If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date14 Jun 2024
Closing Date4 Jul 2024
Tender Amount₹ 28,19,293 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking up or down steel tubing and connections of 20 mm bore dia of pipe including cleaning for refixing or removal from site complete all as specified and directed.

90

-

-

... More
Refixing old steel tubing and connections of 20 mm bore dia in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed.

20

-

-

... More
S&F 20 mm bore dia of medium grade galvanised steel tubing with all fittings and fixed complete to wall or laid in floor complete in all respect complete all as specified and directed.

70

-

-

... More
Taking up or down steel tubing and connections of 25 mm bore dia of pipe including cleaning for refixing or removal from site complete all as specified and directed.

90

-

-

... More
Refixing old steel tubing and connections of 25 mm bore dia in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed.

20

-

-

... More
S&F 25 mm bore dia of medium grade galvanised steel tubing with all fittings and fixed complete to wall or laid in floor complete in all respect complete all as specified and directed.

70

-

-

... More
Dismantling water tanks exc 250 ltr and n.exc 500 ltr and removal from site complete all as specified and directed.

24

-

-

... More
S & F Rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 1000 Ltrs Including making connection for inlet & outlet with connection pipes complete all as specified and directed.

24

-

-

... More
S & F in repair ball brass valves high pressure with polythene float & flynut complete screwed for Iron pipe or brass ferrule of 20 mm dia and fixed complete all as specified and directed.

24

-

-

... More
S&F in repair 20 mm bore gun matel globe or gate valves with iron wheel, screwed both ends for iron pipes complete all as specified and directed.

24

-

-

... More
Taking down cement plaster on brick walls, raking out joints locking for key, scrubbing down with water etc complete all as specified and directed.

180

-

-

... More
M&L for 15 mm thick cement plaster in CM (1:4) on fair face of brick or concrete surfaces of walls finished even and smooth without using extra cement (incl new brick work) complete all as specified and directed.

130

-

-

... More
M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 marble powder : 2 marble chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the marble chippings complete all as specified and directed. Note: Payment for providing grooves shall be made seperately Note :- Only steel scaffolding is allowed and rate included in above item. The work shall be carried out by enclosing affected area by green cloth) up to G+3 storey building and deploy skilled labourers to execute the work

90

-

-

... More
M&L for forming groove of uniform size 15 mm wide and 15 mm deep in top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under laying including removal of wooden battens, repair to the edges of panels and finishing the grooves all round as per approved pattern. The groove shall be finished with two coats of bitumenous paint complete all as specified and directed.

60

-

-

... More
M & L for applying 1.50 mm (average thickness) wall care putty on walls to bring the surface even smooth complete all as specified and directed.

130

-

-

... More
M & L for Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.

130

-

-

... More
S&F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, colour as approved by engr in charge complete all as specified and directed.

80

-

-

... More
S&F Plates chequered (Fe-410 -W(Gde E-250) quality-B) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment including all required assesseries complete all as specified and directed.

2300

-

-

... More
S&F Stairs (framed) Fe-410 -W(Gde E-250) quality-B including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. complete all as specified and directed.

1200

-

-

... More
S&F Fe-410- W(Gde- E-250) quality- B Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc incl welding of expanded metal with flat bar to the angle complete all as specified and directed. Note: payment of expanded metal is to be done in seperate item

8000

-

-

... More
Supply only Expanded metal of required size and shape of mesh, weight n exc 4 kg/sqm (incl cutting, bending and weld with MS angle and flat) complete all as specified and directed.

250

-

-

... More
S&F Steel work in tubular tru-sses of required shape including special shaped washer etc, complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240, complete all as specified and directed.

600

-

-

... More
M&L for preparation of new or previously untreated surfaces, of steel and iron work of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of Red oxide primer complete all as specified and directed.

100

-

-

... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.

4

-

-

... More
Dismantling of Plain or corrugated steel sheeting, any type of sheet, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.

50

-

-

... More
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of approved colour, size 65x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing company complete all as specified and directed. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Make : Rajshri / Fenesta / Ecocell

160

-

-

... More
Providing and fixing at site Factory Made 24 mm thick 100% Solid WPC (Wood polymer Composite ) Plain Jali cut on CNC machine of approved design & measured size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural Fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with density not less than 650 kg/cbm manufactured by an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive Strength of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof, Fire Retardant and fixing with stainless Steel butt full body threaded star headed counter sunk SS Screws. All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company complete all as specified and directed. Make : Rajshri / Fenesta / Ecocell

100

-

-

... More
Dismantling loose concrete cover of RCC columns, beams, slabs, chajjas, parapets, railing and the like as directed without disturbing the core of RCC member, roughening and cleaning concrete surfaces with steel wire brushes, washed with and allowed to dry, including application of rust removal cum passivator painted with brush to the rusted reinforcement (and removing rust with flex after 24hours of application of rust remover with the help of wire brush, sand paper) and also applying zinc anti-rust agent as per manufactures method of application to re bar corrosion protection system to reinforcement surface of steel reinforcement with existing reinforcement as directed wherever required binding RCC 100mmx100mm (10 gauge welded mesh) & tack welding after that applying polymer modified cementious bonding coat, prepared and applied on the concrete surface with 1 part of sika latex or equivalent in Forsoc/BASF/Dr Sunanda with 4 part of water and 6 part of cement by weight, coverage of sika latex shall not be more than 0.25 Kg/Sqm for one coat. Adhesive bond strength not less that 2.5 mpa, After this, providing 40mm (average thickness) guiniting mix @ pressure 2.2 to 2.5 kg per sqcm with anti corrosion admixture (using 1 part of ordinary potland cement 43 grade and 2 part of Ghagger sand mixed with adhesive /admixture at the rate as per manufacturer instruction and as directed) including stripping floting with wooden strippers for proper dimension control necessary, formwork and scaffolding, complete surface of guiniting to be finished fair with 10mm thick plaster in cement 1:4 with water proofing compound @ 3% by weight of cement cleaning and removing of waste material etc as directed at site complete all as specified and directed. Note: Welded mesh & addl reinforcement if required measured and paid separetly) Note : Only steel scaffolding is allowed and rate included in above item. The work shall be carried out by enclosing affected area by green cloth) up to G+3 storey building.

50

-

-

... More
M & L for hard drawn steel wire fabric cut to length, bent to shape required of mild steel wire mesh / welded mesh and tying with and including annealed mild steel wire not less than 0.9mm dia binding wire S & F in reinforcement weight not exceeding 4.00 Kg/Sqm complete all as specified and directed

100

-

-

... More
Note : The work described in item Nos from 1 to 32 shall be executed in bldgs up to (G+3 floor) hence the contractor shall make scaffolding arrangements (only steel scaffolding is allowed), trestles, ladders etc and hessian clothes for protection & all other safety precautions up to 04 storeys of buildings and the cost for the same is deemed to be included in the quoted unit rates. Note :- Removing building materials /debris / old waste unwanted existing material of any description or any type etc. to a distance of 5km or beyond out side MOD Land. Note :- Arrangement of any required machinery / tools required for removing debris from terrace to ground and then remove to outside MOD land, will be made by the contractor and the cost for the same is deemed to be included in the quoted unit rates. Safety measures for workers to be ensure by the contractor. Note :- Before commencement of work, The contractor will ensure that water supply from water tanks to the respective quarters should not interrup during execution of work, For the same the cost for any required fitting / accessories is deemed to be included in the quoted unit rates.

-

-

-

... More
Dismantlling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.

355

-

-

... More
M & L for Vitrified coloured double charged tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed by Engr in charge

145

-

-

... More
All as per item no 34 above but as in skirting/dado on 10mm thick rendering in cement mortar 1:3 complete all as specified and directed.

10

-

-

... More
M&L for joint free glazed ceramic coloured tiles in vertical surface 350 x 250 x 7 mm or 450 x 350 x 7 mm thick with matching highlighter over and including 10 mm thick rendering in cement mortar 1:4 set and jointed in neat cement slurry and pointed in white or colour cement to match coloured tiles (Design/colour of tiles will be approved by GE) complete all as specified and directed.

100

-

-

... More
M & L for Machine cut Pre polished kota stone slab/tiles flooring 20-25mm thick in any size over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and incl 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.

95

-

-

... More
M & L for Kota stone Pre polished kota stone slab/tiles 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed over and incl 10mm thick screed bed in cement mortar 1:4 complete all as specified and directed.

5

-

-

... More
M&L for 15mm thick rendering on fair or other than fair faces of brick work or concrete surfaces in cement mortar 1:6 finished complete all as specified and directed.

50

-

-

... More
Dismantling wall and ceiling boards of any description as in panelling any thickness, including cover fillets in any surface complete all as specified and directed.

325

-

-

... More
M&L for powder coated GI T Grid system in 600 x 600 mm module which includes providing and fixing wall angle along the perimeter of the room with nylon sleeves and wooden screws at 300 mm centre to center. Suspendeding the main tee of size from the soffit, soffit cleat, rawl plugs and wire rod & leveling spring clip at 1200mm center to center cross tee, interlockined into the pre-cut slots in the main tees at 600 mm centre to center in direction perpendicular to the main tee to make a grid of 600x 1200mm. 600 mm cross tees are interlocked in the pre cut slots in the 1200mm tees at 1200 mm center to center in direction parallel to the main tee. Cross Tees having length more than 600 mm are to be supported independently. 4.5 mm thick E board or perforated type with square Edge of size 595x595 mm be placed in the grid of 600x600mm. Size of grid as speicfied by Manufacturers complete all as specified and directed.

125

-

-

... More
M&L Providing PVC SHEET WALL PANELLING of thickness 5mm ( ±0.25 ) consisting of panels of desired size stuck on inner frame work of 50mm wide strips of 5mm ( ±0.25 ) thick Prelam PVC sheet. The panel & strips shall be Density of 600 Kg /Cum Manufactured by an ISO-9001-2015 certified Company. The strips should have in their center a grove of 6mm width and 1mm depth for sinking the head of the screw used to fix the strips to the wall vertically at an equal interval of 10” between two PVC strips. The PVC strips shall be fixed to the wall using 65mm long M.S. screws through the groove in the strip by using PVC fasteners. The distance between two screws shall not be more than 200mm. A groove of 2mm may be left at the joint of two panels for aesthetic looks. The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall. Optionally a strips of 5mm ( ±0.25 ) thick PVC sheet of width 75mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cement complete all as specified and directed.

200

-

-

... More
M&L for PVC 'L' angles fixed at where direction changed portion with adhessive or as per manufacture instruction complete all as specified and directed.

80

-

-

... More
Taking down chowkhats or frame with shutters without taking off shutters from frames of size exc 1.5 Sqm but not exc 4.00 sqm each & removing form site incl making good disturbed portion complete all as specified and directed.

2

-

-

... More
Taking down chowkhats or frame with shutters without taking off shutters from frames of size n. exc 1.5 Sqm each & removing form site incl making good disturbed portion complete all as specified and directed.

3

-

-

... More
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.

35

-

-

... More
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing not less than 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150mm long - 01 Nos, hinges type B-21 100mm long - 02 Nos, suitable handle - 01 Nos etc in each shutter complete all as specified and directed.

4.5

-

-

... More
S&F for Sheet glass 5.50mm thick ordinary quality and glazing with oil putty/glazing clips in square exc 0.5 sqm in each pane complete all as specified and directed.

3.5

-

-

... More
S&F Powder coated aluminium ornamental grill 10 mm dia, 75 X 95 mm aperture fixed in powder coated aluminium snap beading complete all as specified and directed.

4.5

-

-

... More
M&L for 12mm thick toughned glass door end seal and fixed with stainless steel floor springs, 2nos of stainless steel handle 600mm long fancy type in each shutter fixed to glass door, heatching/flim of approved design on the glass complete all as specified and directed. Note: Floor spring and handles measured and paid separately)

5.1

-

-

... More
Supply only 32 mm dia 600 mm long handle suitable for glass door complete all as specified and directed.

2

-

-

... More
Supply only Stainless steel body and internal machanism heavy duty concealed floor spring suitable for 12mm thick glass door 1.1 mtr span fixed on tiles or granite surface complete all as specified and directed

2

-

-

... More
Supply and fix stainless steel body centre locking arragement suitable for glass door complete all as specified and directed.

2

-

-

... More
E&M PORTION: Taking down carefully old point wiring with aluminium/ copper conductor (Light / Fan/ Socket/ power Point ) complete including fittings such as ceiling rose, pendent holders, regulators and socket point etc and making good the disturbed surface & wall/ floor complete all as specified and directed.

201

-

-

... More
M&L for point wiring with PVC insulated unsheathed multi stranded FRLS type copper conductor cable of size 1.5 Sqmm 1100 V grade including one run of PVC insulated unsheathed multi stranded FRLS type copper conductor cable of size 1.5 sqmm as earth continuity conductor connected to common earth dolly in and including PVC concealed conduit 20 mm dia medium grade ISI marked and its accessories including provn of new factory made pressed steel modular switch/terminal box of suitable size and new modular front & back plates of approved colour/model of suitable size for housing the modular switches, sockets, fan regulators complete all as specified and directed for the following:- Note: Cutting chases for concealed conduit and making good in cement mortar is deemed included in unit rate.

-

-

-

... More
One light/fan/exhaust point controlled by one no, one way 5 Amp switch complete all as specified and directed.

47

-

-

... More
One three pin 6 Amp socket outlet point controlled by one no, one way switch on same board complete all as specified and directed.

4

-

-

... More
One three pin 6 Amp socket outlet point controlled by one no, one way switch on independent board complete all as specified and directed.

130

-

-

... More
All as per item No. 55 here in before but with 2.5 sqmm (for phase, neutral) and 2.5 sqmm (for continuous earth wire) cable for one 15/16 amp socket out let point on independent board complete all as specified and directed.

20

-

-

... More
S&F in repair modular switch 6 Amp, SP, one way,one module, 230 volts AC complete all as specified and directed.

181

-

-

... More
S&F in repair modular switch 16 Amp, SP, one way, one module, 230 volts AC complete all as specified and directed.

20

-

-

... More
S&F in repair modular Socket, 6A - 2/3 pin combined 2 module 230 volts AC complete all as specified and directed.

134

-

-

... More
S&F in repair modular Socket 6A/16A - 2/3 pin combined 2 module,, 230 volts AC complete all as specified and directed.

20

-

-

... More
S&F in repair of ceiling rose 3 terminal / PVC/ Polycarbonate, insulated body ISI Marked complete all as specified and directed.

6

-

-

... More
S&F in replacement of PVC plastic MCB protected socket 20 Amps with MCB SP upto 16 Amps 230 volts AC and plug top 16 Amps complete all as specified and directed.

6

-

-

... More
Supply & fixing in repair remote control BLDC Ceiling fan complete with blades,down rods and all connected accessories operating at 230 V with 1200/1400 mm sweep. ,rated 5 star with brushless direct curent (BLDC) motor,color as per site requirement.Making arrangement for hanging fans to ceiling with proper hook,nut,bolt with twin core twisted flexible copper conductor complete all as specified and directed by Engineer-In-Charge. Make:- Havells/Orient/crompton Note:-The old U/S 1200/1400mm sweep ceiling fan to be deposited to MES store yard in safe custody.

14

-

-

... More
S&F in repair submain wiring with PVC insulated unsheathed copper conductor multi stranded FRLS type 1100V grade 2 x 4 sqmm complete drawn in new PVC concealed conduit and its accessories along with 1x 4 sqmm PVC insulated unsheathed copper conductor multi stranded FRLS type cable for continuous earth wire and duly connected to common earth dolly complete all as specified and directed. Make:-RR/Polycab/Havells Note:-Three wire of 4 Sqmm and one run of pvc conduit/casing caping shall be measured as one unit.

90

-

-

... More
S&F in repair submain wiring with PVC insulated unsheathed copper conductor multi stranded FRLS type 1100V grade 2 x 10 sqmm complete drawn in new PVC concealed conduit and its accessories along with 1x 10 sqmm PVC insulated unsheathed copper conductor multi stranded FRLS type cable for continuous earth wire and duly connected to common earth dolly complete all as specified and directed. Make:-RR/Polycab/Havells Note:-Three wire of 10 Sqmm and one run of pvc conduit/casing caping shall be measured as one unit.

60

-

-

... More
S&F in repair LED Tube Light of 20/22 Watt 230Volt (size 4 ft) , box type complete with LED Tube Light 20 Watt & all accessories internally prewired including connecting up with three core sheathed flexible copper conductor cable of suitable size complete all as specified and directed. Make: Havells / CG/Philips

4

-

-

... More
S&F in repair LED Tube light fitting 10 watt ( 2 ft ) white 230 Volt AC complete including connecting up with three core twisted flexible copper conductorr cable complete all as specified and directed. Make Havells / CG/Philips

2

-

-

... More
S&F in replacement recess mounted 2x2 LED luminaire 36 watt which provide soft light and glare free symmentrical illumination fixed in ceilling complete all as specified and directed.

27

-

-

... More
S&F in repair factory made sheet steel distribution boards, double door, SPN 12 way, concealed type, 240 volts AC with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing complete all as specified and directed.

8

-

-

... More
Supply and fixing in repair MCB, 240V 10KA, B curve of following poles and current carrying capacity in the MCB DB with connection testing complete all as specified and directed for the following capacity:-

-

-

-

... More
MCB SP 5 to 32 Amps

80

-

-

... More
MCB SP 40 Amps

8

-

-

... More
MCB SPN 32 Amps

8

-

-

... More
M & L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25x4 mm up to 7.50 RM bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board / test point (including test point) at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh etc including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil including taking down old unsv earthing complete all as specified and directed.

2

-

-

... More
M&L in replacment earth continuity conductor or main earthing lead fixed to wall on batten or reccess or chases or burid in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing as required 25x4 mm galvanised iron strip complete all as specified and directed.

30

-

-

... More
S&F in repair factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 4 way VTPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete all as specified and directed.

2

-

-

... More
S&F in repair of MCCB 4 pole 63 Amp, 415 Volts ,16kA fixed type including thimbles, nuts, bolts ,washers etc. and connections complete all as specified and directed.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.