Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date17 Jan 2025
Closing Date13 Feb 2025
Tender Amount₹ 90,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(b) 100 to 125 KVA Capacity

8

-

-

... More
(c) 50 to 75 KVA Capacity (Note : For serial item no 1.02 to 1.04 Spares parts required shall be measured and paid separately under respective itms of Schedule as supply only.)

6

-

-

... More
Supply only of following items for DG Sets Capacity of 160 KVA to 200 KVA (Required under Sl item No. 1.02 above) :-

-

-

-

... More
Air Filter

4

-

-

... More
Fuel Filter

4

-

-

... More
Lubricating oil filter

4

-

-

... More
Diesel return pipe

4

-

-

... More
Ignition switch for starting DG set with key.

2

-

-

... More
Diesel Fuel Hose pipe from diesel tank to fuel filter

4

-

-

... More
Fuel injector pipe from fuel pump to Injector

3

-

-

... More
Supply only of following items for DG Sets Capacity of 100 ot 125 KVA (Required under Sl item No. 1.03 above) :-

-

-

-

... More
Air Filter

8

-

-

... More
Fuel Filter

8

-

-

... More
Lubricating oil filter

8

-

-

... More
Diesel return pipe

5

-

-

... More
Ignition switch for starting DG set with key.

2

-

-

... More
Diesel Fuel Hose pipe from diesel tank to fuel filter

5

-

-

... More
Fuel injector pipe from fuel pump to Injector

5

-

-

... More
Supply only of following items for DG Sets Capacity of 50 to 75 KVA (Required under Sl item No. 1.04 above) :-

-

-

-

... More
Air Filter

6

-

-

... More
Fuel Filter

6

-

-

... More
Lubricating oil filter

6

-

-

... More
Diesel return pipe

4

-

-

... More
Ignition switch for starting DG set with key.

2

-

-

... More
Diesel Fuel Hose pipe from diesel tank to fuel filter

3

-

-

... More
Fuel injector pipe from fuel pump to Injector

2

-

-

... More
Supply & fixed in repair of Hose pipe set & Clips of water / coolent cooled radiator system for following capacities of DG set :-

-

-

-

... More
50 KVA to 75 KVA DG set

3

-

-

... More
100 KVA to 125 KVA to DG set

3

-

-

... More
160 KVA to 200 KVA DG set

1

-

-

... More
Disconnection and dismantling the fuel injector pump assembly from its original position, repairing & servicing by cleaning / oiling / servicing of fuel injector pump assembly , removing and replacement fuel injector pump repair kit & fuel pipe including calibration complete & refixing the same complete all as specified and directed for following capacities of DG set :-

-

-

-

... More
160 KVA to 200 KVA DG Set

1

-

-

... More
100 to 125 KVA KVA Capacity

2

-

-

... More
50 to 75 KVA Capacity

3

-

-

... More
Dismantling and taking down radiator assy from engine of any capacity of repairs etc transporting of the radiator of capacity upto 200 KVA for repair/maintenance of rediator fins with the help of cleaning coil solution and cleaning to the radiator complete and removing the sediments and scales, corrosion etc by means of acid cleaning and high pressure water washing and air cleaning, repair to the leakage places by means of gas welding and including initial filling up coolant and re fixing after repairs including replacement of worn out nut bolts washers etc and testing complete all as specified and directed

4

-

-

... More
Dismantling the water pump for the DG Set taking out the worn out parts, refixing the water pump after replacing water pump kit set for following capacities of DG set:-

-

-

-

... More
50 KVA to 75 KVA DG set.

1

-

-

... More
100 KVA to 125 KVA DG set.

2

-

-

... More
160 KVA to 200 KVA DG set.

1

-

-

... More
S&F in repair of RPM meter of upto 200 KVA DG set complete all as specified and directed.

3

-

-

... More
S&F in repair of oil pressure Gauge of upto 200 KVA DG set complete all as specified and directed.

5

-

-

... More
S&F in repair of oil temperature Gauge of upto 200 KVA DG set complete all as specified and directed.

5

-

-

... More
S&F in repair of water temperature Gauge of upto 200 KVA DG set complete all as specified and directed.

4

-

-

... More
Taking out following defective parts from Alternator of DG sets and supply and fixing new parts including testing of DG set complete all as directed :-

-

-

-

... More
AVR unit complete suitable for 50 KVA to 75 KVA DG Set

1

-

-

... More
AVR unit complete suitable for 100 KVA to 125 KVA DG Set

2

-

-

... More
AVR unit complete suitable for 160 KVA to 200 KVA DG Set

1

-

-

... More
Disconnection and taking out the turbo charger assembly complete from the Engine of any make of 100 KVA to125 KVA DG Set and taking to workshop, strip opening of turbo charger and replacement of turbo charger repair Kit , assembling the complete part of the turbo charger and fixing back to the engine the testing and commissioning for satisfactory working complete all as specified and directed.

2

-

-

... More
M&L for replacement of fiexible coupling including coupling nuts, bolts & washers etc and proper alignment complete all as specified and directed at site suitable for DG sets of capacity :-

-

-

-

... More
160 to 200 KVA Capacity

1

-

-

... More
100 to 125 KVA Capacity

3

-

-

... More
50 to 75 KVA Capacity

3

-

-

... More
M&L repair/overhauling of self starter 12/24 Volt of any make/Capacity including replacement of minor items such as carbon brushes, nuts blts etc, complete all as specified directed for fully functional of self starter complete. (Note: All additional spares parts as required will be measured and paid separately as supply only)

4

-

-

... More
Supply only spares parts suitable for self starter 12/24 V as mentioned below:-

-

-

-

... More
Field coil

4

-

-

... More
Armature

4

-

-

... More
Clutch assembly

4

-

-

... More
Supply & fix in repair of self starter assembly 24 volt complete for 100 KVA to 125 KVA DG set complete

1

-

-

... More
Supply & fix in repair of self starter assembly 12 volt complete for 50 KVA to 75 KVA DG set complete

1

-

-

... More
M&L cleaning oil fuel tank of DG sets of any make and capacity including replacement of fuel level indicating tube and markings of suitable quantity of OEM recommendation complete all as specified and directed.

12

-

-

... More
M&L painting of DG set with two coats of spray painting by spray machine with synthetic enamel paint as per colour code after preparation of old painted surfaces and writing SM/MES nos etc complete all as specified and directed for the following Capacity :-

-

-

-

... More
100 to 200 KVA Capacity DG Set

5

-

-

... More
50 to 75 KVA Capacity DG Set

2

-

-

... More
50 to 200 KVA capacity DG Set but only inside and outside for the aucustic enclosure of the DG set.

4

-

-

... More
S&F in repair of Battery charger with variable voltage for 12V,upto 180AH battery complete all as specified and directed.

4

-

-

... More
S&F in repair of Battery charger with variable voltage for 2x12V,upto 180AH battery complete all as specified and directed.

4

-

-

... More
M&L battery lead copper conductor 25 Sqmm multi stranded PVC insulated with suitable terminals at both ends as per site requirement complete all as specified and directed.

35

-

-

... More
Supply and replaced 'V belt' as per sample for DG sets of capacity complete all as specified and directed

-

-

-

... More
50 to 75 KVA Capacity

2

-

-

... More
100 to 125 KVA Capacity

3

-

-

... More
160 to 200 KVA Capacity

2

-

-

... More
Dismantling of alternator assembly of DG Set of capacity upto 125 KVA and taking out U/S Exitation winding and rewinding of exitation coil with supper enamelled copper winding complete all as per specified and directed.

2

-

-

... More
Dismantling of alternator assembly of DG Set of capacity exc 125 KVA but upto 200 KVA and taking out U/S Exitation winding and rewinding of exitation coil with supper enamelled copper winding complete all as per specified and directed.

2

-

-

... More
M&L for repairing of canopy of DG set by carrying out repairing of door with replacement of broken hinges including nuts, bolts/welding etc as per requirement, cleaning of base of foundation and painting with black paint MS channel with two coats including touching of paint at cannopy by replacing locking arrangement where required complete all as specified and directed

4

-

-

... More
Draining out the old u/s oil from the engine of DG set of any capacity cleaning the oil chamber and supply and filling new lubricant GENSET OIL complete all as directed and specified. ( Note: Lubricant oil shall be procured from approved make and in sealed container.)

200

-

-

... More
Supply and replacement coolant of approved make suitable for DG sets complete all as directed and specified. (Note: Lubricant oil shall be procured from approved make and in sealed container.)

100

-

-

... More
M & L for for repair of DG Control Panel of any description and in any position of capacity DG Set upto 200 KVA including checking AC/DC circuits, tightning of all power / control wiring connection and replacement of unserviceable control wiring with suitable size, single core, copper conductor, flexible, PVC insulated, unsheathed cable suitable upto 1100 volts confirming to IS-694, taking out, removing and replacement of unserviceable parts / spares / items to makefunctional including testing complete all as specified .

8

-

-

... More
Material and labour for plate earthing with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised earth lead 32mm x 6mm strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all surrounded by adequete quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, earth strip encased in 40 mm bore GI medium grade pipe, including providing watering pipe 20 mm bore GI pipe medium grade from bottom of the earth pit to the top of the electrode complete with earth pit in PCC 1:2:4 type B - O using 12 mm graded crushed stone aggregate, earth work and RCC cover Complete all as specified and shown in electrical plate number 3 of SSR part -1, incl dismantlimg of existing earth pit complete all as specified and directed. (Note: GI earth strip upto 7.5 RM from the test point shall be deemed included in quoted unit rate.)

10

-

-

... More
M&L maintenance/repair at LT Control panel including cleaning in side the panel, tightening of all connection complete installed at pump house for centrifugal pump set/ borewell at different places in the area and replacement of spare parts as required during maintenance. (Note: Spare part will be measured and paid seperately under relevent item as supply only) complete upto 75 HP motor pump set (once in a month) with FASD starter and MCCB.

40

-

-

... More
Material and labour for removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any width or girth from the existing suction/ delivery pipe line including headers of any size and applying of painting to existing surcface by using spray gun with one coat of red oxide and two coat of synthetic enamel paints on existing suction/ delivery pipe lines, including Headers of any size using Blue/Red/Black colour as per site requirement complete all as specified and as directed.

400

-

-

... More
S&F in replacement moulded case circuit breakers 4 Pole 415 Volt adjustable type 350 Amp with breaking capacity 36 KA complete all as specified and directed

3

-

-

... More
S&F in replacement moulded case circuit breakers 4 Pole 415 Volt adjustable type 250 Amp with breaking capacity 36 KA. complete all as specified and directed

4

-

-

... More
S&F in replacement moulded case circuit breakers 3 Pole 415 Volt adjustable type 200 Amp with breaking capacity 36 KA. complete all as specified and directed

4

-

-

... More
S&F in replacement moulded case circuit breakers 4 Pole 415 Volt adjustable type 160 Amp with breaking capacity 36 KA. complete all as specified and directed

4

-

-

... More
S&F in replacement moulded case circuit breakers 3 pole 125 Amps having breaking capcity 16 KA at 415 volts. complete all as specified and directed

5

-

-

... More
Supply & Fixing in replacement MCCB 200 Amp 415 Volts, 36 KA, 4 pole, 50 Hz, with adjustable thermal & fixed magnetic setting complete all as specified and as directed.

4

-

-

... More
Supply & Fixing in replacement MCCB 100 Amp 415 Volts, 16 KA, 4 pole, 50 Hz, with fixed thermal & fixed magnetic setting complete all as specified and as directed.

4

-

-

... More
Supply & Fixing in replacement MCCB 63 Amp 415 Volts, 16 KA, 4 pole, 50 Hz, with fixed thermal & fixed magnetic setting complete all as specified and as directed.

5

-

-

... More
S&F in replacement moulded case circuit breakers 3 pole 100 Amps having breaking capcity 16 KA at 415 volts. complete all as specified and directed

5

-

-

... More
S&F in replacement moulded case circuit breakers 3 pole 63 Amps having breaking capcity 16 KA at 415 volts complete all as specified and directed

8

-

-

... More
S&F in replacement offload changeover switch 4 pole 100 Amps in sheet enclosure compete all as specified and directed

2

-

-

... More
S&F in replacement offload changeover switch 4 pole 250 Amps in sheet enclosure compete all as specified and directed

2

-

-

... More
S&F in replacement offload changeover switch 4 pole 320 Amps sheet enclosure compete all as specified and directed

1

-

-

... More
S&F in replacement offload changeover switch 4 pole 400 Amps sheet enclosure compete all as specified and directed

1

-

-

... More
S&F in replacement 3 pole power contactor ML-3, 28-42 Amps 415 volts, 50 HZ suitable for fixing in existing panel complete all as specified and directed

7

-

-

... More
S&F in replacement 3 pole power contactor ML-02, 20-32 Amps 415 volts, 50 HZ suitable for fixing in existing panel complete all as specified and directed

6

-

-

... More
S&F in replacement 3 pole power contactor ML-1.5, 25 Amps suitable for fixing in existing panel complete all as specified and directed

5

-

-

... More
S&F in replacement of fully automatic star - delta straters in sheet enclosure type ML-1.5 FASD complete all as specified and directed

3

-

-

... More
S&F in replacement of fully automatic star - delta straters in sheet enclosure type ML-3 FASD complete all as specified and directed

4

-

-

... More
Supply and fixing in replacement of fully automatic star delta starter type ML-4 complete all as specified and directed

2

-

-

... More
M&L in replacement of single phase preventor type VSP-II complete all as specified and directed

8

-

-

... More
S & F in replacement of Amp Meter 0 to 100 Amp of size 96 mm x 96 mm Analog Type complete all as specified and directed

6

-

-

... More
S & F in replacement of Volt Meter 0 to 500 Volts of size 96 x 96 mm Analog Type complete all as specified and directed

6

-

-

... More
S & F in replacement of Voltmeter selector switch 3 pole 415 Volts, Complete all as specified and directed

8

-

-

... More
S & F in replacement of Amp Meter 0 to 100 Amp of size 96 mm x 96 mm Digital Type complete all as specified and directed

8

-

-

... More
S & F in replacement of Volt Meter 0 to 500 Volts of size 96 x 96 mm Digital Type complete all as specified and directed

8

-

-

... More
S & F in replacement of single phase indicator lamp LED type assembly as per site requirement complete.

20

-

-

... More
M&L PVC insulated multistranded copper conductor wire, 1100 Volts in replacement, single core of size 1.5 Sq mm complete all as specified and directed

150

-

-

... More
M&L PVC insulated multistranded copper conductor wire, 1100 Volts in replacement, single core of size 2.5 Sq mm complete all as specified and directed

200

-

-

... More
S&F in replacement of thermal over load relay type ML-1.5 relay range 10-16 Amps complete all as specified and directed

10

-

-

... More
S&F in replacement of thermal over load relay type ML-2 relay range 20-32 Amps complete all as specified and directed

8

-

-

... More
Material and labour for painting to existing surcface of NRV,sluice valves/Strainers valves of capacity 80 mm to 150 mm by using spray gun with one coat of red oxide and two coat of synthetic enamel paints as per colour code as mentioned below complete all as specified and directed. (Note: color shades are as under:- NRV colour - Black, Sluice Valve colour - Black)

40

-

-

... More
Disconnecting, taking out and removing old existing unserviceable underground, LT XLPE/PVC insulated Aluminium conductor cable of any description and in any position complete including taking down existing protection pipe etc, for the size upto 50 Sqmm of any core from ducts / trenches / poles /pipes etc complete all as specified and directed. ( Excavation earth work, sand cushioning, brick protection shall be measured and paid separately)

1000

-

-

... More
Supply & laying XLPE insulated armoured PVC sheathed heavy duty underground cable with aluminium multi stranded conductor with armoured 1100 volt grade of size 10 Sqmm 4 core laid in trenches /duct passing through pipe/ duct fixed in pole and connecting and testing complete all as specified and directed.

200

-

-

... More
All as per item No 68 but 16 Sqmm 4 core

250

-

-

... More
All as per item No 68 but 35 Sqmm 3.5 core

200

-

-

... More
All as per item No 68 but 50 Sqmm 3.5 core

200

-

-

... More
All as per item No 68 but 95 Sqmm 3.5 core

150

-

-

... More
M&L cable jointing kit for 1.1 KV grade cable for straight through heat shrinkble type joint complete with jointing material suitable 3.5 core XLPE aluminum conductor cable size 35 sqmm to 120 Sqmm complete all as specified and as directed

8

-

-

... More
S&F in replacement of electromagnetic Flow meter of size 80mm with inline monitoring, IP 68 flow sensor protection, IP 65 display enclosure, accuracy +/- 0.5% of MV, IP 65 display enclosure complete all as specified and directed.

4

-

-

... More
S & F in replacement of street light energy saving envoirmental friendly long life LED street light/Bldg security light made of pressure die cast aluminium housing with with high power LED 60 Watt as light source confirming to IP 66 complete all as specified and directed.

15

-

-

... More
Supply,Installation testing and commissioning in replacement of Factory made LT panel board outdoor type, dust & Vermin proof fabricated out of 3.15 mm thick CRCA sheet fixed with Angle iron frame of size 40x40x5mm duly powder coated complete using lugs,and glands of cable connection and having epoxy coated aluminium bus bar 04 wire system of 300 Amp capacity mounted on epoxy insulators, prewired with suitable size of PVC insulated multi strand copper conductor cable having independent enclosure for incoming and outgoing electrical connection and cable gland at bottom for incoming and outgoing and locking arrangement on front side including providing danger notice plate marked skull & boons by higlighting paint and dismantling & taking out old U/S existing LT panel of any description deposited to MES Store Yard including following fittings and fixtures as mentioned below:- INCOMING:- (a) MCCB 200 Amp, Four pole, 415 Volts, 50 HZ 36 KA -01 No. (b) LED indicating lamps for main supply indicating R, Y, B - 01 Set. (c) Voltmeter 0-500 volts digital type with selector switch -01 No. (d) Current transformer having ratio 300/5, 15 VA - 01 Set. (e) Ammeter 0 to 300 amps digital type with selector switch - 01 No.

1

-

-

... More
OUTGOING :- (a) MCCB 63 Amp, Four pole, 415 Volts, 50 HZ 16 KA - 02 No (b ) MCCB 32 Amp, Four pole, 415 Volts, 50 HZ 16 KA -12 Nos. (c) Star delta Motor starter fully automatic type FASD MN-2 in sheet steel enclosure Relay range 9-15 Amp incudling Contactor, Relay and timer etc.suitable for induction motor with single phase protection relay, Auto phase sequence corrector, Low and high voltage correction and time delay 4 to 7 second complete - 04 Nos. (d) Direct on line Motor starter in sheet steel enclosure Relay range 9-15 Amp incudling Contactor, Relay and timer etc.suitable for induction motor with single phase protection relay, Auto phase sequence corrector, Low and high voltage correction and time delay 4 to 7 second complete - 06 Nos.. (e) Digital Ampere meter 0-50 Amp with selector switch 3 Phase suitable CT ratio 50/5 - 14 No.. (f) Timer switch series FM /1 quardz, type -QT (Daily) supply -240 Volt AC 50/60 Hz - 12 No

-

-

-

... More
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level all as specified and as directed.

400

-

-

... More
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed.

300

-

-

... More
Removing excavated material (soil) from site to a distance not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.

100

-

-

... More
Material and labour for Brick protection with sub class ‘B’ bricks old size, laid dry, flat over cable, perpendicular across the cable in trenches complete all as specified and as directed.

7.2

-

-

... More
Material and labour for Sand cushioning with fine dry sand in trenches, for cable protection complete all as specified in clauses 19.75 of MES schedule part-I and directed.

66

-

-

... More
Material and labour 40 mm bore GI pipe, light grade, for protection of cable, laid in trenches / under floors / Paths /along poles/ equipments etc complete all as specified & directed

18

-

-

... More
Disconnecting Electric connections from LT Control pannel and starter of non clogging submerssible pump set of any size 7.5 HP to 25 HP capacity and removing the pipe line connections from discharge side and taking out pump set along with, column pipe from sewage sump with the help of chain pully block including transportation to workshop and back for repair and lowering of same pump in sewage sump after repair including replacement of rusted nuts bolts, rubber gasket complete, making all elctric connection good, all as specified and as directed .

12

-

-

... More
Disconnecting Electric connections from LT Control pannel and starter of centrifugal/sewage, pump set of any size 3 HP to 10 HP capacity dismantling, disconnecting the pump set from foundation and removing the pipe line connections from discharge side including transportation to workshop and back for repair and re - fixing after repairing rewinding and assembling the pump set including replacement of rusted nuts bolts, rubber gasket complete, making all elctric connection good, all as specified and as directed ( Copper winding wire and other spare parts required for repairing will be measured and paid under relevant item as supply only)

10

-

-

... More
Labour for opening the centrifugal/sewage, non clogging submerssible pump set, repairing, rewinding and assembling the pump set including insulating material of any size 3 HP to 10 HP capacity complete all as specified and as directed . ( Copper winding wire and other spare parts required for repairing will be measured and paid under relevant item as supply only)

6

-

-

... More
Labour for opening the, non clogging submerssible pump set, repairing, rewinding and assembling the pump set including insulating material of any size 12.5 HP to 25 HP capacity complete all as specified and as directed. (Copper winding wire and other spare parts required for repairing will be measured and paid under relevant item as supply only)

10

-

-

... More
Supply only in replacement following spare parts for non-clogging sewage submersible pump set any type of capacity upto 25 HP

-

-

-

... More
SS rotor sleeve

10

-

-

... More
SS rotor shaft ASS 410

4

-

-

... More
Water seal

10

-

-

... More
Connetion plate

5

-

-

... More
Remetaling of rotor & turning/grinding

5

-

-

... More
GM suction ring

12

-

-

... More
GM/SS Impeller

10

-

-

... More
SS stud with nut

52

-

-

... More
Impeller nut

8

-

-

... More
Impeller key

7

-

-

... More
Joint of submersible cable any size

8

-

-

... More
Mechanical seal set upper and lower

10

-

-

... More
Jointing of cable kit without float switch

5

-

-

... More
CI suction plate

4

-

-

... More
O ring set

5

-

-

... More
Insulation kit

6

-

-

... More
Ball bearing 6312ZZ

6

-

-

... More
Roller Bearing 3310

6

-

-

... More
Roller Bearing NU 305

6

-

-

... More
Temperature sensor

5

-

-

... More
Moisture sensor

4

-

-

... More
Bearing 6306 2RS1/C3

8

-

-

... More
Bearing 6308 2 R S1/C3

8

-

-

... More
Bearing 6309 2 R S1/C3

8

-

-

... More
Bearing 3212

6

-

-

... More
Supply only copper winding wire of existing gauge for non clogging submersible / submerssible pump / induction motor sets all as specified and directed

190

-

-

... More
Supply only the following items for centrifugal/sewage pumps of capacity upto 15 HP

-

-

-

... More
CI Impeller

7

-

-

... More
Pump shaft SS AISI410

4

-

-

... More
Mechanical seal for pump shaft AISI-410

6

-

-

... More
Wear ring

7

-

-

... More
Gland CI

4

-

-

... More
Ball bearing 6307ZZ

6

-

-

... More
Bearing housing NDE

6

-

-

... More
Shaft Sleeve SS

5

-

-

... More
impeller Nut

7

-

-

... More
lock nut

7

-

-

... More
Gland packing

6

-

-

... More
Set of O rings

6

-

-

... More
Liquid deflector

4

-

-

... More
SS Gland Eye Bolt with nut

6

-

-

... More
Impeller Key

6

-

-

... More
Oil seal

6

-

-

... More
Mechanical seal for support plate

5

-

-

... More
Bent plug

5

-

-

... More
Set of gasket

7

-

-

... More
Support foot

5

-

-

... More
Lantern ring

5

-

-

... More
coupling Key CS

6

-

-

... More
Mechanical Seal

6

-

-

... More
Star Coupling Set L-110

4

-

-

... More
Star Coupling Set L-190

4

-

-

... More
M&L only for taking out suction pipe from sump of any capacity, dismantling of foot valve of capacity 80 mm to 200 mm size screw / flanged type, and relowering after refixing in position the same duly cleaned / minor repair if any required such as replacement of rubber gasket/ lifting bolts & nuts including making thread for the suction pipes off sizes etc complete all as required and as directed.

20

-

-

... More
M&L for Periodical Cleaning of Oil & Grease chamber, bar screen chamber, Equalization tank, treated water tank of any size/capacity and removing of settled down Sewage sludge cum mud/De-Silting etc complete of capacity 2 MLD STP all as specified and as directed.

1

-

-

... More
M&L for Periodical Cleaning of Oil & Grease chamber, bar screen chamber, Equalization tank, treated water tank of any size/capacity and removing of settled down Sewage sludge cum mud/De-Silting etc complete of capacity 1 MLD STP all as specified and as directed.

1

-

-

... More
M&L for Periodical Cleaning of Oil & Grease chamber, bar screen chamber, Equalization tank, treated water tank of any size/capacity and removing of settled down Sewage sludge cum mud/De-Silting etc complete of capacity 650 KLD STP all as specified and as directed.

1

-

-

... More
M&L for Periodical Cleaning of Oil & Grease chamber, bar screen chamber, Equalization tank, treated water tank of any size/capacity and removing of settled down Sewage sludge cum mud/De-Silting etc complete of capacity 150 KLD STP all as specified and as directed.

1

-

-

... More
M&L for Periodical Cleaning of Oil & Grease chamber, bar screen chamber, Equalization tank, treated water tank of any size/capacity and removing of settled down Sewage sludge cum mud/De-Silting etc complete of capacity 100 KLD STP all as specified and as directed.

1

-

-

... More
Notes for Srl item No 91 to 95 :- (a) Cleaning inner surface of tank complete by scraping with steel wire brush and removing mud and sludge collected inside the tank manually at a distance not exceeding 50 mtr all as directed. (b) Washing with clean water and bleaching powder complete tank internally and removel of left out sludge if any at site at a distance not exceeding 50mtr all as directed.

-

-

-

... More
M&L for Periodical Cleaning dewaterig and pumping out of existing accumulated Sewage/sludge and removing of settled down Sewage sludge cum mud/De-Silting etc of Sewage Well of size upto 8 mtr height x 6 mtr dia complete all as specified and as directed.

7

-

-

... More
M&L for Periodical Cleaning dewaterig and pumping out of existing accumulated Sewage/sludge of Sewage Installation and removing of settled down Sewage/ sludge cum mud/De-Silting etc of Sewage well of size 8 mtr height x 9 mtr lentgh x 7 width Notes for srl item Nos 91 to 29:- Rate quoted shall include the aspects:- (i) Diesel Driven Pump Set of appropriate capacity not less than 5/7.5 HP with operator including necessary POL required at site for De-Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes . (ii) Tractor mounted storage tank of appropriate capacity not less than 1 KL with driver directly collected from the soak well and disposing the same to the location where approved by the Delhi Canttonment Board/PCB . (iii) Tractor/truck with driver for disposal of sewage sludge and POL required for the same (duly covered with necessary Tarpaulins ) and depositing the same to the location where approved by the Delhi Canttonment Board/PCB.

3

-

-

... More
(iv) Labour element and T&P required for removal of settled down sewage sludge/mud inside the sewage tank for scooping out from inside and below the septic/ staining sewage water inside the well and lifting the same and deposited on top and near by the sewage tank where directed and further to removal the same at the location where approved by the Delhi Cantonment Board/PCB (v) Appropriate qty of Phenyle required at site for Sterilization of sewage sludge being collected in the Sewage tank . (vi) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects and including necessary Phawda, Steel Bucket, Manila rope etc required at site.

-

-

-

... More
M&L for replacement of filteration media drying bed with sand and stone gravels (a) Natural graded gravels of size 20mm to 25mm - 150mm layer (b) natural graded of size 15mm to 10mm - 100 mm layer (c) natural graded gravels of size 10mm to 6mm - 100 mm layer (d) White graded coarse quartz sand 8+14 mesh - 100 mm layer (e) White graded coarse quartz sand of 16+30 mesh 600 mm layer al las specified and directed.

85

-

-

... More
Surface Excavation not exc 30cm deep, etc in soft/ loose soil getting out and levelling of bottom surface to required level all as specified and as directed.

400

-

-

... More
M&L for replacement of Unsv MBBR Media from the tank and supply of filling Fresh media of MBBR Media in the main reactor as specified of existing /suitable Make with the following specificatios:- Effective surface area of media Approx - 400 Sqm/Cum (b) Mesdia ht Approx - 15/10 mm (c)Media dia Approx- 22 mm (d) Weight per unit surface area approx -22 mm (e) Voidage - 093 gm/Cucm (g) Media fill Range - 25-55% of volume

10

-

-

... More
Supplying and fixing in replacement Stainless steel Pipe of size 50 mm fixing on wall/well etc for all as specified and directed

100

-

-

... More
Supply and installation, connecting, testing and commissioning in replacment of high pressure single head adjustable Dosing System Adjustable 10% to 100% through a simple adjustment knob with an accuracy of + 2%, Inj. pressure 10 kg/sqcm, power input 230V, 50Hz, Max otput 27 ltr/hr with mandatory accessories like lead tubing, connceting ferrules, check valves etc. Accessories must include the following :- (i) Level switch for dry run cut off to avoid motor failure. (ii) Adaptor in stainless steel construction with FHP motor for solution making. (iii) FRP Dosing tank of net capacity 100 ltrs with removable lid, level inicator and chemically resistant to all generally used dosing chemicals. (iv) Suitable agitator single phase flange mounted motor with plastic shaft and impeller.

5

-

-

... More
M&L for Repair and overhauling including Dismantling/taking down all electrical and mechanical connection of twin lobe existing blowers of capacity upto 0.80 kg/cm2 and servicing whole body, change gear oil/lubricant and V belt,overhauling of the same including refixing and testing complete all as specified and directed. Note:- Unit rate quoted shall be deemed included supply & fixing of spare parts and gear oil/lubricant and supply of following materials :- (i) Changing of rotors assembly alongwith shaft (ii) Gear oil as recoended by OEM (iii) Bearing as per sample for air blowers model (iv) Gasket kit as per sample for air blowers model (v) Oil seal as per sample for air blowers model (vi) V-belt as per sample for air blowers model (vii) Air filter as per sample for air blowers model

3

-

-

... More
All as per item No. 35 above but of capacity 0.65 kg/cm2.

2

-

-

... More
Supply and fixing for mild steel work for manhole cover, stair case steps etc made of MS angle/ flats/channels etc including cutting out top and bottom to shape as directed, drilling holes, notching for wire etc flat iron fillets including all necessary drilling, bolting or rivetting etc and similar works confirming to Fe-290, Gde E-165 and applying two coats of synthetic enamel paint over a coat of red oxide primer including preperation after demolition of existing covers,steps etc complete all as specified and as directed.

350

-

-

... More
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint

1.5

-

-

... More
Supplying and fixing in replacement pressure gauge 100 mm dia suitable for 0 to 10 kg/sqcm for online purposes complete all as specified and as directed.

10

-

-

... More
Dismantling of existing water meter strainers, dirt box, 80 mm bore to 200 mm bore , any make/model, fixed at any location and cleaning of jalli,replacement of packing seal etc. to make it functional including making good connections with gasket rubber sheet , nuts & bolts, fixed in horizental/inclined/ vertical position complete all as specified and as directed .

20

-

-

... More
Supplying, fixing, jointing & testing cast Iron Sluice Valve, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top complete with Nuts, Bolts, washers and rubber gaskets of following sizes including taking out of unserviceable sluice valve complete all as specified and as directed.

-

-

-

... More
(a) 80 mm dia

2

-

-

... More
(b) 100 mm dia

5

-

-

... More
(c) 150 mm dia

5

-

-

... More
(d) 200 mm dia

1

-

-

... More
M&L Supplying, Laying, jointing, testing and commmisioning of DI Pipe, as per ISO - 7186 - 2011, K-7 with spigot and socketed ends centrifugally cast Class LA Push on joint laid in trenches complete including taking out of old UNSV pipe line any type all as specified and directed at site for the following sizes :- Note- Excavation & earth work for new location shall be measured & paid for seperately.

-

-

-

... More
(a) 80 mm bore

50

-

-

... More
(b) 100 mm bore

120

-

-

... More
(c) 150 mm bore

150

-

-

... More
(d) 200 mm bore

170

-

-

... More
M&Lfor CI/DI special such as tees, bends of any size and radius, tapers, collers, tail pieces, caps and plugs complete all as specified and as directed for following sizes :-

-

-

-

... More
(a) upto 150mm bore.

200

-

-

... More
(b) 200mm to 300mm bore.

250

-

-

... More
Material and labour for Tyton joints (with SBR gasket, IS-5382 marked) suitable for DI pipe of following sizes complete all as specified and as directed:-

-

-

-

... More
(a) 200mm dia

14

-

-

... More
(b) 150mm dia

18

-

-

... More
(c) 100mm dia

20

-

-

... More
(d) 80 mm dia

14

-

-

... More
Supply, installation and testing of flanged ends flow Meter ISI marked woltman type, Class 'B' of following sizes and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, including cutting of pipes complete all as specified and directed of following sizes:- Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item.

-

-

-

... More
(a) 80 mm dia

2

-

-

... More
(b) 100 mm dia

4

-

-

... More
(c) 150 mm dia

4

-

-

... More
Supplying , laying , jointing, welding & testing MS Pipe, Heavy class 'C' of followiing sizes as per IS 1239-2004 Laid in trenches or laying on floors for connections to centrifugal pump sets or through HDD Pipe under road/path/hard standing, for fresh water supply pipe line, suction of pump set, to header and to connected out going water main CI/DI pipe line, for following size including taking down the u/s one and all as directed. Note:- (a) MS Flanges and flanged joints complete with jointing material shall be measured and paid separately.

-

-

-

... More
(a) 150 mm bore.

150

-

-

... More
(b) 100 mm bore.

140

-

-

... More
(c) 80 mm bore.

55

-

-

... More
(c) 200 mm bore.

18

-

-

... More
(c) 300 mm bore.

12

-

-

... More
M&L for Cutting of 80mm bore SS/MS/CI Pipe in position for reducing to required length for insertion of new branches complete all as specified and directed.

10

-

-

... More
All as per item No. 115 above but 100mm bore.

10

-

-

... More
All as per item No. 115 above but 150mm bore.

8

-

-

... More
Supply and fixing of CI butterfly valve of size 80 mm bore PN 1.6 all as specified and directed.

10

-

-

... More
All as per item No. 118 above but size 100 mm bore.

8

-

-

... More
All as per item No. 118 above but size 150 mm bore.

7

-

-

... More
Supply and laying 3 layer (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fitting in trenches/wall/celling or laying in floors complete of 25 mm size outer dia including all fittings with and including taking down old Pipe complete all as specified and as directed. Note :- Excavation & earth work shall be measured & paid for separetely.

200

-

-

... More
All as per Item No 121 above but 32 mm size outer dia.

150

-

-

... More
All as per Item No 121 above but 50 mm size outer dia.

150

-

-

... More
All as per Item No 121 above but 90 mm size outer dia.

120

-

-

... More
All as per item No.121 above but 110 mm size outer dia.

80

-

-

... More
Supply, fixing, jointing and testing of Cast iron Non Return valve of following sizes, without by pass arrangement , Swing type, confirming to IS 5312, flanged ends, pressure rating PN 1.0 complete including taking out unserviceable NRV complete all as specified and as directed. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.

-

-

-

... More
(a) 80 mm dia

2

-

-

... More
(b) 100 mm dia

4

-

-

... More
(c) 150 mm dia

3

-

-

... More
Supplying and fixing, MS flanges of 100 mm bore not less than 16 mm thick duly welded on ends of MS pipe all as specified and directed

6

-

-

... More
Supplying and fixing, MS flanges of 150 mm bore not less than 16 mm thick duly welded on ends of MS pipe all as specified and directed

8

-

-

... More
Supplying and fixing, MS flanges of 200 mm bore not less than 16 mm thick duly welded on ends of MS pipe all as specified and directed

6

-

-

... More
Supplying and fixing, MS flanges of 300 mm bore not less than 16 mm thick duly welded on ends of MS pipe all as specified and directed

2

-

-

... More
M&L for Flanged Joints with rubber or fibre board gasket including nuts, bolts and double washers of following sizes complete all as specified and directed

-

-

-

... More
(a) 100 mm bore

12

-

-

... More
(b) 150 mm bore

20

-

-

... More
(c) 200 mm bore

8

-

-

... More
Supply and fixing of PPR gate valve (Brass inserted), ISI Marked of following size, complete all as specified and as directed

-

-

-

... More
(a) 25 mm Bore

20

-

-

... More
(b) 32 mm Bore

10

-

-

... More
(c) 50 mm Bore

5

-

-

... More
M&L for rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 500 Ltr hoisting and fixing in position all as specified in SSR Part I and as directed

4

-

-

... More
Treaming of tree branches around Bar screen chamber , MBBR reactor , Tube settler , Filteration system, chlorine contact tank/ hypo Dosing tank sludge drying bed , Oil and grease trap chamber, Rawwater collecition sump and over the boundry wall of STP plants area and cleaning upto 3 Mtrs distance from Eqpts and plants removing cut materials ( tree branches) from site and stacing properly where directed. Grith of branch ( where cutting took place) not exceeding 50 MM complete all as specified.

300

-

-

... More
S&F "No Entry" board of size 200mmx650mm of thickness 3mm MS plate duly painted on bothsides alongwith necessary fixing arrangements for instalations as per sample and as directed

15

-

-

... More
Supply and fix in replacement PVC insulated sheathed copper conductor flexible cable 1100 volts grade heavy duty of size 16 Sqmm nominal cross section area single core complete all as directed and specified.

150

-

-

... More
All as per item No 136 above but size 25 Sqmm.

150

-

-

... More
Supply and fixing in replacement of submersible copper cable of size 6sqmm 3 core 1100 volts complete all as specified and Directed. Cm

200

-

-

... More
All as per item No.138 above but of size 10 sqmm .

200

-

-

... More
All as per item No.138 above but of size 16 sqmm .

150

-

-

... More
Supply and fixing in replacement of PVC insulated, sheathed unarmoured Copper conductor flexible cable of size 4 sqmm and 7 core, round flexible, 1100 volts grade complete all as specified and directed.

55

-

-

... More
Supply and fix PVC insulated multistranded aluminium conductor, 1100 volts grade, 4 sqmm cross sectional 2 core all as directed

150

-

-

... More
Supply and fix in replacement of glass tube type air rotameter including taking down existing unserviceable air rotameter of any description complet all as specified and directed

2

-

-

... More
S & F in replacement of Heat Resistance, weather proof agro shed net for covering of tanks at various STP complete with fixing arrangement around the tank complete all as specified and as directed.

300

-

-

... More
M&L for complete overhouling and repairing of multigrade sand filter with replacement of filter media as per existing and activated carbon filter media including replacement of filter media other connected assessories as required at site of STP capacity of 2 MLD and 01 MLD including testing and wire mesh size shuold as per existing ,colour in Black ,Grade of GAC 8x30 and bulk density approx 450kg /cum, Hardness( abrasion number) approx 95-99 and PH value - 7 complete all as specified and directed

3

-

-

... More
Supplying and fixing of chequerred rubber matting of size 2Mx1Mx10mm complete all as specified and directed.

10

-

-

... More
Supply & Fixing in replacement MCB 20 Amp DP complete all as specified and as directed.

20

-

-

... More
Supply and fix in replacement 3 pole power contactor ML-3, 40 Amps,415/440 volts,50 Hz suitable for fixing in existing panel complete all as specified and as directed.

8

-

-

... More
Supply and fix in replacement 3 pole power contactor ML-2, 32 Amps,415/440 volts,50 Hz suitable for fixing in existing panel complete all as specified and as directed.

6

-

-

... More
Supply & Fixing in replacement Star/Delta Timer suitable for mounting on existing contactor complete all as specified and as directed.

4

-

-

... More
Supply & Fixing in replacement 3 pole power contactor, 3TF-35 with luxury block type (NO/NC) ,32A-55A, complete all as specified and directed.

4

-

-

... More
Supply & Fixing in replacement 3 pole power contactor MNX25 type contactor,25A-45A, complete all as specified and directed.

4

-

-

... More
Supply and fixing in replacement thermal over load relay, type MN, range 20-32 Amp complete all as specified and as directed.

4

-

-

... More
Supply and fixing in replacement thermal over load relay, type MN, range 45-75 Amp complete all as specified and as directed.

4

-

-

... More
Supply and fixing in replacement automatic star-delta starter in sheet metal enclosure with voltmeter and amp meter. Each motor rating 415 V 3 phase 50 hz for 7.5 HP pump complete all as specified and directed.

3

-

-

... More
All as per item No.155 above but 20 HP pump.

4

-

-

... More
Supply & pouring Compressor Oil (as recommended by OEM of eqpts) in air blower at STPs complete all as specified and as directed.

50

-

-

... More
M&L for PCC (1:4:8) type D2,40 mm graded stone aggregate for foundation complete all as specified and as directed.

1

-

-

... More
M&L for PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame complete all as specified and as directed.

1

-

-

... More
M&L for brick work with subclass B bricks straight or curved on plan to any radius in full brick thick( 23 cm ) walls built in cement mortar (1:4) complete all as directed and specified.

1

-

-

... More
M&L Rendering 10 mm thick with cement mortar (1:6) on fair faces of brick work for finishing the surface fair and even complete all as specified and directed.

150

-

-

... More
Material and labour for painting to steel and iron surfaces by using spray Gun with one coat red oxide and one coat of synthetic enamel paint as per existing pattern after preparation of old surfaces of any description over 10 cm in width or girth Complete all as specified and as directed.

400

-

-

... More
supply and fix in replacement street light bracket 1.2 mtr long made out of 40 mm dia light grade GI tuing made to shape including two sets of flat iron clamps , nuts , bolts washers complete all as specifiedand directed. ( Clamp shall be made of 40 x6 mm flat iron and fixed with 15mm dia x 50 mm long bolts nuts . Wt of . Providing two coats of aluminium paint over one coat of red oxide primer shall be part of item at extra c no cost .)

15

-

-

... More
Testing of Sewage water as per relevant IS of STP , submission of detailed test report to the office of the Engineer-in-charge and testing in NABL approved laboratory as approved by GE Details are as under :- (a) Carrying out minimum essential testing of sewage water as per revlevant IS mandatory for chemical, odour, PH Value, TSS, BOD,COD total nitrogen, sulphate, oil and grease ammonical Nitrogen (NH3-N) and Bacteriological total collifrom organisms and other charaterstics as per relevant IS of sewage water. Note:- Rate quoted shall deemed to be included for :- (i) Cost of sterilised bottle as required (ii) To and fro transportation charges for collection of sample

10

-

-

... More
Boring holes under road pavement manually in any type of soil upto 200 mm bore complete all as specified and directed.

1

-

-

... More
S&F in replacement of LED post top luminaire 40 W made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP-65 protection all as directed

1

-

-

... More
Design, fabricate, supply, install, test and commissioning of factory made floor mounted LT cubical panel board Indoor type made out of 2.00 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front opening and locking arrangement on front side 415 Volts, 3 phase, 50 Hz having copper bus bar of capacity 630 Amps and full neutral duly colour coded and for neutral supported with DMC/SMC insulators colour coded with heat shrinkable sleeve hearing short circuit current with stand minimum 85 KA for one second complete connection from bus bar to breakers with suitable copper cable, panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels for base frame 50x50x6 mm and supports, GI nut, bolts, washers etc. The panel board shall be powder coated and red oxided primed. The panel board shall be fabricated and suitable to accommodate and supply and fixing of the following complete all as specified and directed : Incoming :- (a) MCCB 400 Amp, 4 pole, 415 Volts, 50 HZ 36 KA -01 Nos. (b) Changeover Switches 4 pole 415 volts 400 Amps - 01 No Outgoing :- (a) MCCB 100 Amp, Three pole, 415 Volts, 50 HZ 25 KA -03 Nos.

1

-

-

... More
(b) MCCB 160 Amp, Three pole, 415 Volts, 50 HZ 25 KA -01 Nos. (c) MCCB 63 Amp, 4 pole, 415 Volts, 50 HZ 16 KA -01 Nos. (d) Soft starter suitable for 40 HP Centrifugal Pump Set 75A 208 to 690V including cooling arrangement for soft starter complete - 03 Nos. (e) Soft starter Suitable for 75 HP Centrifugal Pump 140A 208 to 690V including cooling arrangement for soft starter complete - 01 No. (d) Digital Voltmeter 96x96 Sqmm 0-500 Volts with selector switch - 05 Nos (e) Digital Ampere meter 0-200 Amp 3 Phase, 96x96 Sqmm with CT ratio 200/5 - 05 Nos (f) Indicator lamp LED type of (R,Y,B) set of 12 No

-

-

-

... More
S&F in repair of LED driver suitable for LED street light fitting 90 watts as per existing make and model complete all as specified and directed

25

-

-

... More
(xi) All existing earthing of the lifts shall be maintained and made fully functional by the contractor to the entire satisfaction of the Engr-in-Charge.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.