If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 96,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_664266_1Bid Award Id
ViewTender No
GE/DE-37/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR/ REPLACEMENT OF UNSV POINT WIRING, FITTING/ FIXTURE, DB, UNSV EARTHING, BLDG SECURITY LIGHT, FABRIC LIGHT AT ZONE B OFFICERS ACCN, WARDS, MH LINE NEW OPD COMPLEX AND E/M INSTALLATIONS UNDER GE (EAST) DELHI CANTT-10
BOQ Items
All same as per srl item No 3.00 here-in-before but including sunken type CI / MS Box with 3mm thick plastic laminated bakelite sheet.
200
-
-
All same as per srl item No 3.00 here-in-before but for one three pin, 5 Amp, socket out let on independent board.
250
-
-
All same as per srl item No 3.00 here-in-before but for one three pin, 5 Amp, socket out let on same board.
100
-
-
All same as per srl item No 3.00 here-in-before but for one light point controlled by two Nos, two way switches complete.
10
-
-
All same as per srl item No 3.00 here-in-before but point wiring with 2.5 Sqmm on independent board.
150
-
-
All same as per srl item No 3.00 here-in-before but point wiring with 2.5 Sqmm on Same board.
100
-
-
All same as per srl item No 3.00 here-in-before but point wiring with 4 Sqmm on independent board.
80
-
-
Material and labour of point wiring complete with 1.5 Sq mm (nominal area) FRLS PVC insulated sheathed and multistranded copper conductor cable ISI marked and including PVC casing & capping on wall ISI marked of size 20/25 medium grade and fittings such as tees, bends, elbow and 1.5Sqmm FRLS PVC insulated unsheathed copper conductor mulistranded earth wire, connecting to common earth dolly and making good disturbed surface for one light point/ fan/ bell point controlled by one 1-way switch complete all as directed.
100
-
-
All same as per srl item No 11.00 here-in-before but for one three pin, 5 Amp, socket out let on independent board.
70
-
-
All same as per srl item No 11.00 here-in-before but for one three pin, 5 Amp, socket out let on same board.
40
-
-
All same as per srl item No 11.00 here-in-before but point wiring with 2.5 Sqmm, cable, for 15 Amps socket outlet on independent board.
100
-
-
All same as per srl item No 11.00 here-in-before but point wiring with 4 Sqmm, cable, on independent board.
50
-
-
S&F in replacement modular cover plate with frame, 1 or 2 module complete all as specified and as directed.
50
-
-
S&F in replacement modular cover plate with frame, 3 modules complete all as specified and as directed. Make - Indoasian / Anchor Roma/ Legrand
150
-
-
S&F in replacement modular cover plate with frame, 4 modules complete all as specified and as directed. Make - Indoasian / Anchor Roma /Legrand
75
-
-
S&F in replacement modular cover plate with frame, 6 modules complete all as specified and as directed. Make - Indoasian / Anchor Roma /Legrand
125
-
-
S&F in replacement modular cover plate with frame, 8 modules complete all as specified and as directed. Make - Indoasian / Anchor Roma /Legrand
40
-
-
S&F in replacement modular cover plate with frame, 12 modules complete all as specified and as directed. Make- Indoasian / Anchor Roma /Legrand
80
-
-
S&F in replacement modular metal flush box, 1 or 2 modules complete all as specified and as directed.
50
-
-
S&F in replacement modular metal flush box, 3 modules complete all as specified and as directed.
150
-
-
S&F in replacement modular metal flush box, 4 modules complete all as specified and as directed.
75
-
-
S&F in replacement modular metal flush box, 6 modules complete all as specified and as directed.
125
-
-
S&F in replacement modular metal flush box, 8 modules complete all as specified and as directed.
40
-
-
S&F in replacement module metal flush box, 12 modules complete all as specified and as directed.
80
-
-
S&F in replacement modular switch, 1 way, 6 Amp, 1 Module, complete all as specified and as directed. Make - Indoasian / Anchor Roma / Legrand
855
-
-
S&F in replacement modular switch, 2 way, 6 Amp, 1 Module, complete all as specified and as directed. Make - Indoasian / Anchor Roma / Legrand
20
-
-
S&F in replacement modular bell push, 6 Amp, 1 Module complete all as specified and as directed. Make - Indoasian / Anchor Roma / Legrand
20
-
-
S&F in replacement modular Socket, 6Amp, 2/3 Pin, combined, 2 module complete all as specified and as directed.Make - Indoasian / Anchor Roma / Legrand
350
-
-
S&F in replacement modular Socket, 16/6 Amp, 3/5 Pin, combined, 2 module complete all as specified and as directed.Make - Indoasian / Anchor Roma / Legrand
250
-
-
S&F in replacement modular Fan step regulator, 120W - 2 module complete all as specified and as directed. Make - Indoasian / Anchor Roma / Legrand
100
-
-
S&F in replacement Lamp holder, white, Polycarbonate body, with back plate, suitable for batten fittings, fixed in position & connecting complete all as specified and as directed.
50
-
-
S&F in replacement Ceiling rose, PVC/ polycarbonate, isolated body type, three terminal, 240 volt, fixed in position & connecting complete all as specified and as directed.
235
-
-
S&F in replacement Bell ding dong, AC, 230 Volts, fixed in position & connecting complete all as specified and as directed.
20
-
-
Supply and fix in replacement Switch Piano type, white polycarbonate body, single pole, one way 5 amp, 230 V, including connecting complete.Make :- Anchor, Cona, Legrand
210
-
-
Supply and fix in replacement Switch Piano type, white polycarbonate body, single pole, one way 15 amp, 230 V, including connecting complete.Make :- Anchor, Cona, Legrand
100
-
-
Supply and fix in replacement Socket outlet 2 in 1, 3 pin, 5 and 15A - 230 V, Multipurpose flush type, including connecting complete.Make :- Anchor, Cona, Legrand
100
-
-
Supply and fix in replacement Socket outlet 2 in 1, 3 pin, 5A ,230 V including connecting complete. Make :- Anchor, Cona, Legrand
100
-
-
Supply and fix in replacement stepped type electronic fan regulator, white polycarbonate body, flush type, 230 V, including connecting complete.Make :- Anchor, Cona, Legrand
50
-
-
S&F sub main wiring with 2 runs of 4 Sqmm FRLS single core PVC insulated & unsheathed cabl, 1100 Volts grade with multi stranded copper conductor drawn through and including 20 mm dia concealed PVC rigid non metallic conduit medium grade as per IS with all fittings and one run of 4 Sqmm FRLS PVC insulated copper conductor including cutting chases and making good in CM 1:3 to match with existing surfaces complete all as specified and as directed. Make :- Havells/
Note:- (Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
600
-
-
S&F sub main wiring with 2 runs of 6 Sqmm FRLS, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 6 Sqmm FRLS, PVC insulated copper conductor including cutting chases and making good in CM 1:3 to match with existing surfaces complete all as specified and as directed. Note:- (Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
500
-
-
S&F sub main wiring with 4 runs of 10 Sqmm FR, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 32 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and two run of 10 Sqmm FR, PVC insulated copper conductor including cutting chases and making good in CM 1:3 to match with existing surfaces complete all as specified and as directed. Note:- (Four run of cable along with 2 run earth conductor including PVC rigid conduit shall be measured as one RM length).
500
-
-
S&F in repair load line, distribution board, double door type, TPN, vertical, 4 way, suitable for accomodating upto 125 Amps MCCB with incomming frame three pole, including 250 Amp copper bus bar, neutral link, blanking plates etc complete all as specified and as directed. Make : Legrand Model: 5077 45 or equivalent model of Make mentioned in PS.
4
-
-
S&F in repair load line, distribution board, double door type, TPN, vertical, 8 way, suitable for accomodating upto 125 Amps MCCB with incomming frame three pole, including 250 Amp copper bus bar, neutral link, blanking plates etc complete all as specified and as directed. Make : Legrand Model: 5077 47 or equivalent model of Make mentioned in PS.
4
-
-
S & F in repair for distribution board double door type, SPN, 12 way, complete including 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and directed.
Make-Legrend/ Havells/ ABB/ Indoasian
15
-
-
S & F in repair for distribution board double door type, SPN, 8 way, complete including 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and directed.
Make-Legrend/ Havells/ ABB/ Indoasian
10
-
-
Supply, fixing and connecting in replacement recessed mounting back- lit LED 2X2, 36 watt tile in CRCA housing with full opal diffuser suitable for Armstrong/ Grid Ceilings Type, size 595X595mm (Nominal),High lumen efficacy LED with viewing angle of 120 degree used to enhance the luman output Height suitable for White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection minimum 2.5KV, safety & performance test as per IS:15885 Total system Lumen not less than 3600, in Cool day Light (6500K), Power factor0.95, CRI (Ra) 80 with Average life of 50000 Burning hours complete with all accessories as required complete all as specified and as directed. Make : ORIENT Model No :- LTRAQ-36-C-VO or equivalent in Havells/ wipro/CG.
100
-
-
Supply, fixing and connecting in replacement of Slim LED Batten 10 watt with Surface/Wall Mounted integrated LED 2 feet Fitting Polycarbonate housing and diffuser with viewing angle of 120 degree used to enhance the luman output Height suitable for White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection up to 2.5 KV . Total system Lumen of 10W Led should be 1000 or above in Cool day Light(6500K), Power factor0.9, CRI (Ra) 80, System with Average life of 50000 Burning hours complete with all accessories as required complete all as specified and as directed.Make : ORIENT Model No :- LBLN-10-C- SQ or equivalent in Havells/ wipro/CG.
80
-
-
Supply, fixing and connecting in replacement of Slim LED Batten 20 watt with Surface/Wall Mounted integrated LED 4 feet Fitting Polycarbonate housing and diffuser with viewing angle of 120 degree used to enhance the luman output Height suitable for White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection up to 2.5 KV . Total system Lumen of 20W Led should be 2000 or above in Cool day Light(6500K), Power factor0.9, CRI (Ra) 80, System with Average life of 50000 Burning hours complete with all accessories as required complete all as specified and as directed.Make : ORIENT Model No :- LBLN-20-C- SQ or equivalent in Havells/ wipro/CG.
100
-
-
S&F in replacement Bldg security light fitting LED 25 Watt, highly efficient IP66 LED, high power having aluminium pressure die cast housing and PC cover in the front and high power lens for batwing light distribution with electric connection with suitable size of PVC insulated copper wire including GI bracket 1.5 Mtr with clamps and bolts complete all as specified and directed.
Make : ORIENT Model No :- LSFS-25-CF-PC or equivalent in Havells/ wipro/CG.
15
-
-
Supply, fixing and connecting in replacement of Ultra Slim recess mounting round LED down light 6 watt with excellent thermally manged aluminium pressure die cast housing for larger surface area finished in epoxy powder coated white to deliver high efficacy light output complete all as specified and as directed.Make : ORIENT Model No :- LDRER-06-C-V1 or equivalent as per list of makes in PS.
20
-
-
Supply, fixing and connecting in replacement of Ultra Slim recess mounting round LED down light 12 watt with excellent thermally manged aluminium pressure die cast housing for larger surface area finished in epoxy powder coated white to deliver high efficacy light output complete all as specified and as directed.Make : ORIENT Model No :- LDRER-12-C-V1 or equivalent in Havells/ wipro/CG.
20
-
-
Supply, fixing and connecting in replacement of Ultra Slim recess mounting round LED down light 15 watt with excellent thermally manged aluminium pressure die cast housing for larger surface area finished in epoxy powder coated white to deliver high efficacy light output complete all as specified and as directed.Make : ORIENT Model No :- LDRER-15-C-V1 or equivalent in Havells/ wipro/CG.
30
-
-
S&F CUBOID LOW HEIGHT Ceiling fan 400mm sweep, 230 Volt, 50 Hz, speed 1750 RPM , type with built in LED light and remote controll in white colour with connection incl necessary cutting in ceiling complete all as specified and directed. MAKE - HALONIX NOTE:- Old Unsv Cuboid fan deposited into MES Store.
15
-
-
S&F in replacement CUBOID LOW HEIGHT Ceiling fan LED Light complete all as specified and directed. Make- Havells / Usha
20
-
-
S&F in replacement CUBOID LOW HEIGHT Ceiling fan single phase induction motor 87 Watt capacity complete all as specified and directed.MAKE - HALONIX/Havells / Usha
15
-
-
S&F in replacement CUBOID LOW HEIGHT Ceiling fan 400mm sweep 12 inch 3 wing blade complete all as specified and directed. MAKE - HALONIX
15
-
-
S&F in replacement CUBOID LOW HEIGHT Ceiling fan outer grill complete all as specified and directed. MAKE - HALONIX
15
-
-
S&F in replacement CUBOID LOW HEIGHT Ceiling fan Remote Control complete all as specified and directed. MAKE - HALONIX
10
-
-
S&F in replacement CUBOID LOW HEIGHT Ceiling fan Swing Motor complete all as specified and directed. MAKE - HALONIX
15
-
-
S&F in replacement CUBOID LOW HEIGHT Ceiling fan PCB Board complete all as specified and directed. MAKE - HALONIX
15
-
-
S&F in replacement Automatic infrared Sensor High Jet Speed Fast Dry Hand Dryer Machine complete all as specified and directed. MAKE - Dolphy
5
-
-
M&L in replacement for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts, checknuts and washers of galvanized iron or steel as shown in electrical plate No 3 connected to earthing test point including testing on completion all as directed.
Note:- The unit rate quoted shall be include for necessary excavation and earth work ,earth strip connected to test point max 7 mtr as per site requirement, PCC 1:3:6 type for earth pit & Pit cover, funnel with wire mesh including GI light grade 15mm bore as protection pipe and 20mm dia medium grade GI pipe as water pipe.
10
-
-
Taking down ceiling fan, exhaust fan including connection cable, dismantling blades and refixing & reconnecting the same after necessary repair/rewinding/painting etc complete all as specified and as directed. Note: Servicing/Rewinding/Painting of Fan shall be measured and seprately under respective item of this Schedule.
200
-
-
M & L for painting of ceiling fans/ exhaust fan complete, with syntetic enamel paint as per existing color by one coat spray painting including filling cavities with filler, including cleaning all dust complete all as specified and as directed.
200
-
-
M&L for servicing of ceiling fans/exhaust fan/wall fan /padestal fan of any Make and sizes, carrying out minor repair such as greasing, oiling, fitting, testing complete all as specified and as directed.
250
-
-
M&L rewinding ceiling fan of any make and model, 1200 /1400 mm sweep, with super enamelled copper wire of required size, duly varnishing with high quality Varnish, including greasing & servicing and testing including taking down old winding wire complete all as specified and as directed.
200
-
-
All as per item No. 69.00 here in before but rewinding Exhaust fan of size 200mm to 300mm complete all as specified and as directed.
50
-
-
All as per item No. 69.0 here in before but rewinding Paedestal fan of size 400mm complete all as specified and as directed.
20
-
-
All as per item No. 69. 00 here in before but rewinding wall fan of size 400 mm complete all as specified and as directed.
20
-
-
S&F in replacement bearing No 6200/6201/6203/6204 suitable for Ceiling fans/Exhaust fan of existing make and size, for proper running including testing complete all as all as specified and as directed. (Note: Testing shall be done in MES store yard at contractor's expense).
120
-
-
S&F in replacement bush suitable for Ceiling fans/Exhaust fan/padestal fan/wall fan of existing make and size, for proper running including testing complete all as all as specified and as directed. (Note: Testing shall be done in MES store yard at contractor's expense).
60
-
-
S&F in replacement capacitor 2.5 Mfd complete all as all as specified and as directed.
150
-
-
S&F in repair Fan rod, 1.5 feet long, made out of 20 mm bore GI pipe, with necessary clamps & nut bolt and other accessories complete all as specified and as directed.
50
-
-
S&F in repair Fan rod,2/3 feet long, made out of 20 mm bore GI pipe, with necessary clamps & nut bolt and other accessories complete all as specified and as directed.
50
-
-
S&F in repair Fan rod, 2.5 feet long, made out of 20 mm bore GI pipe, with necessary clamps & nut bolt and other accessories complete all as specified and as directed.
70
-
-
S&F in repair PVC casing caping, medium grade, size 25 X 16 mm, including necessory accessories (Tee, elbow etc) & clamp, screw, rowel plug etc. complete all as specified and as directed.
300
-
-
S&F in repair Rigid, non-metallic, PVC conduit, medium grade, 20mm bore, including all fittings such as tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and as directed.
300
-
-
All as per item No 80.00 here in before but 25 mm bore complete all as specified and as directed.
300
-
-
S&F in repair modular blanking plate, 1 Module complete all as specified and as directed.
100
-
-
S&F in repair Plastic surface box 3 module for 3 Module Sheet cover complete all as specified and as directed. Make - Anchor Roma/ indoasian
50
-
-
S&F in repair Plastic surface box 6 module for 6 Module Sheet cover complete all as specified and as directed. Make - Anchor Roma/ indoasian
50
-
-
S&F in repair Plastic surface box 12 module for 12 Module Sheet cover complete all as specified and as directed. Make - Anchor Roma/ indoasian
50
-
-
S&F in repair PVC Ventilation fan 250 mm sweep 240 Volt, 1325RPM , Air delivery 500 CMM connection with self closing louver frame flexible PVC copper wire from ceiling rose to exhaust fan including provn of opening of hole on brick wall and grouting nut and bolt of suitable size complete all as specified and directed. Make:-Havells/Bajaj / CG
20
-
-
S&F in repair PVC Ventilation Fan 300mm sweep 240 Volt, 1325RPM , Air delivery 500 CMM connection with self closing louver frame flexible PVC copper wire from ceiling rose to exhaust fan including provn of opening of hole on brick wall and grouting nut and bolt of suitable size complete all as specified and directed. Make:-Havells/Bajaj/ CG
20
-
-
Cutting chases, pinning in, including making good in cement mortar 1:3 including painting to match with the existing surface as in edges of landings, steps, cills, sunshades, shelves, lintels, etc; and for concealed conduit wiring, etc, cutting not exc10 cm girth complete all as specified and as directed.
300
-
-
S&F in repair sheet metal enclosure with socket plug top, single pole and neutral enclosure with a two pin earth plug and socket complete with one MCB of capacity 20 Amps , 240 Volts complete all as specified and directed. Make:-Legrand/seimens/ schneider/ Indoasian.
80
-
-
S & F in repair MCCB 415 V, 125 Amps, 25 KA, 4 Pole complete all as specified and directed.Make -Legrend / ABB / Seimens / L&T / HAVELLS
12
-
-
S & F in repair MCCB 415 V, 100 Amps, 35 KA, 4 Pole complete all as specified and directed.Make -Legrend / ABB / Seimens / L&T / HAVELLS
12
-
-
S & F in repair MCB TPN, 415 Volts, 63 Amps complete all as specified and directed. Make -Legrend / ABB / Seimens / L&T / HAVELLS
15
-
-
S & F in repair MCB TP, 415 Volts, 40 Amps complete all as specified and directed. Make -Legrend / ABB / Seimens / L&T / HAVELLS
10
-
-
S & F in repair MCB DP, 240 Volts, 40 Amps complete all as specified and directed. Make -Legrend / ABB / Seimens / L&T / HAVELLS
60
-
-
S & F in repair MCB DP, 240 Volts, 63 Amps complete all as specified and directed. Make -Legrend / ABB / Seimens / L&T / HAVELLS
20
-
-
S & F in repair MCB SP, 240 Volts, 16 Amps complete all as specified and directed. Make -Legrend / ABB / Seimens / L&T / HAVELLS
100
-
-
S & F in repair MCB SP, 240 Volts, 10 Amps complete all as specified and directed. Make -Legrend / ABB / Seimens / L&T / HAVELLS
50
-
-
S & F in repair MCB SP, 240 Volts, 32Amps complete all as specified and directed. Make -Legrend / ABB / Seimens / L&T / HAVELLS
120
-
-
S & F in repair MCB SP, 240 Volts, 63 Amps complete all as specified and directed. Make -Legrend / ABB / Seimens / L&T / HAVELLS
50
-
-
S&F in replacement ultra thin corded electric 12 Volt , 300 watt LED switching Power Supply with universal regulated transformer for input voltage of 250 Volt 50 Hz AC to output of DC 12 Volt , 25 Amp for power supply to strips fabric LED Lights ,having other features like anti jamming , surge protection ,over load and over voltage protection complete in aa aspect all as specified as directed.
20
-
-
S & F in replacement LED strip rope light for perfect ambiance to use in both indoor and outdoor having rating 6 watt per meter and output of 400 Lm/ Mtr. LED count 72 LEDs per meter waterproofing with IP 65 protection flexible, slim and compact applicable for bendable and agled pattern or in continous rows complete in all aspect all as specified and as directed.Make- Philips