Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Ge/c-96/2024-25 Repair/ Maint Of Roofs From Leakage/ Seapage Alongwith Roof Treatment Including Repair/ Replacement Of Internal Wiring, Mcb Spn Db, Repair Of Electrical Appliance Such As Bldc Ceiling Fan, Normal Ceiling Fan, Exhaust Fan, Fresh Air F
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_689797_1Tender No
GE/C-96/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
M&L for 15mm average thick (average) screed bed in cement mortar 1:4 using WPC on roof surfaces & finished even and smooth with using extra cement in any position upto G+5 storey bldg complete all as specified.
1800
-
-
... More
M&L Applying a coat of bituminius primer confirming to IS 3384 @ 0.5 ltr/sqm on prepared surface of plaster. after drying of primer, applying a coat of hot blown bitumin 85/25 grade @ 1.2 kg/sqm and applying APP based Polymeric membrane minimum weighting 3 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric(wt.not less than 150 grm/ sqm) and sealing joints by torch application complete all as specified. Over the APP memberane applying semi hot blown bitumin 85/25 @ 0.5 Kg/Sqm and dusting over the bitumin coat.all as specified.
1750
-
-
... More
M&L for applying two coat of silver Shield BITUMINIOUS paint on app membrane complete all as specified and directed by Engr-in-Charge.
1750
-
-
... More
M & L for applying Smartcare Dampproof, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on top of roof surface in multiple coats @2 litre/sqm. Primary coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and other coats needs to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. When the 2nd coat is wet, the Smartcare EPDM tape (at corners and edges)shall be inserted between second and third coat to secure corners & edges, let the material ooze out from the tapes corner. Same treatment of Smartcare Dampproof shall be continued to the parapet walls to better envelope the whole area. The coating shall be terminated carefully to the other side of the parapet wall.upto G+5 storey bldg Notes for item Nos 5 to 7: (a) The work shall be executed through authorised applicator of manufacturer only.
(b) Authrised Applicator shall be approved by GE before starting of work.
(c) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material.
Engineer-in-Charge shall deface the original purchase vouchers.
(d) MOU with authorized applicator will be submitted by contractor within 7 days after opening of Financial Bid.
(d) A guarantee amount of 5% of contract of work done for item Nos 5 to 7 of BOQ will be retained for 5 years of the completion of work.
400
-
-
... More
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and
hoisting if required reconnecting and re-fixing in position. PVC water tanks of exc 250 litres and n.exc 500 litres capacity of any condition or type incl complete all as specified and directed.
40
-
-
... More
Demolition of brick work built in cement mortar in any description and position, upto G+5 storey bldg complete all as specified..
10
-
-
... More
Brick work with old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 (1 cement : 6 coarse sand), upto G+5 storey bldg complete all as specified.
8
-
-
... More
All as per serial item No 10 but except bricks, all as specified. (Servicable bricks retrieved from Serial Item No 08 shall be used).upto G+5 storey bldg complete all as specified.
2
-
-
... More
Taking down cement plaster in any thickness from brick or stone etc including raking out joints, hacking for key, scrubbing down with water etc upto G+5 storey bldg complete all as specified.
500
-
-
... More
Rendering 15mm thick in CM 1:4 with WPC on fair faces of brickworks including finished even and fair.
Note:- cost of WPC is paid separately
604
-
-
... More
M&L for Newly plastered or unplastered wall surface and applying two coats of weather coat/apex paint on walls complete all as specified and directed.
604
-
-
... More
M & L Providing, cement concrete in kerbs, coping to top of wall, rounded or chamfered on edges type C 0 1:3:6 (12.5mm graded stone aggegate) including demolition complete all as specified and as directed
2
-
-
... More
Supply only liquid water proofing compound complete all as specified and directed.
80
-
-
... More
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
340
-
-
... More
Taking down old MCCB , TPN DBs , SPN DBs, & main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed.
47
-
-
... More
Taking down old submain wiring of any size, including coduit and make from the site complete all as specified.
750
-
-
... More
Taking down old unsv light fitting of any size and make from the site and making good surface complete all as specified.
1625
-
-
... More
Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed / surface PVC conduits as suitable of site (Medium grade) of size not less than 20 mm dia incl proper colour coding Phase -red/yellow/blue, neutral- black and earth green including making good disturbed surfaces with existing colour coding matching all as directed with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, 3 mm thick hylem sheet cover for terminal boxes painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with and including all accessories for PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
-
-
-
... More
All as per item No 21 above but one light/fan point controlled by one switch.
130
-
-
... More
All as per item No 21 above but One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board.
70
-
-
... More
All as per item No 21 above but One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
70
-
-
... More
All as per item No 21 above but One bell point controlled by one bell push.
10
-
-
... More
All as per item No 21 above but One light point controlled by two Nos two way switches .
10
-
-
... More
All as per item No 21 above but point wiring with two single core 4.0 sqmm size cables and one 4.0 sqmm green colour cable as earth continuity conductor for one 6 pin 15 Amps socket out let on independent board.
50
-
-
... More
M&L switch piano flush type 5 Amp SP one way ISI marked complete all as specified.
270
-
-
... More
M&L switch piano flush type 5 Amp SP two way.
10
-
-
... More
M&L switch piano flush type 15 Amp SP one way ISI marked complete all as specified.
60
-
-
... More
M&L bell push,flush type,5 amp ISI marked complete all as specified.
5
-
-
... More
M&L socket outlet 5 pin 5 Amp flush type ISI marked complete all as specified.
100
-
-
... More
M&L socket outlet 2 in 1,3 pin 5/15 Amps ISI marked complete all as specified .
60
-
-
... More
M&L ceiling rose 3 phase PVC polycorbonate,isolated body. complete all as specified.
20
-
-
... More
S & F electronic fan regulator 5 step ISI marked connecting complete all as specified.
75
-
-
... More
M&L bell electric (ding dong) 230 volt, SP all as specified and directed.
10
-
-
... More
M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 4 Sqmm in and including new PVC conduit medium grade not less than 20 mm dia, proper colour coding Phase -red/yellow/blue, neutral- black and earth green including making good disturbed surfaces with existing colour coding matching for submain wiring and connection complete FRLS 1100 volts unsheathed stranded copper conuctor cable of 2.5 Sqmm size stranded conductor as earthwire.
400
-
-
... More
M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 6 Sqmm in and including new PVC conduit medium grade not less than 20 mm dia, proper colour coding Phase -red/yellow/blue, neutral- black and earth green including making good disturbed surfaces with existing colour coding matching for submain wiring and connection complete FRLS 1100 volts unsheathed stranded copper conuctor cable of 4 Sqmm size stranded conductor as earthwire.
350
-
-
... More
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI80, Power Factor 0.95, THD 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete. Make: Eveready, Philips, Wipro
1050
-
-
... More
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 900 lm system lumen output with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI 80, power factor 0.95, THD 10%, color temperature 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete. Make: Eveready, Philips, Wipro
150
-
-
... More
Supply and fix 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is 90 lm/W with a life class of 25,000 burning hours at L70 criteria, Power Factor 0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency 85%, THD10%, CRI80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete. Make: Eveready, Philips, Wipro
280
-
-
... More
Supply and fix 45 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 25,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor.0.9, voltage variation range 120-270V, THD20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete. Make: Eveready, Philips, Wipro
45
-
-
... More
S & F in replacement of decorative type wall mounted luminaire (comet) with under take poly carbonate material suitable for 1 x 14 watts LED bulb B-22 base complete all as specified and as directed. Make: Eveready, Philips, Wipro
100
-
-
... More
S&F angle Lamp holder with metallic ring, PVC/Polycorbonate type with back plate complete.
100
-
-
... More
S & F LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base .
100
-
-
... More
Refixing of Ceiling fan / exhaust fan/ fresh air including taking down after necessary repairs/ replacement of unserviceable/ wornout part and testing the same as per entire satisfaction of Engr-in- Charge complete all as specified and directed. Note- Spare Parts shall be measured and paid separately under relevant item of supply only.
360
-
-
... More
M&L for opening up the winding of ceiling fan 1200 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Teating of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge.
360
-
-
... More
S&F in replacement capacitor of 2.5 MFD.
360
-
-
... More
S&F in replacement gun metal bush of any size and make sutiable for ceiling fans 1200 mm compete all as specified and directed.
360
-
-
... More
S&F in replacement ball bearing No. 6202./6203
360
-
-
... More
S&F in replacement worn out shaft, beyond economical repair of existing ceiling fan any make, type or size as per original one ceiling/exhaust fan complete all as directed.
360
-
-
... More
S&F Ceiling fan blade suitable for 1200mm sweep of any make with suitable size as per site requirement complete all as specified and directed.
10
-
-
... More
M & L for painting of ceiling fans , in situ with synthetic enamel paint by spraying including filling cavities with filler, one or more coat to achieve even and smooth surface after cleaning all dust etc.and endorsement of fan no.with black synthetic enamel paint complete all as directed.
360
-
-
... More
S&F in replacement exhaust fan motor capacity 1/4 HP 230 volts suitable for 300 mm size exhaust fan complete all as directed.
50
-
-
... More
Taking down carefully geysers 25/35/50 ltrs capacity opening for inspection reassembling and re-fixing in position after carrying out repairs rates included for replacement of pressed rubber gasket nuts, bolts etc complete all as directed. Note- Spare Parts such as tank, apparatus plate, outer body shall be measured and paid separately under relevant item of supply only.
15
-
-
... More
S&F in replacement only base plate assembly (confirming to ISI ) complete for 25/35 Ltrs capacity copper tank geyser including inlet, outlet and thermostat pipe with drain plug and screws for fixing the element inclusive of clamps for holding the elements with nut, bolts & air release valve suitable for any type/make of geysers installed at site as directed.
20
-
-
... More
S&F in replacement of thermostat for 25/35/50 ltrs capacity of geysers complete all as directed.
150
-
-
... More
S&F in replacement heating element of 2.0 KW triangular type with nut bolt washer complete all as directed.
350
-
-
... More
M&L for safety pressure valve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge.
50
-
-
... More
M & L chromium plated copper connection pipe 60 Cm long with two brass adopters and connecting up complete all as directed.
200
-
-
... More
Supply only inner still tank for geysers of capacity 25/35 ltr as per existing of approved make complete all as directed.
10
-
-
... More
S&F MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete.
3
-
-
... More
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete.
15
-
-
... More
M&L MCB SPN 40 Amp "C " curve all as directed.
40
-
-
... More
M&L MCB SP 6 to 32 Amp "C" curve all as directed.
120
-
-
... More
Supply & fix in repair factory made epoxy powder coated Distribution Board VTPN-4 ways (IP-43 protection), mechanical impact strength IK - 08, with cement spill protector double door fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified and conforming to HSN code : 8537. Make : Indo Asian Cat Part No : 811870 or equivalent Make of Havells/Legrand/L&T Note :- MCCB & MCB will be measured & paid separately.
5
-
-
... More
S & F MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .
12
-
-
... More
S & F MCCB 125 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .
8
-
-
... More
S & F MCCB 100 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .
4
-
-
... More
S& F in replacement recessed mounting LED FLAT panel 2"x2" made of crca sheet steel duly power coated with high efficient LED and glaire free full opal diffuser , IP 20 Suitable for 36 watt,230 volts ,50 Hz AC Supply, Neutral White,with electronic driver and incluiding all fixing accessories complete all as specified and directed.
55
-
-
... More
S & F against BER fresh air fan PVC body air delivery 800 CMH , 5 number of blades, AC single phase 230/240 V of size 250 mm sweep with louvre fixed complete with suitable size ply by cutting into suitable size as required complete all as specified and directed by Engr-in-Charge.
15
-
-
... More
S&F against BER exhaust fans AC single phase 230/240 V of size 300 mm sweep, Air flow rate 900cum/min, Bird screen for protection against birds, double ball bearing, heavy duty, metal body with louvers for fixing of exhaust fan complete
12
-
-
... More
S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 10 Amp 220 volts, 50 Hz, 10KA breaking capacity for geyser , including fixing completly in wall with sutable sand and cement, complete.
25
-
-
... More
M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to earth lead GI 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dai and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) including testing ion completion all as directed
14
-
-
... More
Supply & Fix against BER of wall fan 400 mm 3 blade in replacement sweep metal type including provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor, length as per requirement at site complete all as specified and directed by Engineer-in-Charge.
14
-
-
... More
Supply, installation, testing & commissioning, fabricated wall mounted LT panel board indoor type of size 1050x150x1200mm (approx) made out of 2 mm thick CRCA sheet suitable for 415 volts, 3 phase, 4 wire duly painted with two coats of synthetic enamelled paint including fixing of of 200 Amps rated copper bus bar for 3 phase and neutral duly fixed on suitable size of insulator, two Nos earth terminal test point, 3 Nos indicator lamp comprising of the following installed complete (a) INCOMING
(ii) MCCB 4 pole 125 Amps, 16 kA breaking capacity-01 No. (iii) digital Voltmeter with inbuilt selector switch, Range 0 to 500 Volts -01 Nos
(iv) digital Ammeter 0 to 150 Amp with inbuilt selector switch, alongwith sutiable size of CTs set (b) OUTGOING
(i) MCB SPN 40 Amps 10 kA breaking capacity duly fixed on DIN rail channel-08 Nos ( Outgoing for each qtr) (ii) MCB SPN 10 Amps 10 kA breaking capacity duly fixed on DIN rail channel-02 Nos ( Outgoing for staircase and security light) (iii) Provision & install for new electric meter install inside the LT panrl - 08 Nos Note- (i) Marking of Building No & quarter Nos on outgoing feeders of LT panel. (ii) Contractor before placing order, LT panel drawing shall be got approved by the GE.
3
-
-
... More
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc 4 mm dia galvanised or steel wire complete all as specified.
66
-
-
... More
Clening of LT panel of board indoor type of size 1050x150x1200mm (approx) or any other sizes made out of 2 mm thick CRCA sheet suitable for 415 volts, 3 phase, 4 wire, duly painted with two coats of synthetic enamelled paint and checking of all MCCB/MCB and connected wiring all as specified and as directed by Engineer-in-Charge Note : If require MCCB/MCB to be measured & paid separately.
7
-
-
... More
M&L for breaking the old existing wall and making provn of a round hole for fixing of 300 mm sweep exhaust fan including making good to the disturbed wall/ portion and matching with existing colour.all as specified and directed.
18
-
-
... More
Supply & Fix all accessories of PCB BLDC ceiling fan any type, any make & any capacity including taking down carefully ceiling fan & refixing the same as per requirement at site complete all as specified & directed by Engineer-in- Charge
271
-
-
... More
S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity for AC, including fixing completly in wall with sutable sand and cement, complete.
25
-
-
... More
Schedule of Credit
-
-
-29925
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%