Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date5 Sep 2018
Closing Date1 Oct 2018
Tender Amount₹ 20,26,335 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as above in srl item No. 2.0 here in before but for one socket outlet point 5 amps on the same board.

56

-

-

... More
All as above in srl item No. 2.0 here in before but for one socket outlet point 5 amps on the independent board.

240

-

-

... More
All as per srl item no. 02 here-in-before but with 2.5 sq mm FRLS copper wire with 1.5 Sqmm FRLS copper earth wire for 15 Amp light point. Note : The point wiring for power point will not be mixed with light/fan point circuit or not in the same conduit pipe.

149

-

-

... More
M&L in replacement for Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC concealed conduit 25 mm dia with and including 4.00 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as directed.- Make of copper wire :-RR Cable/Havells/ Standard/ Polycab Note : 1. The conduit and conduit accessories shall be measured and paid as one unit. 2. The cost of earth wire is included in the quoted rates.

300

-

-

... More
M&L in replacement of switch piano flush type, single pole, one way, 5/6 Amps complete all as specified and directed. Make :- Anchor/cona/GM

481

-

-

... More
M&L in replacement of socket 2-in-1 2/3 pin, 5/6 Amps universal type.Make :- Anchor/cona/GM

84

-

-

... More
M&L in replacement of switch 16 Amp, single pole, one way complete all as directed. Make :- Anchor/cona/GM

196

-

-

... More
M&L in replacement socket 16 Amp multipurpose shuttered type, complete all as directed. Make :- Anchor/cona/GM

84

-

-

... More
Supply and fixing in replacement of LED tube light fitting, 22 watt. wall mounting type with and including all electric connections with two core PVC insulated, PVC sheathed copper conductor flexible cable. Make : Havells/Philips/CG/Syska Cat Part No-SSK-SQ 2201-22W.

200

-

-

... More
Material and labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 2 core ISI marked in service connections, suspended by insulating hanger (not more than 1 mtr apart) including all connections from main panel to main DB with thimbles of suitable size, including taking down of old unserviceble cable of any size complete all as directed.Make : Polycab / Havells/ RR Kabel

450

-

-

... More
Excavation in trenches in loose/soft soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out including forming bottom surface for laying LT cable as specified and directed at site by Engineer-in-Charge.

149.5

-

-

... More
Returning filling in soil including spreading, levelling, watering and well rammingin layers not exceeding 25 cm complete as specified and directed by the Engr-in-charge.

76.1

-

-

... More
Removing exccavated soil not exceeding 50 mtr and depositing wheredirected at a level not exceeding 1.5 mtr above the starting point complete as specified and directed by the Engr-in-charge.

73.4

-

-

... More
M&L for sand cushioning to under ground cable provided with layers of snad(8 cms deep before laying the cable and 15 cms deep after laying) complete allas specified and directed at site by Engineer-in-Charge.

60.4

-

-

... More
Supply and laying burnt bricks class - B for protection of cable complete all asspecified and directed at site.

6443

-

-

... More
Supply and fixing in replacement of LED security light luminaire 35/40 watt (white) pressure die cast aluminium housing with heat resistance toughned glass & including driver/transformer complete all as directed.Make:Philips/Havells/Syska. Cat Part No-SSK ST 40 W.

50

-

-

... More
Supply and fixing in replacement of street light fitting bracket, 1.5 mtr long made out of galvanized iron pipe of 40 mm dia size light grade complete with nut, bolts, washer etc inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as directed.

35

-

-

... More
Supply and fixing ceiling fan 1200mm sweep with step regulator 230 volt AC Make-Orient/Havells/CG complete all as specified & directed.

50

-

-

... More
Supply and fixing in replacement of MCB C Curve type, 10 kA, 10 to 32 Amp, Single Pole with over load and short circuit protection complete all as directed. Make : L&T / Legrand Lexic / Crabtree Xpro

112

-

-

... More
Supply and fixing in replacement of MCB C Curve type, 10 kA, 10 to 63 Amp, SPN with over load and short circuit protection complete all as directed. Make : L&T / Legrand Lexic / Crabtree Xpro

14

-

-

... More
Supply and fixing for MCB DB SPN 4 way single door type with 200 Amps rated bus bar complete all as specified & directed. Make : L&T / Legrand Lexic / Crabtree Xpro

14

-

-

... More
Supply and fixing in replacement of MCCB Incomer fabricated distribution board double door vertical type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating surface mounting, TPN 4 way, 415 volts with bus bar rating 250 Amps, dust and vermin proof and IP 42 - IK 09 protection with and incorporation of MCB & upto 200 Amps MCCB complete all as directed. Make : L&T / Legrand Lexic / Crabtree Xpro Note : 1. The cost of removing old wooden/metal box and making good of surface as original i.e. brick work, plastering, white washing etc is included in quated rate.

7

-

-

... More
Supply and fixing in replacement of MCCB 4 p[ole 415 volt of rating 200 Amps, 36 kA, over load and short circuit protection complete all as directed. Make : L&T / Legrand Lexic / Crabtree Xpro

7

-

-

... More
M&L for earthing complete with GI earth plate electrode 600 mm x 600mm x 6mm thick burried directly in ground not less than 2.25 mtrs below ground level, with top edge of the plate not less than 1.5 mtrs deep below normal ground level, connected to galvanised earth wire 4mm by means of bolts, nuts check nuts to earth test point including necessary PCC 1:2:4 type B-1 pit, cover frame, GI pipe 15mm dia light grade for protection of earthing lead and GI pipe 20 mm dia for watering pipe with funnel, wire mesh, salt, charcoal dust and excavation complete all as directed.

46

-

-

... More
M&L for Sub main wiring with 2 run of 1.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC concealed conduit 25 mm dia with and including 1.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as directed.- Make of copper wire :-RR Cable/Havells/ Polycab. Note : 1. The conduit and conduit accessories shall be measured and paid as one unit. 2. The cost of earth wire is included in the quoted rates.

450

-

-

... More
M&L for Sub main wiring with 2 run of 2.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC concealed conduit 25 mm dia with and including 1.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as directed.- Make of copper wire :-RR Cable/Havells/ Polycab. Note : 1. The conduit and conduit accessories shall be measured and paid as one unit. 2. The cost of earth wire is included in the quoted rates.

400

-

-

... More
M&L for Sub main wiring with 2 run of 4.0 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC concealed conduit 25 mm dia with and including 2.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as directed.- Make of copper wire :-RR Cable/Havells/ Standard. Note : 1. The conduit and conduit accessories shall be measured and paid as one unit. 2. The cost of earth wire is included in the quoted rates.

450

-

-

... More
Ditto all as item ser No 30 above but in replacement

420

-

-

... More
M&L for Modular switch 6 Amp, 1 way, 1 module size complete all as directed.Make :- Anchor/ Cona/ SSK

100

-

-

... More
M&L for Modular socket 6 Amp, 2/3 pin, universal type, 2 module size complete all as directed.Make :- Anchor/ Cona/ SSK

100

-

-

... More
M&L for Modular switch 16 Amp, 1 way, 1 module size with indicator lamp complete all as directed. Make :- Anchor/ Cona/ SSK

65

-

-

... More
M&L for Modular socket 16 Amp multipurpose shuttered type, 2 module size with indicator lamp complete all as directed. Make :- Anchor/ Cona/ SSK

65

-

-

... More
M&L for Ceiling rose, insulated body, 3 terminal, 240 volts, 5 Amps with and including pressed steel powder coated MS sunken box of suitable size, covered with & including 3 mm thick bakelite, laminated hylem sheet top cover and making good surface as original by plastering and whitewash/ colour/ distemper etc complete all as directed.Make : Anchor Penta / SSK touch. Note : The cost of MS sunken box and bakelite sheet is included in the quoted rate.

100

-

-

... More
Diitto all Ser No 35 above but in replacement

285

-

-

... More
M&L for Rigid non metallic PVC conduit (ISI marked) medium grade, 2 mm thick, 20 mm dia (external) inclusive of MS junction/terminal boxes inclusive of all fittings such as tees, bends, elbow, reducers, bell mouth tube ends etc and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc for sub main/TV/telephone wiring etc complete all as directed.Make : Finolex/ AKG / Harsh.

300

-

-

... More
Diitto all Ser No 37 above but in replacement

350

-

-

... More
S & F of fresh air fan 250 mm sweep size, plastic body type including self cosing louver and making all electric connections complete all as directed. Make: Havells/ Bajaj/ Usha

50

-

-

... More
S & F of Exhaust fan 380mm sweep size, including self cosing louver and making all electric connections and make hole in walls complete all as directed. Make: Havells/ Bajaj/ Usha

50

-

-

... More
S&F of Single pole and netural enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps complete all as specified and directed. Make: Anchor Cat part No.- 98488

65

-

-

... More
Supply and fix Water heater storage type with copper tank, electric,capacity 25 litres.BEE 5 star rated including all electric and water connections all as specified and directed. Make :- Bajaj/ Havells/ CG

35

-

-

... More
Supply and fix Water heater storage type with copper tank, electric,capacity 50 litres.BEE 5 star rated including all electric and water connections all as specified and directed. Make :- Bajaj/ Havells/ CG

30

-

-

... More
S & F GI Tubes, `Medium grade' galvanised, size 20 mm bore dia with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. Make:- Prakash Surya/ Jindal/ TATA.

310

-

-

... More
S & F GI Tubes, `Medium grade' galvanised, size 25 mm bore with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. Make:- Prakash Surya/ Jindal/ TATA.

410

-

-

... More
Supply and fixing gun metal gate valve ISI Marked with iron wheel head screwed both ends for iron pipes of 20 mm bore Make :- Bir/ Sant

35

-

-

... More
All as per above here-in-before but size 25 mm dia

30

-

-

... More
S & F Plug type bib taps cast iron screw for iron pipe of 20 mm dia complete all as specified and directed by Engr-in-Charge.

65

-

-

... More
S & F GI Nipple suitable for HDPE water tank (minimum 6' to 12') ISI marked complete all as specified

130

-

-

... More
S & F of GI Tee of size 20 to 25 mm ISI marked complete all as specified

65

-

-

... More
S & F of GI Socket of size 20 to 25 mm ISI marked complete all as specified

130

-

-

... More
S & F of GI Elbow of size 20 to 25 mm ISI marked complete all as specified

130

-

-

... More
S & F of GI Union of size 20 to 25 mm ISI marked complete all as specified

130

-

-

... More
S & F of Top plug 15 Amps incl all connections complete all as specified. Make : - Anchor/ Cona/ SSK

65

-

-

... More
S & F CP connections armoured type 15mm size with PTMT nuts of length 600mm complete all as specified.

130

-

-

... More
Desmantling of old damaged solar water heating system spares including collector, checking of electric panel system, testing of all connections electric as well as water connections and removal of old U/S collector tubes all as specified and directed. (a) Solar Collectors not less than 2 Sqmeter BIS approved copper round shape tubes, selectively coated to meet the energy requirement for attaining the pool temp in winter/cloudy/ average clear suny days. Note: No of collectors shall be as per existing design .

17

-

-

... More
S & F in replacement of Heat exchanger tube type with titanium tubes to transfer Heat, equivalent of 1/5th of the daily load per hour with 10 degree contigrate temperature difference in primary and secondary system.

65

-

-

... More
S & F in replacement of Interconnecting piping of size 15 mm dia existing for the solar collector all as specified and directed.The piping shall be of GI medium grade & fitting as per BIS specification. The minimum size of pipe shall be as per design but it should not be less than 50mm dia. The pipe shall be insulated with 50mm thick rock wool/mineral wool of 48 Kg/Cum density & have a Vapour barrier, chicken wire mesh and 24 gauge aluminium cladding. The cladding shall be suitable for out door applications.

150

-

-

... More
S & F in replacement of Interconnecting piping of size 20 mm dia existing for the solar collector all as specified and directed.The piping shall be of GI medium grade & fitting as per BIS specification. The minimum size of pipe shall be as per design but it should not be less than 50mm dia. The pipe shall be insulated with 50mm thick rock wool/mineral wool of 48 Kg/Cum density & have a Vapour barrier, chicken wire mesh and 24 gauge aluminium cladding. The cladding shall be suitable for out door applications.

150

-

-

... More
S & F in replacement of Interconnecting piping of size 25 mm dia existing for the solar collector all as specified and directed.The piping shall be of GI medium grade & fitting as per BIS specification. The minimum size of pipe shall be as per design but it should not be less than 50mm dia. The pipe shall be insulated with 50mm thick rock wool/mineral wool of 48 Kg/Cum density & have a Vapour barrier, chicken wire mesh and 24 gauge aluminium cladding. The cladding shall be suitable for out door applications.

200

-

-

... More
S & F in replacement of Interconnecting piping of size 40 mm dia existing for the solar collector all as specified and directed.The piping shall be of GI medium grade & fitting as per BIS specification. The minimum size of pipe shall be as per design but it should not be less than 50mm dia. The pipe shall be insulated with 50mm thick rock wool/mineral wool of 48 Kg/Cum density & have a Vapour barrier, chicken wire mesh and 24 gauge aluminium cladding. The cladding shall be suitable for out door applications.

180

-

-

... More
S & F in replacement of Differential temperature controller (DTC) with display the digital read out of temperature at the two sensor points

15

-

-

... More
S & F in replacement of Auto / Manual selector as per existing complete all as specified and directed.

10

-

-

... More
S & F in replacement of MCB for pumps as per existing complete all as specified and directed.

50

-

-

... More
S & F in replacement of Time totalizer as per existing complete all as specified and directed.

8

-

-

... More
S & F in replacement of Auto/manual indicating lamps as per existing complete all as specified and directed.

30

-

-

... More
S & F in replacement of Pumps selector switch with system either on auto or manual mode as per existing complete all as specified and directed.

12

-

-

... More
S & F in replacement of Start/stop switch for the pumps when it is running on manual mode as per existing complete all as specified and directed.

12

-

-

... More
S & F in replacement of Contactor 'No" type as per existing complete all as specified and directed.

12

-

-

... More
S & F in replacement of Over load relay as per existing design condition at site complete all as specified and directed.

12

-

-

... More
S & F in replacement of Gun metal gate valves of suitable size shall be provided for pump & other equipments, isolation for working maintenance & normal working as per existing complete all as specified and directed. Note: The size & quantity of valves, flow meter, electrical operated, control valves, stainer etc are as per existing design condition.

25

-

-

... More
S & F in replacement of Non return valves of size 20 mm dia complete all as specified and directed.

15

-

-

... More
S & F in replacement of flow meter sensor as per existing complete all as specified and directed.

15

-

-

... More
S & F in replacement of electrically operated control valve per existing complete all as specified and directed.

15

-

-

... More
S & F in replacement of stainer per existing complete all as specified and directed.

15

-

-

... More
S & F in replacement of wire/cable to be incorporated in the work as per existing for the following: (i) Electric back up (ii) Electrical wiring as per existing size complete all as specified and directed

300

-

-

... More
Material and labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 3.0 core ISI marked in service connections, suspended by insulating hanger (not more than 1 mtr apart) including all connections from main panel to main DB with thimbles of suitable size, including taking down of old unserviceble cable of any size complete all as directed.Make : Polycab/Havells

350

-

-

... More
PCC/ Brick work for grouting of structural support etc as per site requirement complete all as specified and directed.

2

-

-

... More
M & L in replacement of insulation with minimum of 50mm thick of rock wool/mineral wool of 48 Kg/Cum density and covered with vapour barrier chicken wire mesh and GI sheet of 24 Gauge thicknessall as specified and directed.

600

-

-

... More
M & L for chicken wire mess of size 12.5mmx 0.51mm (24SWG) hexagonal construction for cage covering of all solar water heater toughned glass plate including fixing, supporting mtrl and tightned with nut & bolts complete all as specified and directed.

850

-

-

... More
S & F in replacement of PC falanged suitable for solar water heater complete all as specified and directed.

35

-

-

... More
S & F in replacement of hose clamp suitable for solar water heater complete all as specified and directed.

50

-

-

... More
S & F in replacement of gaskets suitable for solar water heater complete all as specified and directed.

50

-

-

... More
S & F of Nuts & bolts suitable for solar water heater complete all as specified and directed.

7

-

-

... More
S & F in replacement of safety valve of size 20 mm dia suitable for solar water heater tank complete all as specified and directed.

50

-

-

... More
S & F in replacement of elbow of size 20 mm diasuitable for solar water heater complete all as specified and directed.

52

-

-

... More
S & F in replacement of reducer suitable for solar water heater complete all as specified and directed.

50

-

-

... More
S & F in replacement of nipple of size 20 mm dia 6" long suitable for solar water heater complete all as specified and directed.

51

-

-

... More
S & F in replacement of sockets of size 20 mm dia suitable for solar water heater complete all as specified and directed.

50

-

-

... More
S & F in replacement of tee of size 20 mm dia suitable for solar water heater complete all as specified and directed.

50

-

-

... More
Servicing of solar water heater tanks & collectors with chemical suitable for solar water heater complete all as specified and directed.

17

-

-

... More
S & F in replacement of glass of solar water heater as per existing size all as directed.

18

-

-

... More
S & F in replacement of solar water heater elements of 2 KW capacity as per existing size all as directed.Make :- Theeta/Dasspass

50

-

-

... More
S & F in replacement of solar water heater elements of 3 KW capacity as per existing size all as directed.Make :- Theeta/Dasspass

40

-

-

... More
S & F in replacement of solar water heater elements of 6 KW capacity as per existing size all as directed.Make :- Theeta/Dasspass

35

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.