Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Civil And Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 Nov 2024
Closing Soon7 Jan 2025
Tender Amount₹ 36,60,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
OUTGOING :- (i) MCCB 4 pole 415 V breaking cap 16 KA, current rating 100 Amps along with sprader terminals. - 02 Nos (ii) MCCB 4 pole 415 V breaking cap 16 KA, current rating 63 Amps along with sprader terminals. - 01 Nos (iii) MCCB 4 pole 415 V breaking cap 16 KA, current rating 40 Amps along with sprader terminals. - 03 Nos & One (1) No. 40A, 3 phase Timer Switch for automatic operation. (iv) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint (vi) Indicating Lamps R Y B , LED type 01 set

-

-

-

... More
Taking out old rusted unserviceable LT panel Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm). INCOMING :- (i) Incomer of the panel having MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA with microprocessor release - 01 Nos along with sprader terminals , Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 400/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 400 Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No (iv) Indicating Lamps : 01 set

1

-

-

... More
OUTGOING :- (i) MCCB 4 pole 415 V breaking cap 16 KA , current rating 100 Amps along with sprader terminals. - 01 Nos (ii) MCCB 4 pole 415 V breaking cap 16 KA , current rating 63 Amps along with sprader terminals. - 03 Nos (iii) MCCB 4 pole 415 V breaking cap 16 KA , current rating 40 Amps along with sprader terminals. - 04 Nos & One (1) No. 40A, 3 phase Timer Switch for automatic operation. (iv) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint (vi) Indicating Lamps R Y B , LED type 01 set

-

-

-

... More
M&L in replacement of Earthing complete with GI strip of size 32x6 mm thick earth plate electrode 600 x 600 x 6mm thick, buried directly into ground vertically not less than 2.25 Mtr below the ground level with top edge of the earth plate to a depth not less than 1.5 Mtr below the ground level, including GI protection pipe 40 mm bore light grade connected from electrode up to test point including necessary earth work, PCC/RCC chamber cover 50mm thick in RCC 1:2:4 type B1 with 8mm TMT bars 15 cm c/c both ways, funnel arrangement etc as per electrical plate No 3 of SSR part I Note : Rate shall be deemed to be inclusive of necessary excavation and earth work in any type of soil, removal of surplus soil to a distance not exceeding 50m, RCC cover slab and PCC chamber etc.GI strip upto 7.5 mtr lenght will be included in quoted rate.

6

-

-

... More
Taking out carefully LT cable of size 120 sqmm to 70 Sqmm 3.5 core from trench complete all as specified and directed by Engineer-in-Charge.

1080

-

-

... More
Taking out carefully LT cable of size 50 sqmm to 16 Sqmm 4 core from trench complete all as specified and directed by Engineer-in-Charge.

2080

-

-

... More
Supply and laying 120 Sqmm 3.5 Core XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked as per IS 7098-1 laid in trenches ducts or fixing or passing through GI pipe across the road/path/drains/ along wall / floor / equipment etc complete all as specified and as directed by Engineer-in-Charge. Note :- Excavation earth work sand cushioning brick protection, pipe shall be measured and paid separately.

400

-

-

... More
All as per item No 07 above but of size 3.5 Core 95 Sqmm

325

-

-

... More
All as per item No 07 above but of size 3.5 Core 70 Sqmm

355

-

-

... More
All as per item No 07 above but of size 3.5 Core 50 Sqmm

325

-

-

... More
All as per item No 07 above but of size 3.5 Core 35 Sqmm

860

-

-

... More
All as per item No 07 above but of size 4 Core 25 Sqmm

125

-

-

... More
All as per item No 07 above but of size 4 Core 16 Sqmm

770

-

-

... More
M&L for boring of holes under road, pavement, hard standing by manual means for laying cable through HDPE pipe of suitable size complete all as specified and as directed by Engineer-in-Charge.

48

-

-

... More
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed by Engineer-in-Charge. Note:-(i) The contractor will be responsible for taking permission from appropriate authority i.e. NHAI / IGL or other Units , if needed, for above said work. (ii) Depth of Trench Less shall not less than 2 mtr from ground level unless other wise specifed due to site requirement and contractor has to maintain the depth of trenchless up to 4 mts from ground level if required as per site conditions all rates quoted shall be demeed to be included to maintain the Trench less depts as directed during exection to avoid damages to the existing services (iii) The cost quoted is deemed to be inculded for repiars / rectification for damages done to the existing elecrtical / comminication and water supply system / Sewage System during execution of work.

55

-

-

... More
M&L for laying HDPE pipe of 100 mm dia suitable for 0.4 mpa working pressure under road, pavement, hard standing for laying cable through it complete all as specified and as directed by Engineer-in-Charge.

48

-

-

... More
M&L for excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation laying of pipe etc and not exceeding 10 sqm on plan for manhole etc and getting out in soft /loose soil complete all as specified and as directed by Engineer-in-Charge.

652.9

-

-

... More
M&L for excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in hard rock for laying of cables and getting out and levelling of bottom surface to required level complete all as specified and as directed by Engineer-in-Charge.

119.34

-

-

... More
M&L for returning filling in with approved excavated soil including spreading levelling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed by Engineer-in-Charge.

447.25

-

-

... More
M&L for removing excavated material (Soils) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge.

324.86

-

-

... More
Supply and laying Class LV tiles type-1 flat size 250x150x40mm laid in trenches for cable protection etc complete all as specified and as directed by Engineer-in-Charge.

8593

-

-

... More
M&L for dry Sand Cushioning to under ground electric cable one layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable complete all as specified and as directed by Engineer-in-Charge.

231.66

-

-

... More
Supply and laying of sub class B bricks having minimum compressive strength 75Kg/sqm (230 x 115 x 75mm) laid in trenches for cable protection etc complete all as specified and as directed by Engineer-in-Charge.

13.6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.