If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date7 Dec 2024
Closing Soon28 Dec 2024
Tender Amount₹ 50,00,000 
Notes
Download

Costs

Summary

Ge/c-84/2024-25 Repair/ Replacement Of Sewage Line, Cleaning Of Manhole, Septic Tank Including Repair To External Drain, Fencing, Boudary Wall, Hardstanding And Parking Shed At Brar Square, 1wec, 61 Cav, Karan Vihar, Uri Enclave And 48 Mvh Under Ge

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cleaning of Manhole depth exc 1.2 mtr and above of any size of MH in the area of ZONE A (Md accn and all types of Accn) omplete all as specified and as directed.

200

-

-

... More
Cleaning of Sewage line from GT to Ist Manhole in the area of ZONE A (Md accn and all types of Accn) complete all as specified and as directed. Note-cleaning of sewage line daimeter upto 100mm to300mm.

70

-

-

... More
Cleaning of sewage line n.exc 15mtr length in the area of ZONE A (Md accn and all types of Accn). complete all as specified and as directed. Note-cleaning of sewage line daimeter upto 100mm to 300mm.

600

-

-

... More
Cleaning of Sewage line 0.00mtr to 30.00mtr and onwards in length in the area of ZONE A (Md accn and all types of Accn) complete all as directed and as specified. (Note :- This item will be measured if length exceed from 30.00mtr.and cleaning of sewage line daimeter upto 100mm to 300mm. Note :- For execution of item from Srl No. 1 to 7 above Agency should deploy minimum of 03 Nos Safaiwala and 01 Nos Supervisors on all days of the month/year during the contract period including Sunday and Holidays so as to complaints are attended promptly within 02 hours so that health and life of troops and their families is not adversly affected.

20

-

-

... More
M&L for 15mm thick rendering on fair face of brick wall surface in CM 1:4 smooth finishes as specified and as directed.

1052

-

-

... More
Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in soft/loose soil complete all as specified.

220

-

-

... More
M&L for 150mm sail-glazed stoneware drain pipes laid in trenches and jointed mplete all as specified and as directed.

150

-

-

... More
Supply and laying, DWCPE(SN8) 200 mm dia pipes and snap fit coupler incl testing and laid properly, jointed laid in teenches to a level on concrete bed complete all as specified.

250

-

-

... More
M&L for Sand cushion under floors or in foundation including watering and consolidation.

23

-

-

... More
M&L for cement concrete 1 : 4 : 8, type D2, using 40mm graded stone aggregates incl beding, packing under and haunching against the sides for 200mm internal dia of pipes, after they are laid and tested complete all as specified (thickness of concrete bed 100mm).

150

-

-

... More
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified.

150

-

-

... More
Removal of surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above starting point.

60

-

-

... More
M & L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 all as specified.

15

-

-

... More
S & F in replacemen precast fibre reinforced cement concrete Manhole cover including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 450mmx450mmx50mm omplete all as specified and as directed.

100

-

-

... More
S & F in replacemen precast fibre reinforced cement concrete Manhole/drain cover including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 1000mmx500mm x50 mm omplete all as specified and as directed.

200

-

-

... More
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section) in cement concrete 1 : 2 : 4 type B1 using 20mm graded stone aggregate finished smooth and reforming benching as required for 150mm dia pipes complete all as specified.

2

-

-

... More
Dewatering/ desludging of septic tanks, soakage wells etc of any depth, cleaning of all sludge, silt residue of both organic and inorganic nature by manual labour or by mechanical scrappers etc and disposal off the same out side the defence area all as specified and directed by Engr-in-Charge.

150

-

-

... More
Mechanically used water fitting Hydraulic pressure machine and water sucking hydraulic pressure machine jet press for cleaning of sewage line shall be used by the contractor as per direction of Engineer-in-Charge as on required basis. Job shall be completed to the entire satisfaction of GE. (For Zone - A.)

5

-

-

... More
M&L for cement concrete 1:3:6 type C-1, using 12.5 mm graded stone aggregate as in coping and similar work incl necessary form work to obtain a smooth finishes complete all as specified and as directed.

4.7

-

-

... More
M&L PCC 1:4:8 type D2 using 40mm graded stone aggregates as in foundation complete all as specified and as directed.

15.6

-

-

... More
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) Complete all as specified and directed by Engineer-in-Charge.

450

-

-

... More
S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors.

200

-

-

... More
S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears 75 mm bore complete.

100

-

-

... More
S & F PVC bends 110 mm size diminishing pieces or tapers (larger bore measured) with oval access door all as specified

20

-

-

... More
S & F PVC bends 75 mm size diminishing pieces or tapers (larger bore measured) with oval access door all as specified.

10

-

-

... More
Supply and fix in replacement of broken cast iron (sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, laid in trenches including excavation and PCC bedding and haunching in below ground level or in floors or fixed to walls with clamps etc, bore of pipe 75mm complete all as specified and directed.

50

-

-

... More
Supply and fix in replacement of broken cast iron (sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, laid in trenches including excavation and PCC bedding and haunching in below ground level or in floors or fixed to walls with clamps etc, bore of pipe 100mm complete all as specified and directed.

100

-

-

... More
S&F in repair 100 mm bore cast iron bends complete all as specified and as directed.

10

-

-

... More
S&F in repair 75 mm bore cast iron bends complete all as specified and as directed.

10

-

-

... More
S&F 12 mm thick polycarbonate twinwall clear sheet flexible, strong impact and shutterproof all weather outdoor covering fixed to existing steel frame/ truss including all necessary fixing screws /nuts and safety measures and scaffolding complete all as specified and directed engineer-in-charge.

445.2

-

-

... More
Dismantling of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed.

185.5

-

-

... More
M&L for Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or oloured cement to match incl 15mm thick screed bed or bedding layers in cement mortar ( 1:6) Complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
M&L for glazed ceremic colour tiles (600x300x7mm) thick, in vertical surface etc set and jointed in neat slurry and pointed in white or coloured cement to match with tiles including 10mm thick rendering in cement mortar (1:6) Complete all as specified and directed by Engineer-in-Charge.

80

-

-

... More
M&L for Non - skid Ceramiccolour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or oloured cement to match incl 15mm thick screed bed or bedding layers in cement mortar ( 1:6) Complete all as specified and directed by Engineer-in-Charge.

60

-

-

... More
S&F Non - skid Ceramic colour tiles 600 x600 x 7 to 8 mm thick in floors etc and 15mm thick screed bed 1:6 in cement mortar. set and jointed in neat cement slurry and pointed in white or coloured cement to match Complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
S&F Non - skid Ceramic colour tiles 600 x100 x 7 to 8 mm thick in vertical surfaces etc and 10mm thick screed bed 1:4 in cement mortar. set and jointed in neat cement slurry and pointed in white or coloured cement to matchComplete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
Demolition of concrete and pavings n.exc 15 cm thickness (below or above ground level).

21.28

-

-

... More
M&L for cement concrete 40mm thick type B-1, 1:2:4 (using 20 mm graded aggregate) as in floor for fair finished surfaces of concrete complete all as specified and directed.

150

-

-

... More
M&L for cement concrete 75mm thicktype C-2 1:3:6 (40mm graded aggregate)as in plinth protection and paths laid in alternative panel.

70

-

-

... More
Material and labour for rotational moulded polyethylene water storage tanks white colour 500 lts capacity, triplr layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia brass float valve and polyethylene ball including taking out existing unserviceable overhead tank of any description.

12

-

-

... More
Material and labour for rotational moulded polyethylene water storage tanks white colour 1000 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia brass float valve and polyethylene ball including taking out existing unserviceable overhead tank of any description.

10

-

-

... More
S&F 20 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed.

20

-

-

... More
S&F flot valves 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms complete all as specified and directed.

40

-

-

... More
Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 15mm complete all as specified and directed.

100

-

-

... More
Supply and fix galvanized steel tubing, 15 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed.

100

-

-

... More
Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 20mm complete all as specified and directed.

50

-

-

... More
Supply and fix galvanized steel tubing, 20 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed.

50

-

-

... More
Demolition of brick work or stone masonry built in cement mortar in any position including segregating serviceable/unserviceable bricks/stones Complete all as specified and directed by Engineer-in-Charge.

28.98

-

-

... More
M&L for Brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 Complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
All as per sr No 52 above but except bricks.

8.98

-

-

... More
Taking down cement plaster of any description on brick or stone wall incl raking out joints, hacking for key, scurbing down with water etc Complete all as specified and directed by Engineer-in-Charge.

700

-

-

... More
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over primer complete all as specifed as direted by Engr-in-charge.

252

-

-

... More
M&L for precast cement concrete 1:2:4 type B-0 (using 12.5mm stone graded agg) as in louversand jallies 40mm thick designed as fort pattern (measured solid) including all moulding but exceeding frame and set in CM1:4 incl dismantling of existing all as per sample shown and directed by engineer-in -charge.

42

-

-

... More
M&L providing CM 1:3:6 Type C-0 12.5 mm graded agg. In precast coppings incl slightly rounded chemered angles and throating including necessary form work complete.

0.35

-

-

... More
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors or fixed on walls 110mm dia fixed in repairs Complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
M&L for machine pressed precast concrete interlocking paver block 60mm thick M-35 grade any shape and size with grey cement and pigment Complete all as specified and directed by Engineer-in-Charge.

920

-

-

... More
M&L 15 mm thick screed bed or bedding layer for laying floor finishes of tiles CM 1:6 Complete all as specified and directed by Engineer-in-Charge.

550

-

-

... More
S&F Chequered cement concrete PU coated colourtiles 300cm X 300cm x 25mm thick set, jointed and pointed in neat cement slurry in floors with grey cement and pigments Complete all as specified and directed by Engineer-in-Charge.

550

-

-

... More
Dismantling/ demolition posts or struts embedded in soil or concrete etc (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground Complete all as specified and directed by Engineer-in-Charge.

150

-

-

... More
Dismantling fencing wiremesh, any type Complete all as specified and directed by Engineer-in-Charge.

270

-

-

... More
Excavation in post holes (or similar holes) n exc 0.5 cum getting out in any type of soil returning filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25cm and covering and removal of surplus soil n exc 50m and making good surface Complete all as specified and directed by Engineer-in-Charge.

45

-

-

... More
M&L for cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) in foundations, filling and mass concrete Complete all as specified and directed by Engineer-in-Charge.

4.1

-

-

... More
S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wiremesh etc) including all necessary drilling, bolting or riveting, etc including embeding in concrete and similar work conforming to Fe-290 Gde-E-165 Complete all as specified and directed by Engineer-in-Charge.

1183.05

-

-

... More
S&F high quality zinc coated GI Chain link fencing of required width in mesh size 50x50 mm made of GI wire dia not less than 3mm and fix with column with nut or bolts and strengtheing with 10mm TMT bars, conforing to standard grade steel complete all as specified and directed. NOTE:- (i) Payment of TMT bar shall be made in seperate items in this Schedule. (ii) The Engr-in-Charge along with rep of contractor shall verify the weight mesh and submit the copy along with photographic eveidence along with RAR and Purchase Voucher. (iii) The quoted rate shall be inclusive of Nut bolt required.

1026

-

-

... More
S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Complete all as specified and directed by Engineer-in-Charge.

277.65

-

-

... More
S&F in repair galvanized 2 strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacing and straning and fixing to fencing post with staple or steel pins etc Complete all as specified and directed by Engineer-in-Charge.

9

-

-

... More
Dismantling of wrought iron or mild steel work of any description Complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S & F for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates and framework for tank stagging and simillar items also fastening and fixing complete all as specified and directed by enginer-in -charge.

1000

-

-

... More
M&L for preparation of new or previously untreated steel surfaces over 10cm in width or girth and applying two coats of syanthetic anamel paint over one coat of red oxide Complete all as specified and directed by Engineer-in-Charge.

110

-

-

... More
Material and labour for medium duty perforated precast machine pressed drain cover slab 170 mm thick of PCC 1:1.5:3 type B-1 and 10mm TMT bars including flat iron 75mmx6mm all around the slab and 40mm dia hole at 100mm C/C , size of slab as required at site and complete all as specified and directed.

150

-

-

... More
Dismentling plain or corrugated steel sheeting any gauge thickness including nainital or similar pattern roof covering Complete all as specified and directed by Engineer-in-Charge.

640

-

-

... More
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws Complete all as specified and directed by Engineer-in-Charge.

640

-

-

... More
S&F in repairs 15mm bore GI fitting such a union, socket, Tee, Elbow, Nipple 4" 6", Reducer, Plug, and tank nipple complete all as specified and directed.

200

-

-

... More
S&F in repairs 20mm bore GI fittings such a union, socket, Tee, Elbow, Nipple 4" 6", Reducer, Plug, and tank nipple complete all as specified and directed.

138

-

-

... More
Schedule of Credit

-

-

-151085



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.