Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date18 Jan 2025
Closing Date8 Feb 2025
Tender Amount₹ 30,00,000
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_693834_1Tender No
GE/RND/T-98/DLI/2024Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://mes.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supply, installation, testing and commissioning in replacement of Addressable 2 wire Multi-Criteria Detector ( Photoelectric Smoke + Heat detection) with built-in short circuit isolator, 100% soft addressing, single LED that covers 360Deg lightpipe technology with intensity that can handle upto 5000 Lux, Drift compensation, detector sensitivity of 2.55+/- 0.33%/ft, Chamber monitoring by panel, option to connect remote indicator. Detector should be provided with Base. Certification: EN54 Approved complete all as specified and directed.
150
-
-
... More
Supply, Installation, testing and commissioning in replacement of Addressable 2 wire Multimode Thermal heat detector with built-in short circuit isolator, 3 operating temperature of detector selectable from panel, 100% soft addressing, single LED that covers 360Deg lightpipe technology with intensity, Discreet design for incorporation into any décor, Common mounting base, Drift compensation, Removable detector chamber, Chamber monitoring by panel, option to connect remote indicator. Certification: EN54 Approved complete all as specified and directed.
120
-
-
... More
S&F in replacement 2 Core X 1.5 Sq.mm 1100V, stranded Class 2 Copper Conductor, XLPE insulated, Extruded PVC Type ST2 inner sheath, Galvanised Round wire armour(0.9mm), Extruded FR-LSH PVC Type ST2 Outer sheath Generally as per BS : 5467 complete all as specified and directed.
450
-
-
... More
Supply, Installation, testing and commissioning in replacement of Addressable 2 wire break glass manual call point with built in short circuit isolator, 100% soft addressed from panel, Wall mounting, resettable key option with back box. Certification: EN54 Approved complete all as specified and directed.
7
-
-
... More
Supply, Installation, testing and commissioning in replacement of Addressable loop powered Wall mount sounder with strobe, 100% soft addressed from panel, with 3 tones, Low volume: 87dB at 8.6mA & High volume: 100dB at 11mA, shall be with inbuilt isolator. Certification: EN54 Approved complete all as specified and directed.
6
-
-
... More
S&F in replacement Fire Alarm sounders/ Sirens electronic type horizontal two stage continuous normal operation for at least 50 minutes with sound level 65 db to 120 db measured at 1.5m with sound output variation of +5 db 1000 mtr range complete all as specified and directed.
1
-
-
... More
Supply, Installation, testing and commissioning in replacement of remote indicator discreet design for incorporation in to any décor complete all as specified and directed.
120
-
-
... More
Supply, installation, testing & commissioning in replacement of Booster Amplifier capable of delivering 240 Wattage RMS power output for speakers, built-in fan for temperature control, built in line matching transformer distortion typically 3% @1 KHz, S/N 80 dB complete as required complete all as specified and directed.
1
-
-
... More
Supply,Installation,Testing & Commissioning in replacement of 5" 6W Ceiling Speaker with SPL at rated power/1W 92dB (1m & 1kHz). Frequency response of 125Hz – 16kHz (-10 dB with reference to 1kHz). The speaker should have tappings at 6W/3W/1.5W complete all as specified and directed.
7
-
-
... More
Supply & Fix in replacement battery 12 volts 7 AH maint free. complete all as specified and directed.
8
-
-
... More
Supply & Fix in replacement of Zonal Card as per matching to existing complete all as specified and directed.
2
-
-
... More
M&L for repair of Zonal Card complete all as specified and directed.
4
-
-
... More
Supply & Fix in replacement control card as per matching to existing all as specified and directed.
2
-
-
... More
M&L for repair of control card all as specified and directed.
2
-
-
... More
Supply only in replacement of power card as per matching to existing all as specified and directed.
1
-
-
... More
M&L for repair of power card all as specified and directed.
2
-
-
... More
Supply & Fix in replacement of Auto dialar for Microprocessor based panel complete all as specified and directed.
2
-
-
... More
Supply, install, testing and commissioning of Microprocessor based Master/slave fire alarm cum detection control panel upto 10 zones with power supply and battery charger alongwith maint free batteries complete all as specified and directed.
1
-
-
... More
Supply & Fix in replacement multi sensor (combination of photoelectric and ROR heat detector) including testing complete after servicing complete all as specified and directed.
15
-
-
... More
Supply & Fix in replacement Heat detector with base fixed temp all as directed.
20
-
-
... More
M&L for fixing of steel conduit of size 20 mm on wall/ceiling with clamps, screw and all connected items all as directed.
70
-
-
... More
Taking down of Old unserviceable point wiring any type for light, fan, power etc including unserviceable switch,socket, regulator light fitting and ceiling rose etc of any make complete including making good disturbed surfaces of walls ,floors roof etc complete all as specified and directed.
410
-
-
... More
M&L for Point wiring with 1.5 Sqmm multistranded copper conductor cable multistranded, FRLSH PVC insulated and unsheathed in and including PVC concealed connduit including cutting chasing for conduits and terminal boxes with all fittings /accessories and including 1.5 Sqmm PVC insulated copper earth wire connected common earth with terminal boxes for Modular fittings including acessories as modular metal flush box 2mm thick surface cover plate with frame, for one light/Fan/Exhaust Fan/bell point complete all as specified and directed.
20
-
-
... More
All description as per srl item No 26.00 here- in- before but using cable size 1.5 Sqmm for 1 Nos 05 Amps Socket outlet independent with terminal boxes, Moduler fittings including acessories as moduler metal flush box 2mm thick ,surface cover plate with frame, metal flush box,complete all as specified and directed.
15
-
-
... More
All description as per srl item No 26.00 here- in- before but using cable size 1.5 Sqmm for 1 Nos 05 Amps Socket outlet on the same board with other switches complete all as specified and as directed.
10
-
-
... More
All as per srl item No 26.00 here- in- before but using cable size 2.5 Sqmm for 15 Amps Socket outlet terminal boxes for Modular switches including acessories as moduler metal flush box 2mm thick ,surface cover plate with frame, metal flush box with 2.5 sqmm earth wire complete all as specified and directed.
30
-
-
... More
M&L for Point wiring with 1.5 Sqmm multistranded copper conductor cable FRLSH PVC insulated and unsheathed in existing connduit including cutting chasing for conduits and terminal boxes with all fittings /accessories and including 1.5 Sqmm PVC insulated copper earth wire connected common earth with terminal boxes for Modular fittings including acessories as modular metal flush box 2mm thick surface cover plate with frame, for one light/Fan/Exhaust Fan/bell point complete all as specified and as directed.
120
-
-
... More
All description as per srl item No 30.00 here- in- before but using cable size 1.5 Sqmm for 1 Nos 05 Amps Socket outlet independent with terminal boxes, Moduler fittings including acessories as moduler metal flush box 2mm thick ,surface cover plate with frame, metal flush box,complete all as specified and as directed.
45
-
-
... More
All as per srl item No 30.00 here- in- before but using cable size 2.5 Sqmm for 15 Amps Socket outlet terminal boxes for Modular switches including acessories as moduler metal flush box 2mm thick ,surface cover plate with frame, metal flush box with 2.5 sqmm earth wire complete all as specified and as directed.
65
-
-
... More
M&L for Point wiring with 1.5 Sqmm multistranded copper conductor cable multistranded, FRLSH PVC insulated and unsheathed in PVC casing & caping double lock including fixures and terminal boxes with all fittings /accessories and including 1.5 Sqmm PVC insulated copper earth wire connected common earth with terminal boxes for Modular fittings including acessories as modular surface cover plate with frame, for one light/Fan/Exhaust Fan/bell point complete all as specified and directed.
10
-
-
... More
All description as per srl item No 33.00 here- in- before but using cable size 1.5 Sqmm for 1 Nos 05 Amps Socket outlet independent with terminal boxes, Moduler fittings including acessories as moduler surface cover plate with frame, PVC box, complete all as specified and directed.
35
-
-
... More
All as per srl item No 33.00 here- in- before but using cable size 2.5 Sqmm for 15 Amps Socket outlet terminal boxes for Modular switches including acessories as moduler surface cover plate with frame, PVC box with 2.5 sqmm earth wire complete all as specified and directed.
60
-
-
... More
S&F in replacement of Plug Top 16 Amps complete all as specified and directed.
40
-
-
... More
S&F modular switch 6 Amp single pole one way-1 module Cat Part No W26401A Honeywell or equivalent complete all as specified and directed.
120
-
-
... More
S&F modular switch 6 Amp single pole one way-1 module Cat Part No 673000 of legrand or equivalent complete all as specified and directed.
90
-
-
... More
S&F modular switch 6 Amp single pole one way-1 module Cat Part No 21011 of Anchor Roma or equivalent complete all as specified and directed.
135
-
-
... More
S&F modular switch 16 Amp single pole one way-1 module Cat Part No W26411A Honeywell or equivalent complete all as specified and directed.
86
-
-
... More
S&F modular switch 16 Amp single pole one way-1 Module Cat part No 673008 of Legrand or equivalent complete all as specified and directed.
65
-
-
... More
S&F modular switch 16 Amp single pole one way-1 Module Cat Part No 21066 of Anchor Roma or equivalent complete all as specified and directed.
110
-
-
... More
S&F modular socket outlet shuttered-6A-2/3Pin-universal Indian 2 Module Cat Part No W26428 of Honeywell or equivalent complete all as specified and directed.
65
-
-
... More
S&F modular socket outlet shuttered-6A-2/3Pin-universal Indian 2 Module Cat part No 673044 of Legrand or equivalent complete all as specified and directed.
60
-
-
... More
S&F modular socket outlet shuttered-6A-2/3Pin-universal Indian 2 Module Cat Part No 30373 of Anhor Roma) or equivalent complete all as specified and directed.
80
-
-
... More
S&F modular socket outlet shuttered-16/6A-2/3Pin Indian 2 Module Cat part No W26424 of Honeywell or equivalent complete all as specified and directed.
70
-
-
... More
S&F modular socket outlet shuttered-16/6A-2/3Pin Indian 2 Module Cat Part No 673045 of Legrand or equivalent complete all as specified and directed.
65
-
-
... More
S&F modular socket outlet shuttered-20/6A-2/3Pin Indian 2 Module Cat part No 30828 of Anchor Roma or equivalent complete all as specified and directed.
110
-
-
... More
S&F Fan step regulator 120W - 2 Module Cat part No 673029 of Legrand or equivalent complete all as specified and directed.
40
-
-
... More
S&F Fan step regulator 120W - 1 Module Cat part No 633027 of Legrand or equivalent complete all as specified and directed.
56
-
-
... More
S&F Fan step regulator 120W - 1 Module Cat part No W26473 of Honeywell or equivalent complete all as specified and directed.
40
-
-
... More
S&F Fan step regulator 120W - 2 Module Cat part No W26474 of Honeywell or equivalent complete all as specified and directed.
50
-
-
... More
M&L for Modular Bell push 6 Amp 2 Module Cat Part No 673022 of Legrand or equivalent complete all as specified and directed.
40
-
-
... More
M&L for Modular Bell push 6 Amp 2 Module Cat Part No W26404BNA of Honeywell or equivalent complete all as specified and directed.
60
-
-
... More
M&L for Modular Bell push 6 Amp 2 Module Cat Part No21496 of Anchor Roma or equivalent complete all as specified and directed.
50
-
-
... More
M&L in replacement of Bell ding dong AC 230Volts complete all as specified and directed.
50
-
-
... More
S&F in replacement of switch piano type flush type single pole one way 5 Amps complete all as specified and directed.
120
-
-
... More
S&F in replacement of socket outlet Piano type 2 in one 3 Pin 5 Amps complete all as specified and directed.
120
-
-
... More
S&F in replacement of switch piano type flush type single pole one way 16 Amps complete all as specified and directed.
90
-
-
... More
S&F in replacement of socket outlet piano type 2 in one 3 Pin 5 & 15 Amps complete all as specified and directed.
80
-
-
... More
S&F in replacenent of PVC connection 600mm long with brass Nut with rubber washer suitable hot/cold water complete all as specified and directed.
160
-
-
... More
Supply and fix Down Rod with connecting accessories suitable for ceiling fan of sweep 1200/1400 lengh 75 cm all as specified and directed
55
-
-
... More
Supply and fix Ball Bearing No 6201-6204 as reqd suitable for ceiling fan of sweep 1200/1400 complete all as specified and directed.
75
-
-
... More
Supply and fix ceiling fan hanging hook clamps (for fixing to ceiling fan rod) made with using GI of suitable size with heavy duty rubber insulator and two Nos nuts and one bolts including split pin complete all as specified and directed.
50
-
-
... More
Supply and fix heavy duty rubber insulator for 1200/1400 mm sweep for hanging ceiling fan complete all as specified and directed.
50
-
-
... More
Supply and fix capacitor 2.5 to 3.15 MFD as per existing capacity of 240 volts AC complete all as specified and directed.
400
-
-
... More
Supply and fix heating element any type as per site requirement of capacity 2 KW (Traingular/cup/box type as reqd) complete all as specified and directed.
150
-
-
... More
Supply and fix thermostat for geyser as per site requirement temp setting on 60 degree Centigrade complete all as specified and directed.
20
-
-
... More
Supply and fix LED indication lamp Green/Red as reqd suaitable for Water Storage Geyser complete all as specified and directed.
100
-
-
... More
Supply and fix flange assembly (Syphon) for 25 ltrs capacity of geyser and any type of hole (6 no) all complete with safety valves as per existing make & size as per size requirement complete all as specified & directed.
65
-
-
... More
Supply and fix surface mouting PVC gang box of super quality for three switches with two /four holes complete all as specified and directed.
30
-
-
... More
Supply and fix surface mouting PVC gang box of super quality for five to seven switches with two /four holes complete all as specified and directed.
30
-
-
... More
Supply and fix in replacement white hylam sheet of thickness 1.3 mm for mounting swithces sockets of size 9 x 6inch complete all as specified and directed.
100
-
-
... More
Supply and fix in replacement white hylam sheet of thickness 1.3 mm for mounting swithces sockets of size 5 x 5 inch complete all as specified and directed.
100
-
-
... More
Supply and fix in replacement white hylam sheet of thickness 1.3 mm for mounting swithces sockets of size 8 x 5 inch complete all as specified and directed.
75
-
-
... More
Supply and fix in replacement white hylam sheet of thickness 1.3 mm for mounting swithces sockets of size 9x 11 inch complete all as specified and directed.
100
-
-
... More
Supply and fix Metal Plug , 240V,20 A,2P+E suitable for Geyser's DB Enclosure all as specified and directed.
30
-
-
... More
Supply and fix Metal Socket , 240V,20 A,2P+E with blue cap suitable for Geyser's DB Enclosure all as specified and directed.
20
-
-
... More
Supply and fix PVC insulation tape of width 20 mm and length 10 Mtr complete all as specified and directed.
200
-
-
... More
Supply and fix saddle PVC nail type for fixing of PVC batton complete all as specified and directed.
10
-
-
... More
Supply and fix FASTNER , 100 mm long,8mm dia complete set with nuts & washers as specified & directed.
100
-
-
... More
Supply and fix nylone sleeve, SIZE 50MM complete all as specified and directed.
10
-
-
... More
Supply and fix nylone sleeve, SIZE 38MM complete all as specified and directed.
5
-
-
... More
Supply and fix gypsum screw, size 50mm complete all as specified and directed.
10
-
-
... More
Supply and fix gypsum screw, size 38mm complete all as specified and directed.
4
-
-
... More
Supply and fix in replacement super quality white flexible PVC pipe of 25 mm dia, complete all as specified and directed.
50
-
-
... More
Supply and fix in replacement PVC Casing & caping 25mm width complete all as specified and directed.
200
-
-
... More
Supply and fix in replacement Brass machine screw of size 1.50 inch long complete all as specified and directed.
10
-
-
... More
Supply and fix in replacement Brass machine screw of size 2 inch long complete all as specified and directed.
10
-
-
... More
Supply and fix 1100 volt heavy duty weather proof cable with PVC insulated stranded aluminium conductor ,served with inner sheathing of PVC tape and overall PVC Sheathed of size 10 Sqmm x 2 core complete all as specified and directed.
300
-
-
... More
Supply and fix PVC flexible wire two core twin twisted of size 23/0.0076 copper conductor all as specified and directed.
400
-
-
... More
Supply and fix flexible copper cable , three core of size 40/0.0060 with copper multistranded conductor PVC insulated complete all as specified and directed.
100
-
-
... More
Supply and fix 5 -in-1, 6 Amp,240V, SS Combined unit with box (surface type) with two fixing holes incl fixing rawal plug & screws complete all as specified and directed.
30
-
-
... More
Supply and fix 5 -in-1, 6/16 Amp,240V, SS Combined unit with box (surface type) with four fixing holes incl fixing rawal plug & screws complete all as specified and directed.
30
-
-
... More
Supply and fix in replacement ceiling rose, three terminal ISI marked surface bakelite suitable for batten fitting complete all as specified and directed.
50
-
-
... More
Supply and fix in replacement modular metal flush box of thickness 1.0 mm suitable for 12 modules 2 row complete all as specified and directed.
20
-
-
... More
Supply and fix in replacement modular metal flush box of thickness 1.0 mm suitable for 8 modules 2 row including making good the disturbed surface as specified and directed.
22
-
-
... More
Supply and fix in replacement modular metal flush box of thickness 1.0 mm suitable for 6 modules including making good the disturbed surface as specified and directed.
20
-
-
... More
Supply and fix in replacement modular metal flush box of thickness 1.0 mm suitable for 3 modules including making good the disturbed surface as specified and directed.
15
-
-
... More
Supply and fix in replacement modular metal flush box of thickness 1.0 mm suitable for 2/1 modules including making good the disturbed surface as specified and directed.
25
-
-
... More
Supply and fix in replacement decorative polycarbonate modular white frame for fixing of switches and cover plate suitable for 12 modules 3 row and blanking plate if any required for spare module complete all as specified and directed.
20
-
-
... More
All as per item No 101.00 here in before but 8 module single or double row as per site requirement complete all as directed by Engr in charge.
25
-
-
... More
All as per item No 101.00 here in before but 6 module complete all as specified and directed.
20
-
-
... More
All as per item No 101.00 here in before but 3 module complete all as specified and directed.
15
-
-
... More
All as per item No101.00 here in before but 1 or 2 module complete all as specified and directed.
25
-
-
... More
Supply and fix Distribution box MCB Protected socket with Plastic enclosure (Surface mounting) 20 Amp MCB DB BOX Combo DP including Plug top all as specified and directed.
50
-
-
... More
S&F for TP&N vertical load line DB double door with provision of MCCB as Incomer upto suitable 160 Amp, 415 volts 04 way, 50 Hz complete all as specified and directed. (Note: The cost of MCCB & MCBs shall be measured and paid under separate item)
3
-
-
... More
S&F for SP&N DB with 63 Amps rated bus bar, double door with 230 volts 8 way, 50 Hz complete all as specified and directed.
5
-
-
... More
Supply and fix MCB ,single pole 240 Volt, C curve 10 KA 5 to 32 Amps complete all as specified and directed.
70
-
-
... More
Supply and fix MCB, SPN, 240 Volt, C curve 10 KA , 20-32 Amps in existing DBs complete all as specified and directed.
18
-
-
... More
Supply and fix MCB ,SP,240 Volt, C curve 10 KA ,40 Amps complete all as specified and directed.
55
-
-
... More
Supply and fix MCB ,DP, 240 Volt, C curve 10 KA , 40/63 Amps complete all as specified and directed.
20
-
-
... More
Supply and fix MCB ,TPN,415 Volt, C curve 10 KA ,63Amps complete all as specified and directed.
10
-
-
... More
Supply and fix in replacement tamper proof single phase electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH including cable connection, proper sealing with barcode with PVC seal. The meter shall be fixed on existing steel boxes on wall complete all as specified and directed. Make:- Secure /L&T/BHEL (Note:- Old unserviceable meter will be deposited to E/M store yard)
25
-
-
... More
Supply and fix in replacement tamper proof three phase electronic meters temper proof LCD display with polycarbonate cover 415 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH including cable connection, proper sealing with barcode with PVC seal. The meter shall be fixed on existing steel boxes on wall complete all as specified and directed. Make:- Secure /L&T/BHEL (Note:- Old unserviceable meter will be deposited to E/M store yard)
15
-
-
... More
Supply and fix in replacement of off load Change over switch with enclosure 4 Pole, 300 Amps, 415 V , complete all as specific and directed.
2
-
-
... More
S&F in replecement energy efficient LED light fitting, slim LED panel, recessed mounting 2 ft x 2 ft made out of power coated CRCA sheet with acrylic diffuser, constant current output of electronic driver operating voltage range of 150 to 270 volts AC, PF0.95, high powder LEDs having efficiency of 100-120 lumins/watts, junction temparature less than 85 digree C and TH less than 12 % and CCT 6500K,, CRT90 suitable for 36 watt LED, LM 80 certified LM, pri wired in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose /connector etc and testing complete all as specified and directed.
20
-
-
... More
S&F in replecement energy efficient LED light fitting, slim LED panel, surface mounting
2 ft x 2 ft made out of power coated CRCA sheet with acrylic diffuser, constant current output of electronic driver operating voltage range of 150 to 270 volts AC, PF0.95, high powder LEDs having efficiency of 100-120 lumins/watts, junction temparature less than 85 digree C and TH less than 12 % and CCT 6500K, CRT90 suitable for 36 watt LED, LM 80 certified LM, pri wired in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose /connector etc and testing complete all as specified and directed.
20
-
-
... More
S&F in replacement LED 10 watt surface mounted downlight of size 125mm dia with white powder coated polycarbonate housing and pressure die cast heat sink having high efficiency complete incl connection with 1.5 Sqmm 2 core flexible copper cable
30
-
-
... More
S&F in replacement LED 15 watt surface mounted downlight of size 200mm dia with white powder coated polycarbonate housing and pressure die cast heat sink having high efficiency completeincl connection with 1.5 Sqmm 2 core flexible copper cable
55
-
-
... More
S&F in replacement energy efficient LED light fitting surface mounted 4' long, 20 watt, 240 volts, 50 hz made out of extrunded aluminium housing with acrylic diffuser, LM 80 certified LED, costant current out put of electronic driver of operating voltage 140v to 270v and temperature - 10 digree centigrade to 50 digree centigrade with ingress protection IP 20 duly pre wired with insulated copper wire, PF0.95 with efficiency 120 lumins/watt and TDH less than 10%, CRI 90 digree , CCT 6500 K in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose complete all as specified and directed.
450
-
-
... More
S&F sheet metal enclosure for DBs 16 Way single Pole and Neutral with acrylic double door having 200 Amps rated copper bus bar 240 Volts AC complete
4
-
-
... More
S&F sheet metal enclosure for DBs 12 Way single pole and neutral with acrylic double door having 200 Amps rated copper bus bar 240 Volts AC complete all as specified and directed.
3
-
-
... More
M&L for in renewal of sub main wiring 2x4.0 sqmm and 1x4 Sqmm earth wire PVC insulated FRLSH multistranded copper conductor ISI marked 1100 V grade in existing PVC concealed conduit or fixed in wall/floor,passing through wall/ceiling complete all as specified and directed.
62
-
-
... More
M&L for in renewal of sub main wiring 2x10 sqmm and 1x10 Sqmm earth wire PVC insulated FRLSH multistranded copper conductor ISI marked 1100 V grade in existing PVC conduit fixed in wall/floor,passing through wall/ceiling complete all as specified and directed.
120
-
-
... More
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to test point from earth electrode will be included in the rates quoted by the contractor) with following:-
(a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits)
(c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.Angle iron frame made of 40x40x4 mm angle iron for 30x30 cm PCC pit for holding the pit cover and Apply two coat of syntheticnenamel paint over one coat of red oxide zinc chrome primer on exposed steel surfaces and two coat of hot tar on embedded portion of steel surfaces
5
-
-
... More
M&L Galvanised iron strip 25x4mm buried in ground including necessay excavation & earth work in soft/loose soil and removal of excavated naterial n. exc 50m and depositing where directed complete all as specified and directed.
12
-
-
... More
S&F in replacement MCCB of 04 pole 400 amp, TPN, 50 KA (Ics=Icu=100%) microprocessor based with adjustable over current short circuit current with in bulk LCD display for trip cause alongwith tined copper spreader links, extended rotary handle, phase barrier (both side), Aux contact for on and trip indication complete all as specified and directed.
2
-
-
... More
S&F in replacement MCCB of 04 pole 250 amp, TPN, 36 KA (Ics=Icu=100%) thermal magnetic based with adjustable over current short circuit current with in bulk LCD display for trip cause alongwith tined copper spreader links, extended rotary handle, phase barrier (both side), Aux contact for on and trip indication complete all as specified and directed.
2
-
-
... More
S&F in replacement MCCB of 04 pole 160 amp, TPN, 25 KA (Ics=Icu=100%) thermal magnetic based with adjustable over current short circuit current with in bulk LCD display for trip cause alongwith tined copper spreader links, extended rotary handle, phase barrier (both side), Aux contact for on and trip indication complete all as specified and directed.
1
-
-
... More
S&F in replacement MCCB of 04 pole 100 amp, TPN, 16 KA (Ics=Icu=100%) thermal magnetic based with adjustable over current short circuit current with in bulk LCD display for trip cause alongwith tined copper spreader links, extended rotary handle, phase barrier (both side), Aux contact for on and trip indication complete all as specified and directed.
1
-
-
... More
S&F in replacement PVC conduit 25mm dia including fittings/accessories concealed in wall including cutting chasing and making good to disturb surfaces complete all as specified and directed.
15
-
-
... More
S&F in replacement of PVC Sheathed copper cable 1.5 Sqmm 3 core complete all as specified and directed.
30
-
-
... More
S&F in replacement of PVC Sheathed copper cable 2.5 Sqmm 3 core complete all as specified and directed.
90
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%