Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 98,700Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_687628_1Bid Award Id
ViewTender No
GE ELECT/D-84/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
S & F common burnt bricks as mechanical protection of this cables using old size sub class ‘B’ bricks laid dry flat over the cable width equal to the length complete all as specified and directed by Engineer- in- Charge.
29.4
-
-
... More
M&L for sand filling in trenches for cushioning of UG cables as layers of 8 cm before laying and 15 cm after laying of cables complete all as specified and directed by Engineer- in- Charge.
Note : Measurement shall be taken after punning down.
312.1
-
-
... More
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm for cable protection complete all as specified and directed by Engineer- in- Charge.
2916
-
-
... More
Supply, laying, testing and commissioning in replacement LT XLPE UG cable insulated, armoured heavy duty electric cable, 1100 volts grade with stranded aluminium conductor of 6 Sqmm 2 core complete including dismantling of old unserviceable cable complete all as specified and directed by Engineer- in- Charge.
500
-
-
... More
All as per Ser Item No. 7 above but 10 Sqmm 2 core.
500
-
-
... More
All as per Ser Item No. 7 above but 10 Sqmm 4 core.
300
-
-
... More
All as per Ser Item No. 7 above but 16 Sqmm 4 core.
700
-
-
... More
All as per Ser Item No. 7 above but 35 Sqmm 3.5 core.
500
-
-
... More
All as per Ser Item No. 7 above but 50 Sqmm 3.5 core.
500
-
-
... More
All as per Ser Item No. 7 above but 95 Sqmm 3.5 core.
400
-
-
... More
All as per Ser Item No. 7 above but 120 Sqmm 3.5 core.
600
-
-
... More
All as per Ser Item No. 7 above but 185 Sqmm 3.5 core.
250
-
-
... More
Supply, laying, testing and commissioning in replacement HT XLPE UG cable insulated, armoured heavy duty electric cable, 11000 Volts grade with stranded aluminium conductor of 95 Sqmm 3 core complete including dismantling of old unserviceable cable complete all as specified and directed by Engineer- in- Charge.
150
-
-
... More
All as per Ser Item No. 8 above but 120 Sqmm 3 core.
400
-
-
... More
All as per Ser Item No. 8 above but 185 Sqmm 3 core.
100
-
-
... More
M & L for GI Tubes of size 40 mm dia light grade, galvanised, with all fitting, laid in trenches for protection of cable in road /drain crossing complete all as specified and directed by Engineer- in- Charge.
24
-
-
... More
All as per Ser Item No. 9 above but 50 mm dia.
18
-
-
... More
All as per Ser Item No. 9 above but 80 mm dia.
18
-
-
... More
Supply, installing, testing and commissioning in replacement of factory made and tested (including CPRI type tested certified panel) LT Panel board ,cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The panel shall be dust and vermin proof. IP-65 class protection and shell be made of 3.15 mm CRCA MS sheet, and 50x50x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following :- (a) Incoming :-
(i) MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 36 KA, with thermal and magnetic release - 01 Nos
(ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No (iii) Ammeter digital type with 4 way rotary selector switch-01No (iv) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three (v) Indicating lamp- 01 set of three
(vi) Aluminium bus bar of rating 800 Amp- set of four (b) Outgoing :- (i) MCCB 200 Amp 4 Pole ,50 Hz,415 Volts, 36 KA with thermal magnetic release - 01 Nos. (ii) MCCB 160 Amp 4 Pole ,50 Hz,415 Volts, 36 KA with thermal magnetic release - 01 Nos. (iii) MCCB 125 Amp 4 Pole ,50 Hz,415 Volts, 25 KA with thermal magnetic release - 01 Nos.
(iv) MCCB 100 Amp 4 Pole ,50 Hz,415 Volts, 25 KA with thermal magnetic release - 01 Nos
1
-
-
... More
(c) Platform of Panel :- Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. Note :-
(i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer.
-
-
-
... More
All as per Item No 10 here-in-before but comprising of the following :-
(a) Incoming :-
(i) MCCB 4 pole , 315 Amps,50 Hz,415 Volts, 36 KA, with thermal and magnetic release - 01 Nos
(ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No (iii) Ammeter digital type with 4 way rotary selector switch-01No (iv) CTs ratio 315/5 A ,class 1, ISI marked -01 sets of three (v) Indicating lamp- 01 set of three
(vi) Aluminium bus bar of rating 630 Amp- set of four (b) Outgoing :- (i) MCCB 200 Amp 4 Pole ,50 Hz,415 Volts, 25 KA with thermal magnetic release - 01 Nos. (ii) MCCB 100 Amp 4 Pole ,50 Hz,415 Volts, 25 KA with thermal magnetic release - 02 Nos. (iii) MCCB 63 Amp 4 Pole ,50 Hz,415 Volts, 16 KA with thermal magnetic release - 02 Nos. (iii) MCB TPN 4 Pole, 63 Amp - 02 Nos (c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. Note :-
(i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer.
1
-
-
... More
S&F in replacement KIOSK box weather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amps and 15 Amps fuse grip with base including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed by Engineer- in- Charge.
25
-
-
... More
Supply, drawing, connecting & testing in replacement of 3 core, 2.5 Sqmm PVC insulated and PVC rounded sheathed, copper conductor (flexible) industrial cable 1100 Volts gradde conforming to IS-694 in steel tubular pole from KIOSK box to light fittings including providing suitable copper lugs complete all as specified and directed by Engineer- in- Charge.
200
-
-
... More
S&F of time switches astro type in having longitude and latitude of Indian cities in memory 415 V three phase 20 Amp rating with 20 Amps, 415 Volts, three pole contactor fitted inside factory made 2mm thick steel enclosure duly powder coated paint complete all as specified and directed by Engineer- in- Charge.
2
-
-
... More
S&F of LED Flood light 200W including all fixing accessories complete all as specified and directed by Engineer- in- Charge. Make:- Surya Cat No. SLF FL 200W IP 65 Lumos or equivalent in Philips/GE
25
-
-
... More
S&F of LED Flood light 120W including all fixing accessories complete all as specified and directed by Engineer- in- Charge. Make:- Surya Cat No. IP 65 Lumos or equivalent in Philips/GE
25
-
-
... More
S&F of LED Flood light 100W including all fixing accessories complete all as specified and directed by Engineer- in- Charge. Make:- Surya Cat No. IP 65 Lumos or equivalent in Philips/GE
25
-
-
... More
S&F of outdoor stand mounted feeder pillar 32 A TPN MCB incomer,single dial time switch, 25A TP contactor for the automatic switching of luminaries, power tool control with 2 Nos 9A contractors and raise lower push button, incoming 35 Sqmm and outgoing 16 & 2.5 Sqmm terminals (type STD4) complete all as specified and directed by Engineer- in- Charge.
3
-
-
... More
S&F of 4 mm dia MS wire 150 mm x 100 mm mesh, made upto into mattress or cages appx 1.5 mtr height and fixed with flate iron/angle by welding in position and directed including complete all as specified and directed by Engineer- in- Charge. Note:- MS angle /MS flate will be measured and paid separately.
24
-
-
... More
M&L for two coats of synthetic enamel paint of silver colour on steel surfaces over a coat of red oxide primer including preparation of surfaces complete all as specified and directed by Engineer- in- Charge.
24
-
-
... More
M&L for cement concrete type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) for sub floors, sub-bases, floors, foundation and paving etc complete all as specified and directed by Engineer- in- Charge.
1
-
-
... More
M&L for MS work of angles for post and struts of fencing around transformer plinth etc drilling holes, flate iron fillet for securing wire mess by welding to angle iron frame and framed work as in door/ gate of angle and wire mess. Door to be fixed by 03 Nos 100mm long hinges and one sliding door bolt of 300mm long for locking arrangement complete all as specified and directed by Engineer- in- Charge.
1
-
-
... More
M&L for demolition of path /concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer- in- Charge.
1
-
-
... More
M & L for boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of GI pipe 50 to 100 mm bore and making good both ends complete all as specified and directed by Engineer- in- Charge.
60
-
-
... More
M & L for earthing complete with galvanised steel earth plate electrode 60cm×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion and complete all as specified and directed by Engineer- in- Charge and shown in electrical plate number 3 of MES SSR part-I (1991).
5
-
-
... More
M&L for plate Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth strip 25 x 4 mm by means of bolts and nuts checknuts and washers of galvanized iron electric arc welding all joints all as specified and shown in electrical plate No 3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia light grade for protection of earth electrode 20 mm dia for watering complete all as specified and directed by Engineer- in- Charge and tested on completion.
5
-
-
... More
M&L for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminium paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed by Engineer- in- Charge.
300
-
-
... More
M&L for re-painting of LT Panels/feeder pillars of approx size 2 to 4 Sqm with 2 coats of super enamal paint over a coat of red-oxide with sparygun including writing of feeder pillar numbers in appropriate size of letters complete all as specified and directed by Engineer- in- Charge.
12
-
-
... More
M & L for painting of transformer installed on plinth/4/6 pole structures at various site of capacity upto 250 KVA with existing colour, with spraying machine, after cleaning, preparation of outer surface of transformer, including writing of SM No, MES and capacity of transformer complete all as specified and directed by Engineer- in- Charge.
2
-
-
... More
M & L for painting of transformer installed on plinth/4/6 pole structures at various site of capacity 315 to 630 KVA with existing colour, with spraying machine, after cleaning, preparation of outer surface of transformer, including writing of SM No, MES and capacity of transformer complete all as specified and directed by Engineer- in- Charge.
5
-
-
... More
S & F in replacement MCCB 4 pole, 63 Amps, 16 KA , 50 Hz, 415 Volts complete all as specified and directed by Engineer- in- Charge.
2
-
-
... More
S & F in replacement MCCB 4 pole, 100 Amps, 16 KA, 50 Hz, 415 Volts complete all as specified and directed by Engineer- in- Charge.
2
-
-
... More
S & F in replacement MCCB 4 Pole ,125 Amps 16 KA complete all as specified and directed by Engr-in-Charge.
3
-
-
... More
S & F in replacement MCCB 4 Pole ,160 Amps 25 KA complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
S & F in replacement MCCB 4 Pole ,200Amps 36 KA complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
S & F in replacement MCCB 4 Pole ,250Amps 36 KA complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
S & F in replacement MCCB 4 Pole ,400Amps 36 KA complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
S & F in replacement MCCB 4 Pole ,630Amps 50 KA complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
S & F in renewal on load change over switch open execution of capacity 400 Amps , 4 pole , 415 volt , 50 Hz fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable change over from panels etc complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
All as per item No 39 above but 250 Amps 4 pole complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
All as per item No 39 above but 200 Amps 4 pole complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
S & F in replacement of LED Street light fittings of capacity 60 Watt complete all as specified and directed by Engr-in-Charge.
45
-
-
... More
S & F in replacement of LED Street light fittings of capacity 70 Watt complete all as specified and directed by Engr-in-Charge.
30
-
-
... More
S & F in replacement of LED Street light fittings of capacity 90 Watt complete all as specified and directed by Engr-in-Charge.
25
-
-
... More
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed by Engr-in-Charge.
Note: (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs.
(c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
6
-
-
... More
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 Volt LT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed by Engr-in-Charge.
Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs.
(c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
6
-
-
... More
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as specified and directed by Engr-in-Charge for the following sizes :-
-
-
-
... More
25-50 Sqmm x 3.5 core/ 4 core
8
-
-
... More
70-120 Sqmm x 3.5 core
6
-
-
... More
185-240 Sqmm x 3.5 Core
3
-
-
... More
S & F of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
-
-
-
... More
70-120 Sqmm 3 core.
4
-
-
... More
150-225 Sqmm to 185 Sqmm, 3 core.
4
-
-
... More
S & F of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
-
-
-
... More
70-120 Sqmm 3 core.
4
-
-
... More
150-225 Sqmm to 185 Sqmm, 3 core.
4
-
-
... More
S & F of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
-
-
-
... More
95 Sqmm 3 core.
2
-
-
... More
120-185 Sqmm, 3 core.
4
-
-
... More
Note : Contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge.
-
-
-