Military Engineer Services Tender

... More
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date18 Feb 2025
Closing Date11 Mar 2025
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking down of existing unserviceable micropressor magnum controller and M & L charges for installation of Microprocessor Magnum Controller alongwith Software, installation and controlling arrangement including thimbles control wire etc complete suitable for 50TR AC Plant of Voltas complete all as specified and directed.

1

-

-

... More
Replacement of old unserviceable filter from AHU small & large both and S&F New fillter complete, all as specified and as directed.

9

-

-

... More
Supply, installation, testing and commissioning in replacement of auto air vent valve of 15 mm dia complete all as specified and directed.

4

-

-

... More
M&L for repair of hot water generator of capacity 30 KW in four banks complete with one slave bank controlled by semi conductor rectifier & other necessary controls, electrical panels etc complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacement including testing of chiller water flow valve with electric control and other works as required at site to make the system functional incl welding as required at site complete all as specified and as directed.

2

-

-

... More
M&L for servicing/ descaling of hot water generator upto 30KW 3 phase 415 Volts including replacement of burnt heaters and calibration testing of all functional with including replacement of any defective parts.

2

-

-

... More
Cleaning of the evaporator coil of 50 TR capacity central air conditioning plant with cleaning agent by forced feed method to remove the unwanted dust formed over the cooling coil fins without disturbing the mounting of the coils and greasing to the AHU blower bearing and tightening of all fasteners etc complete all as specified and as directed.(The descaling and cleaning works to be carried out by authorised skilled person by the service dealer or from the Manufacturer)

3

-

-

... More
Supply and fix thermostatic expansion valve suitable for 50 TR capacity central air conditioning plant including cutting and bracing including taking down existing unserviceable thermostatic expansion valve complete all as specified and directed. (Make: Sporlan/ Indfos/ Danfos)

2

-

-

... More
Dismantling the compressor of 50 TR from installed position after disconnecting the suction and discharge refrigerant line, open the compressor for carrying out the repairs/ replacement of unserviceable parts, setting of valve reeds, valve plates, bearings, loading and unloading mechanism, pistons with rings, oil seals, oil pumps etc after carrying out necessary lathe work for grinding and polishing the worn out seatings/ housing of the compressor body and assembling with essential minor parts i.e. split pins, nuts, bolts, washers, rubber rings etc and fixing in its position including testing for proper functioning complete all as specified and directed.

3

-

-

... More
Material and labour for pumping down the refrigerant for re use from the gas line to the chillar unit, removing the existing insulation at the shell and tube chiller and carefully dismantling the refrigerant pipe lines, chilled water circulation pipe lines with valves on both inlet and outlet side. Cut open the chiller in a dust free environment with proper tools and equipments and replacement of the damaged existing copper gas pipe line with new annealed copper pipe line of the existing diameter with minimum 0.5mm thick fixing in original position including necessary brazing/ welding and fixing for smooth functioning. Re-assembling the chiller unit with proper Air tight sealed for leak proof by ensuring filling with Nitrogen gas for 72 hours pressure test and covered the complete chiller with nitrate insulation with minimum 19mm thick before connecting, testing and commissioning complete. Note- Opening and assembling should be done by the authorised dealer and all the spares should be provided through OEM.

1

-

-

... More
Disconnecting, dismantling and strip opening of the existing air handling unit of any description and in any position and of capacity of 50 TR for overhauling and servicing, including taking out existing shaft, blower drum, pulley and de-humidifier pump etc of air handling unit, checking thoroughly serviceability of the parts, fixing the serviceable parts in positiion, replacement of the defective/non functional/unserviceable parts/spares, reassembling, commissioning, fixing in position and testing of the air handling unit on full load for its smooth and trouble free operation complete all as specified.

6

-

-

... More
Disconnecting & dismantling of existing unserviceable cooling tower, FRP type 50 TR capacity of any description & in any position including dimantling all old connected part/ filters, like motor, FRP casing basin, PVC filling, MS/GI pipe line, sluice valve, stop valve, steel structure frame etc. Servicing/ Overhauling, cleaning, oiling/ greasing and fixing of serviceable parts with new parts, reassembling the cooling towers and connected parts/ items fixed in position for connected to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-charge.

2

-

-

... More
M&L for overhauling of pump and motor 7.5 to 10 HP capacity by opening up and cleaning of all parts such as impeller , rotor, stator, fan cover, greasing including replacing all unserviceable / damaged part like impeller, bearing, bush,seal,shaft,coupling, machine work etc and reconnecting back and testing complete all as specifiedand directed.

2

-

-

... More
M&L for overhauling of pump and rewinding of electric motor with super enamelled copper winding wire of existing gauge of capacity 5 to 7.5 HP by opening up and cleaning of all parts such as impeller , rotor, stator, fan cover, greasing including replacing all unserviceable/damaged part like impeller, bearing, bush,seal,shaft,coupling,machine work etc and reconnecting back and testing complete all as specifiedand directed.

2

-

-

... More
Descalling and cleaning of 50 TR condenser water cooled by circulating the diluted chemical HCL by forced feed method not than 6hrs duration by opening of the end covers of the condenser brushing the tubes thoroughly,re-fixing back the end cover of the condesers with 3mm thick rubber gasket and testing complete to maintaining desired discharged pressures for water cooled condenser as directed by EIC complete all as specified and as directed.

6

-

-

... More
M&L for charging of Refrigerant R-407C complete including testing after completion complete all as specified and directed.

70

-

-

... More
M&L for charging of Refrigerant R-410 complete including testing after completion complete all as specified and directed.

30

-

-

... More
Supply & filling of compressors oil with testing for complete all as specified and as directed.

35

-

-

... More
M & L for Finding out leakage in the system, leakage repair including brazing cost, Nitrogen Testing and recommissioning of 50 TR water cooled Chiller complete all as specified and directed.

1

-

-

... More
Matereial and labour for rewinding of AHU motor with super enamelled copper winding wire of existing gauge including testing after repair complete all as specified and directed.

1

-

-

... More
M&L for fixing all the accessories including Butterfly Valve 150mm dia including the application of nitrile rubber insulatioin over the valves complete

1

-

-

... More
M&L for fixing all the accessories including Butterfly Valve 100mm dia including the application of nitrile rubber insulatioin over the valves complete

1

-

-

... More
Material and labour including installation of V belt of size A42 complete.

1

-

-

... More
Material and labour including installation of V belt of size A43 complete.

1

-

-

... More
Material and labour including installation of V belt of size A46 complete.

1

-

-

... More
Material and labour including installation of V belt of size A48 complete.

1

-

-

... More
Material and labour including installation of V belt of size A49 complete.

1

-

-

... More
S&F in repair water pressure gauge along with stop cock and fixing arrangement suitable for water pressure 0-16/20 kg/sq cm complete all as soecified and as directed.

2

-

-

... More
S&F in repair industarial type thermometer of range 0-50 degree centigrade for AC plant as per sample complete all as specified and as directed.

2

-

-

... More
S&F suction pressure gauge suitable for suction pressure 0-250 PSI complete all as specified and as directed.

1

-

-

... More
S&F discharge pressure gauge suitable for discharge pressure 0-500 PSI complete all as specified and as directed.

1

-

-

... More
S&F in repair timer electronic type complete all as specified and as directed.

1

-

-

... More
S&F in repair single phase preventer complete all as specified and as directed.

2

-

-

... More
S&F in repair power contractor of MNX - 25 complete all as specified and as directed.

2

-

-

... More
S&F in repair of LP switch complete all as specified and as directed.

2

-

-

... More
S&F in repair of HP switch complete all as specified and as directed.

2

-

-

... More
S&F in repair of refrigerant copper pipe 15mm complete all as specified and as directed.

25

-

-

... More
S&F in repair of refrigerant copper pipe 12 mm complete all as specified and as directed.

25

-

-

... More
Checking, servicing, preventive maintenance, cleaning (Dry and Wet), inspection and testing of window type Air condineer of capacity 1.5/2 Ton of invertor/ nonivector type or any modal and make at site in Multi story buildings as per OEM guideline for safety and performance by means chekcing operation performance parameters, cleaning of blower, condenser fan, cleaning or replacing the air filters, cleaning the condeser and evaporator coils, checkiing the refrigerant level and testing for leakage and topping off refrigerant level, inspecting and tightening electrical connections, lubricating moving parts, checking thermostate calibration, checking the PCB controler cards and capacitor * Remote control handset in and including anti corrosive coating blue/gold fin on condenser and evaorator coils complete all as specified and as directed.

70

-

-

... More
All as per item Ser No 42.00 above but split type/cassette type AC, Inverternon inverter type AC 1.5/2.0/3.0 ton

275

-

-

... More
M&L in replacement of Fan Motor of AC (Window/ Split Type) 1.5 TR Capacity of existing Make and required Size to suit existing AC including taking out the unservice-able Fan Motor from the AC, complete all as specified and as directed.

25

-

-

... More
All as per ser item No. 44 here-in-before but AC (Window/Split Type). 2.0 TR Capacity

20

-

-

... More
M&L for Rewinding of Fan Motor of AC 1.5/2 TR Capacity, (Window/Split Type) of any Make with Super Enameled Copper Wire of appropriate Gauge and Quantity including taking out burnt Winding, complete all as specified and as directed.

40

-

-

... More
M&L in replacement Air circular Blower Fan Motor of AC (Split Type), 1.5 TR/2.0/3.00TR Capacity including taking out unser-viceable Air circular Blower Fan Motor complete all as specified and as directed.

25

-

-

... More
M&L in replacement Air Filter suitable of AC (Window type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Air Filter from AC complete all as specified and as directed.

20

-

-

... More
M&L in replacement Air Filter suitable of AC (Split type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Air Filter complete all as specified and as directed.

35

-

-

... More
M&L in replacement Capacitor Running 36 mfd – 45 mfd suitable for new/star rated for AC (Window/Split Type) 1.5 TR/2.0 TR Capacity and of any make including taking out unserviceable Capacitor from AC complete all as specified and as directed.

55

-

-

... More
M&L in replacement Capacitor Starting 80 mfd – 120 mfd suitable for old ones AC (Window/Split Type) 1.5 TR/2.0 TR Capacity and of any make including taking out unserviceable Capacitor from AC complete all as specified and as directed.

40

-

-

... More
M&L in replacement Fan Motor Blades AC (Window/Split type) 1.5/2.0 TR capacity including taking out unserviceable Blades of Fan Motor from AC complete all as specified and as directed.

30

-

-

... More
M&L in replacement Fan Motor Capacitor 4 mfd of suitable for new/star rated AC (Window/Split Type) 1.5/2.0TR capacity including taking our unserviceable Fan motor capacitor from AC complete all as specified and as directed.

120

-

-

... More
M&L Fan Motor in replacement Capacitor 6 mfd suitable for old ones AC (Window/Split Type) 1.5/2.0TR capacity including taking our unserviceable Fan motor capacitor from AC complete all as specified and as directed.

80

-

-

... More
M&L in replacement Front Plastic Grill (as per Sample) of AC (Window type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Front Plastic Grill from AC all as per existing and complete all as specified and as directed.

20

-

-

... More
M&L in replacement Front Plastic Grill for inner unit (as per Sample) of AC (Split type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Front Plastic Grill from AC all as per existing complete all as specified .

20

-

-

... More
M&L in replacement Runner for air blower motor of AC (split type) AC 1.5/2.00TR capacity (As per sample or as per site requirement) complete all as specified and as directed.

25

-

-

... More
M&L Single Pole Contactor 25A Capacity, MR 11W type as approved suitable for AC (Split Type) including taking out unserviceable Single Pole Contactor all as specified and as directed.

20

-

-

... More
M&L Selector Switch of AC (Window/Split Type) 1.5 TR/2.0/3.0 TR Capacity including taking out unserviceable Selector Switch from AC complete all as specified and as directed.

20

-

-

... More
M&L Selector Switch Knob of AC (Window/ Split Type) 1.5 TR/2.0/3.00 TR Capacity including taking out unserviceable Selector Switch Knob from AC complete all as specified and as directed.

20

-

-

... More
M&L Starting Relay of AC (Window/Split Type) 1.5 TR/2.0/3.00TR Capacity including taking out unser-viceable Starting Relay from AC complete all as specified and as directed.

30

-

-

... More
M&L Strainer with Capillary Tube of AC Window/ Split Type) 1.5 TR/2.0/3.0 TR Capacity (including taking out unserviceable Strainer with Capillary Tube from AC complete all as specified and as directed.

25

-

-

... More
M&L Thermostat Switch of AC (Window/Split Type) 1.5 TR/2.0/3.0 TR Capacity including taking out unserviceable Thermostat Switch from AC complete all as specified and as directed.

80

-

-

... More
S&F cooling coil suitable for window type room AC 1.5/2 ton including taking out unserviceable cooling coil of capacity 1.5/2 ton.as per sample.

10

-

-

... More
S&F Condensing coil suitable for window type AC 1.5/2 ton including taking out unserviceable Condensing coil of capacity 1.5/2 ton

10

-

-

... More
S&F Condensing coil suitable for split type AC including taking out unserviceable Condensing coil of capacity 2 ton.

20

-

-

... More
S&F cooling coil suitable for split type AC including taking out unserviceable cooling coil up to capacity 2 ton.

20

-

-

... More
S&F Indoor unit suitable for 1.5 TR split type AC including taking out unserviceable Indoor unit complete all as specified and directed.

3

-

-

... More
S&F outdoor unit suitable for 1.5 TR split type AC with compressor including taking out unserviceable outdoor unit complete all as specified and directed.

3

-

-

... More
S&F Indoor unit suitable for up to 2 TR split type AC including taking out unserviceable Indoor unit complete all as specified and directed.

2

-

-

... More
S&F outdoor unit suitable for up to 2 TR split type AC with compressor including taking out unserviceable outdoor unit complete all as specified and directed. Note for item 68 to 71 :- Old unserviceable indoor/Outdoor unit shall be deposited in MES yard.

2

-

-

... More
Suuply & Fix in replacement of Hermitacally sealed compressor for split/ window type AC capacity 1.5 Ton complete all as specified and directed.

12

-

-

... More
All same as per ser item No. 72 here-in-before but of split/ window type AC capacity 2.0 Ton.

10

-

-

... More
Taking down/up defective AC 1.5 TR Capacity (Window/Split Type), Transportation from MES Store Yard/Site to Workshop for any type of defect and back after repair from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas R22/R410 including re-connection of Electric Connections, functioning AC complete in all respect and Testing, complete all as specified and as directed.

15

-

-

... More
All as per Item No. 74 here–in–before, but AC 2.0 TR Capacity (Window/Split Type).

10

-

-

... More
M&L PCB with remote for window type AC up to 2 Ton capacity including taking out unserviceable PCB complete all as specified and directed .

30

-

-

... More
M&L PCB with remote for Split type AC 2 Ton capacity including taking out unserviceable PCB complete all as specified and directed .

35

-

-

... More
M&L PCB & motherboard with remote complete set for Inverter Split type AC up to 2 Ton capacity including taking out unserviceable PCB complete all as specified and directed .

10

-

-

... More
Taking down defective/ unserviceable PCB & motherboard of AC 1.5 TR Capacity Split Type, transportation from MES Store Yard/Site to Workshop and back after complete repair of PCB and motherboard for smooth functioning including re-fixing and testing for proper functioning of AC complete all as specified .

60

-

-

... More
Taking down defective / unserviceable PCB & motherboard of AC 2 TR Capacity Split Type, transportation from MES Store Yard/Site to Workshop and back after complete repair of PCB and motherboard for smooth functioning including re-fixing and testing for proper functioning of AC complete all as specified .

25

-

-

... More
M&L in replacement Remote of AC ( Window/Split Type) 1.5/2.0 TR capacity (As per sample or as per site requirement) all as specified and as directed.

25

-

-

... More
S&F in replacement wiring kit suitable for 1.5 to 2.0 ton capacity AC complete including taking out unserviceable wiring kit all as specified and directed.

30

-

-

... More
S&F in replacement gas charging pin valve complete including taking out unserviceable pin valve all as specified and directed.

40

-

-

... More
Taking out window type AC of any capacity complete unit from any height/ any floor up to four storey building and shifting to another location in the same or other building in the complex including refixing of the unit complete all as specified and directed.

10

-

-

... More
Taking out split type AC of any capacity complete indoor and outdoor unit from any height/ any floor up to four storey building by including pumping down the gas into the compressor by controlling the suction and discharge valves , disconnecting the suction and dischagre copper piping and shifting to another locatiion in the same or other building in the complex including refixing of the unit complete all as specified and directed.

10

-

-

... More
Supply and charging the gas refrigerant R22 (including refrigerant) of window type AC upto 2 ton capacity including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitorgen pressure to ensure leak proof gas circulator system flushing out the nitrogen gas complete all as specified and directed.

85

-

-

... More
All as per ser item No. 86.00 here-in-before but R- 32 for split type AC up to 2 TR capacity complete.

190

-

-

... More
All same as per item No 86.00 above here-in-before but cassatte type AC upto 4 TR capacity complete.

50

-

-

... More
All same as per item No 86.00 above here-in-before but VRF unit 8 TR capacity complete.

15

-

-

... More
S&F in replacement of casing of window type AC including company fitted condensing & cooling coil complete including PCB except compressor complete

12

-

-

... More
M&L for replacement of split valve ¼” for split AC up to 2.00 ton capacity complete all as specified and directed.

25

-

-

... More
All as per ser item No. 91 here-in-before but 1/2"complete all as specified and directed.

25

-

-

... More
S&F in replacement compressor shut off valve 3/8" for split AC up to 2 ton capacity complete all as specified and directed.

20

-

-

... More
S&F in replacement compressor shut off valve 5/8" for split AC up to 2 ton capacity complete all as specified and directed.

20

-

-

... More
S & F in replacement of electrolyte grade copper tubing of size 1/4" suitable for any type of split type AC including synthetic rubber foam complete all as specified and directed. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building.

100

-

-

... More
All as per ser item No. 95 here-in-before but size 1/2"complete all as specified and directed.

75

-

-

... More
All as per ser item No. 95 here-in-before but size 3/8"complete all as specified and directed.

60

-

-

... More
All as per ser item No. 95 here-in-before but size 5/8"complete all as specified and directed.

60

-

-

... More
S&F in replacement PVC conduit 20mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from ACs of Bldgs upto 5 (five) storey complete all as specified and directed.

100

-

-

... More
S&F in replacement PVC conduit 25mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from Acs of Bldgs upto 5 (five) storey complete all as specified and directed.

50

-

-

... More
S&F in replacement of synthetic rubber foam for insulation for refrigerant copper piping of existing size 1/4" to 5/8" internal dia for split type AC upto 2 Ton complete all as specified and directed Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building.

100

-

-

... More
S&F in replacement Hermatically Sealed compressor for 40/80 Ltrs capacity water cooler including bracing the sunction and discharge lines complete all specified and dircted.

2

-

-

... More
S&F in replacement Hermatically Sealed compressor for 60/120 Ltrs capacity water cooler including bracing the sunction and discharge lines complete all specified and dircted.

2

-

-

... More
S&F in replacement AC stand suitable for out door split AC unit up to cap of 2 ton capacity necessary 40x40x6mm angle iron including fixing arrangements like welding, fabrication and nuts & bolts etc upto six stories building complete all as specified and as directed .

10

-

-

... More
S&F in replacement reverse valve system made of copper for heating option suitable for 1.5/2.0 ton split / window type AC including appropriate Gas Charging complete all as specified and as directed.

5

-

-

... More
Taking down Defective Water Cooler 40/80 litre Capacity, Transportation from MES Store Yard/Site to Workshop and back for any type of defect including re-fixing /reinstall -ing, Testing, connecting the same after complete repair for smooth functioning including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas, complete all as specified and as directed.

2

-

-

... More
M&L for servicing of water cooler of any capacity including cleaning of water cooler from inside and outside with potassium permanaganates, servicing of colling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed.

7

-

-

... More
Supply and charging the gas in the water cooler of any make and capacity up to 150 ltr capacity including testing and detecting leakage if any with nitrogen gas and vaccum the sytem after rectification of all leakages complete all as specifie and directed.

6

-

-

... More
S&F in replacement thermostat switch suitalbe for water cooler of any make & size complete all as specified and directed.

8

-

-

... More
S&F in replacement starting relay/over load relay suitalbe for water cooler of any make & size complete all as specified and directed.

8

-

-

... More
S&F in replacement defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed.

8

-

-

... More
M&L for preparation of old painted surfaces of water cooler by removing old deteriorated paid, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray painting.

3

-

-

... More
S&F in replacement fan motor ISI marked suitalbe for water cooler as per existing capacity upto 150 ltrs of any make complete all as specified and directed.

3

-

-

... More
S&F in replacement of condenser fan of any make suitable for water cooler upto 150 ltrs capacity complete all as specified and directed.

3

-

-

... More
S&F in replacement 15 mm dia PVC connection of length upto 600mm with PTMT nuts on both ends complete all as specified and directed.

20

-

-

... More
S&F in replacement condenser coil suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed.

2

-

-

... More
S&F in replacement steel/aluminium waste water tray suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed.

3

-

-

... More
M&L for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside repair/replacement of defective/unserviceable parts, replacing of fan kit, motor, water pump and connected accessories complete all as specified and directed. Note : Unserviceable parts requires replacement shall be measured and paid separately as supply only under respective items of this schedule.

50

-

-

... More
M&L for painting of desert cooler capacity upto 4000 Cfm with two coats of approved synthetic enamel paint inside & outside including fan/fan blade/brackets after scrapping the rust,peal of paint and preparation of surface complete all as specified and directed by Engr-in-Charge. Note : The rates are inclusive of taking down cooler from any height, removal to workshop for painiting and refixing in position after painting.

42

-

-

... More
S&F in replacement of desert cooler sub mersible water pump complete with electric motor single phase 230 volts 50Hz including lead, connecting & testing complete all as specified and directed.

35

-

-

... More
S&F in replacement desert cooler fan motor,copper wound suitable for upto 450mm sweep SP 230 volts 50HZ including legs, rubber bush nuts/bolts for fixing of fan motor complete with connection & testing complete all as specified and directed.

25

-

-

... More
S&F in repalcement of commercial ply wood BWP 4mm thick ISI marked for desert cooler of any size to close the opening between desert cooler grill and window complete all as directed.

5

-

-

... More
S&F in replacement plug top 3 pin 5 Amps complete all as specified and directed.

15

-

-

... More
S&F in replacement plug top 3 pin 15 Amps complete all as specified and directed.

10

-

-

... More
S&F in replacement motor capacitor 2.5/3.15/4 mfd complete all as specified and directed.

50

-

-

... More
S&F in replacement front grill made of MS complete with air guide vanes suitable for desert cooler of capacity 4000 Cfm complete all as specified and directed.

10

-

-

... More
S&F in replacement of body without side panels made out of galvanised iron sheets of of 22 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare all as directed .

4

-

-

... More
S&F in replacement of side panels of desert cooler body of 22 gauge of existing size & shape duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare all as directed.

30

-

-

... More
S&F in replacement of float valve assembly with PTMT ferrule 15 mm dia and PVC ball valve suitable for water cooler up to 150 ltrs capacity and desert cooler upto 4000 Cfm complete all as directed by Engr-in-Charge.

40

-

-

... More
S&F new wood wool pad,(Khus Khas) set of three covered by GI wire mesh suitable for desert cooler including taking out the old unserviceable existing pad complete all as specifed & directed

50

-

-

... More
M&L for replacement of aluminium multi wing Fan blade, best quality as per existing type and size suitable for of desert cooler complete all as specifed and directed

15

-

-

... More
Taking out old unsv thermostat and S&F new thermostat of approved make and suitable size & model for the following :-

-

-

-

... More
Auto 'D' thermostat No 1027 with knob for Deep freezer / refrigerator or equivalent

2

-

-

... More
Thermostat No 2064 with knob for water cooler or equivalent

10

-

-

... More
Taking out old unserviceable relay unit and supply and fix new relay kit (OLP + LMS relay or box type) as per sample for refrigerator complete all as specified and directed.

1

-

-

... More
Taking out old unserviceable relay kit and S&F new relay kit as per sample for water cooler, No 412Y/512Y or equivalent complete all as specified and directed.

5

-

-

... More
Taking out old unserviceable relay of any type and S&F new potential box type relay/PTC relay of suitable model for split type AC/deep freezer complete all as specified and directed.

50

-

-

... More
Taking out old unserviceable/broken knobs & S & F new knobs for AC/desert cooler of any capacity complete all as specified and directed.

20

-

-

... More
M&L in replacement of unserviceable/leakage cooling coil complete of existing size/ model refrigerator complete all as specified and directed.

1

-

-

... More
M&L in replacement of unserviceable condenser complete of existing size/ model refrigerator complete all as specified and directed.

1

-

-

... More
M&L in replacement of broken freezer door complete with casing and lock nut as per sample for refrigerator of any capacity complete all as specified and directed.

1

-

-

... More
M&L in replacement of vegetable tray complete suitable for existing model of refrigrator of any capacity complete all as specified and directed.

1

-

-

... More
M&L in replacement of chiller tray complete suitable for existing model of refrigerator of any capacity complete all as specified and directed.

1

-

-

... More
M&L in replacement of metal shelf powder coated suitable for existing model of refrigerator of any capacity complete all as specified and directed.

1

-

-

... More
M&L in replacement of bulb pintype/thread type suitable for existing model of refrigerator of any capacity complete all as specified and directed.

1

-

-

... More
M&L in replacement of broken door panel gasket complete suitable for existing model of refrigeratior of any capacity complete all as specified and directed.

1

-

-

... More
M&L in replacement of burnt out condenser fan motor, single shaft suitable for any capacity, single phase, 230 V , AC, for water cooler complete all as specified and directed.

5

-

-

... More
M&L for checking of drain water tray for leakage & getting the same repaired by soldering all the sides of the tray including making proper provision for fitting of grating to the tray to make it functional as directed.

5

-

-

... More
M&L in replacement of UNSV push cock, 15 mm dia for water cooler complete all as specified and directed.

5

-

-

... More
M&L in replacement of UNSV stop cock, 15 mm dia for water cooler complete all as specified and directed.

5

-

-

... More
S&F fan blade (As per sample) in replacement for water cooler/ deep freezer of any capacity complete all as specified and directed.

5

-

-

... More
Taking out old unserviceable/broken float valve and S & F new float valve complete for water cooler of any capacity complete all as specified and directed.

5

-

-

... More
S & F in replacement PVC connection 15mm bore with PTMT nuts of following sizes:-

-

-

-

... More
600mm

5

-

-

... More
900mm

4

-

-

... More
1200mm

1

-

-

... More
Taking out old broken PVC flexible drain outlet pipe & S & F new drain outlet pipe 32/40mm dia complete for water cooler of any capacity as directed.

5

-

-

... More
M&L for repair/replacement of bottom portion of the water cooler of any make & capacity with MS angle iron of suitable size as per existing, including welding/brazing with MS sheet 1.6mm thick at the base of water cooler for mounting of compressor, blower motor, etc complete all as directed.

5

-

-

... More
M&L for replacement of old wornout/burnt wiring of water cooler/ deep freezer by using copper conductor wire PVC sheathed of suitable size and length complete all as directed.

5

-

-

... More
All as per Item No 159.00 above but for split type / window A/C of any capacity .

14

-

-

... More
S&F fan blade (As per sample) in replacement for split type AC/Desert Cooler of any capacity complete all as specified and directed.

35

-

-

... More
M&L for taking out old broken drain outlet pipe of any type attached to indoor unit of split type AC & S & F new drain outlet PVC pipe 20mm dia from indoor unit to nearest suitable drain outlet for split type AC of any capacity as directed.

50

-

-

... More
S & F new door handle as per sample in replacement of old broken handle of Deep Freezer as directed

1

-

-

... More
S & F new door gasket in replacement of old unserviceable door gasket of Deep Freezer of any capacity complete all as specified and directed.

1

-

-

... More
M&L in replacement of air filter made out of nylon wire mesh moulded in plastic complete suitable for existing old filter's size and shape, as directed for 1.5/2 TR capacity of split type AC complete all as specified and directed.

17

-

-

... More
S&F MCB, SP 20- 32 Amps,10 KA ,230 V, 'C'series in replacement of old damage/broken MCB SP complete all as specified and directed.

5

-

-

... More
S&F MCB, SPN, 40 Amps,10 KA ,230 V, 'C'series in replacement of old damage/broken MCB SPN complete all as specified and directed.

2

-

-

... More
S & F MCB TPN, 415 Volts, 40/63 Amps,10 KA ,230 V, 'C'series complete all as specified and directed.

2

-

-

... More
M&L for servicing the deep freezer unit completely for trouble free working and satisfactory performance by means of cleaning each part of the machine carefully, greasing/oiling every moveable part, cleaning the condenser and cooling coil complete with the help of wire brush, soda wash and pressure air through blower and cleaning the machine for better working as directed.

2

-

-

... More
M&L for replacement of caster wheels (set of four) complete for Air cooler/desert cooler of any size and capacity all as directed.

15

-

-

... More
M&L for replacement of switch assembly complete for Air cooler/desert cooler of any size and capacity all as directed.

20

-

-

... More
M&L for removing of old unserviceable stabilizer of capacity 4KVA from the site, transporting it to the workshop, replacement of unserviceable spares such as control transformer, main transformer, voltmeter, relay, control board, etc as required and getting back the stabilizer at site and fiixing at the same position and checking it for its workablility as specified and directed

5

-

-

... More
M&L for removing of old unserviceable stabilizer of capacity 5 KVA from the site, transporting it to the workshop, replacement of unserviceable spares such as control transformer, main transformer, voltmeter, relay, control board, etc as required and getting back the stabilizer at site and fiixing at the same position and checking it for its workablility as specified and directed

5

-

-

... More
M&L for replacement of old unserviceable stabilizer of capacity 5 KVA with new voltage stablizer of same capacity alongwith complete spares of stablizer such as control transformer, main transformer, voltmeter, relay, control board, etc and fiixing at the same position including electrical connection complete and checking it for its workablility as specified and directed.

10

-

-

... More
M&L for replacement of old unserviceable stabilizer of capacity 4 KVA with new voltage stablizer of same capacity alongwith complete spares of stablizer such as control transformer, main transformer, voltmeter, relay, control board, etc and fiixing at the same position including electrical connection complete and checking it for its workablility as specified and directed. Note for ser item No. 1 to 175 :- 1. The contractor shall provide and deploy Skilled technician with helpers(as directed by GE / Engineer-in-charge) and contractor's site supevisor/site engineer shall report at 0900 hrs daily upto 1700 hrs excluding Sunday & holiday to collect the complaints / job card for attending emergent complaints of any capacity & type of Air Conditioning, water cooler, desert cooler, deep freezer, freeze ,ceiling fan/ exhaust fan/ geysers of any size including carrying out minor repairs as required to Make the system in order / functional including replacing minor part complete all as specified and directed by JE E/M / Engineer-in-charge (within 48 hrs) 2. The complaints shall be attended with in 48 hrs. If the complaints is/are not attended /not completed on the same day (except repair/ replacement of major items like replacement of cooling coil, condensing coil , fan motor etc.) recovery will be done as follows (a) After 48 Hrs, Rs - 1000.00 Per complaint per day. The decesion of GE on recovery against penalty shall be final and binding and No representation whatsoever shall be entertained. 3. The technicians for repair of summer appliances can be called during non-working days/hrs (i.e. Sunday, Holidays & after working hrs) for any vital complaint at DRDO area. 4. The contractor has to produce job card duly signed by user & JE E/M to Engineer-in-charge.

10

-

-

... More
S&F in repair end termination joint 11 KV indoor type, end termination heat shrinkable of size 3x 120 to 185 sqmm including thimbling, nut/bolts & washers, HV insulating tape etc. complete all as specified and as directed.

2

-

-

... More
S&F in repairs straight through joint 11 KV heat shrinkable of size 3x 120 to 185 sqmm including thimbling, nut/bolts & washers, HV insulating tape etc. complete all as specified and as directed.

3

-

-

... More
Taking proper shutdown & Isolate the LT electric supply and taking out the ACB of capacity upto 1250 Amps of any make and type and servicing of all minor/major parts of the ACB by cleaning isolating contact moving parts,removing dust particle from the bus bar chamber spout gear mechanism, repair to motor charge spring mechanism,tightening of all nut & bolts of entire component as directed , inserting the ACB, testing the complete LT electric supply and putting on supply on load including Calibration of relay of 1.1KV LT ACBs installed at various sub stn at KWC area complete all as specified and directed. complete all as specified & directed. Note:- All cleaning /testing equipment/ safety equipment material shall be provided by the contractor and rate for the same shall be demed to be included in quoted rates.

8

-

-

... More
Supply and laying in replacement PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 core including suitable size aluminium lugs properly crimpled with crimping tools including testing complete all as specified and directed

60

-

-

... More
All as per item srl No 179.00 abocve but area 300 Sqmm 3.5 core

120

-

-

... More
All as per item srl No 179.00 above but area 185 Sqmm 3.5 core

70

-

-

... More
All as per item srl No 179.00 above but area 120 Sqmm 3.5 core

120

-

-

... More
All as per item srl No 179.00 above but area 70 Sqmm 3.5 core

70

-

-

... More
Supply and laying in replecement XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 120 Sqmm 3 core including testing complete all as specified & directed

20

-

-

... More
All as per item srl No 184.00 above but area 185 Sqmm 3 core

20

-

-

... More
Supply and laying GI pipe light grade in replecement of 100mm dia laid in trenches for protection of UG cable complete all as specified & directed

12

-

-

... More
All as per item srl No 186.00 above but 80mm dia complete all as specified and directed.

20

-

-

... More
Taking proper shutdown & Isolate the HT electric supply and taking out the trolley of VCB/OCB HT 11KV 630 to 1250 Amp of any make and type and servicing of all minor/major parts of the VCB by cleaning isolating contact moving parts,removing dust particle from the bus bar chamber spout gear mechanism, repair to motor charge spring mechanism,tightening of all nut & bolts of entire trolley component as directed , inserting the trolley, testing the complete HT electric supply and putting on supply on load including Calibration of relay of 11KV HT VCBs installed at various sub stn at KWC area complete all as specified and directed. complete all as specified & directed. Note:- All cleaning /testing equipment/ safety equipment material shall be provided by the contractor and rate for the same shall be demed to be included in quoted rates.

15

-

-

... More
Supply only replacement of vaccum interrupter complete all as specified and directed.

2

-

-

... More
Supply only replacement of big gear and small gear with all fixing arrangement complete all as specified and directed.

1

-

-

... More
Supply only replacement of closing spring assembly complete all as specified and directed.

1

-

-

... More
Supply only replacement of tripping spring assembly complete all as specified and directed.

2

-

-

... More
Supply only replacement of charging motor cut off limit switch complete all as specified and directed.

2

-

-

... More
Supply only in replacement of spring charging handle motorized mechanism of VCB complete all as specified and directed.

2

-

-

... More
Supply only in replacement of push button bracket assembly complete all as specified and directed.

2

-

-

... More
Supply only in replacement of bus bar support insulator 75 mm dia including all fixing accessories complete suitable for VCB/HT Bus bar chamber all as specified and directed.

4

-

-

... More
Supply only in replacement of bus bar barrier as per existing (set of three) with nuts bolts complete all as specified and directed.

3

-

-

... More
Supply only in replacement of toggle switch for space heater complete with all accessories all as specified and directed.

2

-

-

... More
Supply only in replacement of Charged/Discharged indication assembly complete all as specified and directed.

6

-

-

... More
M&L in replacement of control wiring for panel with 2.5 Sqmm copper conductor FRLSH cable including proper laying with the help of locking device as per manufacturer instruction complete all as directed

17

-

-

... More
Taking down repairable potential transformer of HT VCB 11 KV/ 110 V of any make, opening & dismentling the complete unit and refixing after carry out the following repairs/replacement :- (a) Rewinding of transformer as per existing gauge and pattern. (b) Cleaning and servicing of the PT. (c) Replacement of wornout nuts/bolts and other minor parts including HRC Fuse. (d) Soldering / tightening of loose connections. (e) Replacement of potential transformer oil having dielectric strength upto 50 KV. (f) Painting of outer portion of PT with synthetic enameled paint of grey colour of approved make. (g) Testing of the PT's for proper functioning to the entire satisfaction of the Engineer- in-charge

1

-

-

... More
S&F in replacement of potential transformer of HT VCB 11 KV/110 V of any make complete all as specified and as directed

2

-

-

... More
S&F in replacement of 11 pin anti pumping relay 110V DC complete all as specified and directed.

5

-

-

... More
S&F in replacement of bottom terminal with jaw contact complete all as specified and directed.

1

-

-

... More
S&F in replacement of top terminal with jaw contact complete all as specified and directed.

2

-

-

... More
S&F in replacement of space heater 230V AC 80W complete with all accessories all as specified and directed.

5

-

-

... More
S&F in replacement of thermostat complete with all accessories all as specified and directed.

2

-

-

... More
S&F in replacement of PT epoxy female bushing suitable for R-Y-B phase complete all as specified and directed.

2

-

-

... More
S&F in replacement of PT epoxy male bushing suitable for R-Y-B phase complete all as specified and directed.

1

-

-

... More
S&F in replacement of PT fuse 11 KV complete all as specified and directed.

2

-

-

... More
Dehydration and filtration of transformer oil with proper dehydration machine to achieve dielectric strength between 45 to 60 KV including testing/recording of dielectric strength result before and after of dehydration complete all as specified and as directed.

2250

-

-

... More
Supply and topping up transformer oil having dielectric strength not less than 60 KV complete all as specified and directed.

220

-

-

... More
Taking shut down from main substation and drain out the transformer oil and to be collected in barrel by opening the transformer cover of capacity 400 to 500 KVA by unscrewing the nuts/bolts and washers and kept in safe custody and reuse the same, and checking any type of leakage from both HT and LT side including cleaning the sludge etc depositing in the core and tank by using soft brushes and clean with old transformer oil, refilling of transformer oil including refixing of top cover including nut/bolts etc and testing the input & output voltage and adjustment of the voltage through tape changer if required complete to the entire satisfaction of Engineer- in-charge.

2

-

-

... More
All as per srl item No 213.00 above but of capacity 630 KVA

1

-

-

... More
S&F in repair HT bushing 11KV suitable for 400 to 630 KVA Transformer including brass rod complete with gasket as per matching to existing all as specified and directed.

1

-

-

... More
S&F in repair LT bushing 11KV suitable for 400 KVA to 630 KVA transformer including brass rod complete with gasket as per matching to existing all as specified and directed.

2

-

-

... More
S&F in repair head gasket sheet 6mm thick suitable for Transformer 400 KVA to 500 KVA capacity including replacement of nuts, bolts, washers including necessary T&P required at site complete all as specified and directed.

1

-

-

... More
S&F in repair head gasket sheet 6mm thick suitable for Transformer 630 KVA capacity including replacement of nuts, bolts, washers including necessary T&P required at site complete all as specified and directed.

1

-

-

... More
S&F in repair Dehydrating breather assembly complete with silica gel grains in the breather assembly suitable for transformers 400 KVA to 630KVA as per matching to existing complete all as specified and directed

8

-

-

... More
S&F in repair water temperature gauge analog type complete with all accessories as per matching to existing complete all as specified and directed

2

-

-

... More
S&F in repair Oil temperature gauge analog type complete with all accessories as per matching to existing complete all as specified and directed

2

-

-

... More
S&F in repair voltmeter digital type for voltage range of (0-500V) including all accessories and wiring complete all as specified and directed.

2

-

-

... More
S&F in repair ammeter digital type for current range of 0-1000 Amps as per matching to existing including all accessories and wiring complete all as specified and directed.

1

-

-

... More
S&F in repair power factor meter digital type for frequency range (45-65 Hz) as per matching to existing one including all accessories and wiring complete all as specified and directed.

3

-

-

... More
S&F in repair three phase over current earth fault relay MC-61 as per matching to existing one including all accessories and wiring complete all as specified and directed.

2

-

-

... More
S&F in repair three phase overcurrent earth fault relay MC-61A as per matching to existing one including all accessories and wiring complete all as specified and directed.

2

-

-

... More
S&F in repair LED type Indicating lamp of voltage AC/DC set of RYB, as per matching to existing complete all as specified & directed.

12

-

-

... More
S&F in repair Current Transformer as per matching to exisitng complete all as specified and directed.

3

-

-

... More
S&F in repair Multifunctional meter complete all as specified and directed

2

-

-

... More
S&F in repair VCB Power Pack unit 24 Volt DC 7 AH with battery bank for backup including panel as per matching to exisitng complete all as specified and directed

2

-

-

... More
Excavation in trenches in soft/loose soil not exceeding 1.5m depth & not exceeding 1.5m in width over energised LT cables for carrying out brick work for preparation of cable duct including for taking out and relaying of LT Cables complete all as specifed & directed

115

-

-

... More
Excavation in trenches in hard/dense soil not exceeding 1.5m depth & not exceeding 1.5m in width over energised LT cables for carrying out brick work for preparation of cable duct including for taking out and relaying of LT Cables complete all as specified & directed

5

-

-

... More
Supply & laying dry fine sand for cushioning of underground cable laid in trenches/duct complete all as specified and as directed. Note : Punned thickness shall be measured.

31

-

-

... More
Supply and laying in trenches burnt brick sub class 'B' standard size for cable protection keeping width of the brick parallel to the length of the cable all as specified and directed.

5

-

-

... More
Supply and laying un-reinforced factory made precast concrete cable cover , class HV, type 1, flat size-300x180x40 mm complete all as specified and directed

90

-

-

... More
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick as in soft/loose soil complete all as specified and directed.

62

-

-

... More
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level and not exceeding 1.5 mtr above the starting point complete all as specified and directed.

41

-

-

... More
S&F in replacement MCCB of 04 pole 250 amp, TPN, 36 KA (Ics=Icu=100%) thermal magnetic based with adjustable over current short circuit current with in bulk LCD display for trip cause alongwith tined ccupper spreader links, extended rotary handle, phase barrier (both side), Aux contact for on and trip indication complete all as specified and directed.

1

-

-

... More
S&F in replacement MCCB of 04 pole 400 amp, TPN, 50 KA (Ics=Icu=100%) microprocessor based with adjustable over current short circuit current with in bulk LCD display for trip cause alongwith tined ccupper spreader links, extended rotary handle, phase barrier (both side), Aux contact for on and trip indication complete all as specified and directed.

1

-

-

... More
S&F in replacement MCCB of 03 pole 630 amp, TP, 50 KA (Ics=Icu=100%) microprocessor based with adjustable over current short circuit current with in bulk LCD display for trip cause alongwith tined ccupper spreader links, extended rotary handle, phase barrier (both side), Aux contact for on and trip indication complete all as specified and directed.

1

-

-

... More
S&F in replacement MCCB of 03 pole 250 amp, TP, 35 KA (Ics=Icu=100%) microprocessor based with adjustable over current short circuit current with in bulk LCD display for trip cause alongwith tined ccupper spreader links, extended rotary handle, phase barrier (both side), Aux contact for on and trip indication complete all as specified and directed.

1

-

-

... More
S&F in replacement MCCB of 03 pole 200 amp, TP, 35 KA (Ics=Icu=100%) microprocessor based with adjustable over current short circuit current with in bulk LCD display for trip cause alongwith tined ccupper spreader links, extended rotary handle, phase barrier (both side), Aux contact for on and trip indication complete all as specified and directed.

1

-

-

... More
S&F in replacement MCCB of 03 pole 160 amp, TP, 35 KA (Ics=Icu=100%) microprocessor based with adjustable over current short circuit current with in bulk LCD display for trip cause alongwith tined ccupper spreader links, extended rotary handle, phase barrier (both side), Aux contact for on and trip indication complete all as specified and directed.

1

-

-

... More
S&F in repair Capacitor Bank MPP-H, 5 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.

2

-

-

... More
S&F in repair Capacitor Bank MPP-H, 10 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.

3

-

-

... More
S&F in repair Capacitor Bank MPP-H, 20 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.

4

-

-

... More
S&F in repair Capacitor Bank MPP-H, 25 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.

5

-

-

... More
Supply and laying GI pipe light grade size 40 mm dia fixed on wall/laying in trench including all connected fitting/acessories including taking old unserviceable complete all as specified and directed

20

-

-

... More
M&L in replacement of heat shrinkable straight through jointing kit for LT 1.1 KV XLPE cable 185 to 630 sqmm 3.5 core including all accessories required

6

-

-

... More
M&L in replacement of heat shrinkable straight through jointing kit for LT 1.1 KV XLPE cable 70 to 150 sqmm 3.5 core including all accessories required

6

-

-

... More
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to test point from earth electrode will be included in the rates quoted by the contractor) with following:- (a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.Angle iron frame made of 40x40x4 mm angle iron for 30x30 cm PCC pit for holding the pit cover and Apply two coat of syntheticnenamel paint over one coat of red oxide zinc chrome primer on exposed steel surfaces and two coat of hot tar on embedded portion of steel surfaces

8

-

-

... More
M&L Galvanised iron strip 25x4mm buried in ground including necessay excavation & earth work in soft/loose soil and removal of excavated naterial n. exc 50m and depositing where directed.

30

-

-

... More
Supplying and laying synthetic Rubber insulated mats for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety. The upper surface having small anti skid aberration marks to avoid slippery effect and lower surface is plane of size 2m x 1m x 2mm thick for voltage upto 3.3 KV complete all as specified and as directed.

15

-

-

... More
Supplying and laying synthetic Rubber insulated mats for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety. The upper surface having small anti skid aberration marks to avoid slippery effect and lower surface is plane of size 2m x 1m x 2.5mm thick for voltage upto 11 KV complete all as specified and as directed.

10

-

-

... More
M&L MS chequred plate of suitable size for cable duct cover 6mm thick and earth pit cover all as specified and directed.

705

-

-

... More
Supply only Electrical insulation HT tape of 3/4"width of 30 feet length Etylene Propylene backing highly comfortable to wrap snugly over most any shape streches up 100 percent to provide avoid moisture, resistant insulation tape of Make-Scotch.

14

-

-

... More
Supply only Fix CRC 2-23 Electrical equipment (contact) cleaner spray used for prevent electronic malfunction equipment caused by water penetration, humidity, corrosion etc and of 500ml can complete all as specified and directed.

6

-

-

... More
Supply and Fix earth pit chamber alongwith cover of Polymer, FRP Pit cover of heavy high grade polypropelene for high stress and starin level of size 225x300x195mm complete all as specified and directed.

7

-

-

... More
S&F ACP retro sign board of size 1.5x1.1 Mtr using retro reflective high intensity prismatic reflective sheeting. The back ground of board is Blue Colour with white border and writing letter, numbers white colour mentioning the HT/LT substation Details, and Single line Schematic diagram of substation. Retro sign board shall be pasted on 3mm thick ACP sheet. The board shall be fixed on Wall including fixing of fastners, nuts, bolts, washer etc complete all as directed.

2

-

-

... More
Removing and replacing the old unserviceable lead acid battery of size 12 Volt, 42 AH of reputed make including charging all as specified as directed.

12

-

-

... More
S&F LED flood light with pressure die cast aluminium housing 150 Watt completed with connection including taking down old unserviceable complete all as specified and directed.

12

-

-

... More
S&F LED flood light with pressure die cast aluminium housing 200 Watt completed with connection including taking down old unserviceable complete all as specified and directed.

8

-

-

... More
Design, fabrication, assembling, wiring, supply installation, testing and commissioning in replacement of LT panel, suitable for indoor installation, factory fabricated out of CRCA sheet steel 2mm for non-load bearing members and 3.15mm for load bearing members in cubicle formation, compartmentalized, from 3b construction & IP-65 in acc. with IEC 60529 protection, free standing floor mounted, dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and / or flats wherever necessary with extensible type TPN aluminum alloy bus bars of high conductivity,DMC/SMC with supports with short circuit withstand capacity of 31 MVA for 1 sec.Panel shall have a common alluminium earth bar with 2 nos. earth stud. 3 mm thick cable gland plates shall be provided on top as well as at the bottom of the panels with anti-condensation space heater. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 Nos. earthling terminals shall be provided for all distribution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system duly internal wiring with pvc insulated FRLS multistranded copper conductor cable of suitable sizeand copper thimble etc.. Lifting hooks shall also be provide din case of large panels. Approval shall be taken for panel in the form of shop drawings before fabrication. Galvanized hardware's with zinc passivation shall be used in fabrication of panels in and including of taking out old us panel. Panel shall be consisting with following:-

1

-

-

... More
Incomer : 1000 Amps, 50KA, 4P EDO type Microprocessor based Air Circuit Breaker with ON/OFF/TRIP indicating lamps with MCB's and over current, short circuit and earth fault releases - 2 No. Bus coupler : 1000 Amps, 50KA, 4P EDO type Microprocessor based Air Circuit Breaker with ON/OFF/TRIP indicating lamps with MCB's and over current, short circuit and earth fault releases - 1 No. Bus-Bar : 2500 Amp, 50 KA, 3 Phase and Nutral Aluminum bus bars of high conductivity electrolytic quality aluminum alloy with colored heat shrinkable insulated sleeve.-1 Set. Instruments : Multifunction Meter including CT's of suitable size- 1 set. RYB phase indicating lamps LED type controlled by, MCB-1 Set Outgoing : 630 Amp 3P MCCB,35kA with RYB phase indicating lamps LED type controlled by, MCB - 4 Nos. 250 Amp 3P MCCB,25kA with RYB phase indicating lamps LED type controlled by, MCB - 4 Nos. Note: * All MCCB above 200A shall have microprocessor release unit with s/c, o/c & e/f protection. ( ICS as 100% ICU ) * All MCCB up to 200A shall be Thermal agnatic release unit with s/c & o/c protection.( ICS as 100% ICU) * All MCCB/MPCB shall be digital VAF Meter with CT's, LED type ON,OFF & TRIP indicating lamps and operating handle. * All MCB shall be 10kA with 'C' Curve . * All MPCB shall be Type '2' Co-ordination and having s/c, o/c & s/f protection .

-

-

-

... More
Design, fabrication, assembling, wiring, supply installation, testing and commissioning in replacement of LT panel, suitable for outdoor installation, factory fabricated out of CRCA sheet steel 2mm for non-load bearing members and 3.15mm for load bearing members in cubicle formation, compartmentalized, from 3b construction & IP-65 in acc. with IEC 60529 protection, free standing floor mounted, dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and / or flats wherever necessary with extensible type TPN aluminum alloy bus bars of high conductivity,DMC/SMC with supports with short circuit withstand capacity of 31 MVA for 1 sec.Panel shall have a common copper earth bar with 2 nos. earth stud. 3 mm thick cable gland plates shall be provided on top as well as at the bottom of the panels with anti-condensation space heater. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 Nos. earthling terminals shall be provided for all distribution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system duly internal wiring with pvc insulated FRLS multistranded copper conductor cable of suitable sizeand copper thimble etc.. Lifting hooks shall also be provide din case of large panels. Approval shall be taken for panel in the form of shop drawings before fabrication. Galvanized hardware's with zinc passivation shall be used in fabrication of panels in and including of taking out old us panel. Panel shall be consisting with following:-

1

-

-

... More
Incomer : 350 Amps, 50KA, 4P EDO type Microprocessor based MCCB with ON/OFF/TRIP indicating lamps with MCB's and over current, short circuit and earth fault releases - 1 No. 320 Amps, 50KA, 4Pon load chagnge over - 1 No. Bus-Bar : 900 Amp, 50 KA, 3 Phase and Nutral Aluminum bus bars of high conductivity electrolytic quality aluminum alloy with colored heat shrinkable insulated sleeve.-1 Set. Instruments : Multifunction Meter including CT's of suitable size- 1 set. RYB phase indicating lamps LED type controlled by, MCB-1 Set Outgoing : 125 Amp 4P MCCB,25kA with RYB phase indicating lamps LED type controlled by, MCB - 2 Nos. 100 Amp 4P MCCB,25kA with RYB phase indicating lamps LED type controlled by, MCB - 02 Nos Note: * All MCCB above 200A shall have microprocessor release unit with s/c, o/c & e/f protection. ( ICS as 100% ICU ) * All MCCB up to 200A shall be Thermal agnatic release unit with s/c & o/c protection.( ICS as 100% ICU) * All MCCB/MPCB shall be digital VAF Meter with CT's, LED type ON,OFF & TRIP indicating lamps and operating handle. * All MCB shall be 10kA with 'C' Curve . * All MPCB shall be Type '2' Co-ordination and having s/c, o/c & s/f protection

-

-

-

... More
Supply & fixing onload change over switch of 630 amps 415 V with suitable enclosure mounting on wall including fiting accessories complete all as specified and directed.

1

-

-

... More
S&F alluminium sector lugs (long barrel type) for HT connection of size upto 150 sqmm 3 core complete all as specified and directed.

15

-

-

... More
S&F alluminium sector lugs (long barrel type) for HT connection of size 185 to 400 sqmm 3 core complete all as specified and directed.

20

-

-

... More
S&F alluminium sector lugs (long barrel type) for HT connection of size 500 to 630 sqmm 3 core complete all as specified and directed.

15

-

-

... More
S&F alluminium sector lugs (short barrel type) for LT connection of size up to 50 sqmm 3.5 core complete all as specified and directed.

25

-

-

... More
S&F alluminium sector lugs (short barrel type) for LT connection of size 70 to 95 sqmm 3.5 core complete all as specified and directed.

27

-

-

... More
S&F alluminium sector lugs (short barrel type) for LT connection of size 120 to 185 sqmm 3.5 core complete all as specified and directed.

30

-

-

... More
S&F alluminium sector lugs (short barrel type) for LT connection of size 240 sqmm 3.5 core complete all as specified and directed.

35

-

-

... More
S&F alluminium sector lugs (short barrel type) for LT connection of size 300 sqmm 3.5 core complete all as specified and directed.

36

-

-

... More
S&F alluminium sector lugs (short barrel type) for LT connection of size 400 sqmm 3.5 core complete all as specified and directed.

40

-

-

... More
S&F alluminium sector lugs (short barrel type) for LT connection of size 630 sqmm 3.5 core complete all as specified and directed.

30

-

-

... More
Material and labour for shifting of 500 KVA Transformer from one location to another location in the complex permises including diconnecting at both exiting site and laying at new site with all connections, checking thoroughly serviceability of the parts, fixing the serviceable parts in positiion, replacement of the defective/non functional/unserviceable parts/spares, reassembling, commissioning, fixing in position and testing for its smooth and trouble free operation complete all as specified and directed

1

-

-

... More
Material and labour for shifting of 315 KVA Transformer from one location to another location in the complex permises including diconnecting at both exiting site and laying at new site with all connections, checking thoroughly serviceability of the parts, fixing the serviceable parts in positiion, replacement of the defective/non functional/unserviceable parts/spares, reassembling, commissioning, fixing in position and testing for its smooth and trouble free operation complete all as specified and directed

1

-

-

... More
Material and labour for shifting of VCB 630 Amps from one location to another location in the complex permises including diconnecting at both exiting site and laying at new site with all connections, checking thoroughly serviceability of the parts, fixing the serviceable parts in positiion, replacement of the defective/non functional/unserviceable parts/spares, reassembling, commissioning, fixing in position and testing for its smooth and trouble free operation complete all as specified and directed

2

-

-

... More
Taking shutdown from sub-station & Painting and Servicing of LT feeder panel boards complete with removal of the dust, tightening of electrical connections, replacement of burnt nut/bolts with washers, replacement of connections wires as per power load requirement, including insulation tapping complete all as specified and directed by Engineer-In-charge.

8

-

-

... More
Taking shutdown from LT panel & Servicing of Distribution Boards any type complete with removal of the dust, tightening of electrical connections, replacement of burnt nut/bolts with washers, replacement of connections wires as per power load requirement, including insulation tapping complete all as specified and directed by Engineer-In-charge.

20

-

-

... More
Taking proper shutdown , disconnecting the LT and HT electric main from transformer of any capacity, removing the transfomer of any capacity from pole/structure/ platform shifting to authorised workshop after draining out the transformer oil at site, dismantling and disconnecting damaged HT/LT coil to facilate necessary repairs, rewinding/reconditioning reassembling the tranformer, bringing back to the site, taking out dehydrated old trasformer oil and connecting with existing electrical system of HT and LT including testing complete all as specified and directed. (winding wire and othe items mentioned in schedule will be measured and paid separately)

1

-

-

... More
Rewinding/reinsulation of LT/HT coils of any size and type of transformer including cleaning the brunt out insulating materials, brazing and rewinding with appropriate turns and size of super enamelled DPC insulated copper winding wire of appropriate gauge including filling insulation paper etc all as specified and directed by engr-in-chage Note :- (i) Weight, number of turns, gauge, insulation of winding wire shall be as per OEM. (ii) Work of rewinding shall be carried out through OEM or their authorised vender only.

169

-

-

... More
Supply and testing 11 KV VCB Trolley having 18.5 KA 1250 Amp Vacuum Interrupter (06 nos) and retrofit in existing make of VCB (ITE/VCB/776)/HT Panel installed at DRDO Substation to maintain reliable electric supply at KWC Area complete all as specified and directed.

1

-

-

... More
M&L for bringing cable testing van (fault locator) for detecting the location of the fault in the LT/HT cable 1.1 KV of any size complete all as specifiec and directed.

7

-

-

... More
M&L in replacement of heat shrinkable straight through jointing kit for LT 1.1 KV XLPE cable 185 to 630 sqmm 3.5 core including all accessories required

5

-

-

... More
M&L in replacement of heat shrinkable straight through jointing kit for LT 1.1 KV XLPE cable 70 to 150 sqmm 3.5 core including all accessories required

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.