Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 79,200Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Special Repair/replacement Of Sub Main Wiring And Light Fittings/fixtures In Edpw At Afcao At Camero Complex, Provision Of Security Grill For Various Offices Of Afro And Sncos Mess Treasure Office At Subroto Park And Provn Of Acs And Chemical Earthi
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_676741_1Bid Award Id
ViewTender No
GE/SP/TOKEN-07/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Schedule of credit, schedule A Notes, Special conditions, Particular specifications and other connected documents
BOQ Items
M&L for preparation of newly plastered or unplastered surface and applying two coats of distemper oil emulsion on walls over a coat of primer incl 3mm thick wall care putty on walls complete all as specified and directed by Engr-In-Charge.
50
-
-
M&L for prepration of old plastered or unplastered surfaces of walls and applying two coat of approved shade of oil emulsion distemper with 3mm thick elastomeric wall care putty on walls, including repairing of pot holes and cracks with putty, take it plaster where it required complete all as specified and directed by Engr-in-Charge.
390
-
-
M&L preparation of new plastered or unplastered surface and applying three coats of white wash on ceiling upto four stories complete and all as specified and directed by engr-in -charge.
50
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.complete all as specified and directed by Engr In Charge.
370
-
-
M&L Glazed ceramic coloured tiles in vertical surface 300mm x 450mm x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl back plaster 10 mm thick in cm 1:4 & including 100mm thik cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base for floors finishes complete all as specified and directed by Engr In Charge.
100
-
-
M&L Virified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with neat cement slurry over 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor complete all as specified and as directed by Engr-In-Charge.
250
-
-
All as per Item No 9 here in before but as on vertical surface of wall such as skirting/dado including 10mm thick cement plaster (1:4) as in backing coat of tiles
20
-
-
M &L for PVC profile for wall panelling colour / shade as approved size 250mm wide, 08 mm over all thickness fixed with screw to mild steel square ( size 20mmx 20mmx 1mm thick) tubler frame work including one coat of red oxide primer, fixed to walls and including dismentling complete all as specified and directed by Engr-in-Charge.
258
-
-
M&L for PVC profile corner beading L/T type for wall panelling, colour/shade matching with wall panelling complete all as specified and as directed
381.34
-
-
Material and labour for false ceilings using GI snap grid system with roll-formed out of hot dip galvanised steel caping (powder coated) main runner 38 x 24 mm , cross Tee 29 x 24 mm and wall angle 24 x 24 mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceiling board , pre painted Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions size 595 x 595mmx 4mm thick any texture (Lake and Hill, oceaniccascade or Electra) as approved by GE all as per , Everest Ceiling grid system 'Regular T-2430' or its equivalent make of "'Ramco/ Charminar/Armstrong'' at any height including dismantling complete all as specified and as directed by Engr-In-Charge.
380
-
-
S & F aluminium deco grills conforming to DG-104 grade complete all as specified and directed by Engineer-in-Charge.
150
-
-
S & F for aluminium power coated frame work any colour (minimum thickness of power coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleats for fixing etc complete all as specified and directed.
290
-
-
S & F for aluminium power coated any colour (minimum thickness of power coating 50 micron) aluminium window and ventilator shutters, sliding type, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
50
-
-
S&F powder coated aluminium door shutters, (minimum thickness of powder coating 50 micron) aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, powder coated aluminum snap beading screws etc. complete all as specified and directed.
27.76
-
-
S&F 5.5mm thick plain glass ordinary quality and glazing, suare exc 0.50 sqm in each pane as in doors etc. Complete all as specified and directed.
40
-
-
S& F 9mm thick prelaminated particle board, interior grade, prelaminated on both sides with decorative choice lamination complete all as specified and directed.
30.45
-
-
S & F in repair aluminium extruded section door closer hydraulically operated designation No-03, universal type, suitable for door shutters of 851 to 1000mm width and of weight of 61 to 80 Kg complete all as specified and directed.
20
-
-
S&F for Brass Mortice lock, vertical type, size 100mm, 4 Levers complete all as specified and directed.
20
-
-
Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power) complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
516
-
-
M&L for point wiring with single core FRLS PVC insulated sheathed IS-694 marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through and including conduit of size of not less than 20mm including all acessories concealed wiring on wall and surface on ceiling terminated in and including ms sunken box covered with3 mm thick laminated top sheet cover along with provn of earth wire PVC insulated, unseathed, 1100 V grade cable multi stranded FRLS IS - 694 markd copper conductor of size 1.5 sqmm all as specified and directed by Engr-in-Charge. (Note : Cost of for cutting chaising and making good to disturbed surface all as to match with existing surface are deemed to be included in quoted rate.) of the following One light point controlled by one switch one way.
100
-
-
All as per item No 23 here in before but One C/ fan/Exhaust fan/wall fan point controlled by one switch one way.
22
-
-
All as per item No 23 here in before but for one 3 pin 5 amps socket outlet on independent board.
95
-
-
All as per item No 23 here in before but for one 3 pin 5 amps socket outlet on the same board with other switchs.
28
-
-
All as per item No 23 here in before but for One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq.mm size
6
-
-
All as per item No 23 here in before but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including single core 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire.
265
-
-
Supply and fix MCB DB single pole and neutral with two pin and earth plug and socket 20 Amps compete with one SP MCB 20 Amps fixed flush in wall including cutting chases in wall for fixing DB and making good the disturbed wall surface to match with existing specification.
22
-
-
S & F Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
251
-
-
S & F Modular Socket, 6A - 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
123
-
-
S&F Modular switch 1 way 16A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
265
-
-
S & F Modular Socket, 16A - 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
265
-
-
Supply and fix White cover plate with frame,3 module Complete all as specified and directed by Engineer-in-Charge.
95
-
-
Supply and fix White cover plate with frame,4 module Complete all as specified and directed by Engineer-in-Charge.
265
-
-
Supply and fix White cover plate with frame,6 module Complete all as specified and directed by Engineer-in-Charge.
16
-
-
Supply and fix White cover plate with frame,8 module Complete all as specified and directed by Engineer-in-Charge.
16
-
-
Supply and fix modular metal flux box, 3 module Complete all as specified and directed by Engineer-in-Charge.
95
-
-
Supply and fix modular metal flux box, 4 module Complete all as specified and directed by Engineer-in-Charge.
265
-
-
Supply and fix modular metal flux box, 6 module Complete all as specified and directed by Engineer-in-Charge.
16
-
-
Supply and fix modular metal flux box, 8 module Complete all as specified and directed by Engineer-in-Charge.
16
-
-
Supply and fix Modular Bell push 6A 1 module Complete all as specified and directed by Engineer-in-Charge.
6
-
-
Supply and fixing ceiling roses, surface bakelite 65x50mm ,3 terminals 3 phase, PVC/Polycarbonate, isolated body complete all as specified and directed.
22
-
-
Taking down LED Light of any size Complete all as specified and directed by Engineer-in-Charge.
100
-
-
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
85
-
-
Supply and fixing LED lights fitting 1x 20W 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
15
-
-
Taking down wall mounting fan of any size dismantling blades and removing fan and blades to and deposit to MES store after making serviceable and refixing the same position Complete all as specified and directed by Engineer-in-Charge.
22
-
-
M & L in repair for submain wiring with two run of single core 10.0 sqmm PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 10.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified and directed. Note : 3 Runs of 10.0 Sqmm single core PVC insulated unsheated FRLS cable and one run of 20 mm dia PVC conduit shall be measured as one unit for payment purpose.
290
-
-
M & L in repair for submain wiring with two run of single core 6.0 sqmm PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified and directed. Note : 3 Runs of 6.0 Sqmm single core PVC insulated unsheated FRLS cable and one run of 20mm dia PVC conduit shall be measured as one unit for payment purpose.
320
-
-
M & L in repair for submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified and direcetd. Note : 3 Runs of 4.0 Sqmm single core PVC insulated unsheated FRLS cable and one run of 20mm dia PVC conduit shall be measured as one unit for payment purpose.
415
-
-
Supply and fixing load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 250 Amps rated bus bar and stove enamels dust and vermin proof suitable for FP 'A' frame MCCB of 250 Amps =01 No and MCB for outgoing complete all as specified and as directed by Engineer-in-Charge.
3
-
-
Supply and fix in replacement of fixed thermal and fixed magnetic settings, 4 pole MCCB 100 Amps, 50 HZ, 415 volts with rupturing capacity 36 KA complete all as specified and directed by Engineer-in-charge.
3
-
-
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 4 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
8
-
-
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
15
-
-
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN12 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
8
-
-
Supply and fixing 415V 10KA 'C' curve TPN 16 To 32 AMP miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
31
-
-
Taking down unserviceable SP/SPN MCBs of any capacities from the MCCB DBs /MCB DBs after disconnecting the electric supply,complete all as specified and directed.
217
-
-
S&F MCB SP 5 to 32 Amps 10 KA, 240 volt 'C' Series complete all as specified and directed by engineer-in-charge.
186
-
-
S&F MCB SPN 40 Amps 10 KA, 240 volt 50 Hz 'C' Series complete all as specified and directed by engineer-in-charge.
31
-
-
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip 4 mm dia as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner complete all as specified and directed. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
3
-
-
M&L in replacement of earth contuinity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanized iron or steel wire complete all as specified and directed by Engineer-in-Charge.
75
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and as directed by Engineer-in-Charge.
110
-
-
Excavation in trenches in hard and dense soil n exc 1.5 mtr wide and n.exc 1.5 mtr in depth for laying of pipe,foundation for poles, stay, laying cables etc and getting out complete all as specified and directed by engineer-in-charge.
32.17
-
-
Returning filling in including spreading, leveling watering and well ramming in layers n. exc 25 cm in hard/dense soil complete all as specified and directed by engineer-in-charge.
19.37
-
-
Removing excavated material n.exc 50 meters and depositing where directed at a level n.exc 1.5 meter above the starting point complete all as specified and directed by engineer-in-charge.
12.8
-
-
M&L for Sand cushioning of cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable complete all as specified and directed by engineer-in-charge.
8.91
-
-
Supply and laying well burnt sub class ‘B’ bricks old size as mechanical protection to under ground cables laying across the cable complete all as specified and directed by engineer-in-charge.
0.96
-
-
Supply, fabrication, installation testing and commissioning of indoor wall mounted control panel box not less than 2 mm thick made out of modular polycarbonate thermoplastic enclosure, CPRI approved, enviroment friendly, recyclabe, UV resistant halogen & silicon free, anti-acid & anti corrosive, IP-65 protection in accordance with IEC 60529. The gasket material shall be polyurethane while gasket shall be internally embedded including suitable suitable working space in bus bar chamber suitable for 3 phase, 4 wire system 415 volt 50Hsz AC supply. The cable connection with suitable size of lugs/thimbles etc including suitable size of canopy to cover the panel with proper fixing arrangement and other work following comprising:-
Incoming:-
(i) MCCB 250 Amps, four pole , 36 KA adjustable type 50 Hz, 415 volt
(ii) Digital type volt meter with selector switch - 01 set
(iii) Digitaltype Ammeter with selector switch - 01 set
(iii) CT -3 Nos
(iv) LED type indicator lamp set of red, yellow and blue - 01 set
(v) 2/32 A control fuse base with link - 06 Nos
Outgoing:-
(i) MCCB 100 Amps four pole , 36 KA adjustable type 50 Hz, 415 volt- 02 Nos
(ii) MCB 63 Amps , four pole. 10Ka - 2 Nos (iii) MCB 40 Amps , four pole. 10Ka - 2 Nos
1
-
-
Supply and fixing MS cable tray Mild steel of size 300MM x 50MM perforated cable tray for industrai use of size 3MM thicker rectangular with polished finishing and galvonaised coating with all connecting accessories requied at site with proper fixing/finishing completed all as specified and as directed by Engineer-in-Charge. .
60
-
-
Supply and install hi wall split units digital invertor type indoor/outdoor copper tube evaporator and condencing unit with capacity of 1.5 Ton complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 Ton fitted on wall and out door to be fixing on roof/wall at requirement place including all necessary elecrical connections, bolting , nuts , clamping of 3 core copper cable, cooling tube , drain water pipe etc up to 3 mtr complete all as specified and directed by Engineer -in -Charge.
5
-
-
M&L cross arms bracings suppots clamps and back plates fabricated from structural steel sections including nuts bolts washers welding bending cold or hold drilled holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under and one finished coat of paint for installation of condencing unit on the wall / ground complete all as specified and as directed by Engineer-in-charge
5
-
-
S&F flexible threaded pvc pipe for drain of water of size 15mm from indoor unit to exist point as per design including accessories clamps fastners complete all as specified and as directed by Engineer-in-charge
30
-
-
M&L for laying of copper tubing of dia 1/2" including insulation and brazing work complete all as specified and as directed by Engineer-in-charge.
15
-
-
M&L for laying of copper tubing of dia 1/4" including insulation and brazing work complete all as specified and as directed by Engineer-in-charge.
15
-
-
Supply, & Fixing of 3 core flexible copper cable of size 2.5 Sq mm 1100 V grade complete fixing on wall by clamping/securing including connections complete all as specified and as directed by Engineer-in-charge.
25
-
-
M &L for chemical earthing with Conductive Concrete Earth Grid of 1,with multiple interconnected Earth Electrodes(at least 7 Nos equipment interconnected) with Installation in Rocky soil along with soil treatment & Testing to achieve the value of 3 Ω Specifications
(i) Earth Electrodes: Metal conductor - Cu bonded MS rod size : Dia 17.2 mm (+/-0.5mm ), Length 3 m with conductive concrete embedding size: Dia 85-100 mm, Length 3 m of each earth electrode.
(ii) Soil Treatment: All earth electrodes would be installed in specially treated pits. Pits of L 1.5m x W 1.5m x D3 m each shall be prepared by taking out the rocks/high resistivity soil. Then it shall be filled with fresh low resistivity sieved soil and compacted with water. Soil would be specially treated to bring down the resistivity around the pits drastically and these treatment chemicals would be absolutely non corrosive, highly conductive and would not need water for electrical conductivity.
(iii) Interconnected Strip : All the multiple Earth Electrodes will be horizontally interconnected with metal conductor - Cu bonded MS flat size : 25mm x 5 mm & conductive concrete embedding size : 75 mm².
(iv) Test Link : Test links - Cu bonded MS flat size : 50 mm x 6 mm x 200 mm shall be provided,
(v) Pit Cover : RCC pit cover & frame shall be provided at two Earth Electrode ( with test links). Rest of the Earth Electrode shall be buried in soil complete all as specified and directed.
1
-
-
M&L for Earth continuity copper conductor or main earthing lead of size 20mmx3mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc.complete all as specified and directed by Engineer-in-charge.
250
-
-
Supply and Installation Cross arms, bracings ,supports, clamps and back plates fabricated from structural steel sections including nuts ,bolts,washers,welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by engr in charge.
360
-
-
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
6
-
-
Supply and fixing industrial Triple pole and earth encolsure with a three pin and earth plug with socket complete all as specified and directed.
12
-
-
Supply and fixing 240V,30mA Residual current circuit breaker with overcurrent (RCBO) of double poles and current carrying capacity 16 AMP, in the MCB DB with connection testing and commissioning complete all as specified and directed.
12
-
-
M & L for submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified and direcetd. Note : 3 Runs of 4.0 Sqmm single core PVC insulated unsheated FRLS cable and one run of 20mm dia PVC conduit shall be measured as one unit for payment purpose.
267
-
-
Evaluation Notes How It Works ?
Potential Partner