Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date24 May 2024
Closing Date10 Jun 2024
Tender Amount₹ 16,72,822 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply only starting capacitor 100-120 Mfd suitable for AC upto 2.0 Ton complete all as specified and as directed. Make :- Arcos/Epcos/Tesla

2

-

-

... More
Supply only Running capacitor 36 mfd 230 volt suitable for AC 1.5 Ton complete all as specified and as directed. Make :- Arcos/Epcos/Tesla

4

-

-

... More
Supply only Running capacitor combination 50 mfd + 6 mfd 230 Volt for AC upto 2.0 Ton complete all as specified and as directed. Make :- Arcos/Epcos/Tesla

5

-

-

... More
Supply only Running capacitor 6 mfd 230 volt complete all as specified and as directed. Make : Arcos/Epcos/Tesla

5

-

-

... More
Supply only Running capacitor 4 mfd 230 volt complete all as specified and as directed. Make :- Arcos/Epcos/Tesla

4

-

-

... More
Supply & charging gas refrigerant R-22/R 410 A/ R-32 or as existing to split type AC up to 2 Ton capacity and testing complete all as specified & directed by Engineer-in-charge. Make- Mafron/Refron/Refromax

20

-

-

... More
Supply only starting relay suitable for 1.5/2 Ton capacity AC complete all as specified and as directed.

2

-

-

... More
Supply only over load protector suitable for 1.5/2.0 Ton capacity AC complete all as specified and as directed.

2

-

-

... More
S & F in replacement of defective /unserviceable reciprocating compressor of split type AC capacity 1.5 TR, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make : Kirloskar/Carrier/Tecumseh/Copeland/ existing make

1

-

-

... More
All as per item No 12 here-in-before but ratary compressor of Split type Acs 1.5 TR complete all as specified and as directed.

1

-

-

... More
All as per item No 12 here-in-before but ratary compressor of Split type Acs 2.0 TR complete all as specified and as directed.

1

-

-

... More
Supply & fix in replacement air filter synthetic/ nylon as per existing size and shape suitable for 1.5/2 Ton capacity split type ACs complete all as specified and as directed.

1

-

-

... More
Material and labour for taking down existing unserviceable blower motor (Indoor) capacity 1/4,1/5 HP single/double shaft as per existing and refixing with new blower motor in replacement as per existing model on site suitable for Split type ACs 1.5/2 Ton complete all as specified and directed. Make:-As per existing

1

-

-

... More
Material and labour for taking down existing unserviceable outdoor fan motor and fixing of new fan motor capacity 1/4,1/5 HP single/double shaft as per existing model suitable for Split type ACs 1.5/2 Ton complete all as specified and directed. Make:-As per existing

1

-

-

... More
Material and labour for taking down existing unserviceable outdoor fan motor capacity upto 2 Ton and taking the unserviceable fan motor outdoor type to authorized workshop for rewinding of fan motor suitable for ACs capacity up to 2 Ton capacity with super enameled copper winding wire of same gauge including replacement of insulating material, bushes and shaft all as specified & directed.

1

-

-

... More
Supply & fix in replacement PVC insulated flexible copper conductor 3 core 1100V Grade of size 2.5 sqmm complete all as specified and as directed.

60

-

-

... More
All as per item No 19 here-in-before but 4 sqmm complete all as specified and directed.

90

-

-

... More
Supply & fix in replacement condensor fan blade suitable for 1.5/ 2.0 Ton capacity split type Acs complete all as specified and directed.

2

-

-

... More
Supply & fix in replacement of evaporating air blower made out of aluminium suitable for 1.5/2.0 Ton capacity for split type AC all as specified and directed

1

-

-

... More
Supply and fix in replacement of synthetic rubber tube insulation of thickness internal diameter (1/4") for refrigerant copper piping of split AC units complete all as specified and directed. Make:- Supreme/Gulf-o-flex/Superlon.

20

-

-

... More
All as per item No 23 here-in-before but internal dia (1/2") complete all as specified and directed.

20

-

-

... More
All as per item No 23 here-in-before but internal dia (3/8") complete all as specified and directed.

10

-

-

... More
All as per item No 23 here-in-before but internal dia (6/8") complete all as specified and directed.

10

-

-

... More
Supply and fix in replacement copper tubing heavy duty inner dia (1/4") for refrigerant for Split type ACs capacity upto 2 Ton complete all as specified and directed. Make-Carrier/ Totalline/Mandev

20

-

-

... More
All as per item No 27 here-in-before but internal dia (1/2") complete all as specified and directed.

20

-

-

... More
All as per item No 27 here-in-before but internal dia (3/8") complete all as specified and directed.

10

-

-

... More
All as per item No 27 here-in-before but internal dia (6/8") complete all as specified and directed.

10

-

-

... More
Material and labour for taking down existing condensing coil by removing it from existing outdoor unit by using LPG blower and fixing of new condensing coil of suitable size/capacity for 1.5/2 Ton split type ACs complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil

1

-

-

... More
Material and labour for taking down existing evaporating coil by removing it from existing indoor unit by using LPG blower and fixing of new evaporating coil of suitable size of existing make, capacity for 1.5/2 Ton split type ACs complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil.

1

-

-

... More
Material and labour for checking the leakage by feeding dry Nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas R-12/22/134a or existing type gas for water cooler, Split type/Window type/tower/ductable AC/ Deep Freezer /Refrigerator any size any capacity as on site complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
Supply & fix in replacement brass flare nut/connector heavy duty of size (1/4", 1/2",3/8",6/8) as per existing make complete all as specified and as directed.

10

-

-

... More
Material and labour for Repair of processing control board including replacement of current transformer, ICs, diodes, resistances, sensors etc complete for 1.5/2 Ton split type ACs of any make & model complete all as specified and as directed.

1

-

-

... More
Supply and fix in replacement of unserviceable PCB suitable for Split type AC 1.5/2 Tr complete all as specified and directed. Make-Hitachi/Voltas/Carrier/Daikin

1

-

-

... More
Supply and fix in replacement of unserviceable PCB unit and fixing of new PCB unit suitable for Indoor unit of capacity1.5/2 Ton inverter split type AC complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply and fix in replacement of unserviceable PCB and fixing of new PCB suitable for Outdoor unit of 1.5/2 Ton inverter split type AC complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Material and labour for taking down unserviceable condensor fan motor of outdoor unit inverter type and supply and fix new DC motor of existing capacity suitable for outdoor unit of Inverter type AC of capacity 1.5/2.0 Ton complete all as specified and as directed by engr-in-Charge

1

-

-

... More
Material and labour for taking down existing unserviceable compressor of Inverter type AC 1.5/2 TR and replacement of same by new hermetically sealed rotary compressor of capacity suitable for Inverter type AC 1.5/2 Ton refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge

1

-

-

... More
Supply and fix in replacement split type AC indoor unit kit 1.5 TR capacity complete with cooling coil, blower with motor, PCB and remote complete with fixing plate suitable to existing model and make AC complete all as specified and directed. Make- Hitachi/Daikin/LG.

1

-

-

... More
Supply and fix in replacement split type AC outdoor kit 1.5 TR complete with compressor,copper tubing,insulation,condensing coil, condensor fan motor suitable to existing model and make iron grill, suitable for outdoor unit and flair nuts for connection of Copper pipe complete all as specified and directed. Make- Hitachi/Daikin/LG.

1

-

-

... More
All as per item No 41.00 here-in-before but split type AC indoor unit lit 2.0 TR complete all as specified and directed.

1

-

-

... More
All as per item No 42.00 here-in-before but split type AC outdoor unit lit 2.0 TR complete all as specified and directed.

1

-

-

... More
Supply & fix in replacement direction changer louver motor ( swing motor) suitable for split type ACs 1.5/2 capacity as per existing make and model complete all as specified and directed.

1

-

-

... More
Supply & fix in replacement cordless Remote for split inverter type ACs suitable for 1.5/2 Ton AC as per sample complete all as specified and directed. Make- Hitachi/Voltas/Carrier/LG

1

-

-

... More
Supply & fix in replacement cordless Remote for split ACs suitable for 1.5/2 Ton AC as per sample complete all as specified and directed. Make- Hitachi/Daikin/LG/Carrier

1

-

-

... More
Material and labour for Shifting of Split type Acs 1.5 /2.0 TR capacity to new location including wooden frame,ply of required size removing of indoor unit, out door unit and connected accessories complete all as specified and directed by Engr -in- charge.

1

-

-

... More
Material & labour for servicing of ductable AC 8.5 Ton capacity complete with blower motor dismantling all parts carefully and carryout servicing, cleaning the external surface (both side) and fan of the unit out side of the equipment like base plate runner fan blade thoroughly with the help of descaling chemical, brush, water, air blower and dry properly complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement defective /unserviceable scroll compressor of capacity 8.5 TR ductable AC, refixing new compressor of 8.5 Ton including brazing work etc, pressure testing & establishing vacuum for dehydration of three phase compressor complete all as specified and directed by Engr-in-Charge. Make: Kirloskar/Emerson/Hitachi/existing make ACs complete all as specified.

1

-

-

... More
Supply & charging the gas refrigerant R-22/R 410 A or as existing to Ductable type AC's of capacity 8.5 Ton capacity including removing of leakage if any and testing complete all as specified & directed.

10

-

-

... More
Supply and fix in replacement of LP cut-out suitable for ductable type ACs of capacity 8.5 Ton complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement of HP cut-out suitable for Ductable type ACs of capacity 8.5 Ton complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement of expansion valve suitable for Ductable type ACs of capacity 8.5 Ton complete all as specified and directed.

1

-

-

... More
supply and fix in replacement of old U/S indoor motor 370 watt 220 volt 50 HZ, single/double shaft as per existing model suitable for ductable AC's of capacity 8.5 Ton complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
supply and fix in replacement of old U/S outdoor motor 150 watt 220 volt 50 HZ, single/double shaft as per existing model suitable for ductable AC's of capacity 8.5 Ton complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
Supply and fix in replacement of air filter synthetic / nylon type as per existing size and shape suitable for ductable AC's of capacity 8.5 Ton complete all as specified and as directed by Engr-in-Charge..

1

-

-

... More
supply and fix in replacement of unserviceable PCB unit and fixing of new PCB unit suitable for ductable AC of capacity 8.5 Ton complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Material & labour for servicing of tower type AC 4.0 Ton capacity complete with blower motor dismantling all parts carefully and carryout servicing, cleaning the external surface (both side) and fan of the unit out side of the equipment like base plate runner fan blade thoroughly with the help of descaling chemical, brush, water, air blower and dry properly complete all as specified and directed.

4

-

-

... More
Supply and fixing in replacement of defective /unserviceable scroll compressor of capacity 4.0 TR tower AC, including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make: Kirloskar/Emerson/Hitachi/existing make ACs complete all as specified and directed.

1

-

-

... More
Supply & charging the gas refrigerant R-22/R 410 A or as existing to Tower AC's of capacity 4.0 Ton capacity including removing of leakage if any and testing complete all as specified & directed.

10

-

-

... More
Supply and fix in replacement of LP cut-out suitable for tower type ACs of capacity 4.0 Ton complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement of HP cut-out suitable for Tower type ACs of capacity 4.0 Ton complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement of expansion valve suitable for Tower type ACs of capacity 4.0 Ton complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement of old U/S PCB suitable for 4.0 Ton tower AC complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply and fix in replacement of old U/S evaporating air blower made out of aluminium/plastic suitable for tower AC's of capacity 4.0 Ton complete all as specified and as directed by Engr-in-Charge..

1

-

-

... More
Supply and fix in replacement of old U/S fan motor single/double shaft as per existing model suitable for tower AC's of capacity 4.0 Ton complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
Material & labour for servicing of VRV/VRF AC 3.0 Ton capacity complete with blower motor dismantling all parts carefully and carryout servicing, cleaning the external surface (both side) and fan of the unit out side of the equipment like base plate runner fan blade thoroughly with the help of descaling chemical, brush, water, air blower and dry properly complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement of defective /unserviceable scroll compressor of capacity 3.0 TR VRV AC, including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make: Kirloskar/Emerson/Hitachi/existing make ACs complete all as specified and directed.

1

-

-

... More
Supply & charging the gas refrigerant R-22/R 410 A or as existing to VRV AC's of capacity 3.0 Ton capacity including removing of leakage if any and testing complete all as specified & directed.

4

-

-

... More
Supply and fix in replacement of old U/S PCB suitable for 3.0 Ton VRV AC complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Material & labour for servicing of VRV/VRF AC 4.0 Ton capacity complete with blower motor dismantling all parts carefully and carryout servicing, cleaning the external surface (both side) and fan of the unit out side of the equipment like base plate runner fan blade thoroughly with the help of descaling chemical, brush, water, air blower and dry properly complete all as specified and directed. Note: outdoor unit - 06 HP Indoor unit - 4 TR

9

-

-

... More
Material & labour for servicing of VRV/VRF AC 4.0 Ton capacity complete with blower motor dismantling all parts carefully and carryout servicing, cleaning the external surface (both side) and fan of the unit out side of the equipment like base plate runner fan blade thoroughly with the help of descaling chemical, brush, water, air blower and dry properly complete all as specified and directed. Note: outdoor unit - 26 HP-01 No Indoor unit - 7.8 TR-03 Nos

3

-

-

... More
Material and labour for Servicing of Water cooler of 40,120,150 ltr capacity of any make / model by cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning, greasing, oiling of fan motor and checking of electric circuit for smooth functioning complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
Supply & charging the gas refrigerant R-134 or as existing to water coolers up to 150 ltr capacity including removing of leakage if any and testing complete all as specified & directed

5

-

-

... More
S & F in replacement of defective /unserviceable reciprocating compressor of Water Cooler 120-150 L & refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make:- Kirloskar/Tecumseh/Copeland/Emersons

1

-

-

... More
S & F in replacement of old U/S condensing coil of water cooler any capacity including brazing and dehydration by creating vacuum for more than 24 Hrs so that no oil/sludge remains in the cooling coil/system Complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
S & F in replacement of old U/S fan motor of water cooler capacity upto 150 Litres along with fan blade complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
Material and labour for Servicing of Refrigerators of 195 to 310 ltr capacity single door of any make / model by cleaning of condensing coil with wire & brush to remove dust including checking of electric circuit for smooth functioning complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
S & F in replacement of old U/S condensing coil of refrigerator of capacity upto 310 Ltr including brazing and dehydration by creating vacuum for more than 24 Hrs so that no oil/sludge remains in the cooling coil/system Complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
S & F in replacement of old U/S fan motor of refrigerator capacity upto 310 Litres along with fan blade complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
S & F in replacement of defective /unserviceable reciprocating compressor of refrigerator 310 Ltr & refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make:- Kirloskar/Tecumseh/Copeland/Emersons

1

-

-

... More
Supply & charging the gas refrigerant R-134a or as existing to Refrigerators up to 310 ltr capacity including removing of leakage if any and testing complete all as specified & directed

0.2

-

-

... More
Supply & fix in replacement of unserviceable starting relay suitable for 195 to 310 ltr capacity Refrigerator complete all as specified and directed.

1

-

-

... More
Supply & fix in replacement of unserviceable over load protector suitable for Refrigerator capacity upto 310 ltrs complete all as specified and directed.

1

-

-

... More
Supply & fix in replacement thermostat switch suitable for Refrigerator capacity upto 310 L complete all as specified and directed.

1

-

-

... More
Material and labour for Servicing of Deep freezer upto capacity 1300 Ltr 2/3/ 4 door of any make / model quarterly by cleaning of condensing coil with wire & brush to remove dust ,oiling and greasing as required including checking of electric circuit for smooth functioning complete all as specified and directed by Engr-in-Charge

11

-

-

... More
Supply & charging the gas refrigerant R-134a or as existing to Deep Freezers up to 1300 ltr capacity including removing of leakage if any and testing complete all as specified & directed

0.5

-

-

... More
S & F in replacement of old U/S condensing coil of deep freezer of capacity 1300 Ltr including brazing and dehydration by creating vacuum for more than 24 Hrs so that no oil/sludge remains in the cooling coil/system Complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
S & F in replacement of old U/S condensor fan motor of deep freezer capacity 1300 Ltr along with fan blade complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
S & F in replacement of old U/S condensor fan motor of deep freezer capacity 492 Ltr along with fan blade complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
S & F in replacement of defective /unserviceable reciprocating compressor of deep freezer of capacity 492 Ltr & refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make:- Kirloskar/Tecumseh/Copeland/Emersons

1

-

-

... More
S & F in replacement of defective /unserviceable reciprocating compressor of deep freezer of capacity 1300 Ltr & refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make:- Kirloskar/Tecumseh/Copeland/Emersons

1

-

-

... More
Supply & fix in replacement of unserviceable starting relay suitable for 165 to 1300 ltr capacity Deep freezer complete all as specified and directed.

1

-

-

... More
Supply & fix in replacement of unserviceable over load protector suitable for Deep freezer capacity upto 1300 L complete all as specified and directed.

1

-

-

... More
Supply & fix in replacement thermostat switch suitable for Deep Freezer upto 1300 L complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement of PVC insulated and PVC sheathed, flexible copper conductor cable 3 core, 1100 volts grade, multi stranded type of size 6.0 sqmm complete all as specified.

90

-

-

... More
Material and labour for taking down of desert cooler and Servicing of Desert cooler of any type/ capacity, cleaning of tank including checking of electric circuit for smooth functioning of desert cooler complete all as specified and directed.

90

-

-

... More
Supply and fix in replacement of desert cooler pad for desert cooler (PVC Body type) complete (in set of three) as per sample suitable for cooler of Size as required at site complete all as specified & directed.

20

-

-

... More
Supply & fix in replacement ON/OFF switch of desert cooler complete all as specified and directed.

10

-

-

... More
Supply & fix in replacement of step type regulator desert cooler regulator complete all as specified and directed.

20

-

-

... More
Supply & fix in replacement of drain pipe PVC flexible, spring type of size 15 mm dia as per site requirement complete all as specified and directed.

20

-

-

... More
Supply & fix in replacement of water lifting pump for desert cooler of any capacity as per sample complete all as specified and directed by Engr-In-Charge.

20

-

-

... More
Supply and fix in replacement of desert cooler fan motor with supper enameled copper winding wire of same gauge (as per sample) complete all as specified and directed.

20

-

-

... More
M & L for servicing of RO Plant of capacity upto150 LPH including replacement of minor spares,cleaning of filters/membranes and refixing the RO after repair, testing complete all as specified and directed of entire satisfactory level by Engr-in charge. Note: Spares required shall be measured and paid under relevant items of Sch from Item No 106 to 118

15

-

-

... More
Supply only Membrane suitable for 50 to 150 LPH RO Plant complete all as specified and directed.

30

-

-

... More
Supply only Membrane housing suitable for 50 to 150 LPH RO Plant complete all as specified and directed.

15

-

-

... More
Supply only Filter heavy Grade suitable for 50 to 150 LPH RO Plant complete all as specified and directed.

15

-

-

... More
Supply only Solenoid valve suitable for 50 to 150 LPH RO Plant complete all as specified and directed.

20

-

-

... More
Supply only activated carbon Filter heavy Grade for 50 to 150 LPH RO Plant complete all as specified and directed.

20

-

-

... More
Supply only HDPE pipe 3/8"dia suitable for inlet & outlet of RO plant complete all as specified and directed.

40

-

-

... More
Supply only booster pump for 50 to 150 LPH RO Plant complete all as specified and directed.

18

-

-

... More
Supply only CTO Filter suitable for 50 to 150 LPH RO Plant complete all as specified and directed.

10

-

-

... More
Supply only SMPS suitable for 50 to 150 LPH RO Plant complete all as specified and directed.

15

-

-

... More
Supply only UV tube suitable for 50 to 150 LPH RO Plant complete all as specified and directed.

10

-

-

... More
Supply only UV barrel housing suitable for 50 to 150 LPH RO Plant complete all as specified and directed.

15

-

-

... More
Supply only high pressure switch suitable for 50 to 150 LPH RO Plant complete all as specified and directed.

10

-

-

... More
Supply only low pressure switch suitable for 50 to 150 LPH RO Plant complete all as specified and directed.

10

-

-

... More
Comprehensive maintenance and servicing of water treatment plant (INDROMATIC-402,sand filter,Antiscalent doser) including through checking of all parts,additional visit of engineer /supervisor to ensure that system work smoothly during entire contract period. Comprehensive maintenance also include chemical cleaning of plant and replacement of all parts such as filter media,carbon media,cartridge,RO Membrane,Antiscalent chemical,repair high pressure and raw water pump etc. complete all as specified and directed. Note:-Chemical cleaning of plant should be done on quarterly basic.

4

-

-

... More
S&F in replacement of switch piano flush type 6 Amp, SP, one way 230 volts AC complete all as specified and directed. Make:-Havells/indoasian/anchor

250

-

-

... More
S&F in replacement of switch piano flush type 6 Amp SP two way 230 volts AC complete all as specified and directed. Make:-Havells/indoasian/anchor

10

-

-

... More
S&F in replacement of bell push switch piano flush type 6 Amps, SP, 230 Volts AC complete all as specified and directed. Make:-Havells/indoasian/anchor

20

-

-

... More
S&F in replacement of switch piano flush type 16 Amp, SP, one way 230 volts AC complete all as specified and directed. Make:-Havells/indoasian/anchor

180

-

-

... More
S&F in replacement of piano flush type socket out let 5 pin 6 Amp, 230 volts AC complete all as specified and directed. Make:-Havells/indoasian/anchor

160

-

-

... More
S&F in replacement of piano flush type socket out let 6 pin 16 Amp, 230 volts AC complete all as specified and directed. Make:-Havells/indoasian/anchor

150

-

-

... More
S&F in replacement of piano type electronic fan regulator suitable for 1200/1400 mm ceiling fan complete all as specified and directed. Make:-Havells/indoasian/anchor

150

-

-

... More
S&F in replacement of call bell suitable for 230 volts AC complete all as specified and directed.

20

-

-

... More
S&F in replacement of ceiling rose 3 terminal / PVC / Polycarbonate, insulated body complete all as specified and directed.

20

-

-

... More
S&F in replacement of decorative lamninated sheer 3 mm thick of size 9"x13" including necessary cutting of sheet for fixing switch/socket complete all as specified and directed.

8

-

-

... More
S&F in replacement of decorative lamninated sheet 3 mm thick of size 9"x11" including necessary cutting of sheet for fixing switch/socket(As per enclosed diagram) complete all as specified and directed.

6

-

-

... More
S&F in replacement of decorative lamninated sheet 3 mm thick of size 8"x5" including necessary cutting of sheet for fixing switch/socket (As per enclosed diagram) complete all as specified and directed.

5

-

-

... More
S&F in replacement of decorative lamninated sheet 3 mm thick of size 5"x5" including necessary cutting of sheet for fixing switch/socket(As per enclosed diagram) complete all as specified and directed.

5

-

-

... More
S&F in replacement of single core,FRLS cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 1.5 Sqmm complete all as specified and directed. Make:RR/POLYCAB/HAVELLS

360

-

-

... More
S&F in replacement of single core,FRLS cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 2.5 Sqmm complete all as specified and directed. Make:RR/POLYCAB/HAVELLS

200

-

-

... More
S&F in replacement for MCB SP 06 to 32 Amps 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and directed by Engr-in-Charge. Make:-Indoaisian/Havells/legrand

150

-

-

... More
S&F in replacement for MCB SPN 32 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and directed by Engr-in-Charge. Make:-Indoaisian/Havells/legrand

50

-

-

... More
S&Fin replacement MCB TPN/ Isolator 4P ,63 Amps 415 volts, 'C' Series 10 KA as per site requirement complete all as specified and directed. Make:-Indoaisian/Havells/legrand

1

-

-

... More
S&F in replacement of MCCB TP 125 Amp, 415 Volts,36kA thermal type complete complete all as specified and directed. Make:-Indoaisian/Havells/legrand

1

-

-

... More
S&F in replacement of MCCB TP 160 Amp, 415 Volts ,36kA adjustable type complete all as specified and directed. Make:-Indoaisian/Havells/legrand

2

-

-

... More
S&F in replacement of MCCB TP 250 Amp,415 Volts, 36kA thermal type complete all as specified and directed. Make:-Indoaisian/Havells/legrand

2

-

-

... More
S&F in replacement of metal clad plug top 20 Amp, 230 volts AC complete all as specified and directed.

2

-

-

... More
S&F in replacement of metal clad socket outlet 20 Amps, 230 volts AC complete all as specified and directed.

2

-

-

... More
S&F in replacement of LED Batten fitting 10 watt - 2FT White, indoor decorative aluminium extruded complete all as specified and directed. Make : Havells or equivalent Model in Crompton/Philips.

80

-

-

... More
S&F in replacement of LED Batten fitting 20 watt LED White, indoor decorative aluminum extruded complete all as specified and directed. Make : Havells or equivalent Model in Crompton/Philips/Bajaj.

300

-

-

... More
S&F in replacement Decorative wall light made up of high grade engineering plastic material suitable for 9 W LED lamp B22 base complete all as specified and directed. Make: Havells Cat LHFHCHE1TL1W020 or equivlent make in Crompton/Phillips.

24

-

-

... More
S&F in replacement of LED Building security light fitting 25W energy saving and environmental friendly made up of pressure diecast aluminium housing with high power LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protectioncomplete all as specified and directed. Make:-Havells or equivqlent model in Crompton/Phillips

10

-

-

... More
S&F in replacement of B-22 holder suitable for Led bulb 9-15 watts complete all as specified and directed.

50

-

-

... More
S&F in replacement of fan capacitor 2.5 Mfd complete all as specified and directed.

120

-

-

... More
S&F in replacement of fan capacitor 3.15 Mfd complete all as specified and directed.

20

-

-

... More
S&F in replacement of old unserviceable /burnout winding Ceiling Fan 1200/1400 mm with new 1200 mm sweep BLDC 5 satr rated ceiling fan of color White complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and making arrngement to hanging of fan to ceiling with proper hook nut bolt complete all as specified and directed. Make Havells/Orient/crompton Note:-The old U/S ceiling fan 1200/1400mm sweep deposited to MES store yard in safe custody.

80

-

-

... More
S&F in replacement of ceiling fan Ball bearing of suitable size & model complete all as specified and directed. Make:- NBC/ SKF

20

-

-

... More
S&F in replacement of 'U' clamps with rubber reel, bolts, nuts, washers and safety pin ceiling fan of any size/ make complete all as specified and directed.

40

-

-

... More
S&F in replacement of Down rod of 1' height fabricated out of MS pipe 12mm dia heavy duty duly painted with one coat of white paint complete all as specified and directed.

20

-

-

... More
S&F in replacement of Canopy of Celing fans of 1200/1400mm swipe size heavy duty duly painted with one coat of white paint complete all as specified and directed.

40

-

-

... More
S&F in replacement of blade (set of three) of Celing fans of 1200/1400mm swipe size heavy duty duly painted with one coat of white paint complete all as specified and directed.

10

-

-

... More
S&F in replacement of blade (set of three) of exhaust fans metal body of 300 mm swipe size heavy duty duly painted with one coat of paint of suitable colour complete all as specified and directed.

16

-

-

... More
S&F in replacement of metal frame of exhaust fans metal body of 300 mm swipe size heavy duty duly painted with one coat of paint of suitable colour complete all as specified and directed.

18

-

-

... More
S&F in replacement of motor (copper winding) of exhaust fans metal body of 300 mm swipe size heavy duty duly painted with one coat of paint of suitable colour complete all as specified and directed.

60

-

-

... More
M&L for spray painting two coat (white colour) with synthetic enamel paint to Ceiling fans/Exahust fan of any capacity to reach upto satisfied finish of painting after cleaning and preparation of surface complete all as specified and directed by Engineer-in-charge.

20

-

-

... More
M&L for spray painting two coat (white colour) with synthetic enamel paint to Geysers 25/50 Liters capacity to reach upto satisfied finish of painting after cleaning and preparation of surface complete all as specified and directed by Engineer-in-charge.

2

-

-

... More
S&F in replacement of heating element of 1.5 KW (triangular/circular) as required at site including rubber washers (ISI marked) etc complete all as specified and directed.

5

-

-

... More
S&F in replacement of heating element of 2.0 KW (triangular/circular) as required at site including rubber washers (ISI marked) etc complete all as specified and directed.

5

-

-

... More
S&F in replacement of storage tank made out of stainless steel sheet of appropriate thickness ) for 25 litre capacity geysers with collar complete duly tested at required pressure complete all as specified and directed.

10

-

-

... More
S&F in replacement of insulating material (Glass wool) for 25 litre capacity Geysers complete all as specified and directed.

10

-

-

... More
S&F in replacement of base plate assembly 20 SWG heavy duty suitable for 25 litre capacity stainless steel tank geyser with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element including clamps for holding the element with nuts, bolts and safety valves suitable for all type of geysers installed at site complete all as specified and directed.

10

-

-

... More
S&F in replacement of chromium plated connection pipe 600mm long with two brass adopters washers and connecting up complete complete all as specified and directed.

10

-

-

... More
S&F in replacement of PVC connection pipe 450mm long with two brass adopters washers and connecting up complete ISI mark complete all as specified and directed by Engr-in Charge

10

-

-

... More
S&F in replacement of safety nut for high pressure release complete all as specified and directed.

10

-

-

... More
S&F in replacement of non return valves 15mm dia and connecting up complete (ISI marked) complete all as specified and directed.

10

-

-

... More
S&F in replacement of top cover for geysers of 25 ltrs capacity any make as required at site duly painted with two coats of Synthetic enamel spray paint (first quality) complete all as specified and directed.

10

-

-

... More
S&F in replacement of bottom cover for geysers of 25 ltr any make required at site duly painted with synthetic enamel spray paint (first quality) with inspection plate in two pieces complete all as specified and directed.

10

-

-

... More
S&F in replacement of outer cover for geyser made out of MS sheet suitable for 25 ltrs capacity geyser vertical/horigontal type all as specified and directed.

10

-

-

... More
S&F in replacement of thermostat (ISI Marked) for 25 Liters capacity Geyser complete all as specified and directed. Make : Daspass/Theeta/TTE

10

-

-

... More
S&F in replacement of indicator lamp (Red & Green) 230 volts suitable for Geyser complete all as specified and directed.

10

-

-

... More
S&F in replacement of of mild steel hole fastner 10mm dia, 100mm long including nut and washer complete all as specified and directed.

10

-

-

... More
S&F in replacement of 15 mm gun metal valve complete all as specified and directed.

10

-

-

... More
Taking down carefully old point wiring (Light / Fan/ Socket/ Bell Point ) with aluminium/ copper conductor cable complete including fittings such as ceiling rose, holders, regulators, bell, switch and socket and making good the disturbed surface of wall/ floor complete all as specified and directed.

280

-

-

... More
M&L for point wiring with PVC insulated unsheathed multi stranded, single core, FRLS type, copper conductor cable of size 1.5 sqmm 1100 Volts including one run of PVC insulated unsheathed multi stranded, single core, FRLS type, copper conductor cable of size 1.5 sqmm as earth continuity conductor connected to common earth dolly, in and including PVC concealed rigid non-metallic conduit medium grade and its accessories including provn of new galvanised sunken box including decorative sheets for housing the piano type switches, sockets & fan regulators complete all as specified and directed for the following:- Note :- In existing conduit wiring (new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes).

-

-

-

... More
One light/fan point controlled by one No, one way switch complete all as specified and directed.

200

-

-

... More
6 Amp socket outlet point controlled by one No, one way switch on same board complete all as specified and directed.

20

-

-

... More
6 Amp socket outlet point controlled by one No, one way switch on independent board complete all as specified and directed.

30

-

-

... More
M&L for point wiring with PVC insulated unsheathed multi stranded, single core, FRLS type, copper conductor cable of size 2.5 sqmm 1100 Volts including one run of PVC insulated unsheathed multi stranded, single core, FRLS type, copper conductor cable of size 2.5 sqmm as earth continuity conductor connected to common earth dolly, in and including PVC concealed rigid non-metallic conduit medium grade and its accessories including provn of new galvanised sunken box including decorative sheets for housing the piano type switces and sockets on independent board complete all as specified and directed. Note :- In existing conduit wiring (new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes). Note for item No 178 & 179:- (i) Cutting chases for concealed conduit and making good in cement mortar is deemed included in unit rate. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling point wiring. In this specified portion wire shall run through the existing conduit or surface new conduit shall be provided as required. (iii) In case the wiring is encountered with any beam/column, then the wiring will run on surface to avoid any damage to the RCC portion.

30

-

-

... More
S&F in replacement of PVC Casing Caping of size 1" complete all as specified & directed.

40

-

-

... More
S&F in replacement of PVC conduit 20mm dia, rigid, complete all as specified & directed.

140

-

-

... More
S&F in replacement of flexible PVC pipe of 20mm dia complete all as specified & directed.

100

-

-

... More
S&F in replacement of LED Glass Bulb 10 Watt B-22 Cap, AC 230V, 50 Hz, suitable for Batten Holder/Bulk head/wall light fittings complete all as specified and directed by Engineer -in-Charge. Make: havells/philips/crompton.

100

-

-

... More
S&F in replacement of single core, FRLS cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 4 Sqmm complete all as specified and as directed. Make:Polycab/Havells/RR.

90

-

-

... More
S&F in replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6 sqmm complete drawn in existing conduit along with 1x 6 sqmm PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type for continuous earth wire and connected to common earth dolly complete all as specified and directed. Make:-RR/Havells/Polycab

360

-

-

... More
S&F in replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 10 sqmm complete drawn in existing conduit along with 1x 10 sqmm PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type for continuous earth wire and connected to common earth dolly complete all as specified and directed. Make:-RR/Havells/Polycab

180

-

-

... More
S&F in replacement of metal clad enclosure with plug and socket 20 Amp with one MCB SP, 20 Amps 230 volts AC complete all as specified and directed. Make:-Havells/indoasian/legrand

2

-

-

... More
S&F in replacement of factory made concealed sheet steel distribution boards, double door, SPN, 4 way, 230 volts AC, IP 43 with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing complete all as specified and directed. Make:-Havells/indoasian/legrand

2

-

-

... More
S&F in replacement of factory made concealed sheet steel distribution boards, double door, SPN, 8 way, 230 volts AC, IP 43 with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing complete all as specified and directed. Make:-Havells/indoasian/legrand

6

-

-

... More
S&F in replacement of factory made concealed sheet steel distribution boards, double door, SPN, 12 way, 230 volts AC, IP 43 with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing complete all as specified and directed. Make:-Havells/indoasian/legrand

1

-

-

... More
S&F in replacement of factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 4 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete complete all as specified and directed. Make:-Havells/indoasian/legrand

2

-

-

... More
S&F in replacement of factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete complete all as specified and directed. Make:-Havells/indoasian/legrand

2

-

-

... More
S&F in replacement Rugby Bulk head 9 watt in die cast aluminium housing & frosted glass complete all as specified and directed by Engineer-In-Charge. Make: Havells Cat LHKL01160099 or equivlent model in Crompton/Bajaj/Phillips).

30

-

-

... More
S&F in replacement of Exhaust fan Louvers 300 mm Size of iron upto forth floor including taking out old louvers complete all as specified and directed. Note:-ladder arrangement for fixing louvers will be made by contractor.

20

-

-

... More
M&L for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as shown in drg and connected to earth test point including testing including taking down old unsv earthing complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
S&F in replacement of two core flexible cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 1 Sqmm complete all as specified and as directed.

90

-

-

... More
S&F in replacement of aesthetically designed ceiling/surface mounting circular shaped decorative green perform sleek LED downlighter of 09 W fixture with opal diffuser to give glare free light including suitable LED lamp complete all as specified and as directed.

20

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.