Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date22 Jul 2024
Closing Date13 Sep 2024
Tender Amount₹ 49,00,000
Costs
EMD
₹ 98,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_667324_1Bid Award Id
ViewTender No
GE (FBD)/AF-41/2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls, Ceiing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
250
-
-
M&L for rendering 15 mm thick cement plaster in CM 1:6 on brick Work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
122
-
-
M&L, Rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish even and smooth (w/o using extra cement) incl WPC as per manufacturer manual complete all as specified and directed by Engineer-in-Charge.
194
-
-
M&L for rendering 10mm thick in CM 1:3 over concrete surface as on ceiling, chajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed by Engineer-in-Charge.
38
-
-
M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall over one coat of primer incl one layer of 3mm thick wall care putty on new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
122
-
-
M&L for preparation of new plaster surface & apply two coats of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall care putty on new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
94
-
-
M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on ceiling over one coat of primer incl one layer of 3mm thick wall care putty on new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
38
-
-
M&L for two coat of Acrylic smooth exterior emulsion paint over one coat of acrlic primer incl one layer of 3mm thick wall care putty for exterior/interior on old scraped wall/ceiling surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
Note : Colour and make as approved by GE.
100
-
-
M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
10
-
-
M & L for one coat of synthetic enamel paint on steel surface including preparation of old steel surface width or girth exc 10cm complete all as specified and directed by Engineer-in-Charge.
100
-
-
Repair only to rolling shutter including necessary greasing, welding, locking arrangement including serviceing to gear box etc complete as to bring in service condtions etc complete all as specified and directed by Engineer-in-Charge.
5
-
-
Repair only to collapsible steel gate including necessary greasing, welding, locking arrangement including serviceing etc complete as to bring in service condtions complete all as specified and directed by Engineer-in-Charge.
1
-
-
S&F in repair 1.25mm thick Steel rolling shutters, gear operated type with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type incl taking down rolling shutters complete all as specified and directed by Engineer-in-Charge.
30
-
-
S&F Safety lever locks mild steel with 4 levers incl ball bearing for rolling shutters complete all as specified and directed by Engineer-in-Charge.
10
-
-
M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in laying of floor finishes and finishing smooth and even without using extra cement complete all as specified and directed by Engineer-in-Charge.
50
-
-
M & L for precast cement concrete louvers and jallies, 25mm thick, type B0 1:2:4 (12.5 mm graded stone aggregate), set in CM 1:4, including all mouldings complete all as specified and directed by Engineer-in-Charge.
25
-
-
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping/benching and all other similar works including necessary formwork complete all as specified and directed by Engineer-in-Charge.
2
-
-
S & F for mild steel framed work as in grill, guard bars etc with ends of bars/FI shoulders and or riveted or forged in to spikes, framed guard bars, barred iron doors, ladders, frame work of watertanks and and similar works confirming to Fe 410-0 or Fe 310-0 including dismantling old u/s complete all as specified and directed by Engineer-in-Charge.
450
-
-
S & F for Expanded metal, exc 4 kg weight per square meter, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel stables supplid and fixed complete to wood or steel members including dismantling old u/s complete all as specified and directed by Engineer-in-Charge.
350
-
-
S&F for plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attchment confirming to Fe 410-0 or Fe 310-0 including dismantling old u/s complete all as specified and directed by Engineer-in-Charge.
300
-
-
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris complete all as specified and directed by Engineer-in-Charge.
17
-
-
M&L 75mm thick PCC type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge.
197
-
-
Labour only for 80 mm thick machine cut precast concrete inter locking paver block except tile ,(M-40) grade any clours as approved by EIC /GE including dismantling old u/s complete all as specified and directed by Engineer-in-Charge.
57
-
-
M & L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
2
-
-
M & L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directed by Engineer-in-Charge.
140
-
-
Taking down carefully aluminum/copper point wiring of sizes 1.5 Sqmm cable any type (light, fan, switch, socket, power point, holder) complete includind fittings and fixtures and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified keeping aside serviceable items for reuse with in the same bldg and removing U/S items from site.complete all as specified and directed by Engineer-in-Charge. (Refixing of serviceable fitting shall be measured and paid seperately).
104
-
-
Taking down carefully copper / aluminum two core sub main wiring of sizes 4/6 Sqmm cable any type and removing old material from site and making good disurbed surface complete all as specified and directed by Engineer-in-Charge.
200
-
-
M&L for two single core PVC insulated cable with copper conductor multi stranded 4 Sqmm duly drawn through and including concealed PVC conduit medium grade suitable size as sub main with continuous earth wire 4 Sqmm size and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge. (Flexible Copper Wire Used In FRLS) Note : Two run of main wire one run of earth wire & one run of PVC conduit shall be measured one run.
200
-
-
M&L submain wiring with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 6 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by Engineer-in-Charge.
Note :Two runs of 6 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
100
-
-
M&L for point wiring complete with 1.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade FRLS cable IS-694 marked drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, fixed in wall, on roof with GI saddles GI screws, rawal plugs (concealed conduit in wall wiring) with all fittings including Tee, junction boxes and provision of 2 mm thick pressed steel terminal box of suitable size with 3 mm thick hylam laminated white sheet cover for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multistranded coper conductor of size 1.5 Sq mm (Nominal area) for following (Color coding to be followed) complete all as specified and directed by Engineer-in-Charge.
72
-
-
All as per item No 33 above but one three pin 5 Amps socket out let on the same board
12
-
-
All as per item No 33 above but one three pin 5 Amps socket out let on independant board
10
-
-
All as per item No 33 above but 15 Amps 3 pin socket outlet on independent board with 2.5 sq mm PVC insulated and sheathed copper conductor with 2.5 sq mm PVC insulated copper conductor single core for continuous earthing.
10
-
-
S&F Piano switch , flush button,single pole,one way 5/6 Amp complete all as specified and directed by Engineer-in-Charge.
94
-
-
S&F piano switch, flush button single pole one way 15/16 Amp complete all as specified and directed by Engineer-in-Charge.
10
-
-
S&F socket outlet,flush type 2 in 1, 2 pin and 3 pin 5 Amp complete all as specified and directed by Engineer-in-Charge.
22
-
-
S&F socket outlet, flush type 2 in 1, 3 pin and 6/16 Amp complete all as specified and directed by Engineer-in-Charge.
10
-
-
S&F stepped type electronic fan regulator, flush type on the existing phenolic laminated sheet etc complete all as specified and directed by Engineer-in-Charge.
2
-
-
S&F in repairs,ceiling rose surface backlight, 65 x 50 mm two to to three terminals complete all as specified and directed by Engineer-in-Charge.
104
-
-
S&F in replacement MCB SP 5 to 32 Amps, 240 volts curve 'C',breaking capacity 10KA complete all as specified and directed by Engineer-in-Charge.
10
-
-
S&F in replacement MCB SPN 32 to 63 Amps, 240 volts, curve 'C', breaking capacity 10 KA complete all as specified and directed by Engineer-in-Charge.
20
-
-
S&F in replacement MCCB, Four pole, 415 volts, 125 Amps , curve 'C', breaking capacity 10 KA complete all as specified and directed by Engineer-in-Charge.
10
-
-
S&F in replacement MCB TP 40 to 63 Amps, 415 volts curve 'C',breaking capacity 10KA complete all as specified and directed by Engineer-in-Charge.
4
-
-
M&L for Design, development, supply commissioning and testing EHCC certified ground tubular effective chemical earthing system (CPRI tested for 15 KA current capacity for LT Iine) highly anticorrosive long life electrode with and including adequate protective coating to withstand servere weather conditions in the earth pit of the standard size comprising of 40mm x 3m Long Copper rod as primary conductor and hollow copper tube of 80mm x 3m long as secondary conductor to install with suitable connecting terminal confirming of IS 3043 : 1987 specification, highly conductive packing material to be filled in earth pits for providing uniform, low resistivity anticorrosive, hygroscopic medium around the earth system for improving the efficiency of current dissipation with crystalline conductive mixture (CCM) 20 Kg per bag (3 bag per kit) minimum or sufficient quanitities required as per site complete including RCC earthing pit cover , material and labour including taking down old u/s complete all as specified and directed by Engineer-in-Charge.
7
-
-
M&L earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc including taking down old u/s complete all as specified and directed by Engineer-in-Charge.
9
-
-
M & L in replacement earthing with steel earth plate electrode of size 60 x 60 cm x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less tha 1.5 mtr deep below normal grund level connected to galvanized iron strip size 32 x 6 mm as earthing lead by means of nuts, bolts and washers of steel after wlding of GIstrip to earth electrode to the full length of earht plate, 40mm dia GI tubing lightgrade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover ofsize 30x30 cm made of RCC 1:3: with suitable handle, angle iron frame made of angle iron of size 40x40x4m, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetables soil to the remaining 10% removal of surplus soil and retruning filling in all as required at site including test point made outof steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I complete all as specified and directed by Engineer-in-Charge.
4
-
-
Supply and fixing time switch astro type/Nature switch fitted inside box complete with suitable contactor with all electrical connection after dismantling old one complete all as specified and directed by Engineer-in-Charge.
2
-
-
Supply and fix in replacement power Contactor three pole 40 Amps AC-1 rating, AC -3 rating 32 A with operating coil voltage 230V complete 2 NC and 2 NO fixed in exiting LT Paneel/ feedder pillar box including taking out unserviceable contractor etc complete all as specified and directed by Engineer-in-Charge.
2
-
-
Suply and fix in replacement of Sheet metal enclosure for MCCB 3P, one No complete all as specified and directed by Engineer-in-Charge.
2
-
-
S&F sheet metal enclosures DB Double door distribution type, 04 way, TPN DB , IP43, 415V & suitable for MCB TP as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and directed by Engineer-in-Charge.
2
-
-
S&F in replacement sheet metal enclosures DB Double door type 8 way SPN 240 volt including 200 Amps rated bus bar with neutral link complete all as specified and directed by Engineer-in-Charge.
2
-
-
S&F in replacement sheet metal enclosures DB Double door type 4 way SPN 240 volt including 200 Amps rated bus bar with neutral link complete all as specified and directed by Engineer-in-Charge.
4
-
-
S&F in repair floor mounted TPN busbar chamber outdoor type 3.15 CRCA Sheet factory made with busbar of current rating 400 Amp, 415, 4 way complete all as specified and directed by Engineer-in-Charge.
2
-
-
M&L forScraping of old paint from the steel tubular pole 9 mtr height with out removing accessories and preparation of surfaces repainting the pole with one coat of 30 cm alternative green and white strips of each upto 1.5 mtr height using synthetic enamel paint. Repainting the remaining pole and iron parts i.e. U clamps, channels etc above 1.5 mtr height by applying one coat of aluminium paint complete all as specified and directed by Engineer-in-Charge.
100
-
-
M& L for preparation of trench for cable laying of size 300mm x 450 x 10 m long including excavation & earth work in any type of soil brick work in CM 1:4, PCC work in 1:2:4 type B-1 using 20mm graded stone aggregate, plaster in CM 1:4 finished even & fair complete all as specified and directed by Engineer-in-Charge.
3
-
-
M& L for precast earthing RCC pit with cover of standard size duly painted in Red or Green complete all as specified and directed by Engineer-in-Charge.
20
-
-
M&L for earth pit cover bucket type Red or Green complete all as specified and directed by Engineer-in-Charge.
15
-
-
M&L for CI plate triangular with 500 mm long spike for writing earthing name and value complete all as specified and directed by Engineer-in-Charge.
20
-
-
Supply and fix steel pole tubular swaged 9 metres long complete with cast iron base plate , finialtaper plug , bolts , nuts and screws as specified type 410 SP-22 complete all as specified and directed by Engineer-in-Charge.
Note: PCC, earth work shall be measured and paid seprately.
10
-
-
Supply and fix cable duct cover made of MS of size 320mm x 800 mm of thickness 3.0 mm complete all as specified and directed by Engineer-in-Charge.
4
-
-
S & F rubber insulation mat of size 1.8 mtr x0.9mtr wide 2 mm thick red/blue colour ISI marked embossed for up to 33 KV as per latest IS complete all as specified and as directed by Engineer-in-Charge.
10
-
-
M&L for providing Display board of size 1m x 1m x1 cm madeup with acrylic sheet material consisting of "First Aid discription with pictures " in Capital Letter at the Top complete with fixing arrangements to the wall complete all as specified and directed by Engineer-in-Charge.
2
-
-
M&L for providing Display board of size 1m x 1m x1 cm madeup with acrylic sheet material consisting of "First safety instruction with fire extenguishing methods with pictures " in Capital Letter at the Top complete with fixing arrangements to the wall complete all as specified and directed by Engineer-in-Charge.
2
-
-
M&L for providing Display board of size 1m x 1m x1 cm madeup with acrylic sheet material consisting of "Safety instruction in case of electric shock with fire extenguishing methods with pictures " in Capital Letter at the Top complete with fixing arrangements to the wall complete all as specified and directed by Engineer-in-Charge.
3
-
-
M & L cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate for pole pedestal (PCC) including necessary form work etc complete all as specified and directed by Engineer-in-Charge.
7
-
-
M & L cement concrete in foundation filling and mass concrete type B2 1;2;4 (40mm graded stone aggregate) complete all as specified and directed by Engineer-in-Charge.
3
-
-
M & L cement concrete in foundation filling and mass concrete type D2 1:4:8 (40mm graded stone aggregate) complete all as specified and directed by Engineer-in-Charge.
3
-
-
M&L in repair Pre-cast cement concrete block masonry with solid blocks PCC Type B1 1:2:4 ( 20 mm graded stone aggregate ) , exc. 10 cm in width and setting in cement mortar 1:4, complete all as specified and directed by Engineer-in-Charge.
1
-
-
M&l in replacement tubing light grade galvanized iron to be embeded in PCC block fitting complete with 40 mm bore complete all as specified and directed by Engineer-in-Charge.
40
-
-
Taking down unserviceable street light fitting upto 11 mtrs /LED Street Light fitting/Flood light Fitting of any size from the pole/bldg and kept in safe custody for refixing or for schedule of credit to contractor complete all as specified and directed by Engineer-in-Charge. Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost
100
-
-
Refixing and reconnecting up complete LED street light/Flood light fitting after rectification of defects in wiring of the fitting and making electric connection with PVC unsheathed wire with old or new conductor with OH line or Bus bar box complete all as specified and directed by Engineer-in-Charge.
Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost
70
-
-
Supply and fixing automatic street light prewired switch using nature switch for automatic switching of street light based on lux level of nature light.THE SENSOR (NATURE SWITCH) alongwith power contactor for 25 KW 3 phase,MCB pole/wall mountable enclosure made of rust proof electric shock proof terminal proof and FR grade special moulding compound junction box confirming to IP54 with all other accessoried ie lugs cable connedtion etc complete all as specified and directed by Engineer-in-Charge.
2
-
-
Supply and fix in replacement post top lantern LED 40 W or next highest wattage having IP65 protction for single phase connection 50 Hz 230 Volts complete all as specified and directed by Engineer-in-Charge.
8
-
-
Supply and fix of 70/72W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed by Engineer-in-Charge.
30
-
-
All as per item No 77 above but 120 Watt
12
-
-
Supply and fixing LED Flood Light fitting 45 Watt including lamp 45 Watts, IP 66, having pressure die cast aluminium housing with heat resistant toughened glass complete making connection with street light box or OH line using PVC insulated and overall sheathed twin core multi stranded aluminium conductor cable of size 2.5 Sqmm including taking out old unserveceable fitting any type any make complete all as specified and directed by Engineer-in-Charge.
50
-
-
Supply and fixing LED Flood Light fitting 60 Watt including lamp 60 Watts, IP 66, having pressure die cast aluminium housing with heat resistant toughened glass complete making connection with street light box or OH line using PVC insulated and overall sheathed twin core multi stranded aluminium conductor cable of size 2.5 Sqmm including taking out old unserveceable fitting any type any make complete all as specified and directed by Engineer-in-Charge.
25
-
-
Supply and fix in replacement LED bollard fitting 9 Watt with luminaire with MS Pipe housing with glare free PMMA diffuser , IP65 of height 800 mm suitable for single phase connection 50 Hz 230 Volts complete all as specified and directed by Engineer-in-Charge.
20
-
-
Supply and fix single phase driver for LED street light / flood light of 45 to 200 watt capacity and compatible with existing street light/ flood light any type / any rating including taking down old u/s complete all as specified and directed by Engineer-in-Charge.
40
-
-
Supply and fix bracket for street light fitting made out of 40 mm dia GI pipe light grade 1.2 mtr long each bent to required shape & size as directed by EIC & fixed to pole with and including flat iron clamps 02 Nos made out of 32X 6mm flat iron including GI nuts, bolts &washer and painting of clamps and street light firtting bracket with one coat of red oxide primer, one under coat and one finishiung coat with alumminium paint complete all as specified and directed by Engineer-in-Charge.
40
-
-
Supply and fix as in reapir / replacement of pole mounted street light factory fabricated junction box of size 260 x 120 x 230 mm of approved make and of appropriate size made out of 2 mm thick CRCA powder coated sheet , including 63A Single Phase two wire having two no.AL Bus Bar including 6A SP MCB. The box should have auto Door Lock facility with magnetic Lock having Size box fixed on pole using necerssary fixing arrangement such as clamps,nut,bolts and washer including taking down existing junction box of any description/type etc complete all as specified and directed by Engineer-in-Charge.
100
-
-
Supply and fix as in reapir / replacement of pole mounted street light factory fabricated junction box of size300 x 160 x 250 mm mm of approved make and of appropriate size made out of 2 mm thick CRCA powder coated sheet , including63A ,Three Phase four wire having four no.AL Bus Bar including 6A SP MCB. The box should have auto Door Lock facility with magnetic Lock having Sizehaving Size box fixed on pole using necerssary fixing arrangement such as clamps,nut,bolts and washer including taking down existing junction box of any description/type etc complete all as specified and directed by Engineer-in-Charge.
50
-
-
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 16 to 35 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
3
-
-
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 70 to 95 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
3
-
-
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 95 to 120 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
2
-
-
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 120 to 240 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
6
-
-
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 300 to 400 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
2
-
-
Supply,Laying,Connecting and testing in repairs cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 35 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
300
-
-
All as per item No 91 above but Size 25 sqmm 4 core
200
-
-
All as per item No 91 above but Size 16 sqmm 4 core
200
-
-
All as per item No 91 above but Size 10 sqmm 4 core
200
-
-
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 4 core 10 sq. mm nominal cross section in service connections including takind down old u/s complete all as specified and directed by Engineer-in-Charge.
150
-
-
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 2 core 6 sq. mm nominal cross section in service connections including taking down old u/s complete all as specified and directed by Engineer-in-Charge.
200
-
-
Excavation in trenches n exc 1.5 m wide & n exc 1.5 mtr deep in soft/lose soil for taking out pipe & laying of pipe & getting out for diverting of pipe line complete all as specified and directed by Engineer-in-Charge.
150
-
-
Returning, filling in, including spreading, leveling, watering & well ramming in layers n. exc 25 cm thick complete all as specified and directed by Engineer-in-Charge.
120
-
-
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
30
-
-
M & L for brick protection with sub class 'B' bricks laid dry flat over electric cable in trenches complete all as specified and directed by Engineer-in-Charge.
600
-
-
Material and labor for sand cushioning to XLPE cable with using clean dry and natural river sand with a layer of 8 cm thick before laying the cable and 15 cm thick layer after laying the cable and this then gently punned down to a thick of 10 cm above the top the upper most cable complete all as specified and directed by Engineer-in-Charge.
35
-
-
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm complete all as specified and directed by Engineer-in-Charge.
3200
-
-
Material and labour for draining out sedimentation sludgy water from RCC Semi-Ground Sump 70,000Ltr capacity -01 No incl scrapping out sticken forieign material from inner side of Semi UG sump walls/Ceiling by wire brush and removing excavated sedimentatation manually and depositing 50 mtr away fromSump and flushing out the floor with fresh water till satisfaction of Engineer in Charge providing two coats of white wash on old prepared surface cleaning of after completely draining out water from the tank.Writing of cleaning date on the tank complete all as specified and directed by Engineer-in-Charge. The cost of the same shall be deemed included in the respective items. Note : All T&P , safety equipments required for the cleaning of tanks / sumps will be arranged by the contractor.
1
-
-
Material and labour for draining out sedimentation sludgy water from RCC Under Ground Sump 30,000Ltr capacity -01 No incl scrapping out sticken forieign material from inner side of UG sump walls/Ceiling by wire brush and removing excavated sedimentatation manually and depositing 50 mtr away fromSump and flushing out the floor with fresh water till satisfaction of Engineer in Charge providing two coats of white wash on old prepared surface cleaning of after completely draining out water from the tank.Writing of cleaning date on the tank complete all as specified and directed by Engineer-in-Charge.The cost of the same shall be deemed included in the respective items. Note : All T&P, safety equipments required for the cleaning of tanks / sumps will be arranged by the contractor.
1
-
-
Supply and fixing in repair/replacement of solar street light fittings with integrated 12 Watt LED street light system with solar PV Panel 100 WP, integrated LED fitting with Li-Ion Battery 11.1 V 17 Ah , MPPT based solar charge controller,Motion Sensor and tubular pole of height 5 Mtrs complete all as specified and directed by Engineer-in-Charge.
4
-
-
Supply and fix in replacement hot dip galvanized decorative pole 6 m height dual arm light fitting outdoor type including 50 watt luminaire with IP66 rating complete all as specified and directed by Engineer-in-Charge.
4
-
-
M&L for servicing and maintenance of high mast pulley and GI wire rope system oilling, greasing etc for smooth functioning of the lowering mechanish complete all as specified and directed by Engineer-in-Charge.
2
-
-
Supply and fix in replacement of Onload Changover switch 200 Amp, 4 pole ,415 V,50 Hz in sheet metal enclosure complete all as specified and directed by Engineer-in-Charge.
1
-
-
Supply and install and commmissionng of LT bus bar chamber CPRI approved out door type with sloping canopy of size 600x600x600mm made out of 3.15 mm thick CRCA sheet, panel shall be powder coated siemens grey shade mounted on 40x40x6 mm MS angle iron frame 90 cms height erected in ground with PCC foundation 1:4:8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 200 mm length respectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 200 Amps,3 pole ,415 mps, 50 Hz of breaking capacity 25 KA as incomer complete all as specified and directed by Engineer-in-Charge.
4
-
-
Supply and install and commmissionng of LT bus bar chamber CPRI approved out door type with sloping canopy of size 600x600x600mm made out of 3.15 mm thick CRCA sheet, panel shall be powder coated siemens grey shade mounted on 40x40x6 mm MS angle iron frame 90 cms height erected in ground with PCC foundation 1:4:8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 200 mm length respectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 63 Amps,3 pole ,415 mps, 50 Hz of breaking capacity 25 KA as incomer complete all as specified and directed by Engineer-in-Charge.
6
-
-
Supplying, erecting, testing and commissioning of Microprocessor based AMF panel suitable for diesel generating set of 75 KVA capacity three phase 415 Volts, 50 HZ AC including internal wiring with suitable copper conductor with thimbles, timer, relay, MCB 7 Nos- 10 Amps, VMR 3 pole - 02 Nos, battery charger 12 V - 01 No, Motorised changeover switch CX3 160 Amps, Volt meter/Ammeter, RYB phase indicators(DG and Mains), selector switchs etc including fixing with PCC work in floor alongwith suitable angle iron frame for AMF panel complete with all standard features, safeties etc., complete all as specified and directed by Engineer-in-Charge.
1
-
-
Supply, installing testing and commissioning in replacement of factory made and tested (Including CPRI test cetified) outdoor of size 1050mmx1000mmx350mm(approx) type floor mounted LT panel board, cubical type suitable for 415 Volts 3 phase, 4 wire 50Hz, Ac supply system having busbar chamber with insulated AL busbar of rating 1.5 times the incomer MCCB for phase installed on porcelin/SMC insulators. The panel shall be dust and vermin proof IP-64 class protection and made out of 3.15 mm thick CRCA MS sheet and angle iron frame 40x 40x 6mm thick frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with aproaches for cable entry with double door shutter and locking arrangements including internal wiring with PVC insulated stranded copper conductor cable FRLS IS 694 sheathed 1100V grade of appropriate size comprising of following:-
INCOMING-
(i) Mains MCCB 4 pole 200 Amps 50 KA with adjustable setting, 415 Volts with breaking capacity 36 KA. -01 No.
(ii) Digital type voltmeter 0-500 volts and with selector switch-01 No.
(iii) Digital Amp meter with CTs & built in selector switch-01 No.
(iv) Indication lamp RYB-01 Set.
OUTGOING-
(i) MCCB 3 pole 125 Amps,, 415 Volts with breaking capacity 36 KA.-01 No.
(ii) MCCB 3 pole 63 Amps, 415 Volts with breaking capacity 25 KA.-01 No.
(iii) MCB SPN 32 Amps -2 Nos
Note : MCCBs shall have adjustable thermal setting. All kA values indicates shall be lcs breaking capacity. General arangement drawings shall be got approved by GE before fabrication.
2
-
-
Supply,installation,commissioning and testing as in replacement of street light panel (Timeline LT distribution board) of time line rating 40A single Pole/ 230 V,floor mounted factory fabricated weather and vermine proof protection class IP 54, protection from over load and short circuit. Switch On -Off street light on time schedule by incorporating an Ashtronomical time switch complete all as directed including required earth / excavation etc complete including taking out existing LT panel of any size complete all as specified and directed by Engineer-in-Charge.
2
-
-
Supply,installation,commissioning and testing as in replacement of street light panel (Timeline LT distribution board) of time line rating 63 A single Pole/ 230 V,floor mounted factory fabricated weather and vermine proof protection class IP 54, protection from over load and short circuit. Switch On -Off street light on time schedule by incorporating an Ashtronomical time switch complete all as directed including required earth / excavation and taking out existing LT panel of any size complete all as specified and directed by Engineer-in-Charge.
3
-
-
Material and labour for writing letters or figures (Block, Roman, Italic or Indian) LT Pole No ___ or HT Pole No ____ , S/L Pole No _______ and Location code not exceeding 30 cm high , stop, commas, short lines, dashes, hypens, brackets etc complete all as specified and directed by Engineer-in-Charge.
Note : 10 No letters, figures and 10 No Stops, commas & short lines included in each job.
150
-
-
S&F water level indicator for underground sump, water level display wired sensor security system with alaram system having power input 230V,50 Hz, including electrical cable complete all as specified and directed by Engineer-in-Charge.
1
-
-
Material and labour for GI pipe, medium grade, both end flange welded, 3.0 metre long including nut, bolt, MS washers and rubber gaskets and lowering in borewell with pump and all conncetions including taking down complete all as specified and directed by Engineer-in-Charge.
-
-
-
All as per item No 117 above but 100 mm
50
-
-
All as per item No 117 above but 80 mm
50
-
-
All as per item No 117 above but 50 mm
50
-
-
Supply and fixing in replacement of unserviceable GI tubing medium grade with all fittings complete laid in trenches / on walls / on ceiling / roof etc incl necessary suitable size of MS clamps / saddling on walls / ceiling etc including taking down complete all as specified and directed by Engineer-in-Charge.
-
-
-
All as per item No 121 above but 100 mm dia.
80
-
-
All as per item No 121 above but 50 mm dia.
250
-
-
All as per item No 121 above but 40 mm dia.
100
-
-
Supply laying and testing of Ductile Iron pipes in replacement of unserviceable CI pipe of 80 mm bore with spigot and socket ends centrifugal cast, class K-7 as per IS 8329 in any length suitable for and including rubber tightening joints laid in trenches including taking down complete all as specified and directed by Engineer-in-Charge.
100
-
-
Supply and fix connected Gun metal gate valve ISI marked with iron wheel head screwed both ends for iron pipes and fixed for the following sizes including taking down of unserviceable gate valves complete all as specified and directed by Engineer-in-Charge.
-
-
-
All as per item No 126 above but 50 mm dia.
3
-
-
All as per item No 126 above but 25 mm dia.
5
-
-
All as per item No 126 above but 20 mm dia.
3
-
-
All as per item No 126 above but 15 mm dia.
5
-
-
S& F fully automatic star delta starter for submersible pump motor,415 Volt,3 phase,20 HP capacity,over load relay range 12-18 seconds,contrctor size 18, standard coil voltage 260V-415V AC complete all as specified and directed by Engineer-in-Charge.
1
-
-
S& F fully automatic star delta starter for submersible pump motor,415 Volt,3 phase,7.5 HP capacity,over load relay range 12-18 seconds,contrctor size 18, standard coil voltage 260V-415V AC complete all as specified and directed by Engineer-in-Charge.
1
-
-
Trimming up of tree branches upto 3mtr all around HT/LT overhead lines,removing cut branches from complete all as specified and directed by Engineer-in-Charge.
Note:-(i) The overhead lines will be kept clear fromall trees by trimming of tree branches with 3 mtr all around the line. Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shutdown of that area will be arranged by department. (ii) Total length of line from supply point to load end will be measured for the purpouse of payment, irrespective of the no of trees required to be trimmed
10
-
-
M&L for chemical and micro biological test of water from NABL approved test lab for bore well and RO plant and test report to be submitted by the contactor complete all as specified and directed by Engineer-in-Charge.
2
-
-
Supply and replacement of Bty 12 Volt 80 AH suitable DG set complete all as specified and directed by Engineer-in-Charge.
1
-
-
Taking out existing unserviceable/ broken / damaged CI sluice valve from its existing position and Supply & fixing CI sluice valve stainless steel, spindle CI body class –I, PN-1.6 ISI marked both end flanged and drilled and fixed by means of new nuts, bolts and washer including providing rubber gasket of suitable thickness of following sizes complete all as specified and directed by Engineer-in-Charge.
-
-
-
All as per item No 136 above but 100 mm dia bore of pipe
3
-
-
All as per item No 136 above but 80 mm dia bore of pipe
3
-
-
All as per item No 136 above but 50 mm dia bore of pipe
1
-
-
M&L construction of brick masonary valve pit/ chamber of size internal dimension of 900X900X1200 mm size (Type "B") brick masonry built in CM(1:4) with MS cover 3 mm thick and angle iron frame 40 x 40 x 5 mm with locking arrangement including excavation and earth work in any type of soil, PCC (1:4:8) type D-2 for foundation, PCC bed/coping in cement concrete (1:2:4) type B1,plastering 15 mm thick in CM (1:4), painting with one coat of red oxide primer and 2 coats of bituminous black paint on all steel surface complete all as specified and directed by Engineer-in-Charge.
2
-
-
M&L construction of brick masonary valve pit/ chamber of size internal dimension of 900X900X900 mm size (Type "B") brick masonry built in CM(1:4) with MS cover 3 mm thick and angle iron frame 40 x 40 x 5 mm with locking arrangement including excavation and earth work in any type of soil, PCC (1:4:8) type D-2 for foundation, PCC bed/coping in cement concrete (1:2:4) type B1,plastering 15 mm thick in CM (1:4), painting with one coat of red oxide primer and 2 coats of bituminous black paint on all steel surface complete all as specified and directed by Engineer-in-Charge.
4
-
-
M&L construction of brick masonary valve pit/ chamber of size internal dimension of 900X600X600 mm size (Type "B") brick masonry built in CM(1:4) with MS cover 3 mm thick and angle iron frame 40 x 40 x 5 mm with locking arrangement including excavation and earth work in any type of soil, PCC (1:4:8) type D-2 for foundation, PCC bed/coping in cement concrete (1:2:4) type B1,plastering 15 mm thick in CM (1:4), painting with one coat of red oxide primer and 2 coats of bituminous black paint on all steel surface complete all as specified and directed by Engineer-in-Charge.
4
-
-
M&L in replacement Air termination franklin typr ,copper rod 12mm dia and 300mm long complete all as specified and as directed complete all as specified and directed by Engineer-in-Charge.
35
-
-
M&L in replacement Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors including saddles,insulator, nut & bolts brazing etc above ground complete all as specified and directed by Engineer-in-Charge.
200
-
-
M&L in replacement GI 32 x 6mm with saddles and fixing screws etc. for roof conductors and down conductors including saddles,insulator, nut & bolts brazing etc above ground complete all as specified and directed by Engineer-in-Charge.
200
-
-
M&L in replacement Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by Engineer-in-Charge.
10
-
-
M&L for preparation of external surface LT Panel/Feeder piller rubbing the rusted surface and painting with two coats of spray paint with synthetic enamel paint over a coat of metal primer matching with existing colour complete all as specified and directed by Engineer-in-Charge.
10
-
-
M&L for Removing all connections from LT panel having feeders upto 04 Nos ( Total of incoming and outgoing) , any capacity, indoor or outdoor type, fpr repairs/ servicing. Cleaning properly all parts and removing dust, carbon deposits etc. Removing U/S thimbles if any of connections. Refixing serviceable items to the panel and making all connections including testing for proper functioning of the panel as per standard engineering pactice complete all as specified and directed by Engineer-in-Charge. ( U/S items will be provided against respective items separately.
5
-
-
M&L for Removing all connections from LT panel having feeders above 04 Nos upto 08 Nos ( Total of incoming and outgoing) , any capacity, indoor or outdoor type, fpr repairs/ servicing. Cleaning properly all parts and removing dust, carbon deposits etc. Removing U/S thimbles if any of connections. Refixing serviceable items to the panel and making all connections including testing for proper functioning of the panel as per standard engineering pactice complete all as specified and directed by Engineer-in-Charge. ( U/S items will be provided against respective items separately.
4
-
-