Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 46,840Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Ge/h-60/2024-25 Special Repair To Bldg No P 05 And P 06 At Static Wksp At Ahrr Under Ge E/m Rr Hospital Delhi Cantt 10
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684975_1Tender No
GE/H-60/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M&L for 15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finished even and fair without using extra cement, complete all as specified and directed by Engr-in-Charge.
80
-
-
M&L for 15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4, finished even and fair without using extra cement, complete all as specified and directed by Engr-in-Charge.
100
-
-
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over and including applying 1-2mm thick cement base wall care putty, complete all as specified and directed by Engr-in-Charge.
80
-
-
M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior grade weather proof paint over and including 1-2mm thick cement base wall care putty, complete all as specified and directed by Engr-in-Charge.
100
-
-
M&L for complete removal of existing treatment from the old decorated plastered surfaces of walls and applying two coats of oil bound distemper over and including applying 1-2mm thick cement base wall care putty, complete all as specified and directed by Engr-in-Charge.
600
-
-
M&L for complete removal of existing treatment from the old decorated plastered surfaces of walls and applying two coats of exterior grade weather proof paint over and including 1-2mm thick cement base wall care putty, complete all as specified and directed by Engr-in-Charge.
500
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed by Engr-in-Charge.
320
-
-
M&L 15mm thick screed bed or bedding layer in cement mortar (1:6) for laying floor finishes, complete all as specified and directed by Engr-in-Charge.
300
-
-
M&L 10 mm thick screed bed or bedding layer in cement mortar (1:4) to receive wall tiles, complete all as specified and directed by Engr-in-Charge.
20
-
-
M&L for vitrified ceramic coloured tiles 8mm to 9mm thick (square/ rectangular) polished of light shade, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed by Engr-in-Charge.
300
-
-
M&L for vitrified ceramic coloured tiles 8mm to 9mm thick (square/ rectangular) polished of light shade, area of each tiles not exceeding 0.36 sqm, in dado/ skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed by Engr-in-Charge.
20
-
-
Taking down chowkats or frames including shutter (without taking off shutters from the frame) area not exc 1.50 Sqm each, complete all as specified and directed by Engr-in-Charge.
5
-
-
Taking down chowkats or frames including shutter (without taking off shutters from the frame) area exc 1.50 Sqm but n.exc 4.00 sqm each, complete all as specified and directed by Engr-in-Charge.
22
-
-
Supplying, fabricating & fixing aluminium door shutters with powder coating (minimum thickness of powder coating 50 micron), vertical stile of door shutter of size 85mm x 44.45mm x 1.5mm thick, top, middle and bottom rail of size 85mm x 44.45mm x 1.5mm thick and fixing plain/ tinted sheet glass or ACP sheet with aluminium beading and rubber gasket/ beading as directed. One mortice lock for alumium door (each) and three nos aluminium hinges of size 100mm and two alumium tower bolts of 150mm size for each door fixed with rawl plug includimg rectification of floor/ wall to match the existing surface, complete all as specified and directed by Engr-in-Charge. (Cost of sheet glass/ ACP sheet shall be measured and paid seperately).
5
-
-
Suuply only 4.8mm thick glass (plain or tinted) fixed with beading in aluminium frame in square exc 0.5 sqm in each pane, complete all as specified and directed by Engr-in-Charge.
2
-
-
Supply only 3mm thick aluminium composite panel (ACP) sheet including necessary clips, rubber packing and aluminium beading, complete all as specified and directed by Engr-in-Charge.
2
-
-
S&F 150mm size aluminium alloy handles, cast type, anodised, complete all as specified and directed by Engr-in-Charge.
4
-
-
S/F aluminium powder coated glazed three track sliding window of frame 100x44x1.5mm and sliding shutter of section 40mmx19mm including 3mm thick sheet glass, ordinary quality exceeding 0.50 Sqm in each pane, in two track shutter and in one track stainless steel wire cloth, 0.30 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, all fitting such as aluminium handle of size 100mm and locking arrangement with each moving leaf, complete all as specified and directed by Engr-in-Charge.
40
-
-
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, fillets etc & existing electrical wiring, and removal of debries from site complete all as specified and directed by Engr-in-Charge.
300
-
-
M&L for exposed GI frame/ grid system duly powder coated for module size of 600 x 600 mm suitable for lay-in aluminium/ metal/ mineral fiber ceiling ties having main T runner of 24mm size, suspended at 1200 mm C/C and cross T runner of 24 mm size, suspended at 600 mm C/C with interlocking arrangement to form grid of 600 x 600 mm , perimeter runner/ channel of 15 mm size, main and cross T runner supported by 4mm dia GI rod from slab/ roof, wall angle etc with and including all fixing accessories and making good of disturbed wall surrfaces with POP and one coat of oil emulsion distemper, as required to match the existing surfaces, complete all as specified and directed by Engr-in-Charge.
300
-
-
M&L for metal false ceiling, lay-in type, 0.5mm thick having tegular edge profile , duly powder coated, perforated type with glass fiber acoustic fleece, suitable for false ceiling grid/ frame module of 595 x 595mm size, complete all as specified and directed by Engr-in-Charge.
(Note: The grid/ frame shall be measured and paid for separetly).
300
-
-
Dismantling of plain or corrugated steel sheeting any gauge, thickness, from roof coverings including ridges, hips, valleys and flashings etc complete all as specified and as directed by Engineer-in-Charge.
610
-
-
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in lroof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
590
-
-
S&F pre-painted galvaume aluminium zink coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covelring/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
20
-
-
Dismantling mild steel or wrought iron work of any description not otherwise provided for, complete all as specified and directed by Engr-in-Charge.
20
-
-
S&F steel work in tubular trusses/ square pipes including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS1161-1979 grade St.-240, complete all as specified and directed by Engr-in-Charge.
2000
-
-
M&L for preparation of new steel surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engr-in-Charge.
80
-
-
Taking down carefully unserviceable of aluminium point wiring complete except for ceiling or where not feasible fan/plug/bell but including fittings such as switches, ceiling rose, pendants, regulator etc. and making good disturbed surface to match with the existing surface of roof/ wall/ floor by applying putty and applying colour/ white wash finish complete all as specified and directed by Engr-in-Charge.
155
-
-
M & L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC surface conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, GI metal flush box of 1.60 mm thick suitable for modular / conventional switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed by Engr-in-Charge.
One light/fan/bell/exhaust fan point controlled by one switch.
Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws etc as applicable will be included in quoted rates.
92
-
-
All as per srl item No. 32 here-in-before but One 3 Pin socket outlet 5 Amps on Independent board complete all as specified and directed by Engr-in-Charge.
31
-
-
All as per srl item No. 32 here-in-before but One 3 Pin socket outlet 5 Amps on same board complete all as specified and directed by Engr-in-Charge.
8
-
-
All as per srl item No. 32 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point complete all as specified and directed by Engr-in-Charge.
24
-
-
S & F Modular Switch 1 way 16 A, 1 Module complete all as specified and directed by Engr-in-Charge.
24
-
-
S & F Modular Socket 6 / 16 A - 2/3 Pin combined 2 module complete all as specified and directed by Engr-in-Charge.
24
-
-
S & F Modular Switch 1 way 6 /10 A, 1 Module complete all as specified and directed by Engr-in-Charge.
131
-
-
S & F Modular Socket 6 / 10 A - 2 / 3 Pin combined 2 module complete all as specified and directed by Engr-in-Charge.
39
-
-
S & F Modular fan regulator step type, 120W 2 Module complete all as specified and directed by Engr-in-Charge.
11
-
-
S & F of Ceiling rose surface Polycarbonate type with three terminals 240 Volts complete all as specified and directed by Engr-in-Charge.
92
-
-
S & F in replacement of Modular AC Box, power socket with top 240 Volts AC complete with one SP MCB single pole 20 Amps concealed/ flush to wall surface complete all as specified and directed by Engr-in-Charge.
4
-
-
S & F in replacement of LED tube light fitting 20 watt (CW), extruded aluminium batten with high efficient LEDs available in milky diffuser and Colour Rendering Index (CRI70), IP20, correlated Colour Temperature (CCT- 5700K to 6500K), PF0.9 and Voltage rated 220V to 240V complete all as specified and directed by Engr-in-Charge.
69
-
-
S & F in replacement of LED light fitting mirror type with high output diffuser, 10 watt 220 V, AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
4
-
-
S & F in replacement of LED street / security light fittings 35/36 Watt with day and night sensor available ,high pressure die cast aluminium housing, IP 65 should have minimum efficiency at level =120lumens/watt, CCT 4000-6500K with same lumens/w CRI80, PF0.95, an operating voltage range of 140-270V complete all as specified and directed by Engr-in-Charge.
8
-
-
Taking down unserviceable sub main wiring of aluminium any type with earth wire and making good disturbed surfaces of wall/ floor or roof etc and applying putty complete all as specified and directed by Engr-in-Charge.
90
-
-
Material and labour for Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit with wall thickness 1.6mm thick and including 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB complete all as specified and directed by Engr-in-Charge.
Note : 1. The two run of 4 Sqmm wire, one run of 4 Sqmm wire and 1 mtr PVC conduit pipe will be measured as one unit.
2. Cutting chases required for sub main wiring shall be finished with cement mortar 1:4 and surface shall be matched with existing shade of surface shall be deemed to be included in the unit rate quoted by the contractor.
40
-
-
Material and labour for Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit with wall thickness 1.6mm thick and including 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB complete all as directed.
Note : 1. The two run of 6 Sqmm wire, one run of 6 Sqmm wire and 1 mtr PVC conduit pipe will be measured as one unit.
2. Cutting chases required for sub main wiring shall be finished with cement mortar 1:4 and surface shall be matched with existing shade of surface shall be deemed to be included in the unit rate quoted by the contractor.
50
-
-
S & F in replacement MCB, SP, 6 to 32 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed by Engr-in-Charge.
28
-
-
S & F in replacement MCB, SPN, 32 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed by Engr-in-Charge.
4
-
-
S & F in replacement MCB, SP, 40 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed by Engr-in-Charge.
4
-
-
S & F in replacement MCCB, 415 Volt, 16kA, 4 pole, 100 Amp capacity with over load and short circuit protection complete all as specified and directed by Engr-in-Charge.
1
-
-
S & F in replacement Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, VTPN 8 way, 415 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCBs / MCBs and isolators etc and making all necessary connections complete all as specified and directed by Engr-in-Charge.
1
-
-
S & F in replacement Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, recess/surface mounting, SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as specified and directed by Engr-in-Charge.
2
-
-
S & F in replacement Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection,recess/surface mounting, SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as specified and directed by Engr-in-Charge.
2
-
-
Taking down carefully ceiling / exhaust fan of any size, sealing cable end, dismantling blades & removing fan and blades to store complete all as specified and directed by Engr-in-Charge.
21
-
-
Hanging only ceiling fan/ exhaust fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed by Engr-in-Charge.
11
-
-
M & L Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all by means of nuts and bolt check nuts and washers of galvanised iron sheet all as shown in electrical plate Nos 5 of SSR Part - I and connected to and including earthing test point complete including testing filling of adequate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil up to 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made but at 6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and directed by Engr-in-Charge.
2
-
-
S&L, testing and jointing XLPE insulated, screened, PVC bedded, galvanised stee strip or wire armoured , electric power cable (heavy duty) w, 1100 V grade with aluminium conductorof 16 sqmm, 4 core complete all as specified and directed by Engr-in-Charge.
100
-
-
S&F GI tubing light grade 80mm dia with all fittings laid in trenches/fixed on wall/ceiling including dismantling of old pipe etc. complete all as specified and directed by Engr-in-Charge.
7
-
-
Excavation in trenches not exe 1.5m depth and not exe 1.5m wide in Soft/loose soil and getting out complete all as specified and directed by Engr-in-Charge.
20.25
-
-
M & L for road cutting /hard standing for laying of cable and re making good the same to match the existing surface complete all as specified and directed by Engr-in-Charge.
5
-
-
Supply and spread river sand for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified and directed by Engr-in-Charge.
8.1
-
-
Supplying laying, brick sub class 'B' common burnt laid in trenches for cable protection complete all as specified and directed by Engr-in-Charge.
0.8
-
-
Returning, filling in including spreading, leveling, watering and well ramming in layers not exe.25cm at a level complete all as specified and directed by Engr-in-Charge.
10.56
-
-
Removal of surplus soil to a distance not exe 50m and depositing where directed at a level not exe1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
9.69
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and refixing the same as per exiting floor tiles complete all as specified and directed by Engr-in-Charge.
35
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%