Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 Nov 2024
Closing Date17 Dec 2024
Tender Amount₹ 23,00,000
Costs
EMD
₹ 46,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_685571_1Tender No
GE/TKD-66/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
All as per item no 03 but size 25 sq mm to 50 Sqmm, 3.5/4 core complete all as specified and as directed by the Engr-in-Charge.
3
-
-
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide in not exceeding 1.5mtr in depth for foundation etc or for shaft well, cesspits, manholes, fire hole etc n.exc 10sqmm on plan and not exceeding 1.5mtr in depth and getting out complete all as specified and as directed by the Engr-in-Charge.
78
-
-
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed by the Engr-in-Charge.
26
-
-
Removing excavated material not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and as directed by the Engr-in-Charge.
51
-
-
M&L for sand cushioning in trenches for protection of LT underground cable including watering and consolidation complete all as specified and as directed by the Engr-in-Charge.
36
-
-
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete all as specified and as directed by the Engr-in-Charge.
1670
-
-
M&L in replacement of cable XLPE insulated screened PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes complete all as specified and as directed by the Engr-in-Charge.
-
-
-
150 sqmm 3.5 core
50
-
-
120 sqmm 3.5 core
100
-
-
95 sqmm 3.5 core
100
-
-
70 sqmm 3.5 core
80
-
-
50 sqmm 3.5 core
100
-
-
10 sqmm 4 core
400
-
-
M&L in replacement of cable XLPE insulated screened PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of following sizes complete all as specified and as directed by the Engr-in-Charge.
-
-
-
240 sqmm core
20
-
-
185 sqmm core
30
-
-
Supply and fix in street light TIMER control panel, pole/wall mounting made out of CRCA sheet duly powder coated with locking arrangement, incl internal wiring complete with bypass arrangements and comprising of following :- (or as manufactures recommendation and design) including taking down old unserviceable timer panel complete :-
(a) Incomer MCB TPN 63 Amps, 240/410V- 01 Nos (b) Digital timer switch - 01 No (c) Contactor AC 3 rating, 3ph, of capacity 65/100 Amps - 01 No
(d) ON/OFF indicating lamp - 01 Set
(e) Auxiliary change over switch 6 A - 01 No
2
-
-
Supplying and laying in replacement of synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, black in colour complete all as specified and as directed by the Engr-in-Charge.
4
-
-
M & L in replacement of PVC flat twin core cable with aluminium conductor of size 10 Sqmm 2 core suitable for 1100 volts power supply complete all as specified and as directed by the Engr-in-Charge.
200
-
-
M & L in replacement of PVC flat twin core cable with copper conductor of size 06 Sqmm 2 core suitable for 1100 volts power supply complete all as specified and as directed by the Engr-in-Charge.
150
-
-
Supply and fixing in replacement copper wire in wiring circuits as per site requirements HRFR-PVC insulated single core 1.5 Sqmm 1100 volts grade multi stranded conductor complete all as specified and as directed by the Engr-in-Charge.
180
-
-
Supply and fixing in replacement copper wire in wiring circuits as per site requirements PVC insulated single core 2.5 Sqmm 1100 volts grade multi stranded conductor complete all as specified and as directed by the Engr-in-Charge.
200
-
-
Taking out by disconnecting/unscrewing all electrical connection of UNSV post top light, M & L including testing of post top of 35 watts capacity suitable for 240 volts, 50 Hz, IP 65 single phase power supply, light, spun aluminium landscape luminaire with high power LEDs as light source complete with all standrard accessories complete all as specified and as directed by the Engr-in-Charge.
15
-
-
Taking out old UNSV landscape light from the existing position and M&L including testing and commissioning of landscape luminaire aluminium cast for diffused lighting with high power LEDs as light source having height 0.5 meter of 25 watts capacity suitable for single phase, 240 volts, 50 Hz, IP 65 power supply complete all as specified and as directed by the Engr-in-Charge. Note- Necessary PCC work and excavation is deemed to be included quoted rates.
6
-
-
Taking out by disconnecting/unscrewing all electrical connection of UNSV flood light and M & L including testing of flood of 60 watts capacity suitable for 240 volts, 50 Hz, IP66 protection, single phase power supply, fabricated with die cast aluminium with high power LEDs as light source complete all as specified and as directed by the Engr-in-Charge.
10
-
-
Taking out by disconnecting/unscrewing all electrical connection of UNSV flood light, S&F of flood of 100 watts capacity suitable for 240 volts, 50 Hz, IP66 protection, single phase power supply, fabricated with die cast aluminium with high power LEDs as light source complete all as specified and as directed by the Engr-in-Charge.
4
-
-
S&F in replacement Energy saving 150 Watt environmental friendly, long life, exclusive innovative die cast aluminium IP66 flood light in LT pole with high power LEDs as light source, suitable for highlighting architectural features complete all as specified and as directed by the Engr-in-Charge.
4
-
-
Taking out by disconnecting/unscrewing all electrical connection of UNSV vertical medium bay light, M & L including testing of vertical medium bay light of 100watts capacity suitable for 240 volts, 50 Hz single phase power supply, fabricated with die cast aluminium with high power LEDs as light source, IP-54 complete with complete all as specified and as directed by the Engr-in-Charge.
2
-
-
Taking out old UNSV bus chamber of any rating and M&L for supply and fixing aluminium bus bar chamber current rating 200 amps 4 way type suitable for 415 Volts, 50 Hz AC supply complete making all incoming and outgoing connections complete all as specified and as directed by the Engr-in-Charge.
1
-
-
Taking out old UNSV Changeover switch of any rating and S&F of aluminium bus bar Off-load changeover switch AC 20 having current rating 400 amps 4 pole, 415V AC, in Sheet metal enclosure and side handle complete all as specified and as directed by the Engr-in-Charge.
1
-
-
Taking out old UNSV Changeover switch of any rating and S&F of aluminium bus bar Off-load changeover switch having current rating 200 amps 4 pole, 415V AC, in Sheet metal enclosure and side handle complete all as specified and as directed by the Engr-in-Charge.
1
-
-
Taking out old UNSV MCB any type and M&L for MCB C series TPN 40-63 amps, 4 pole rating, as per IS 60898-1, 415 volts, 50 Hz, 10 KA, complete all as specified and as directed by the Engr-in-Charge.
10
-
-
Supply and fixing in replacement SPN 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity in the MCB DB complete all as specified and as directed by the Engr-in-Charge.
15
-
-
All as per item No. 27.10 above but MCB 40 to 63 Amp complete all as specified and as directed by the Engr-in-Charge.
14
-
-
Supply and fixing in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB complete all as specified and as directed by the Engr-in-Charge.
15
-
-
All as per item no:28 above but of 40Amps complete all as specified and as directed by the Engr-in-Charge.
12
-
-
M&L for providing cement concrete type D2 (1:2:4) using 40 mm graded stone aggregate in foundation, filling and mass concrete complete including dismantling existing complete all as specified and as directed by the Engr-in-Charge.
1
-
-
S&F in replacement of GI pipe of size 50mm dia, 'light grade', galvanised, with all fitting, laid in trenches for cable crossing through road & path ways, complete all as specified and as directed by the Engr-in-Charge.
15
-
-
S&F in replacement of GI pipe of size 80mm dia, 'light grade', galvanised, with all fitting, laid in trenches for cable crossing through road & path ways, complete all as specified and as directed by the Engr-in-Charge.
10
-
-
M&L for Excavation by Trench less Boaring Technology for holes under road, pavement, hard standing using Ultra sound technique and engaging necessary Machine including HDPE pipe ISI marked of upto dia 100 MM suitable for 0.4 MPA working pressure complete all as specified and as directed by the Engr-in-Charge. Note - HDPE pipe and making good the disturbed surface is deemed to be included in rate quoted by the Contractor.
20
-
-
Taking down /dismantling of old UNSV solar street light from the existing location and M&L for servicing and testing, commissioning of solar street light including replacement of unserviceable component like solar street light lamp having luminaire 15 Wattage, LED type, Maximum power point tracking (MPPT) SCC solar charge controller, Mono Crystalline SPV panel of 30 watts & making them serviceable, complete all as directed by Engr-in-charge.
3
-
-
S&F in replacement of Solar battery, maintenance free, 12V, 65Ah, complete all as specified and as directed by the Engr-in-Charge.
3
-
-
Supply and fix in replacement of looping box duly disconnecting of incoming/outgoing cables & removing from site, installation and testing of non transparent SMC Kiosk box 3 phase with 4 No bus bar, 63 Amps aluminium 4 wire and 1 nos Kit kat fuse of 10 amps factory made out of 14 gauge steel sheet locking arrangement front side of suitable size 300x200x100 mm complete all as specified and directed by Engr-in-charge.
40
-
-
M&L in replacement of Earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to but using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed by the Engr-in-Charge.
6
-
-
S&F in replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mm galvanised iron stripe, complete all as specified and as directed by the Engr-in-Charge.
40
-
-
Supply & Fixing in replacement MCCB 400 Amps 4 Pole breaking capacity 36 kA,415 V, suitable for existing LT panel Adjustable type, conforms to IS/IEC 60947-2 & IEC 60947-2, ICS=100 % of ICU with spreader terminals complete all as specified and as directed by the Engr-in-Charge.
2
-
-
All as above item No: 39, but MCCB of 250Amp, 4 pole, 36 kA complete all as specified and as directed by the Engr-in-Charge.
3
-
-
All as above item No: 39, but MCCB of 200Amp, 4 pole, 36 kA complete all as specified and as directed by the Engr-in-Charge.
3
-
-
All as above item No: 39, but MCCB of 125Amp, 3 pole, 16 kA complete all as specified and as directed by the Engr-in-Charge.
4
-
-
All as above item No: 39, but MCCB of 100Amp, 3 pole, 16 kA complete all as specified and as directed by the Engr-in-Charge.
3
-
-
All as above item No: 39, but MCCB of 63Amp, 3 pole, 16 kA complete all as specified and as directed by the Engr-in-Charge.
4
-
-
Supply and fixing in repair of digital Voltmeter of range 0-500 Volts single phase, Class 01 of size 96 x 96mm suitable for existing LT panel complete all as specified and as directed by the Engr-in-Charge.
20
-
-
Supply and fixing in repair of digital Amp meter with CTs 0-300 Amps single phase, class 01 of size 96 X 96mm suitable for existing LT panel complete all as specified and as directed by the Engr-in-Charge.
20
-
-
S&F in replacement 2'x2' size LED panel lighting luminaire glare free illumination suitable fr false ceiling (armstrong/Grid) fitting size 600x600x70 mm (LXWXH) of 42 watts capacity recess mounting with high brightness SMD LEDs complete incl taking down old UNSV fittings all as directed by Engr-in-charge.
15
-
-
S&F in replacement 1'x1' size LED panel lighting luminaire glare free illumination fitting size 300x300mm (LXWXH) of 15 watts capacity surface mounting with high brightness SMD LEDs complete all as specified and as directed by the Engr-in-Charge.
10
-
-
S&F in replacement LED bulb 12 watt white/warm white in colour and pin/thread type suitable for B22 base complete all as specified and as directed by the Engr-in-Charge.
100
-
-
S&F in replacement of Modular switch 1 way 6A, 1 module , 230 Volt, flush button single pole one way complete all as specified and as directed by the Engr-in-Charge.
45
-
-
S&F in replacement of Socket, 6A - 2/3 pin combined 2 module 230 Volt flush type complete all as specified and as directed by the Engr-in-Charge.
40
-
-
S&F in replacement of Modular switch 1 way 16A, 1 module, 230 Volt, flush button single pole one way complete all as specified and as directed by the Engr-in-Charge.
35
-
-
S&F in replacement of Socket 6A/16A - 2/3 pin combined 2 module 230 Volt flush type complete all as specified and as directed by the Engr-in-Charge.
40
-
-
S&F in replacement of LED lights fitting 1x 20W, 220V, AC retrofit type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by the Engr-in-Charge.
150
-
-
Supply & fixing in replacement of aluminium lugs of short barrel complete all as specified and as directed by the Engr-in-Charge of following size:
-
-
-
Size of 25Sqmm
20
-
-
Size of 35Sqmm
30
-
-
Size of 50Sqmm
40
-
-
Size of 70Sqmm
30
-
-
Size of 95Sqmm
25
-
-
Size of 120Sqmm
20
-
-
Size of 150Sqmm
20
-
-
Size of 185Sqmm
20
-
-
Size of 240Sqmm
30
-
-
M&L for painting to LT steel tubular poles along with cross arms, clamps, channels, bracing etc complete with machine spray after cleaning and preparation the surfaces, externally with two coats of aluminium paint duly making 30 cm width circular bands of 03 Nos alternatively 1 meter from ground level with blue paint making back ground and writing numbering of poles complete all as specified and as directed by the Engr-in-Charge.
40
-
-
M&L for painting of transformer complete with two coats of synthetic enamel paint of approved colour including removing of all loose paints, oils dust, rust etc including painting/marking of SM No/MES No, capacity etc. for 1000 KVA capacity complete all as specified and as directed by the Engr-in-Charge.
1
-
-
M&L for painting of LT Panel complete with two coats of synthetic enamel paint of approved colour including removing of all loose paints, oils dust, rust etc of any size, complete all as specified and as directed by the Engr-in-Charge.
6
-
-
S&F in replacement of brass battery lugs suitable for solar light battery terminal, complete all as specified and as directed by the Engr-in-Charge.
4
-
-
S&F in replacement of bracket made of GI pipe light grade 40mm bore bent to shape as required at site for street light fitting 1.2 m in length and fixed on wall/pole including necessary MS clamps, nuts, bolts etc complete all as specified and as directed by the Engr-in-Charge.
10
-
-
S&F in replacement of MCCB 630 Amps 4 Pole breaking capacity 50kA 415V, ICS=100% of ICU, adjustable type complete all as specified and directed by Engr in charge.
2
-
-
M&L for LT underground cable fault finding for exact location by using LT fault locating equipment and trace out the fault complete all as specified and directed by Engr-in-charge. Note :- The rate quoted by the contractor shall include the rate for excavating the cable at the fault location and pinpoint the fault and repairing the cable using cable jointing kits and by adding extra LT cable if required at site, jointing the cable as before to the panel and testing complete all as earth work and necessary T&P etc.
10
-
-
S&F in replacement of cable route indicator made out of 15x15x6mm GI Plate welded with 8mm x 45cm long GI rod routed in PCC block 1:2:4 type B1 using 20mm graded stone aggregate of size 15x15x10cm and writing the word 'LT Cable' as directed with synthetic enamel paint of two coats over a coats of primer including excavation and earth work complete all as specified and directed by Engr in charge.
15
-
-
Taking out hanging doors from LT panels/DG Sets/HT VCB Panels welding the doors in position by using new hinges and scrapping old surface and cleaning smoothly, removing dust and rust and replace the door closure if required including preparation of surfaces with synthetic enamel grey paint by using spray gun machine and writing capacity and location with black synthetic enamel paint complete all as specified and directed by Engr in charge.
10
-
-
Cutting and removing the vegetation growth and surface dressing, trimming of branches from trees coming on the substation or all around the installation yard including two pole structure area around power house (external only) to keep always installation clean and tidy including white wash at plinth / foundation of transformer if required complete all as specified and as directed by the Engr-in-Charge.
180
-
-
Supply and Fix in replacement of drivers for flood light / high bay lights fix on high mast light/pole/bldg at any height and refixing the same location of 150 watt, complete all as specified and as directed by the Engr-in-Charge.
15
-
-
Supply and Fix in replacement of drivers for flood light / high bay lights fix on high mast light/pole/bldg at any height and refixing the same location of 100 watt, complete all as specified and as directed by the Engr-in-Charge.
12
-
-
Supply and Fix in replacement of drivers for flood light / high bay lights fix on high mast light/pole/bldg at any height and refixing the same location of 50 watt, complete all as specified and as directed by the Engr-in-Charge.
16
-
-
Taking down old UNSV Street/security light driver from pole fitting upto 11 mtr height and S&F new electronic LED driver suitable for fixing in any make 45/60 Watt LED Light Fitting complete all as specified and as directed by the Engr-in-Charge.
15
-
-
Taking down old UNSV Street/security light driver from pole fitting upto 11 mtr height and S&F new electronic LED driver suitable for fixing in any make 70/90 Watt LED Light Fitting complete all as specified and as directed by the Engr-in-Charge.
16
-
-
M&L for servicing of high mast of any height and description, opening the mechanical hoisting/lowering assy, steel wire bobbin replacing the unserviceable meshing gear, easying the steel rope movement checking the locking mechanism, replacing of oil greasing incl tool of LT Panel complete with two coats of synthetic enamel paint of approved colour including removing of all loose paints, oils dust, rust etc of any size, complete all as specified and as directed by the Engr-in-Charge.
2
-
-
M&L in replacement re-winding of the 3 HP AC motor of High mast and taking out to workshop for re-winding, removing the burnt out windings, re-winding the same with super enamelled copper wire of existing gauge, varnishing and oven drying, assembling and testing in position, complete all as specified and directed by Engr in charge.
2
-
-
S&F in replacement of A one 4 Kg ABC powder type Fire Extinguisher with wall mounted complete all as specified and directed by Engr in charge.
11
-
-
S&F in replacement of steel tubular swaged poles complete with cast iron base plate, final taper plug, bolt nut and screws as specified type 410 SP-22, 9 mtr long complete all as specified and directed by Engr in charge.
8
-
-
Supply, installing, testing and commissioning in replacement of factory made and tested LT Panel outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-65) and made of 2.00 mm thick CRCA Sheet & suitable frame work/ support made out of 40 x 40 x 5 mm MS Angle, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete all as specified and directed by Engr in charge. The scope of work also comprising of the following :- BUS BAR CHAMBER :- (a) 630 Amp 3 Strips & Neutral Strip 250 Amp, Aluminium conductor, with color coded heat shrinkable sleeve and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.
1
-
-
INSTRUMENT CHAMBER :- (i) Digital Volt Meter, 96X96mm, flush type rated 0-500V, with Volt meter selector switch- 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-600A, with Amp meter Selector switch- 01 Set. (iii) C.T's 600/5 A CL 1.0 Tape Wound- 01 Set. (Set of three)
(iv) Red, Yellow, Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three).
(v) Protection MCB 6 A SP C Series- 1 Set. (Set of three). INCOMING SUPPLY :- (i) MCCB 400 Amp ,4 Pole 35 KA , 415 V(ICS=ICU=ICW for 1 Sec) ,thermal Magnetic Release OUTGOING SUPPLY :- (i) MCCB 200 Amps 25 KA ,4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=01 Nos.,
(ii) MCCB 125 Amps 25 KA ,4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=02 Nos., (iii) MCCB 125 Amps 25 KA ,4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=03 Nos.,
-
-
-
M&L in replacement of APFC Panel of capacity 180 KVAR consist of sheet metal enclouser of 2mm thick totally enclosed dust proof duly painted with powder coated fully wired up and ready to connect lead and control lines commissioning and testing complete all as specified and as directed by the Engr-in-Charge. The scope of work also comprising of the following :-(i) MCCB 400 Amp 50 kA 4 Pole thermal - 01 Nos Make L&T(ii) Capacitor duty contactor for 25 KVAR - 02 Nos Make L&T (iii) Capacitor duty contactor for 20 KVAR - 02 Nos Make L&T (iv) Capacitor duty contactor for 15 KVAR - 02 Nos Make L&T (v) Capacitor 25 KVAR - 02 Nos Make L&T (vi) Capacitor 20 KVAR - 02 Nos Make L&T (vii) Capacitor 15 KVAR - 02 Nos Make L&T (viii) MCB 63 Amp 10 KA TP for 25 KVAR - 02 Nos Make L&T(ix) MCB 63 Amp 10 KA TP for 20 KVAR - 02 Nos Make L&T (x) MCB 25 Amp 10 KA TP for 15 KVAR - 02 Nos Make L&T(xi) APFC Relay 12 stage - 1 nos make L&T(xii) Indicating light red - 12 nos make L&T(xiii) Auto manual selector switch - 12 nos make L&T(xiv) Digital voltmeter (0-500V) - 1 nos make L&T(xv) Digital ameter (0-450 A) - 1 nos make L&T(xvi) Volt meter selector switch - 1 nos make L&T(xvii) Amp meter selector switch - 1 nos make L&T(xviii) Indicator light R Y B - 3 nos make L&T(xix) Bus bar 400 A 34 strip & N/L 400 A ALU - 1 Set(xx) C.T's 400/5 A CL 1.0 Tape Wound- 01 Set. (Set of three)Make of APFC panel : L&T/ Universal switchgear/SMS Panel & Switchgears
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%