not exc 25 CM watering and removing surplus soil to a distance N Exc 50 M and making good surface complete all as specifide and directed.
17
-
-
... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
2
-
-
... More
S&F mild steel joist channel angle for posts and struts in fencing, gate including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0
450
-
-
... More
Plain Cement Concrete Type C1 (1:3:6) (using 40 mm graded stone aggregate)in foundation filling and mass concrete complete all as specified and directed.
1
-
-
... More
Supply only Chain link MS galvanised fencing Weight Not exc 4.00 Kg/Sqm, of any type.
266
-
-
... More
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete
120
-
-
... More
M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new Steel Surfaces width or girth exc 10cm including preperation of surfaces complete all as specified and directed.
120
-
-
... More
M&L for One coats of synthetic enamel paint on old Steel Surfaces width or girth exc 10cm including preperation of surfaces complete all as specified and directed.
150
-
-
... More
Excavation of soil / mud from the rain water harvesting pits / drain and getting out from any depth of any type of soil and removal and spreading of excavated material from the site within the MOD land to a distance not exceeding 1000 metres complete all as specified and directed by Engr-in-charge.
4
-
-
... More
Cleaning of open/covered drain and hume pipes culverts etc and the like of any type, size of any description for silt/earth accumulated due to storm water and spreading the cleaned earth where directed complete all as specified and directed by Engr-in-charge.
Note: Cover slabs to be removed and refixed after cleaning with cement mortar (1:4) where covered drain exist.
50
-
-
... More
Cutting of bushes, weeds, vegetation etc removing all the waste to a distance exceeding 250mtr from drain complete all as specified and directed by Engr-in-charge.
200
-
-
... More
M&L for 75 mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base including use and waste of form work complete all as specified and directed by Engr-in-charge.
300
-
-
... More
M&L for PCC (1:2:4) type B0 using 12.5 mm graded stone aggregate as in coping, bed block for holdfast etc. including necessary form work complete all as specified and directed by Engr-in-charge.
1
-
-
... More
Extra for forming fair finished drain or channel up to 45 cm of girth in cement concrete using extra cement including forms moulds etc.
50
-
-
... More
S& F in repair 75mm thick factory made SFRC manhole/ drain covers of approved shape & size complete all as specified and as directed. Make : Polycrete or equivalent.
40
-
-
... More
Demolition of RCC of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr-in-charge.
2
-
-
... More
Use and waste form work to sides and soffits of floor, roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, over hangers etc also splays between floor and beam etc for rough finished surfaces of concrete flat complete all as specified and directed by Engr-in-charge.
20
-
-
... More
M&L for Reinforced cement concrete (1:2:4) (Nominal Mix) Type B1 using 20mm graded stone aggregate slabs supported on walls, beams, and columns, in floors, roof, landings, balconies, canopies, deck slab and in shelves and the like complete all as specified and directed by Engr-in-charge.
2
-
-
... More
M&L for MS TMT bar 10 mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire annealed not less than 0.9 mm dia and conforming to Fe 500 or Fe 550D complete all as specified and directed by Engr-in-charge.
200
-
-
... More
M&L for MS TMT bar 8 mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire annealed not less than 0.9 mm dia and conforming to Fe 500 or Fe 550D complete all as specified and directed by Engr-in-charge.
100
-
-
... More
Demolition & breaking up of 150 mm bore drain pipes (salt glazed ware, AC or reinforced pipes) including PCC bed and haunching set in cement mortar complete all as specified and directed by Engr-in-charge.
115
-
-
... More
Demolition & breaking up of 200 mm bore drain pipes (salt glazed ware, AC or reinforced pipes) including PCC bed and haunching set in cement mortar complete all as specified and directed by Engr-in-charge.
105
-
-
... More
M&L for 150 mm nominal size (DWCPE) Double wall corrugaged poly ethylene pipe ((SNB) including all fixing accessories of fittings like socket/spigot joint with elastomeric sealing ring, rubberring, SILAID rubber lubricants required for laying of pipes, laid in trenches, complete all as specified and as directed.
115
-
-
... More
M&L for 200 mm nominal size (DWCPE) Double wall corrugaged poly ethylene pipe ((SNB) including all fixing accessories of fittings like socket/spigot joint with elastomeric sealing ring, rubberring, SILAID rubber lubricants required for laying of pipes, laid in trenches, complete all as specified and as directed.
105
-
-
... More
M&L cement mortar concrete bed to drain pipes in PCC 1:3:6 type C-2 (using 40 mm graded crushed stone agg) incl packing under and against the sides of pipes after they are laid and tested in bores of pipe150mm dia complete all as specified and directed.
115
-
-
... More
M&L cement mortar concrete bed to drain pipes in PCC 1:3:6 type C-2 (using 40 mm graded crushed stone agg) incl packing under and against the sides of pipes after they are laid and tested in bores of pipe 200mm dia complete all as specified and directed.
105
-
-
... More
Dismantling of PVC pipes & fittings of any description & position up to 100 mm dia complete all as specified & directed.
250
-
-
... More
PVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
50
-
-
... More
S&F PVC (SWR) 75 mm bore pipe single socketed, in any length with rubber ring jointes , laid in trenches or in floor complete all as specified and directed.
60
-
-
... More
S&F PVC (SWR) 110 bore pipe single socketed, in any length with rubber ring jointes , laid in trenches or in floor complete all as specified and directed.
50
-
-
... More
S&F PVC (SWR) 110 bore pipe single socketed, in any length with rubber ring jointes ,fixed to wall complete all as specified and directed.
90
-
-
... More
S&F PVC (SWR) floor trap 75 mm dia, plain with grating including jointing with solvent cement complete all as specified and directed.
15
-
-
... More
S & F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
10
-
-
... More
S&F 75mm bore PVC (SWR) vent cowl complete all as specified and directed.
20
-
-
... More
S&F 110 x 75 mm PVC (SWR) reducers complete all as specified and directed.
10
-
-
... More
S & F in repair SS clamps heavy duty of 20 mmx 2 mm thick fixed by 8mm fastener for fixing PVC Pipe of 75 mm bore to wall or roof copletet all as specified and directed.
20
-
-
... More
S & F in repair SS clamps heavy duty of 20 mmx 2 mm thick fixed by 8mm fastener for fixing PVC Pipe of 100 mm bore to wall or roof copletet all as specified and directed.
20
-
-
... More
S&F 110 mm PVC (SWR) junction single, (Single T) equal or unequal with access door.
15
-
-
... More
S&F 75mm PVC (SWR) junction single, (Single T) equal or unequal with acces door.
15
-
-
... More
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
20
-
-
... More
S&F 75 mm bore PVC (SWR) bends any radius complete all as specified and directed.
20
-
-
... More
S & F in repairs Vitreous china floor mounted WC (Cascade) one piece type (off white) including connecetion in drain etc incl water closet seat cover , flushing cistern, with P or S trap with all fitting and fixture complete all as specified and as directed. (Make : Jaquar/ Marc/ Kohler).
9
-
-
... More
S & F in repair Vitreous China wash down water closet pan (pedestal pattern) of size 580 mm white with ‘P’ or ‘S” trap, any pattern including Seat Cover (excluding flushing cistern and flush pipe) complete all as specified and as directed.
5
-
-
... More
S & F in repair Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white premier quality, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, etc complete all as specified and as directed.
5
-
-
... More
S & F in repair 10 Ltr PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed.
5
-
-
... More
S&F in repair Vitreous China Urinal,Half stall type, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plug with CP Spinkle and including 60mm long brass screws, complete all as specified and as directed.
9
-
-
... More
S&F in repair Vitreous china urinal partition white of size 310 x 700mm complete all as specified and as directed.
7
-
-
... More
S&F in repair 15 mm bore angle stop valves cast copper alloy chromium plated screwed down high pressure with crutch or butterfly handle screwed withr iron pipe of union. (Make : Jaquar/ Marc/ Kohler).
31
-
-
... More
S&F in repair PVC connection 15mm bore with PTMT nuts of length 600mm.
31
-
-
... More
S&F in repair white Wash Basin with full Pedestal fo size 560 x 415 x 820 mm complete all as specified and directed. Make : Prayag/ Hindware/ Cera.
6
-
-
... More
S&F in repair 15 mm CP Brass Urinal spreader with Hex heavy quality for urinal complete all as specified and directed.
9
-
-
... More
S&F in repair PVC Urnial Waste Pipe 32 mm dia for urinal complete all as specified and as directed. Make : Prayag/ Hindware/ Cera.
9
-
-
... More
S&F in repair PVC Solid Waste Pipe 32 mm dia for WHB complete all as specified and as directed. Make : Prayag / Hindware/ Cera.
6
-
-
... More
S & F in repair 15mm bore WHB Mixture with swan neck complete all as specified & as directed. (Make : Jaquar/ Marc/ Kohler).
16
-
-
... More
M&L for repairing of spalled concrete form RCC surfaces (Such as ceiling, beams, columnms, parapets, chajjas etc) in the following stage :- (a) Preparation of existing surface like chipping of unsound weak/ loose concrete with electric hammer or manually including tapping all edges, making squre shoulder of cavities etc not exc 50 mm thickness, removal of debrises complete all sqfd. (b) Applying rust remover cum passivators sikka rust off 100 @ 0.20 Kg/ Sqm/each coat as per manufacture instructions to remove rust from existing reinforcement (make : - Sika or equivalent)
(c) Mixing and applying two components epoxy resin concrete bonding coat of sikadur (R&B 42)- @0.40 Kg/ Sqm (Mixing proportion as per manufactures instructions) including preparation of surfaces by chipping and thoroughly cleaning of surfaces complete wherever required over New reinforcement (if required) and as directed by EIC (make: sika or equivalent) Reinforcement shall be measured and paid saprately.
(d) Applying a prebached one component polymer modified cementious patch repair mortar N, exc 50 mm in layers of 15 mm thick each of product silka mono Top 122 F as per manufacturer instructions to match the existing surface as in sides and soffits etc of slabs, chajjas, fins, facias, parapets, lintels, columns and beams etc complete including necessary scaffolding, shuttering, necessary chases to brick work or RCC members at any height upto 6 storey building including removing of small trees shrubs etc all as specified and as directed.
40
-
-
... More
M&L for preparation of old decorated, wall, chequered floor, roof (corrugal) surface, by brooming and removing all loose layers of old treatment, efflorescence soot and moss by wire brush and filling all nail holes and patches with cement based wall care putty and applying one coat of weather proof Exterior emulsion paint of colour & shade as approved (to match with the Existing surface) complete all as specified and as directed.
Make- Asian Apex Ultima or equivalent of make specified in PS. Note: Quoted rates shall deemed to be includs painting at any height including scaffolding work, as required.
3850
-
-
... More
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundations etc. or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.50 Metre in depth and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge.
126
-
-
... More
All as per srl item No 80 but exceeding 1.5m and not exceeding 3m deep complete all as specified and directed by Engr-in-charge.
26
-
-
... More
Returning,filling in (soils),including spreading,levelling,watering and well ramming in layers not exc. 25cm thick all as specified.
137
-
-
... More
Removal of excavated soil from site to a distance not exceeding 50m away and depositing where directed at the level n.exc. 1.5m above the starting point all as specified.
15
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%