Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 1,00,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Ge/c-74/2024-25 Periodical Services And Misc Left Over B/r Works Of Md Accn Including Petty Repair And Misc E/m Works Including Daily Maints Complaints At Dk-ii Offr Enclave, Rrrc Trg Area Under Ge (central) Delhi Cantt-10
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679883_2Tender No
GE/C-74/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
M&L for 5mm thick rendering in cement mortar 1:3 finished fair and even surface without using extra cement on ceiling, chajja in multy storey building etc complete all as specified.
200
-
-
... More
M&L preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed.
200
-
-
... More
Material and labour for preparation of new plastered surfaces as of walls and applying Two coats of weather proofing exterior acrylic emulsion paint over one coat of primer from the same manufacturer white lime wash complete all as specified and directed.
1500
-
-
... More
M&L for new plaster surface two coat of oil bound destemper over 3mm thick of birla white putty including preparation of newly plastered surface etc all as specified.
300
-
-
... More
M&L for preparation of old decoreated/undecoreated external wall / Ceiling applying two coats of cement base paint by spray gun/ spray machine up to 8 storey bldg complete all as specified and all as directed by Engr- in-charge.
Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes.
2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+2 bldg including scaffolding
4000
-
-
... More
M&L for preparation of old decoreated external wall / internal wall/Ceiling surface of existing treatment by scrapping with TruCare Wall Sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7”/9” to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible up to 8 storey bldg complete all as specified and all as directed by Engr- in-charge.
Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes.
2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+2 bldg including scaffolding
20000
-
-
... More
M& L for preparing the entire surface with applying 2-3 mm thick birla/ JK wall care putty on walls and ceiling surface finished even and smooth complete all as specified and directed.
20000
-
-
... More
M& L for preparing the entire surface with applying priming surface with alklai resistance priming paint on walls and ceiling surface finished even and smooth complete all as specified and directed.
20000
-
-
... More
M&L for external wall / Ceiling applying two coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine up to 3 storey bldg complete all as specified and all as directed by Engr- in-charge.
Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes.
2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+3 bldg including scaffolding
20000
-
-
... More
M&L for Preparation of old painted surfaces of wood surfaces of any description over 10 Cm width or girth by applying sand paper etc.for proper preparation and applying two coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified and directed. Note rate quoted up to G+8 bldg including scaffolding
1000
-
-
... More
M&L for Preparation of old painted surfaces of steel of any description over 10 Cm width or girth by applying sand paper etc.for proper preparation and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks all as specified and directed complete all as specified and directed. Note rate quoted up to G+8 bldg including scaffolding
200
-
-
... More
M & L preparation of surface for Writing building Numbers on building by applying black synthetic enamel paint on white base all as specified and directed by Engr-in-charge.
250
-
-
... More
M & L for removal of plant growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water. The size of block shall be of 2 Qtrs on each floor and vary in number of floors. All roots of plants shall be removed completely and making good the disturbed surface and painted with cement base or acrylic paint all as specified and directed by Engr-in-charge.
50
-
-
... More
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete.
623.5
-
-
... More
M & L for Non skid 600x600x8 to 8-10mm thick coloured ceramic tiles as in floor over hacking surface of existing floor on 15mm thick screed bed in CM 1:6 including pointing in coloured cement to match the shade of tiles including cutting of existing door shutter at required height. complete all as specified directed by Engr-in-Charge.
80
-
-
... More
All as per item No 18 above but 10mm thick on rendering surface in CM 1:4 on vertical surfaces of wall as in skirting including taking down of existing skirting on walls complete all as specified directed by Engr-in-Charge.
43.5
-
-
... More
M& L for Non skid coloured ceramic tiles (300x300x)7 to 8mm thick in floors, etc, set and jointed in neat cement slurry and pointed in coloured cement to match including 15mm thick screed bed for laying floor in CM 1:6 complete all as specified and directed by Engineer in Charge.
150
-
-
... More
M&L for coloured ceramic tiles (450x350mm)x7mm thick on vertical surfaces on skirting dados and risers to steps etc including rendering 10mm thick cement mortar in CM 1:4 ,complete all as specified and directed by Engr-in-Charge.
150
-
-
... More
M&L for coloured Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tilesnot exceeding 0.36 sqm, in floors etc. set and jointed in neat c ement slurry and pointed in white or coloured cement to match rendering 15mm thick cement mortar in CM 1:4 ,complete all as specified and directed by Engr-in-Charge.
200
-
-
... More
Checking electrical points for continuous electric supply system and replacement of unserviceable spares for all electrical fixtures, ceiling/exhaust fans of any size and capacity and carrying out minor repairs, fixing screws, tightening of loose wires, any type renewal of small pieces of electric wire upto 1.00 mtr length and maintenance work complete on all working days including holidays all as directed by Engr-in-charge, at DK-2 and adjoining area.
5600
-
-
... More
Attending to complaint of unsv switch ,socket ,fan regulator and making of light / power point in casing caping upto 2 mtr of length and maintenance work complete on all working days including holidays all as directed by Engr-in-charge, at DK-2 and adjoining area.
Note for item No 23 & 24:- Supply items from ser No 27 to 69 are used against this job.
2500
-
-
... More
Attending to Geyser complaints at site including checking and rectification of any electric fault/ water leakage and making good in all respects including minor repairs, replacement of unserviceable spares, burnt copper wire connections wherever required and repairing any type of switch, socket, plug top etc complete all as specified and directed. Notes for Item No. 23,24 & 25
(a) fixtures / fittings shall be paid under relevant item against supply only.
(b) Contractors are advised to visit the sites before quoting their rates.
(c) Materials for minor and maintenance repair works as directed by Engineer-in-Charge shall be supplied by the contractor within one week from the date of issue of work order. (e) Contractor shall provide and deploy adequate experienced professional to carry out day to day complaints and must deploy 01 electrician and 01 helper at DK-2 Complaint cell from 0900Hrs to 1700 Hrs from Monday to Sunday. Electrician and helper shall report to DK-2 complaint cell at 0900 hrs daily and get the job card for carry out the work and same will be retrun to concered JE at 1700 hrs as token of completion of job. In case of any breakdown/ emergency, contractor shall make arrangement to attend and rectify the complaints in odd hours on sunday/ holiday also. The rates quoted in sch 'A' respective items shall be deemed to be included and nothing extra shall be admissible on this account.
Note: whatever be the nature of electrcal complaint the wholesole rectification responsibilty lies with the contractor. (f) Contractor shall be penalised @ Rs. 100/- per complaint per day, if he fails to attend the complaint within 4 hours.
(g) All ser numbered complaint docket will be provided by contractor and amount of docket included in this.
(h) Daily attendance register will be maintained by conserned JE and if any electrician/ helper found absent on any working day then penalty @Rs 1000/- per day per workman will be recoverd from the contractor.
Note for item No 25:- Supply items from ser No 70 to 77 to are used against this job.
780
-
-
... More
Attending to electrical complaint of no light / short circuit in light or power circuit / MCCB tripping or any other emergency nature complaint during night hours (from 09 pm to 05 am).
Notes for Item No. 26
(a) fixtures / fittings shall be paid under relevant item against supply only.
(b) Contractors are advised to visit the sites before quoting their rates.
(c) Materials for minor and maintenance repair works as directed by Engineer-in-Charge shall be supplied by the contractor within one week from the date of issue of work order. (e) Contractor shall provide and deploy adequate experienced professional to carry out day to day complaints and must deploy 01 electrician at DK-2 Complaint cell from 2100 Hrs to 0500 Hrs from Monday to Sunday . Electrician shall report to complaint cell at 2100 hrs daily . In case of any breakdown/ emergency, contractor shall make arrangement to attend and rectify the complaints in odd hours on sunday/ holiday also. The rates quoted in sch 'A' respective items shall be deemed to be included and nothing extra shall be admissible on this account.
Note: whatever be the nature of electrcal complaint the wholesole rectification responsibilty lies with the contractor. (f) Contractor shall be penalised @ Rs. 100/- per complaint per day, if he fails to attend the complaint within 4 hours.
(g) Daily attendance register will be maintained by converned JE and if any electrician/ helper found absent on any working day then penalty @Rs 1000/- per day per workman will be recoverd from the contractor.
Note for item No 26:- Supply items from ser No 78 to 86 to are used against this job. Note:- For Ser Item No 23 to 26 will be entered in MB with reference to date docket no and bldg no each.
For Item No 27 to 86 IV and RV of material will be enclosed with the payments.
750
-
-
... More
Supply only switch piano flush button type single pole one way 6 Amps all as specified.
100
-
-
... More
Supply only switch piano 6 amp SP two way, ISI marked.
5
-
-
... More
Supply only socket piano outlet 6 Amp flush button type all as specified.
70
-
-
... More
Supply only bell push single pole 6 Amps all as specified.
20
-
-
... More
Supply only switch piano flush button type single pole 16 Amps.
80
-
-
... More
Supply only socket piano outlet, 2 in 1, 3 pin 6 and 16 Amp single pole .
80
-
-
... More
Supply only Ceiling fan regulator electronic step switch type/socket type, suitable for 1200/1400 mm sweep ceiling fan, 230 Volts single phase complete.
50
-
-
... More
Supply only switch Modular type 6 Amps one way 230V AC complete all as specified and directed by Engineer in charge.
180
-
-
... More
Supply only switch Modular type 6 Amps two way 230V AC complete all as specified and directed by Engineer in charge. Make:- IndoAsian, Legrand or Havells.
5
-
-
... More
Supply only replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.
10
-
-
... More
Supply only Modular socket outlet 5 pin 6 Amp socket 2 moduler complete all as specified and directed by Engineer in charge.
90
-
-
... More
Supply only switch Modular type 16 Amps one way 230V AC complete all as specified and directed by Engineer in charge.
80
-
-
... More
Supply only Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
80
-
-
... More
Supply only Modular five stepped type electronic fan regulator 1/2 module 230V AC complete all as specified and directed by Engineer in charge.
30
-
-
... More
Supply only ceiling rose surface PVC type with three terminals.
60
-
-
... More
Supply only Electric bell Ding-Dong AC 230 Volt etc complete all as specified and directed.
30
-
-
... More
Supply only insulated body, angle holder (metal ring) with back plate ISI marked complete all as directed.
50
-
-
... More
Supply only industrial metal clad plug top, 3 pin, 10amp / 20 amp (ISI marked) as directed.
40
-
-
... More
Supply only industrial metal clad socket 3 pin 10 amp / 20 amp (ISI marked) as directed.
40
-
-
... More
Supply only relacement plug top 16 Amps 3 pin 230- volts.
10
-
-
... More
Supply only LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI80, Power Factor 0.95, THD 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed
200
-
-
... More
Supply only LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI 80, power factor 0.95, THD 10%, color temperature 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
90
-
-
... More
Supply only LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor 0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency 85%, THD10%, CRI80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
30
-
-
... More
Supply only surface ceiling mounted, round LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI 80, Power Factor 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
19
-
-
... More
Supply only in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base.
30
-
-
... More
Supply only 14W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz
120
-
-
... More
Supply only 9 W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz,
120
-
-
... More
Supply only MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'B' curve complete.
45
-
-
... More
Supply only MCB DP 20 Amps 240 volts 10 KA 50 HZ 'B' curve complete.
40
-
-
... More
Supply only MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
100
-
-
... More
Supply only MCB DP 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
10
-
-
... More
Supply only MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .
4
-
-
... More
Supply only MCCB 125 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .
4
-
-
... More
Supply only single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB SP 20 Amp complete all as specified and directed.
20
-
-
... More
Supply only PVC Gang box surface type heavy duty suitable for single switch 5 Amps.
10
-
-
... More
Supply only Gang box surface type heavy duty suitasble for 15 Amps switch and socket.
10
-
-
... More
Supply only replacement white cover plate with frame 1 module/ 2 module complete all as specified and directed by Engineer in charge.
9
-
-
... More
Supply only replacement white cover plate with frame 3 module complete all as specified and directed by Engineer in charge.
9
-
-
... More
Supply only replacement white cover plate with frame 6 module complete all as specified and directed by Engineer in charge.
9
-
-
... More
Supply only replacement white cover plate with frame 8 module complete all as specified and directed by Engineer in charge.
20
-
-
... More
Supply only hylum sheets 3 mm thick (ISI marked) of the following sizes :-
-
-
-
... More
T Cover
100
-
-
... More
Sheet 4" x 4" two cuttings suitable for two piano switches
10
-
-
... More
Sheet 4" x 7" three cuttings suitable for three piano switches
10
-
-
... More
Sheet 4" x 7" one cutting for 6 Amp socket and two cuttings for piano switches
10
-
-
... More
Sheet 8" x 10" incl cuttings for switches and sockets 6/16Amps as directed.
10
-
-
... More
Sheet 10" x 12" incl cuttings for switches and sockets 6/16Amps as directed.
5
-
-
... More
Supply only replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed.
130
-
-
... More
Supply only replacement of capacitor 1.5 Mfd, 240 V complete all as specified and directed.
60
-
-
... More
supply only hole fastner madeup of MS 6" long with complete nut bolt all as specified.
60
-
-
... More
supply only hole fastner madeup of MS 4" long with complete nut bolt all as specified.
70
-
-
... More
Supply only heating element of 2 KW any type with nut bolt washer complete all as directed.
90
-
-
... More
Supply only heating element of 1.5 KW any type with nut bolt washer complete all as directed.
86
-
-
... More
Supply only non return valve 15mm dia (ISI Marked) for geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as directed.
20
-
-
... More
Supply only for safety pressure valve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge.
30
-
-
... More
Supply only thermostat for 25/35/50 ltrs capacity of geysers complete all as directed.
30
-
-
... More
Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed.
60
-
-
... More
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 1.5 sqmm with approved colour code completed all as specified.
180
-
-
... More
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 2.5 sqmm with approved coloured code completed all as specified.
90
-
-
... More
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 4 sqmm with approved coloured code completed all as specified.
180
-
-
... More
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 6 sqmm with approved coloured code completed all as specified.
90
-
-
... More
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 10 sqmm with approved coloured code completed all as specified.
100
-
-
... More
Supply only replacement copper cable flexible 3 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge.
180
-
-
... More
Schedule of Credit
-
-
-6707
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%