Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date2 Sep 2024
Closing Date24 Sep 2024
Tender Amount₹ 42,00,000
Costs
EMD
₹ 84,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair Replacement Of 11 Kv Cable Including Joints Transformer Rmu Plinths Fencing 11 Kv Bus Bar Chamber And Transformer Vcb Rmu Battery Charger Relay And Connected Items At Arjan Vihar New Pratap Chowk Pratap Chowk Mandir Marg Station
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_669757_1Bid Award Id
ViewTender No
GE ELEC/D-40/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by Engineer- in- Charge.
157.14
-
-
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm complete all as specified and directed by Engineer- in- Charge.
5174
-
-
All as per srl item No 5 here-in-before but using old cable cover obtained under srl item No 1 here in before complete all as specified and directed by Engineer- in- Charge.
3449
-
-
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed by Engineer- in- Charge of following sizes :-
-
-
-
95 sqmm 3 core.
350
-
-
120 sqmm 3 core.
510
-
-
150 Sqmm 3 Core
210
-
-
185 sqmm 3 core
480
-
-
240 sqmm 3 core
210
-
-
300 sqmm 3 core
180
-
-
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.6 mpa working pressure complete all as specified and directed by Engineer- in- Charge.
20
-
-
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 100 to 150 mm bore and making good both ends complete all as specified and directed by Engineer- in- Charge.
18
-
-
S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah of following bore sizes complete all as specified and directed by Engineer- in- Charge.
-
-
-
150mm
6
-
-
100 mm .
12
-
-
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
-
-
-
95 Sqmm 3 core.
2
-
-
120 Sqmm to 185 Sqmm, 3 core.
2
-
-
240 Sqmm to 400 Sqmm 3 core
2
-
-
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
-
-
-
95 Sqmm 3 core.
2
-
-
120 Sqmm to 185 Sqmm, 3 core.
2
-
-
240 Sqmm to 400 Sqmm 3 core
2
-
-
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
-
-
-
95 Sqmm 3 core.
4
-
-
120 Sqmm to 185 Sqmm, 3 core.
6
-
-
240 Sqmm to 400 Sqmm 3 core
4
-
-
Material and labour for Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed.
Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc.
(b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
6
-
-
Material and labour for in replacement 32x6mm galvanised iron strip for earth continuity conductor for earthing of transformer , GOD , 4/6 pole , structure etc complete all as specified and directed by Engineer- in- Charge at site.
15
-
-
Material and labour for cutting and removing grass, vegetation bushes etc from surrounding 4 pole/6 pole HT structure , outside area of HT installation and removing all rubbish to a distance not exceeding 50 m complete all as specified and directed by Engineer- in- Charge.
150
-
-
Suplying and laying as replacement in sub station fixing 3.3 to 11 KV electrical insulation mat of size 5 mtr x 1 mtr x 2.5 mm thick specification complete all as specified and directed by Engineer- in- Charge.
12
-
-
Supplying and fixing in replacement LED flood light fitting of following size complete all as specified and directed by Engr-in-charge :-
-
-
-
120 watt
4
-
-
200 Watt
4
-
-
Supplying & fixing of LED street light Fitting 60 watt LED, IP-66 protection, single piece pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 4.5 KV, prewired conductor to fitting with 3 core 1.5 sqmm pvc insulated cable along with GI pipe bracket for street light fitting complete with 2.2 mtr long 50mm dia GI pipe medium grade and including necessary mild steel clamp , nuts,bolts and wahsers and painting on steel surfaces with two coats of aluminium paint complete all as specified and directed by Engineer- in- Charge.
15
-
-
Supplying & fixing of LED street light Fitting 45 watt LED, IP-66 protection, single piece pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 4.5 KV, prewired conductor to fitting with 3 core 1.5 sqmm pvc insulated cable along with GI pipe bracket for street light fitting complete with 2.2 mtr long 50mm dia GI pipe medium grade and including necessary mild steel clamp , nuts,bolts and wahsers and painting on steel surfaces with two coats of aluminium paint complete all as specified and directed by Engineer- in- Charge.
12
-
-
Supplying & fixing in replacement ACB 4 pole, 800 Amp, 50 KA, 415 Volt AC Horizontal draw out type , front operated with Micro processor based LCD protection release for adjustable over current, short circuit and earth fault protection complete all as specified and directed by Engineer- in- Charge.
1
-
-
Supplying, installation & commissioning in replacement of 12 Volts-100 AH sealed maintenance free battery complete all as specified and directed by Engr-in-charge.
4
-
-
Disconnecting electrically & mechanically outdoor transforemrs upto 630 KVA capacity, lowering down/getting out from plinth carefully for repairing /making of plinth of transformer and re- connecting electrically and mechanically after repairing/making of plinth , testing and commissioning complete complete all as specified and directed by Engineer- in- Charge. Note:- (a) Rate is deemed to be inclusive for hydra , men power, and other items required for temp energization of transformer.
(b) M&L required for repairing the Plinth shall be measured and paid separetely under items of sch of work here-in -after.
4
-
-
Material & Labour for brick masonry platform (suitable for 100 to 630 KVA transformer) having size 2.5 mtr x 2.5 mtr and total height 1.6 M (0.45 M below ground level including excavation and earth work, 1.15M above ground level including RCC slab 150 mm on top and refilling of sand/soil), PCC 1:4:8 type D-2 in foundation, sub class 'B' brick work in CM 1:4, 15mm thick rendering in CM 1:6 on all sides of platform upto 150 mm below ground level, supply and fixing of 02 Nos MS channels of suitable size for balancing of transformer, embedded in PCC 1:2:4 type B-1 up to 150mm thick RCC slab, including provn of stair case on one side complete all as specified and directed by Engineer- in- Charge.
4
-
-
Supply in replacement and Installation of LT CT operated Trivector Meter with the following specifications:-
(a) Meter Type: LT 3 Phase 4 Wire Electronic Tri vector Meter
(b) Standard: IS 13779:1999 / CBIP 88 (c) Accuracy: Class 0.5
(d) Voltage and Current rating:-
(i) Reference Voltage - 3x240 V (ii) Basic Current (Ib) - 5 A
(iii) Maximum continuous current (Imax) - 10 A
(e) Rated Frequency (variation) - 50Hz (±5%)
(f) Power consumption:-
(i) Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency
(ii) Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature
(g) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height
(h) Display in the event of Power Failure: Internal battery back-up for LCD display
(j)Communication port:
(i) Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is provided (ii) RS 485 for DLMS protocol
(iii) Energy recording - Unidirectional
2
-
-
Supplying & fixing in replacement of MS work of angles for post and struts of fencing around RMU/Transformer etc drilling holes, flat iron ,fillet for securing wire mess by welding to angle iron frame and framed work as in gate of angle and wire mess .Door to be fixed by 03 Nos 100mm long hinges and one sliding door bolt of 300mm long for locking arrangement and MS channel for plinth of transformer complete all as specified and directed by Engineer- in- Charge.
3.5
-
-
Supplying & fixing in replacement 3.15mm dia MS wire 75x75mm mesh , made up into mattress or cages appx 2.00 mtr height and fixed with flate iron /angle by welding in position complete all as specified and directed by Engineer- in- Charge.
75
-
-
Material & Labour for 2 coat of synthetic enamel painting over a coat of red oxide to MS wire fencing including preparation of new surface complete all as specified and directed by Engineer- in- Charge.
75
-
-
Supplying & fixing in replacement of UNSV /Burnt MCCBs of capacity 400 Amps, FP, 35 KA, 415 Volts 50 Hz, AC, with microprocessor release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as specified and directed by Engineer- in- Charge.
3
-
-
Supplying & fixing in replacement of UNSV /Burnt MCCBs of capacity 250 Amps, FP, 35 KA, 415 Volts 50 Hz, AC, with adjustable therma release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as specified and directed by Engineer- in- Charge.
3
-
-
Material & Labour for painting of transformer installed on plinth/4/6 pole structures at various site of capacity upto 630 KVA with existing colour, with spraying machine, after cleaning, preparation of outer surface of transformer, including writing of SM No, MES and capacity of transformer complete all as specified and directed by Engineer- in- Charge.
8
-
-
Supplying & fixing in replacement for Danger Notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white , with letters, figures and conventional skull and bobes in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25x20 cm size including taking down old one complete all as specified and directed by Engineer- in- Charge.
20
-
-
Supplying , installation & commissioning in replacement of 24V/40A Float Cum Boost Battery Charger unit including battery bank comprising 02 Nos of 12 Volts-100 AH sealed maintenance free battery. The CCCV battery charger consisting of copper wound, air cooled transformer, 01 Set single phase full wave bridge rectifier consisting of diodes and SCRs, liberally rated mounted on heat sink and complete with resistor/condenser network for surge supperssion . During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DC digital ammeter , DC digital voltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility for fuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom . The battery charger shall be divided into two compartments. The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:-
(a) Input working voltage-180 -270 Volts (b) Nominal Input Voltage - 230 V , AC , 50 Hz,1
(c) On load input power factor - 0.8
(d) On load unit watt efficiencies- 80% (e) No load losses of complete charge- 10% (f) Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell .
(j) Float charging -2.15 V/Cell
(k) Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode.
(l) Reverse polarity -No damage will caused . A visual indication for reverse polarity will appear with an audio alarm.
(m) Short circuit-MCB protecton provided.
Make of battery charger. Statcon/Sinetrac/Amar Raja
Make of batteries. Exide/Amaron/Okaya
1
-
-
Taking out faulty underground 11000 Volt HT cable of different sizes by excavation and removing PCC cover of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required. Note: (a) 11000 Volt HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable PCC cable cover will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs.
(c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
90
-
-
Material & Labour for re-painting of LT Steel tubular poles of any sizes with applying of 2 coats of aluminium paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed by Engineer- in- Charge.
250
-
-
Supply and fixing KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amps and 6 Amps MCB with base including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body with MS clamp of suitable sizehaving suitable size nut,bolts & washer complete all as specified and directed by Engineer- in- Charge.
25
-
-
Supply and fixing mild steel chequered plates Fe410-10-W(Gde-E-250) qualityon cable pit sizes as required on site 6mm to 10 mm thick including taking out old unsv RCC duct cover complete all as specified and directed by Engineer- in- Charge.
350
-
-
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
-
-
-