If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair Maint To Roof Treatment Chajjas Parapet Wall
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_668615_1Bid Award Id
ViewTender No
GE/SP/TOKEN-28/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M&L for PCC 1:2:4 type B1 using 20mm graded aggregate mixed with water proofing compound as per manufacturer instructions laid 40mm avg thickness as in padding over roof slabs for providing proper slope to the concrete padding, surface finished even and smooth without using extra cement complete all as specified and directed
36
-
-
M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatement complete all as specified and directed by Engineer-in-Charge.:-
(a) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered roof surface.
(b) Applying evenly a tack coat of bitumen 85/25 grade @1.20 kg/ sqm.
(c) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HM-HDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc.
(d) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame.
Note:- This treatement shall be done by the approved authorized applicators and guarantee of treatement shall be minimum 10 years complete all as specified and directed
940
-
-
M&L for two coats of aluminium paint incl preparation of newly or previously untreated surfaces of any description, over 10cm width or girth, not otherwise described complete all as specified and directed
340
-
-
M&L for cement concrete tiles 20cmx20cmx20mm thick, with grey cement and no pigment; machine pressed; set, jointed and pointed in net cement slurry in floor/roof slab and cut and polished incl over 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed
600
-
-
Dismantling brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work and precast concrete articles and incl M&L for Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed.
6
-
-
Taking down cement plaster of any description on brick or concrete surfaces of walls or ceiling etc incl. raking out joints ,hacking for key and scrubbing down with water upto 4 storeys building, complete all as specified and directed
1150
-
-
M&L for 15 mm thick cement plaster in cement mortar 1:4 on concrete or brick surface and finished even and smooth w/o using extra cement upto 4 storeys building with water proofing compound as per manufacture instructions complete all as specified and directed
400
-
-
M&L for 10 mm thick cement plaster in cement mortar 1:6 on brick surfaces on fair face of brick work and finished even and smooth w/o using extra cement complete all as specified and directed
600
-
-
M&L for 5 mm thick cement plaster in cement mortar 1:3 on concrete or brick surface and finished even and smooth w/o using extra cement as in ceiling complete all as specified and directed
150
-
-
M&L for preparation of new plastered surfaces of wall and applying two coats exterior emulsion over a coat of exterior primer, complete all as specified and directed
400
-
-
M&L for preparation of new surface and applying two coats of oil distemper on wall incl priming coat of alkali resistant priming paint over a coat of wall care putty complete all as specified and directed
600
-
-
M&L for preparation of new surface and applying three coat of white wash on ceiling, complete all as specified and directed
150
-
-
Demolition of cement concrete in reinforced (reinforcement cut as required to facilitate demolition) Roofs, floors, beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
1.8
-
-
M&L for Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings, counter shelve and similar works : not exceeding 200mm thick (horizontal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed.
16
-
-
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking,bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed)not less than 0.9mm dia or securing with clips complete all as specified and directed.
200
-
-
M&L for RCC type B1, 1:2:4 (20mm graded aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves, chajjas and the like complete all as specified and directed.
1.8
-
-
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
5.6
-
-
S&F for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165. Complete all as specified and directed.
180
-
-
S&F Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats, etc. FE 410-W (Gde- E-250) quality A, complete all as specified and directed
380
-
-
M&L for Preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
18
-
-
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings. complete all as specified and directed.
60
-
-
M&L for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
40
-
-
M&L for Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick in ridges of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
20
-
-
Taking down frame or Chowkhats with shutters (without taking off shutters from the frames) of any description not exc.1.50 Sqm each incl necessary repair to opening with CM 1:4 complete all as specified and directed
60
-
-
Taking down frame or Chowkhats of any description exc 1.5 but n. exc. 4 Sqm each incl necessary repair to opening with CM 1:4 complete all as specified and directed
10
-
-
S&F window/Ventilator section of frame 72x55 mm fixed to wall or concrete surface with MS hold fast (30x5 mm section) 150 mm long made of galvaniszed steel powder coated and section of shutter 47x20 mm, mulion section 72x50 mm (base steel as per IS 513 'D' quality galvanzed as per IS 277 with zinc of 120 gms/Sqm) glazed or gauzed and wire gauze shutter prepare to receive wire mesh to the shutter (Double door shutter) with total coated thickness of 0.60 mm including poweder coated grill/guard bars made of square bars 10 mm dia at 150 mm c/c horizontal spacing fixed in MS flat frame (30x5 mm) fixed to windows frame with screws, including 4 to 5 mm thick sheet glass, 0.36 mm stainless steel wire cloth with 1.40 mm aperture necessary fittings and all builders hardware such as handles, tower bolts & stays etc complete all as specified and directed by Engineer-in-charge. Type-4000 series ref drg No CEAF/STD-191/2014 SH1/2&2/2.
67
-
-
S&F Solid PVC Door Frame of size (50x47)mm made out of 5mm single side prelam PVC sheet reinforced with M.S. Square tube, complete all as specified and directed
49
-
-
S&F Factory Made Solid PVC Moulded Door Shutter with Particle Board Core, 28 to 30mm thick (stiles), with 2 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, complete all as specified and directed
16
-
-
S&F 100mm long Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed
30
-
-
S&F 100mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed
20
-
-
S&F 125mm long Aluminium alloy handles of extruded section fabricated type anodised and fixed, complete all as specified and directed
20
-
-
Taking down Door shutter of any description exc.1.0 Sqm but n exc 2.5 Sqm each incl necessary repair to opening with CM 1:4 complete all as specified and directed
10
-
-
S&F 30 mm thick Flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides, complete all as specified and directed
21
-
-
M & L for preparing surfaces of new wood and wood based materials of any description and girth, not otherwise described and treated with two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed
50
-
-
S&F 125mm long Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed
30
-
-
S&F 125mm long mild steel barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and directed .
20
-
-
S&F 150mm long Aluminium alloy handles of extruded section fabricated type anodised and fixed, complete all as specified and directed
20
-
-
S&F 250mm long mild steel sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and directed
20
-
-
Dismantling of floor, hearth or wall tiling including cement mortar bedding/backing etc, removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed
182
-
-
M&L for vitrified ceramic tiles (light shades) of 10 mm thick polished area of each tile n.exec.36 Sqm laid as in floors setting and jointed with cement slurry over & including 15 mm thick screed bedding layers of cement sand mortar ( 1:4) and pointed with coloured cement to match with surfaces of tiles complete all as specified and das directed by Engr-in-Charge.
60
-
-
All as per item No 43 above but on vertical surface such as dado/skirting, including Rendering/backing 10mm thick in CM 1:4 on brick wall surfaces, other than fair faces of brick work finished even and fair to receive tiles, complete all as specified and directed by Engr-in-charge.
12
-
-
M&L for Non-skid coloured ceramic tiles, 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18sqm, in floors/wall etc, set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles laid over including 15 mm thick screed bead in CM 1:4, complete all as specified and directed
30
-
-
M&L for Glazed ceramic coloured tiles of size (350x250x7)mm/ (450x350x7)mm thick on vertical surface such as in dado/skirting/risers to steps etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles and including 10 mm thick backing coat in CM (1:4) complete all as specified and directed
80
-
-
S&F 15mm bore steel water tubing medium grade, galvanized ISI marked with all fittings fixed to wall & ceiling or laid in floors, Including taking down steel tubing or removing from site, complete all as specified and directed
90
-
-
S&F 20mm bore steel water tubing medium grade, galvanized ISI marked with all fittings fixed to wall & ceiling or laid in floors, Including taking down steel tubing or removing from site, complete all as specified and directed
120
-
-
Dismantling existing water tank and removing from site and S&F Rotational moulded PVC water tanks of 500 Ltr capacity, cylindrical vertical with closed top hoisted and fixed in position including complete all as specified and directed
6
-
-
Dismantling existing water tank and removing from site and S&F Rotational moulded PVC water tanks of 1000 Ltr capacity, cylindrical vertical with closed top hoisted and fixed in position including complete all as specified and directed
8
-
-
S&F ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed suitable for iron pipe 20mm bore having weight not less than 210 gms complete all as specified and directed
14
-
-
Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc. of capacity exc 250 ltr and n. exc. 500 ltr and writing of date of tank cleaning on tank by white paint complete all as specified and directed
100
-
-
Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc. of capacity exc 500 ltr and n. exc. 1000 ltr and writing of date of tank cleaning on tank by white paint complete all as specified and directed
32
-
-
S&F in repair for vitreous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed
6
-
-
S&F in repair vitreous china squatting pan “orrisa” pattern of size 580mmx440mm “white” with integral foot rest (excluding flushing cistern and flush pipe) incl provision of cement concrete bedding, ‘P’ trap 110mm dia connection to trap and flushing pipe, anti-syphonage complete all as specified and directed
4
-
-
S&F in repair PVC flushing cistern of 10 ltr capacity valveless, symphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including flush pipe of 32mm bore PVC and 15mm bore PVC connection 450mm long to pipes etc and taking down existing flushing cistern complete all as specified and directed.
10
-
-
S&F in repair PVC waste pipe 32mm bore, 0.90 m long complete all as specified and directed
200
-
-
S&F in repair PTMT long body bib tap 15mm dia pipe with crutch or butter fly handle screwed down, screwed for iron pipe and fixed. Complete all as specified and directed.
100
-
-
S&F in repair PTMT stop cock 15mm dia pipe with screwed for iron pipe and fixed. Complete all as specified and directed.
50
-
-
Taking up or down CI/PVC pipes (incl all fittings), with spigot and socket ends and lead joints incl burning out joints and removing lead of 110/75mm dia pipe complete all as specified and directed
160
-
-
S&F PVC (SWR) pipes 110 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts etc. Complete all as specified and directed.
80
-
-
S&F PVC SWR bends 110 mm dia . Complete all as specified and directed.
20
-
-
S&F 110 mm PVC (SWR) branch piece, single (single Y) equal or unequal. Complete all as specified and directed.
30
-
-
S&F PVC (SWR) pipes 75 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts etc. Complete all as specified and directed.
80
-
-
S&F PVC SWR bends 75 mm dia . Complete all as specified and directed
20
-
-
S&F 75 mm PVC (SWR) branch piece, single (single Y) equal or unequal
30
-
-
S&F in repair PVC (SWR) floor trap, size 75mm, plain with grating including jointing with solvent cement, complete all as specified and directed
10
-
-
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided. Complete all as specified and directed.
3.2
-
-
M&L for Cement concrete (1:5:10) type E2 using 40 mm graded aggregate as in filling, mass/ cinder concrete, complete all as specified and directed
2.75
-
-
M&L for 25 mm thick PCC 1:2:4, type B-0 using 12.50 mm graded crushed stone aggregates as in floor surfaces, complete all as specified and directed.
10.5
-
-
M & L for providing water proofing treatment to RCC sunken slab as specified and directed as under (a) cleaning the existing RCC sunken slab and vertical wal/ RCC beam and hacking the surface. (b) 15 mm thick plastering over floor & vertical surfaces in 1:4 mixed with liquid water profing compound @ 200 per 50 kg of cement troweled to even and smooth finish without using extra cement. (c) Filling the sunken portion with water for 72 hrs and carrying out the ponding test (Any leakage / seepage noticed shall be repaired). (d) Applying two coats of elastometric acrylic water proof coating with roller application (Note each coat of elastomeric acrylic compound reqiuires 6-8 hrs to dry up itself second coat shall be applied on getting the first coat completely dried up. Min quantity required for coating as per manufacture instruction) complete all as specified & directed
21
-
-
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness below or above ground level, complete all as specified and directed.
6.75
-
-
M&L for 50mm thick Cement concrete type C 2, 1:3:6 (40mm graded aggregate) in sub bases, sub floors, pavings and plinth protection etc. complete all as specified and directed
135
-
-