Military Engineer Services Tender
... More
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_MES_346458_1Bid Award Id
ViewTender No
GE ELECT/D-25/2020-2021Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Repair and maintenance of LT cable HT cable LT Poles and electrical breakdown incl fault detectin localisation and rectification in HT LT undergbround network at DK I II Shooting Range and Nodel Pump house I and adjoining area in the area of AGE U El
Repair and maintenance of LT cable HT cable LT Poles and electrical breakdown incl fault detectin localisation and rectification in HT LT undergbround network at DK I II Shooting Range and Nodel Pump house I and adjoining area in the area of AGE U El
Repair and maintenance of LT cable HT cable LT Poles and electrical breakdown incl fault detectin localisation and rectification in HT LT undergbround network at DK I II Shooting Range and Nodel Pump house I and adjoining area in the area of AGE U El
BOQ Items
... More
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.
304
-
-
... More
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
25000
-
-
... More
Laying only old serviceable bricks obtained from excavation complete all as directed.
5000
-
-
... More
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm.
1800
-
-
... More
Laying only old serviciable HT cable cover obtained from excavation complete all as directed.
1000
-
-
... More
Supply, laying, jointing, testing and commissioning in replacment LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, ISI marked, laid in trenches complete all as specified and directed. Cables of the following sizes:-
Note :- Excavation, earth work ,cable protection , sand fillings & cable joint shall be measured and paid separately.
-
-
-
... More
16 Sqmm 4 core
500
-
-
... More
25 Sqmm 4 core
300
-
-
... More
35 Sq mm 3.5 core.
500
-
-
... More
50 Sq mm 3.5 core.
550
-
-
... More
70 Sqmm 3.5 core
200
-
-
... More
95 Sqmm 3.5 core
100
-
-
... More
120 Sqmm 3.5 core
300
-
-
... More
185 Sqmm 3.5 core
1000
-
-
... More
240 Sqmm 3.5 core
800
-
-
... More
300 Sqmm 3.5 core
20
-
-
... More
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed of following sizes
Note :- Excavation, earth work ,cable protection , sand fillings & cable joint shall be measured and paid separately.
-
-
-
... More
95 sqmm 3 core.
50
-
-
... More
120 sqmm 3 core.
100
-
-
... More
185 sqmm 3 core
100
-
-
... More
300 sqmm 3 core
100
-
-
... More
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed.
Note: (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs.
(c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
30
-
-
... More
All as per item Ser No 11 above but 1100 Volt LT cables
40
-
-
... More
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs.
(c) Excavation and earth work will be measured and paid seperately under respective items of schedule.
400
-
-
... More
Material and labour disconnecting faulty /burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work , suitable size of thimble LT tap , relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals for 25 Sqmm 3.5/4 core to 240 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as directed.
80
-
-
... More
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as directed for the following sizes :-
-
-
-
... More
25-50 Sqmm x 3.5 core/ 4 core
30
-
-
... More
70-150 Sqmm x 3.5 core
30
-
-
... More
185 -300 Sqmm x 3.5 core
20
-
-
... More
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
-
-
-
... More
120 Sqmm to 185 Sqmm, 3 core.
7
-
-
... More
240 Sqmm to 300 Sqmm 3 core
5
-
-
... More
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
-
-
-
... More
95 Sqmm 3 core.
5
-
-
... More
120 Sqmm to 185 Sqmm, 3 core.
7
-
-
... More
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
-
-
-
... More
95 Sqmm 3 core.
5
-
-
... More
120 Sqmm to 185 Sqmm, 3 core.
12
-
-
... More
240 Sqmm to 300 Sqmm 3 core
10
-
-
... More
S&F KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amps and 15 Amps fuse grip with base including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed.
100
-
-
... More
Taking down unservicable RCC/ steel tubular poles of any type and supply & installing steel tubular swaged poles type 410 SP-31 (09 mtr long) of apprx wt. 147 kg with suitable mountoing arm of 1.5 inch GI pipe outer dia, 1 meter over hang, incluiding exacavation, earth work, PCC foundation, base plate,PCC coping,GI pipe for cable protection etc. complete all as per manufacturer's instructions and as specified and as directed by E-in-charge.
NOTE:- The unit rate in this item is deemed to be included the cost oif exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI pipe medium grade 40 mm bore, 2x1 mtr long for streetlight cable protection. The steel pole shall be painted by bituminious paint total lenth inside and up to planting depth outside
18
-
-
... More
S&F in renewal of 3 pole contactor of ,mounted on any type LT Panel/Feeder Pillar/Wall after taking down old existing unserviceable.of size ML-6
3
-
-
... More
Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 3.5 m below normal ground level) with top edge of earth plate not less than 2.5m below normal ground level, connected to galvanized lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 5 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed.
Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 15 mm bore GI pipe medium grade etc.
(b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
20
-
-
... More
Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 3.5 m below normal ground level) with top edge of earth plate not less than 2.5m below normal ground level, connected to galvanized iron strip 32X6 mm by means of electric arc welding of galvanised iron or steel as shown in electrical plate No 5 of SSR Part I, connected to earth test point and the equipment on the other side complete all as specified, including testing and commissioning complete all as directed.
Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40mm bore GI pipe medium grade etc.
(b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI earthing and protection pipe upto 7.5 meter beyond the earth plates electrode.
39
-
-
... More
M&L for re-painting of LT Panels/feeder pillars of any sizes of 2 coats of super enamal paint over a coat of red-oxide with sparygun including writing of feeder pillar numbers in appropriate size of letters as directed.
20
-
-
... More
M&L for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminium paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed.
246
-
-