Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 1,59,300Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_638912_1Bid Award Id
ViewTender No
CWE/PM/SP-26/2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L in replacement of HT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber seal suitable for transformer of any make / type / capacity in repairs all as specified and directed by Engineer-in-Charge
27
-
-
M&L in replacement of LT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber seal suitable for transformer of any make / type / capacity in repairs all as specified and directed by Engineer-in-Charge
36
-
-
M&L top gasket sheet made out of 2 mm thick cork sheet with suitable GI bolts, nuts, washers for top of transformer any capacity in repairs complete all as specified and directed
9
-
-
M&L dehydrating breather assembly aluminium / CI body of standard size filled with silica-gel for transformer of any capacity in repairs complete all as specified and directed
30
-
-
M&L temperature gauge circular dia type of standard size for transformer of any capacity in repairs complete all as specified and directed
10
-
-
M&L for replacement of worn out off load tap changer set and connecting with existing windig to match the ratio of tap position all as per existing sample suitable for transformers of capacity 63 to 1000 KVA all as specified and directed by Engineer-in-Charge.
14
-
-
Disconnecting the electric supply to the transformer, opening the top cover of 11 KV / 0.433 KV step down transformer of capacity 63 to 1000 KVA by removing the inspection cover / top cover, decanning of the transformer oil upto required level for replacement of LT/ HT bush from the shell and replacement for burnt out / unserviceable LT / HT bush, studs and gasket of buchholz to avoid leakage of oil, refilling of oil into the transformer after required repair works complete all as directed by Engineer-in-Charge. Note : (a) HT/LT bushes and gaskets will be measured and paid separately under respective items here-in after. (b) Replacement of unserviceable bolts, nuts and washers are deemed to be included in the quoted rate.
12
-
-
M&L for painting of transformer of capacity upto 500 KVA including connected LT bus duct in the transformer room with synthetic enamelled grey paint by using spray gun machine after removing all dust and rust. and writing date of paint with black synthetic enamel paint complete all as directed by Engineer-in-Charge. Make of paint: SHALIMAR/ ASIAN/ BERGER.
18
-
-
M&L for painting of transformers of capacity 630 KVA to 1000 KVA including connected LT bus duct in the transformer room with synthetic enameled grey paint by using spray gun machine after removing all dust and rust and writing date of paint with black synthetic enamel paint complete all as directed by Engineer-in-Charge. Make of paint: SHALIMAR/ ASIAN/ BERGER.
9
-
-
Supply and filling of fresh transformer oil in transformers having dielectric strength more than 45 KV in 3 mm gap including testing all as specified and directed by Engineer-in-Charge.
1600
-
-
Purification, filtration and dehydration of transformer oil of transformer installed at various indoor / outdoor sub-station by ultra high vacuum filtration machine with stream line filtration plant at a temp 60 to 70 deg. Celsius and achieving minimum dielectric withstand strength of 60 KV for 1 minute in 2.5 mm gap setting (for used oil) complete all as directed by Engineer-in-Charge.
15500
-
-
S & F in replacement digital type electronic voltmeter, size 96 mm x 96 mm, measuring range 0 to 500 V, flush pattern square type, suitable to be mounted on LT panel complete with and including suitable size of selector switch complete all as specified and as directed.
4
-
-
S & F in replacement digital electronic ammeter range upto 400 A, size 96x96mm, flush pattern squaretype, suitable to be mounted on LT panel complete with and including suitable size of selector switch and CTs complete all as specified and as directed.
12
-
-
Taking out hanging doors from LT Panels / HT VCB panel welding the doors in position by using new hinges and scrapping old surface and cleaning smoothly, removing all dust and rust and replace the door closure if required including preparation of surfaces with synthetic enamelled grey paint by using spray gun machine and writing capacity and location with black synthetic enamel paint complete all as directed by Engineer-in-Charge. Make of paint: SHALIMAR/ ASIAN/ BERGER.
12
-
-
Cutting removing the vegetation growth and surface dressing, trimming of branches of trees coming on the sub station or all around the installation yard including two pole structure areas, around power house, substation (external only) to keep always installation clean and tidy including white wash at plinth/ foundation of transformer if required complete all as specified and as directed by engineer-in-charge.
200
-
-
Disconnecting worn out HT connections any size from HT RMU, cutting worn out leads (near lugs ), re fixing new aluminium lugs, cleaning the insulator and post of cable connector with 2-26 CRC solution , insulating with HT tape , connecting the cables with post top and testing for smooth functioning complete all as specified and as directed.
6
-
-
Repair/ servicing of 400/ 630/ 800 A 11 KV mechanism / calibration of HT RMU with highly skilled mechanic specialist in electric HT breakers line, by taking out breaker mechanism, decarbonizing of all parts using CRC-2-26 spray, checking of all fixed and moving parts, tightening of all nuts & bolts, dressing, cleaning of contacts by using emery paper for fine/smooth contact, tightening of all connections, checking of alignment for easy moving of breaker, checking of ON/OFF operation with setting of buffer gap adjustment, inspecting the wiring of relays contact travel contact alignments, hard or light setting of breaker greasing of all moving mechanism complete all as specified and as directed. Note : Calibration will be carried out by auth contractor / technician and test certificate will be kept on record.
6
-
-
Supply and replacement of SF6 gas for RMU's by the trained technician at various sites complete all as specified and as directed by Engineer-in-Charge.
9
-
-
S & F in replacement of Gum boot of RMU of various capacity fixed in existing RMU complete all as specified and as directed
15
-
-
Repair/ servicing of compact sub station(CSS) including dry type transformer of various capacity with air blower and necessary insulation and VCB 400 A 11 KV mechanism/ calibration of VCB with highly skilled mechanic specialist in electric HT breakers line, by taking out breaker mechanism, decarburizing of all parts using CRC-2-26 spray, checking of all fixed and moving parts, tightening of all nuts & bolts, dressing, cleaning of contacts by using emery paper for fine/ smooth contact, tightening of all connections, checking of alignment for easy moving of breaker, checking of ON/OFF operation with setting of buffer gap adjustment, inspecting the wiring of relays contact travel contact alignments, hard or light setting of breaker greasing of all moving mechanism complete all as specified and as directed. Note : Calibration will be carried out by auth contractor / technician and test certificate will be kept on record.
4
-
-
Disconnecting worn out HT connections any size of cable from VCB, cutting worn out leads (near lugs), re fixing new aluminium lugs , cleaning the bus bar chamber with 2-26 CRC solution , insulating with HT tape , connecting the cables with bus bar and testing for smooth functioning complete all as specified and as directed.
38
-
-
Repair / servicing of 400 to 1250 A 11 KV mechanism / calibration of HT VCB with highly skilled mechanic specialist in electric HT breakers line, by taking out trolley, decarburizing of all parts using CRC-2-26 spray, checking of all fixed and moving parts, tightening of all nuts & bolts, dressing, cleaning of contacts by using emery paper for fine / smooth contact, tightening of all connections, checking of alignment for easy moving of breaker, checking of ON/ OFF operation with setting of buffer gap adjustment, inspecting the wiring of IDMT relays contact travel contact alignments, roller gap, hard or light setting of breaker greasing of all moving mechanism complete all as specified and as directed. Note ; Calibration will be carried out by auth contractor/ technician and test certificate will be kept on record.
38
-
-
S & F in replacement of following spares of VCB complete including required necessary spares :-
-
-
-
Spring charging geared motor 230V AC/DC
14
-
-
Trip Coil 24/110V DC
7
-
-
Close Latch / Trip Latch
7
-
-
Auxillary Switch 8NO+8NC or 6 NO/6NC
6
-
-
Micro Switch assembly for closing spring
8
-
-
Finger Contact (Jaw cluster) upto 1250A as per existing VCB
15
-
-
Drive Insulator of 11 KV suitable for existing VCB
10
-
-
Vacuum Interrupter - 800A to 1250 A with existing KA
12
-
-
Metal Part 250mm/135mm (for finger contact upper/ lower side)
8
-
-
Compact Mechanism for breaker as existing in PH
4
-
-
Epoxy resin Spouts Bushing for VCB
18
-
-
P.T. Holder (Male-Female)
7
-
-
Taking down IDMT relay, testing / calibration of IDMT relay (Set of two) over current and one earth fault for healthy tripping of over current and earth fault, adjust tripping time flag setting, ratio setting, instantaneous time setting etc as per installed capacity of transformer to be saved on maximum Short circuit current with considering of percentage impedance of transformers with artificial current injunction on primary side with current injunction machine and setting of relays to make as per the CT ratio complete all as specified and as directed.
30
-
-
S & F in replacement digital type single pole non directional relay for one earth fault & two over current, type CDG-31, 3D Horz 2 No S/R 3 element O/C & EF comprising over current operator with DC current connecting setting as per ratio including complete wiring complete all as specified and as directed.
12
-
-
S & F in replacement indicator lamp with and including holder & cover to show all the three phase i.e RYB to be mounted on 11 KV HT switch gear, supplying, fixing and connecting in replacement; complete all as specified and as directed.
26
-
-
S & F in replacement push button for trip and hold of 11 KV 400 A RMU / VCB complete all as specified and as directed.
20
-
-
S & F in replacement bakelite kitkat with 10 A HRC fuse type NS complete all as specified and as directed.
22
-
-
S & F in replacement primary copper wound type HT resin cast CTs, air cooled , dual current 3.0 VA, class 1 5P10 of ratio 400/1A, for protection and suitable burden for metering including making all, connection for relay meter indicator etc. and including connecting testing conforming to IS-2705-1992; complete all as specified and as directed.
12
-
-
All as per srl item No 32 here-in-before but burden of ratio 2.5 VA, class1.0 ration 300/1A
9
-
-
S & F in replacement primary copper wound type HT resin cast CTs, air cooled , dual current 15 VA burden of ratio 50/25/5 A, class 5P1O accuracy S T C 18.4 KA for 3 section protection and suitable burden for metering including making all, connection for relay meter indicator etc. and including connecting testing conforming to IS-2705-1992; complete all as specified and as directed.
12
-
-
All as per srl item No 34 here-in-before but burden of ratio 100/50/05 A complete all as specified and as directed..
9
-
-
All as per srl item No 34 here-in-before but burden of ratio 200/100/5 A complete all as specified and as directed..
12
-
-
S & F in replacement of dry type air cooled potential transformer of 11 KV single phase indoor resin cast CT of ratio 11 KV /v3/110V/v3/110V/v3 class 0.5-3, bus bar 50 VA-50 VA, insulation level 28/75 KV voltage factor 1.2 Cont and 1.9 for 30 Sec conforming to IS-3156 complete all as specified and as directed.
4
-
-
Supply and fix digital type ammeter of size 96X96 mm on HT panel as that of existing range model to suit to existing CT ratio 100/1A including taking out unserviceable one connecting, testing and commissioning all as specified and directed by Engineer-in-Charge.
9
-
-
Supply and fix digital type ammeter of size 96X96 mm on HT panel as that of existing range model to suit to existing CT ratio 150/1A including taking out unserviceable one connecting, testing and commissioning all as specified and directed by Engineer-in-Charge.
9
-
-
Supply only 11KV HT rubber hand gloves ISI marked all as specified and directed by Engineer-in-Charge.
10
-
-
Supply, laying and pasting on floor suitable for HV 11KV synthetic insulating rubber mat of size 2m x1m x 19mm class A make ISI mark all as specified and directed by Engineer-in-Charge.
27
-
-
S& F in replacement maintenance free battery 12 Volt, 40/45 AH complete all as specified and directed.
4
-
-
S& F in replacement maintenance free battery 12 Volt, 120AH complete all as specified and directed. Note for item no. 42 & 43 : Quoted rates shall be inclusive to disconnect or taking out battery from power pack unit and fixing new battery including replacement of battery terminal,if required complete.
6
-
-
S & F in replacement of power pack unit input 110 / 230 Volt AC and out put 24/110 V DC for maintenance free batteries charging for smooth tripping complete all as specified and directed.
1
-
-
S & F in replacement of old deteriorated aluminium tube terminals with new aluminium tube terminals for HT cable (heavy duty thimble) of size 95 sqmm including suitable size nuts, bolts & washers complete all as specified and directed.
15
-
-
All as per item No 45 above but 120 sqmm complete all as specified and directed.
20
-
-
All as per item No 45 above but 150 sqmm complete all as specified and directed.
20
-
-
All as per item No 45 above but 185 sqmm complete all as specified and directed.
20
-
-
All as per item No 45 above but 300 sqmm complete all as specified and directed.
20
-
-
S & F in replacement of HT danger notice plate of 25cm x 20 cm x 1.6mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of required complete all as specified and directed. (Note : Letters and Nos shall be in local language, Hindi and English) Note : For 20 to 44 shall be of existing make/ model and of reputed brand or as approved by Engineer-in Charge/GE.
13
-
-
M&L for Air break switch (GOD) Gang Operated Device horizontal / vertical type, triple pole, mechanically operated, mounted on nine FRP insulators and steel frame, with operating mechanism worked from ground level, with operating rod 25mm dia light grade GI pipe, suitable for current rating upto 200 Amps, HT 11 KV including taking out old unserviceable one and connecting up complete with locking arrangement all as specified and directed.
2
-
-
Material and labourin replacement ligtening arrestors expulsion type complete with all fittings, transmission class discharge capacity 65 kilo amps suitable for 11000 volts complete all as specified and directed by Engr In Charge.
1
-
-
S& F in replacement Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes Fe 410-W (Gde-E-250) quality-A complete all as specified and directed by Engr-in-charge
250
-
-
M&L preparation of old painted steel surfaces or wire mesh fencing around the out door transformer over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
250
-
-
Dismantling disconnecting and taking out existing unserviceable defective HT cable any size any type from trenches / duct / poles including taking out old bricks complete all as specified and directed.
1000
-
-
Supply, laying, testing and commissioning in replacement for XLPE insulated , screened PVC bedded, galvanized strip, armoured, electric power cable, heavy duty with aluminium conductor 11 KV (E) grade, cross sectional area 95 Sqmm x 3 core confirming to IS-7098 ( Part II ) ( amended upto date ) including supplying, jointing and testing complete all as specified and as directed.
300
-
-
Supply, laying, testing and commissioning in replacement for XLPE insulated , screened PVC bedded, galvanized strip, armoured, electric power cable, heavy duty with aluminium conductor 11 KV (E) grade, cross sectional area 120 Sqmm x 3 core confirming to IS-7098 ( Part II ) ( amended upto date ) including supplying, jointing and testing complete all as specified and directed.
250
-
-
Supply, laying, testing and commissioning in replacement for XLPE insulated , screened PVC bedded, galvanized strip, armoured, electric power cable, heavy duty with aluminium conductor 11 KV (E) grade, cross sectional area 150 Sqmm x 3 core confirming to IS-7098 ( Part II ) ( amended upto date ) including supplying, jointing and testing complete all as specified and directed. Note (for item no 56 to 58) : Earth work excavation, returning filling, removal and necessary cable protection items shall be measured and paid separately vide relevant items of this schedule.
250
-
-
Supply, laying, testing and commissioning in replacement for HT cable XLPE insulated screened, earthed PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) (earthed) with stranded aluminium conductor, 11000 Volts grade, of size 185 Sq mm 3 core conforming to IS 7098-part II complete all as specified and directed.
100
-
-
Supply, laying, testing and commissioning in replacement for HT cable XLPE insulated screened, earthed PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) (earthed) with stranded aluminium conductor, 11000 Volts grade, of size 300 Sq mm 3 core conforming to IS 7098-part II complete all as specified and directed.
100
-
-
Dismantling of old unserviceable cable joints kit of any type and material and labour for cable jointing kit for 11 KV (E) grade cable for indoor termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
8
-
-
Dismantling of old unserviceable cable joints kit of any type and material and labour for cable jointing kit for 11 KV (E) grade cable for indoor termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
16
-
-
Dismantling of old unserviceable cable joints kit of any type and material and labour for cable jointing kit for 11 KV (E) grade cable for indoor termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm complete all as specified and directed.
6
-
-
Dismantling of old unserviceable cable joints kit of any type and material and labour for cable jointing kit for 11 KV (E) grade cable for outdoor termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size upto 95 sqmm complete all as specified and directed.
10
-
-
Dismantling of old unserviceable cable joints kit of any type and material and labour for cable jointing kit for 11 KV (E) grade cable for outdoor termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
14
-
-
Material and labour in replacement for cable jointing kit for 11 KV (E) grade cable outdoor for straight through cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm complete all as specified and directed.
6
-
-
Material and labour in replacement for cable jointing kit for 11 KV (E) grade cable outdoor for straight through cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
6
-
-
M&L for defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. excavation in any type of soil strata, exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 Sqmm 3 core. The fault located equipment will be brought to site within 02 hours of instruction received from Engineer-in-Charge complete all as specified and as directed.
Notes for Srl. Item No.68 : (i) The contractor shall bring the fault locating equipment at site with in 02 hours of instructions received from Engineer -in- charge and he shall ensure that the fault is rectified within 24 hours of receipt of intimation from Engineer-in-charge failing which recovery of Rs. 500.00 per hour shall be recovered from the contractors dues w.e.f the time immediately after the expiry of 24 hours duration.(ii) For the purpose of payment one unit of “each job” shall comprise of detection of faults in a particular stretch of cable which are identified in that particular stretch , irrespective of number of defects / faults in that particular stretch which are detected during fault detection and the contractors unit rate quoted shall be deemed to include for the same and all such defects / faults which are detected in that particular stretch shall be considered as one unit. (iii.) Joints, jointing materials and cable required shall be measured and paid for separately.
32
-
-
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip 25x4 mm as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner.
15
-
-
Taking out old unserviceable under ground LT cable upto 300 sqmm from trenches / floor / road / pipe / along poles including taking out old bricks complete all as specified and directed by Engineer-in-charge.
700
-
-
Supply and laying in replacement XLPE Insulated, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor conforming to IS 7098/1985 ISI marked with necessary termination lugs, glands etc all as specified and as directed of size 120sqmm, 3.5 core laid in trenches/ ducts/ along poles/ through pipes complete all as specified & directed by Engineer-in- charge.
Note(for item No 71 to 73): Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule.
100
-
-
Supply and laying in replacement XLPE Insulated, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor conforming to IS 7098/1985 ISI marked with necessary termination lugs, glands etc all as specified and as directed of size 240 sqmm, 3.5 core laid in trenches / ducts / along poles/ through pipes complete all as specified & directed by Engineer-in- charge.
300
-
-
Supply and laying in replacement XLPE Insulated, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor conforming to IS 7098/1985 ISI marked with necessary termination lugs, glands etc all as specified and as directed of size 150 sqmm, 3.5 core laid in trenches / ducts / along poles / through pipes complete all as specified & directed by Engineer-in- charge.
300
-
-
Taking up or down and relaying of HT/LT UG cable of size 95 sqmm to 185 sqmm, including connection with cleaning for refixing carefully complete all as specified and directed.
100
-
-
Excavation in trenches in soft/ loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying underground electric cable or for pole etc complete all as specified and directed.
Note :- Mechanical excavation is not allowed in this station, only manual excavation allowed.
528
-
-
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil complete all as specified and directed.
347
-
-
Removing excavated surplus soil to a distance upto 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
181
-
-
Supply and laying un-reinforced precast concrete cable cover class HV type-I flat size 300 mmx180mmx40mm complete all as specified and directed.
1330
-
-
M&L for brick sub class 'B' locally available best quality laid in trenches above sand consolidated for cable protection complete all as specified and directed.
5.3
-
-
M&L for sand cushioning by using fine sand (Jamuna dry and clean sand) in two layers, first layer of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable complete all as specified and directed.
121
-
-
S&F in replacement GI pipe light grade 80mm bore for cable protection with all fittings for passing the under ground HT cable under road crossing along poles walls and floors complete all as specified and directed.
80
-
-
M&L for cutting of metallic road / hard standing / hard rock/ wall up to a size not exceeding 20 cm width and not exceeding 90 cm depth for laying of protection pipe for cable including making good the disturbed road/ hard standing by providing PCC (1:2:4) type B1, 40mm grade crushed stone aggregate and block top with black bituminous upto existing surface including suitable size of GI pipe (if necessary) complete all as specified and as specified and as directed by Engineer-in-Charge. Note:1. If damage / broken the interlocking tiles while removing the contractor shall replace the broken tiles with new one. 2. The quoted rate is included for all material can not be paid /measured separately. 3. All the removable inter locking tiles/ refixable material shall kept carefully at a safe place for refixing with quoted rate.
15
-
-
M&L for excavation by trench less boring technology for holes under road pavement, hard standing using ultra sound technique and engaging necessary machine including HDPE pipe ISI marked of dia 100 mm suitable for 0.4 Mpa working pressure complete all as specified and directed by Eng-in-charge. Note: HDPE pipe and making good the disturbed surface is deemed to be included in rate quoted by contractor).
10
-
-
M&L for cement concrete in foundations, filling and mass concrete type D2 1:4:8 with 40 mm graded stone aggregate for foundation of pole etc complete all as specified and directed.
1
-
-
M&L for providing cement concrete type B1, 1:2:4 using 20 mm stone aggregate in foundation, roof, kerb or mud stops, rounded or chamfered on edges complete all as specified and directed.
2
-
-
M&L for painting to existing surface of PCC poles (9 to 11 meter long) with 2 coat of white colour weather proof paint over the existing surface including bracket clamps junction boxes etc. including painting with black to 1.5 mtr height from top of PCC coping and marking pole numbers with one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge
247
-
-
S&F in replacement of applying paint / strip on any type of poles including 25mm overlapping and applying feviquick on joints duly different colour of size 5cm x 3 nos between every interval 5 cm complete all as specified and directed by Engr-in-charge.
747
-
-
M&L for preparation of old painted existing surface of steel tubular swaged poles or hexagonal poles / (9 to 11 meter long) with good neck brackets including junction box, GI pipe and light fittings any rating and painting with one coat of aluminium paint including cleaning the acrylic cover and painting with black to 1.5 mtr height from top of PCC coping and marking pole numbers with one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge
500
-
-
Supply and fix in repair hot moulded FRP looping /Junction box size 280 mmx200 mm for street light poles with locking arrangement and suitable connection for three phase incoming cable 3 phase out going cable and single phase connection for light fitting incl controlled MCB SP-10 Amps -01 Nos enclosed in thermo plastic in closed shock froof safe IP-65, weather, vermin proof, dust and water proof complete with two nos cables entry incl gland of standard size with suitable size mild steel clamps to fixed on pole complete all as specified. Make-Neptune / Hensel / Sintex
50
-
-
Dismantling and taking out exhaust fan 230 volts 300 to 450mm sweep any make cutting the old burnt winding, rewinding with new super enamelled copper wire of existing guage including insertion of insulating papers threading and insulating with insulating warnish, lathe work, replacement of capacitor, replacement of gun metal bushes/ bearings and painting after completion of rewinding process complete all as specified and directed.
10
-
-
Dismantling and taking out ceiling fan 230 volts 1200/1400mm sweep any make cutting the old burnt winding rewinding with new super enamelled copper wire as existing gauge including insertion of insulating papers threading and insulating with insulating varnish, lathe work, replacement of 2.25/3.15 MFD capacitor, replacement of MS split clamp with rubber reel and painting after completion of rewinding process complete all as specified and directed.
25
-
-
S&F in replacement of MCCB 400 Amps FP 415 volts 3 phase 50 HZ with adjustable thermal & adjustable magnetic setting of rupturing capacity 36 KA complete all as specified and directed.
2
-
-
S&F in replacement of MCCB 250 Amps FP 415 volts 3 phase 50 HZ with adjustable thermal & adjustable magnetic setting of rupturing capacity 36 KA complete all as specified and directed.
3
-
-
S&F in replacement of MCCB 200 Amps FP 415 volts 3 phase 50 HZ with adjustable thermal & adjustable magnetic setting of rupturing capacity 36 KA complete all as specified and directed.
2
-
-
S&F in replacement of MCCB 160 Amps FP 415 volts 3 phase 50 HZ with adjustable thermal & adjustable magnetic setting of rupturing capacity 36 KA complete all as specified and directed.
3
-
-