Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Jan 2025
Closing Date4 Feb 2025
Tender Amount₹ 15,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for sand cushioning with a layer of sand Jamuna 23 cm thick (8 cm under and 15 cm above the cable) in trenches complete all as specified and as directed.

6.5

-

-

... More
M&L for fixing old serviciable un-reinforced precast concrete cable covers for cable protection of class LV type 1 flat of size 250 x150 x 40 mm complete all as specified and as directed.

600

-

-

... More
Supply and fixing in repair, Silica Gel Breather assembly including vent pipe and 1Kg Silica Gel for outdoor transformers, capacity upto 630 KVA to 1000 KVA complete all as specified and as directed.

3

-

-

... More
Material & Labour for painting of transformer installed on plinth structures at SALARIA of capacity upto 630/1000 KVA with existing colour, with spraying machine, after cleaning, preparation of outer surface of transformer, including writing of SM No, MES and capacity of transformer complete all as specified and as directed.

3

-

-

... More
S & F XLPE cable end termination, Heat shrinkable, outdoor type complete with jointing material and accessories suitable for voltage 11 Kv (Earthed), 3 core, 240 sqmm complete all as specified and as directed.

4

-

-

... More
S & F XLPE cable end termination, Heat shrinkable, outdoor type complete with jointing material and accessories suitable for voltage 11 Kv (Earthed), 3 core, 95 sqmm complete all as specified and as directed.

4

-

-

... More
Dehydration/filtration of transformer oil by means centrifuging machine electrically operated at site of installation of transformer in running condition including testing of transformer oil before and after filtration by means of oil testing machine, keeping the electrodes at 2.5 mm gap and to achieve die electric strength of filtered oil 50 KV and above complete all as specified and as directed.

1900

-

-

... More
Supply and topping up/replaced transformer oil conforming to IS : 335 and withstand dielectric strength of 60 KV (when tested with 2.5 Gap electrode) complete all as specified and as directed.

150

-

-

... More
Supplying, laying and commissioning of HT XLPE cables, insulated, screened, PVC bedded, galvanized steel strip armoured, earthed, electric power cable with Aluminium conductor, 11 KV grade, 3 Core, 240 Sq.mm cross sectional area laid in trenches / fixed on poles including taking up/down old cables complete all as specified and as directed. Note: Earth work,excavation,cable covers and sand cushioning shall be measured and paid separately.

50

-

-

... More
Supplying, laying and commissioning of HT XLPE cables, insulated, screened, PVC bedded, galvanized steel strip armoured, earthed, electric power cable with Aluminium conductor, 11 KV grade, 3 Core, 95 Sq.mm cross sectional area laid in trenches / fixed on poles including taking up/down old cables complete all as specified and as directed. Note: Earth work,excavation,cable covers and sand cushioning shall be measured and paid separately.

80

-

-

... More
M & L for Stainless Steel Incandescent Flex Glow Signage Board made in square shape body material stailless steel with incandencent lighting as per required dimentions dully fixed at Substation and pump house building at salaria Printing Description and size as per direction of Engr in Charge complete all as specified and directed.

32

-

-

... More
Material and labour for Preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner, applying two coats of synthetic enamel paint by spray machine on all sides of 11 KV VCB panel/RMU including writing of MES /SM No and details of feeder as directed by Engr-in-charge on graphic plastic sheet complete all as specified and as directed.

6

-

-

... More
M & L for Locating electrical faults and repair work in HT-LT side of the transformer, VCB whenever any fault arises at Salaria officers Enclave area, making complete supply system functional dully rectifying and repair work complete all as specified and directed. Note: (a) Whenever any breakdown reported the Contractor will have to take immeadiate action and send skilled Technecian immediately on site. (b) Any parts required to be replaced during repair work shall be measured and paid for separately.

4

-

-

... More
S & F in repair of High voltage insulation mats (ISI Marked) as per IS-15652 of size 02m X 01 m complete all as specified and directed.

5

-

-

... More
Supply and fixing cable route indicator for HT UG Cable of 11000 Volts bolted with 40 x 6 mm flat iron member of height 0.60 mtr, and 80 mm dia CI plate embedded in PCC 1 : 3 : 6 type C2 of size 20 x 20 x 30 cm block complete all as specified and directed.

40

-

-

... More
Periodical servicing to 11KV HT RMU (3 ways) any type make- Crompton Greaves model Sabre complete including the following:- (a) Disconnecting the 11 KV line from RMU. (c) Opening the RMU and replacmenet the unserviceable part as required at site. (b) Checking of mechanical system for proper functioning of upward/downward or clock wise and anty clock wise movement of breaker. (d) Cleaning & servicing the fixed/ moving contact, busbar,cable boots with the CTC solution and greasing/oiling the parts where requied or as directed. (e) Tighting the all loose parts and testing complete as directed by EIC. (f) Repair the door/lock incl welding and painting and replacement of lock/handle Note- (i) Replacing new items shall be included in the quoted rates. (ii) Other part which is not included but requierd for functioning of equipment is included in the quoated rate. (iii) Remove the moisture from RMU by heating (iv) The above job to be carried out by engineer of authorised dealer/service centre of concerned manufacturer. (vii) Painting with the approved coloure after preperationg of old surface as directed.

3

-

-

... More
Maintenance,Servicing,cleaning,Vaccum circuit breaker unit 11KV of capacity 630A, make CG,racking out from panel / opening of the VCB for servicing / overhauling, taking out and removing unserviceable/defective parts including cleaning & servicing ,greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling / servicing and Calibration and testing of 11KV VCBs indoor type along with control panel and control wiring,protection system and Calibration of relays by injecting high voltage/ current in primary / secondary side as required for check the triping mechanism complete including rectification of defects noticed complete all as specified and directed.

3

-

-

... More
S&F in replacement of CT 11KV suitable for VCB Panel Indoor type 12 KV 630 amp,350 MVA(incoming) , 11 KV HT VCB make CG complete all as specified and as directed.

1

-

-

... More
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregates as in foundation of, PCC blocks etc including necessary form work complete all as specified and as directed.

1.25

-

-

... More
Supply & Fixing LT panel LED indication lamp for breaker ON/OFF/TRIP/Breaker Spring Charged/R-Y-B-W etc for 440V LT control panel/APFC Panels and associated wiring, if reqd, including taking down old UNSV LED indication complete all as specified and directed

60

-

-

... More
Supply and installation Anti-condensation space-heater withThermostatic control in cable and circuit breaker compartments of HT switchgears/VCB including taking down old UNSV heater complete all as specified and directed.

2

-

-

... More
Supply & Fixing of fixed contact block complete suitable for VCB Panel Indoor type 12 KV 630 amp,350 MVA(incoming) , 11 KV HT VCB including taking down old UNSV fixed contact block complete all as specified and directed.

3

-

-

... More
Supply & Fixing of Moving contact block complete suitable for VCB Panel Indoor type 12 KV 630 amp,350 MVA(incoming) , 11 KV HT VCB including taking down old UNSV Moving contact block complete all as specified and directed.

3

-

-

... More
Supply & Fixing of Digital Amp meter (CT secondary site selectable 5A) for 11 KV VCB Control Panel including taking down old UNSV meter complete all as specified and directed.

1

-

-

... More
Supply & Fixing of Digital Volt meter Secondary voltage 110 V for 11 KV VCB Control Panel including taking down old UNSV meter complete all as specified and directed.

1

-

-

... More
Supplying and fixing Potential Transformers, in existing VCB Panel Indoor type 12 KV 630 amp,350 MVA(incoming) PT 11KV/110 Dc 24 Volt Ct ratio 200/5 Amp with necessary busbar and connected items dully fixing amd made functional the VCB including taking down old UNSV PTs complete all as specified and directed

1

-

-

... More
M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to earth strip 25x4 mm means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 5 connected to earthing test point earth plate surrounding use of charcoal dust and salt in layer including excavation and earth work , GI pipe 20 mm dia light grade for watering with wire mess and funnel and GI pipe 15 mm dia medium grade for protection of earth lead complete upto main TPN DB making of PCC earth pit using 1:2:4 type B1 using 20mm dia stone aggregate provision of MS PIT cover 300mm x300mm with handle complete all as specified or indicated including testing on completion all as directed.

8

-

-

... More
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to pole or any other indicated situation using GI strip 25 x 4 mm as earthing lead complete all as directed including taking down the old unserviceable complete all as specified and as directed.

50

-

-

... More
S & F danger notice plate of size 25x20cm & 1.6mm thick, mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamp, bolts and nuts of approved size for HT, complete all as specified and as directed.

10

-

-

... More
Supply & Fixing of Digital/electronic Amp meter up to 630 Amp suitable for upto 440V Control Panel dully fixing in existiing LT Panel with necessary arrangement/Hylum Sheet as required including taking down old UNSV meter complete all as specified and directed.

10

-

-

... More
Supply & Fixing of Digital/electronic Volt meter suitable for upto 440V Control Panel dully fixing in existiing LT Panel with necessary arrangement/Hylum Sheet as required including taking down old UNSV meter complete all as specified and directed.

10

-

-

... More
Preparation of old painted surface removing of rust from any kind of steel surface, clamps, TFR fencing etc for of any description and repainting by 1st quality Synthetic enamelled paint 1 coat over a coat of primer complete all as specified and directed

192

-

-

... More
M & L Cleaning /servicing of LT distribution Panel , after Checking the incoming and outgoing connections from MCCB/ Bus bar and replacing the old burnt/ overheated unserviceable lugs, terminals, nuts, bolts, washers supporting insulators etc and checking the serviceability of MCB / MCCB, earth continuity conductor and strip etc complete all as specified. Dully blowing out all unwated dust etc with high pressure air blower and painting complete Panel with existing colour after cleaning at Substation Salaria and Transformer Destribuition Panel complete all as specified and directed.

4

-

-

... More
M & L Cleaning /servicing of APFC Panel , after Checking the incoming and outgoing connections from MCCB/ Bus bar and replacing the old burnt/ overheated unserviceable lugs, terminals, nuts, bolts, washers supporting insulators etc and checking the serviceability of Capacitor Bank/ APFC relay/ CTs etc and making functional all ammeater and voltmeter, earth continuity conductor and strip etc complete all as specified and painting complete Panel with existing colour after cleaning complete all as specified and directed and repai/replacement of following parts:-

3

-

-

... More
M&L for Replacement for LT APFC panel CTs as per existing ratios including taking out old Us CTs complete all as specified and directed.

6

-

-

... More
M&L for Replacement of Capacitor bank for capacitor panel of capacity 50 KVAR complete including taking out old u/s one complete all as directed .

4

-

-

... More
M&L for Replacement of Capacitor bank for capacitor panel of capacity 25 KVAR complete including taking out old u/s one complete all as directed .

2

-

-

... More
M&L for Replacement of Capacitor bank for capacitor panel of capacity 15 KVAR complete including taking out old u/s one complete all as directed .

2

-

-

... More
M&L for Replacement of Capacitor bank for capacitor panel of capacity 10 KVAR complete including taking out old u/s one complete all as directed .

2

-

-

... More
M & L for Power Factor Controller suitable for measuring auxillary supply voltage of 110 to 550 VAC user interface with a menu-driven display ,8-12 switching outputs,Programable individual banks kvar value Complete menu-guided operation and display Illuminated graphic display with 2 x 16 characters Display of various line parameters (V, I, F, Q, P, S) as per existing make Rudra Shakti SC-102 complete all as specified and directed.

3

-

-

... More
M & L for construction of fire point having a platform as per standard design/ size and height, constructed in brick work in 1:4 cement mortar, and rendering 15mm thick on brick masonry surfaces in 1:4, plain cement concrete flooring with PCC as per zonal specifications, including roof covering in hut shape with 0.80mm thick plain galvanised iron sheet with angle iron 50x50x6mm and flat iron 40x60mm, fire point shall be painted in red colour synthetic enamel paint after preparation of surfaces having "FIRE POINT" word on top of roof covering in white colour synthetic enamel paint, complete all as specified. Note: Cost of following equipments/ accessories shall also be deemed inclusive in quoted rate: (a) 02 Nos. of fire extinguishers, discharge Carbon-di-oxide type, having 140Kg/Sqcm working pressure, ISI marked 6.50 Kg capacity with hose pipe, conforming to IS-2873, complete in all respect to working in any emergency situation and working temperature upto +60 degree centigrade. (b) Fire bucket duly paint in red colour and filling with fine sand dully hanged in hook all as specified- 04 Nos. (c) Fire beater duly painted in red colour- 02 Nos. (d) Shovel with long handle duly painted in red colour- 02 Nos. (e) Fire hook duly painted in red colour- 02 Nos.

1

-

-

... More
S & F in repair selector switch for Volt meter up to 500 Volt , 3 pahse RYB selector switch dully repalced in existing LT Panel Complete all as specified and directed.

10

-

-

... More
S & F in repair selector switch for Amp meter up to 400 Amp , 3 pahse RYB selector switch dully repalced in existing LT Panel Complete all as specified and directed.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.