Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date31 Dec 2024
Closing Soon21 Jan 2025
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by Engineer- in- Charge. Note : Measurement shall be taken after punning down.

364.86

-

-

... More
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engineer- in- Charge.

40.19

-

-

... More
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends complete all specified and directed by Engg-in-Charge.

48

-

-

... More
S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah of the following bore sizes :-

-

-

-

... More
80 mm bore .

12

-

-

... More
50 mm bore .

12

-

-

... More
40 mm bore .

24

-

-

... More
Supply, laying, jointing, testing and commissioning in replacment of LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches complete all as specified and directed. Cables of the following sizes:- Note - Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.

-

-

-

... More
120 Sqmm 3.5 core

200

-

-

... More
95 Sqmm 3.5 core

200

-

-

... More
50 Sqmm 3.5 core

580

-

-

... More
125 Sqmm 3.5 core

580

-

-

... More
16 Sqmm 4 core

1500

-

-

... More
Supply & installing in replacement steel tubular swaged poles type 410 SP-31 (9 mtr long) of apprx wt.147 kg conforming to IS 2713 (Part-II) including excavation, earth work, PCC foundation, base plate, PCC coping, GI pipe for cable protection, three layers of red colour Reflector etc. and GI bracket for fitting mounting of street light fittings , complete all as per manufacturer's instructions complete all as specified and directed by Engg-in-charge. Note:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings. The steel pole shall be painted by bituminious paint total lenth inside and up to planting depth outside.

10

-

-

... More
Supply & installing in replacement steel tubular swan neck poles type 410 SP-31 (9 mtr long) of apprx wt.147 kg conforming to IS 2713 (Part-II) including excavation, earth work, PCC foundation, base plate,PCC coping,GI pipe for cable protection,three layers of red colour Reflector etc. and GI bracket for fitting mounting of street light fittings , complete all as per manufacturer's instructions complete all as specified and directed by Engg-in-charge. Note:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings . The steel pole shall be painted by bituminious paint total lenth inside and up to planting depth outside

5

-

-

... More
S&F in replacement LED street light Fitting 70 watt LED, IP-66 protection, single piece pressure die cast aluminium housing, high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 4.5 KV, prewired conductor to fitting with 3 core 1.5 sqmm pvc insulated cable along with GI pipe bracket & MS clamps etc complete all as specified and directed by the Engg-in-Charge.

35

-

-

... More
S&F in replacement LED Flood light fittings of capacity 200 Watt suitable for mounting on street light poles, IP-65 protection, single piece pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 5 KV, with bolts, nuts & washers complete all as specified and directed by Engg-in-Charge.

5

-

-

... More
S&F in replacement KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amps and 15 Amps fuse grip with base including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed by the Engg-in-Charge.

30

-

-

... More
Supply, drawing, connecting & testing in replacement of 3 core, 1.5 Sqmm PVC insulated and PVC rounded sheathed, copper conductor (flexible) industrial cable 1100 Volts grade conforming to IS-694 in steel tubular pole from KIOSK box to light fittings including providing suitable copper lugs complete all as specified and directed by the Engg-in-Charge.

270

-

-

... More
S&F in replacement bracket for street light fitting complete with 2.2 mtr long 50mm dia GI pipe medium grade and including necessary mild steel clamp, nuts,bolts and washers and painting on steel surfaces with two coats of aluminium paint complete all as specified and directed by the Engg-in-Charge.

30

-

-

... More
S&F in replacement MS clamp (suitable for holding street light bracket on steel/PCC pole) made out of 40 mm wide 6 mm thick flat iron with M.S nuts bolts 50 mm long 10 mm dia -3 Nos with flat washer (3mm thick) -02 No for each including painting with two coat of aluminium paint over one coat of red oxide to the M.S clamps complete all as specified and directed by the Engg-in-Charge.

30

-

-

... More
M&L for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminium paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed by the Engg-in-Charge.

14

-

-

... More
Supply, installing, testing and commissioning in replacement of factory made and tested (including CPRI type tested certified panel) LT Panel board ,cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The panel shall be dust and vermin proof. IP-65 class protection and shell be made of 3.15 mm CRCA MS sheet, and 50x50x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following :- (a) Incoming :- (i) MCCB 4 pole , 315 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No (iii) Ammeter 0-250 Amp digital type with 4 way rotary selector switch-01No (iv) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three (v) Indicating lamp- 01 set of three (vi) Aluminium bus bar of rating 500- set of four

1

-

-

... More
(b) Outgoing :- (i) MCCB 4 pole , 63 Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release - 04 Nos. (ii) MCCB 4 Pole, 160 Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release - 02 Nos. (c) Platform of Panel Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu.

-

-

-

... More
All as in item No 18.00 here-in-before but comprising of the following:- (a) Incoming :- (i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No (iii) Ammeter 0-250 Amp digital type with 4 way rotary selector switch-01No (iv) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three (v) Indicating lamp- 01 set of three (vi) Aluminium bus bar of rating 500- set of four (b) Outgoing :- (i) MCCB 4 pole, 100 Amps, 50 Hz, 415 Volts, 10 KA with thermal magnetic release - 01 Nos . (ii) MCCB 4 pole, 63 Amps, 50 Hz, 415 Volts, 16 KA with thermal magnetic release - 04 Nos (iii) MCCB 4 Pole,125 Amps, 50 Hz,415 Volts, 25 KA with thermal magnetic release - 01 Nos.

1

-

-

... More
Supply, installing, testing and commissioning in replacement of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement of size 450mm x 450mm x 300mm with 4 Nos 500 Amps aluminium bus bar and with 250 Amp MCCB, 4 pole, 36 KA, 415 Volt 50 Hz including all necessary excavation, earth work and platform for the Bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed sotne aggregate on top and grouting bolts etc for Bus bar chamber. The platform shall be such that it is of a height 45 cm above the nearest road level complete all as specified and directed by the Engg-in-Charge.

1

-

-

... More
Supplying and installation in replacement factory made and tested (including CPRI type tested certified panel) Timer Panel board ,cubical , out door type , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system . The panel shall be dust and vermin proof. IP-65 class protection and shell be made of 3.15 mm CRCA MS sheet, and minimum 32x32x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, closing locking arrangement including power wiring with 10 Sqmm PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade and internal wiring with 1.5 Sqmm copper conductor and comprising of the following :- (i) MCCB 3 pole , 32 Amps,50 Hz,415 Volts, 16 KA, with thermal magnetic release - 01 Nos (ii) 3 Pole power contractor, type MNX 110 having 2 NO +2 NC contacts -01 (iii) Astronomical Time switch , 240 Volt AC , 50 Hz -01 No (iv) Auto /manual selector switch -10 No (v) Aluminium bus bar 100 Amps, 4 strip 3 phase and neutral 415 volts, 50 Hz, duly insulated with heat shrinkable PVC sleeves- 01 Set Platform for the timer panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.

1

-

-

... More
M&L in replacement of earthing complete with galvanised steel earth plate electrode 60x60x6mm thick buried directly in ground (Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to and including galvanised iron earth wire 32x6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed by the Engg-in-Charge and as shown in electrical plate number 3 of MES SSR part-I (1991).

6

-

-

... More
Supply, laying, jointing, testing and commissioning of LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches complete all as specified and directed of the following sizes:- Note - Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.

-

-

-

... More
16 Sqmm 4 core

650

-

-

... More
25 Sqmm 4 core.

300

-

-

... More
50 Sqmm 3.5 core.

1350

-

-

... More
Supply and laying of GI Tubes of size 50 mm dia light grade, galvanised with all fitting laid in trenches for protection of cable in road /drain crossing etc complete all as specified and as directed by Engg-in-Charge.

40

-

-

... More
Supply and laying of GI Tubes of size 40 mm dia light grade galvanised with all fitting laid in trenches for protection of cable in road /drain crossing etc complete all as specified and as directed by Engg-in-Charge.

10

-

-

... More
Supply errection in position & fixing of complete lighiting system using raising and lowering type of high mast tower of 16 Mtr conforming to IS 875 Part III 1987 and suitable for 180 KM/hour wind speed for mounting lantern ring suitable for fixing of 120 watts LED fiood lights fittings 09 Nos(symmetrically fitted, including wiring from ground level to top of the mast, the mast should be motor operated for up and down, double drum carriage, double drum winch 6 mm 316 grade SS having rope of 7/19 with central core SS, construction trailing cable 3 core x 2.5 sqmm 1 No per mast up to heigh, foundation nut and bolt of suitable size hot dipped galvanised from special steel along with nuts and washers, anchor plates and template & circuit wiring with 10 sqmm copper wire, and power tool control, including RCC foundation as per manufacturers design and drawing complete all as specified & directed by the Engg-in-Charge. Note :- The cost of excavation, earth work and PCC for foundation of high Mast is deemed to included in the quoted rate.

2

-

-

... More
M&L for earthing complete with galvanized steel earth plate electorde of size 60x60x6mm thick burried directly in ground (earth pit not less than 2.50 m deep below ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized iron strip 25x4 mm by means of electric arc welding of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part I connected to earth test point and the equipment to be earthed all including testing and commissioning complete all as specified & directed by the Engg-in-Charge.

2

-

-

... More
S&F LED flood light 120 watt, 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant, with driver complete all as specified and directed by Engr-in-charge.

18

-

-

... More
S&F time switches astro type having longitude and latitude of Indian cities in memory, 415V three phase 20 Amp rating with 20 Amps, 415 Volts, three pole contactor fitted inside factory made 2mm thick steel enclosure duly powder coated paint complete all as specified and as directed by Engr in charge.

2

-

-

... More
S&F sheet metal enclosures Loadline distribution board TPN, 4 ways 415 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs and in and including 63A MCCB as incomming complete all as specified and as directed , including cutting chases pinning in making good to facings where required and pointing in cement mortar 1:3 ends of edges of landing,steps, cills sunsades, shelves, lintels etc and cutting for concealed conduit wiring etc and making good,cutting not exc 10 cm girth in brick wall complete all as specified and as directed by Engr in charge.

2

-

-

... More
Boring of hole horizontally under road/pavement/hard standing or any other situation by ultrasonic Trenchless technology and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends complete all as specified and as directed by Engr in charge. Note:- The quoted rates shall deemed to be included for taking permission from the concerned authorities prior to excavation and making good of any damage done during execution of work by the contractor.

38

-

-

... More
Earthing complete in replacement with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 3.5 m below normal ground level) with top edge of earth plate not less than 2.5m below normal ground level, connected to galvanized iron strip 32X6 mm by means of electric arc welding of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other side complete all as specified, including testing and commissioning complete all as specified and as directed by Engr in charge. Note : - (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe light grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI earthing and protection pipe upto 7.5 meter beyond the earth plates electrode.

8

-

-

... More
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.