Military Engineer Services Tender
... More
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_697875_1Tender No
CWE-ND/66/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Material and labour for servicing of outdoor VRF ACs capacity 12 HP (ADC Surgical block) as per OEM(Voltas) direction with the help of Pressure Booster Pump including following:- (a) Chemical cleaning of PVC grills, air filters (b) Cleaning, washing, removing of dirt over coil (c) Checking power connection cleaning / washing of cooling coil of outdoor cooling unit and condenser coil of outdoor unit and re-assembling the dismantled components of its original position complete all as directed by Engr-in-Charge.
4
-
-
... More
Material and labour for servicing of outdoor VRF ACs capacity 10 HP (ADC Surgical block) as per OEM(Voltas) direction with the help of Pressure Booster Pump including following:- (a) Chemical cleaning of PVC grills, air filters (b) Cleaning, washing, removing of dirt over coil (c) Checking power connection cleaning / washing of cooling coil of outdoor cooling unit and condenser coil of outdoor unit and re-assembling the dismantled components of its original position complete all as directed by Engr-in-Charge.
4
-
-
... More
Note - For ser item 2 and 3 (a) During the contract period if multiple services are required based on cooling efficiency. (b) Monthly checking & technical assessment of the plant.
-
-
-
... More
Material and Labour for servicing of Cassette unit of various capacities with the help of Air pressure and chemical washing including cleaning of air filter refixing in its original position all as directed by Engr-in-Charge.
18
-
-
... More
Material and labour for servicing of fan coil unit (FCU) with the help of chemical cleaning and Pressure booster pump all as directed by Engr-in -Charge.
6
-
-
... More
Material and labour for Topping up of Gas Charging with R-407C for Package type/VRF AC any make or any capacity all as directed by Engr-in-Charge.
40
-
-
... More
Material and labour for Topping up of Gas Charging with R-410 for Package type/VRF AC any make or any capacity all as directed by Engr-in-Charge.
30
-
-
... More
Material and labour for Topping up Gas Charging with R-404 for Package type/VRF AC any make or any capacity all as directed by Engr-in-Charge.
40
-
-
... More
Material and labour for Topping up Gas Charging with R-22 for Package type/VRF AC any make or any capacity all as directed by Engr-in-Charge.
20
-
-
... More
Calibration of any capacity VRF outdoor & indoor communication estabilishing (12 HP+10 HP) x4 circuit and all safety features all as directed by Engr-in-Charge. Note:- Calibration work will be done therough OEM only .OEM will submit data sheet regarding calibration to deptt.
4
-
-
... More
S&F, in replacement of copper tubing of 3/8” dia suitable for VRF AC/Package type ACs as per existiong copper tube including brazing / cutting / bendinng all as specified and directed by Engr-in-Charge.
20
-
-
... More
S&F, in replacement of copper tubing of 5/8” dia suitable for VRF AC/Package type ACs as per existiong copper tube including brazing / cutting / bendinng all as specified and directed by Engr-in-Charge.
20
-
-
... More
M&L for dismantling of electric driven horizontal induction motor of following capacities of any type and make, including disconnecting of electric connections, dismantling of motor, taking out the burnt windings, cleaning and washing of slots and rewinding the same with copper winding wire of existing gauge and quantity (as per original manufacturer design) including replacement of all damaged parts if required i. e. bearings, bush, thrust plate, thrust bearing, connector plate, insulating materials such as insulating sheets insulating paper (Class "F"), sealing compounds etc. and reassembling the motor after varnishing, heating/drying, greasing of moving parts etc. and reinstallation of the motor in original location,with proper alignment, & electric connection, conducting testing for smooth operation, complete all as directed.
Note : (i) The cost of winding wire and all replaced defective parts are deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. (ii) The cost of transportation (to and fro) and other necessary equipment for the same shall be arranged/brought by contractor to complete the job at site or at repair shop and no extra cost shall be paid to the contractor in this effect.
-
-
-
... More
1 HP
2
-
-
... More
2 HP
3
-
-
... More
3 HP
3
-
-
... More
7.5 HP
2
-
-
... More
10 HP
2
-
-
... More
M&L for complete overhauling of condenser / chiller centrifugal pump set of following capacities including disconnecting suction & discharge water lines and removing electric connection, dismantling the existing pump set from MS foundation, detaching the pump, opening the pump, remetaling the shaft and filling of metal at decayed portions including all kind of machine works i.e. welding, turning, polishing etc. as required to make the shaft of required shape and size, as original, balancing the shaft and refitting in pump bodyreplacement of foot anti vibration pad and reassembling the pump after greasing of moving parts and reinstallation of the pump with motor in original location using new MS stud, nut, bolt, washer and other packing material etc, checking the alignment, reconnecting the suction and delivery pipes, making proper electric connection, testing and commissioning for smooth operation at optimum efficiency, complete all as directed.
Note: including TPT,tools ,Item/ spare parts as per site requirment deemed in the quoted rate.
-
-
-
... More
1 HP
1
-
-
... More
2 HP
2
-
-
... More
3 HP
2
-
-
... More
5 HP
2
-
-
... More
S&F, in replacement of control MCB, C Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection complete all as directed.
5
-
-
... More
Supply & fixing in replacement, of MCB 32 Amp,4 pole, 10 KA, C Curve, complete all as directed.
8
-
-
... More
Supply & fixing in replacement, of MCB 40 Amp,4 pole, 10 KA, C Curve, complete all as directed.
8
-
-
... More
Supply & fixing in replacement, of MCB 63 Amp,4 pole, 10 KA, C Curve, complete all as directed.
6
-
-
... More
Supply & fixing in replacement, of MCCB 63 Amp, 3 pole, thermal magnetic release based with breaking capacity 16KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith Spreader terminals and phase barriers, complete all as directed.
5
-
-
... More
Supply & fixing in replacement, of MCCB 100 Amp, 4 pole, thermal magnetic release based with breaking capacity 16KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith Spreader terminals and phase barriers, complete all as directed.
5
-
-
... More
Supply & fixing in replacement, of MCCB 160 Amp, 3 pole, thermal magnetic release based with breaking capacity 36KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith Spreader terminals and phase barriers, complete all as directed.
2
-
-
... More
Supply & fixing in replacement, of MCCB 250 Amp, 4 pole, thermal magnetic release based with breaking capacity 36KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith Spreader terminals and phase barriers, complete all as directed.
1
-
-
... More
Supply & fixing in replacement, of MCCB 400 Amps, 3 pole, Micro processor based with breaking capacity 36KA, Ics = 100% Icu, with adjustable natural pole protection ,Innovative front indication LEDs ,adjustable over load setting alongwith Spreader terminals and phase barriers complete all as specified and directed .
1
-
-
... More
Supply and fix in replacement three pole power contactor capacity 32/40 Amps type MNX32/40 415 Volt ,50 Hz,coil voltage 240 Volts complete all as specified and as directed.
8
-
-
... More
Supply and fix in replacement three pole power contactor capacity 25 Amps type MNX25 415 Volt ,50 Hz,coil voltage 240 Volts complete all as specified and as directed.
6
-
-
... More
Supply and fix in replacement three pole power contactor capacity 18 Amps type MNX18 415 Volt ,50 Hz,coil voltage 240 Volts complete all as specified and as directed.
6
-
-
... More
Supply and fix in replacement three pole power contactor capacity 12 Amps type MNX12 415 Volt ,50 Hz,coil voltage 240 Volts complete all as specified and as directed.
6
-
-
... More
Supply and fix in replacement front mounting auxilary contact blocks for suitable contactor any description type 2NO+2NC (MNX/MCX) all as direction by Engr-in-Charge.
8
-
-
... More
Supply & fixing in replacement of over load relay upto 3-5 Amps, direct / separate mounting on contactors, as required, and making all electric connection, complete all as directed.
3
-
-
... More
Supply & fixing in replacement of over load relay range 9-15 Amps, direct / separate mounting on contactors, as required, and making all electric connection including, complete all as directed.
3
-
-
... More
Supply & fixing In replacement of Star Delta electronic timer time delay 3 to 30 second as per existing size and all as directed by Engr -in Charge.
15
-
-
... More
Supply & fixing in replacement of single phase preventor relay 415 V ,mode of operation Auto/Manual/Bypass, auto restrat with in 30 sec suitable for Star-delta strater incl taking down of unserviceable relay and making all electric connection, complete all as directed.
5
-
-
... More
Supply & fixing in replacement of LED type indicator lamp of red/blue/green colour for phase indication, complete all as directed.
12
-
-
... More
Supply & fixing in replacement of Start/Stop push button, projecting head (push function) type, complete all as directed.
10
-
-
... More
Supply & fixing in replacement of current transformer of 30/5A,15 VA Class 1 burden, suitable to measuring current complete all as directed.
10
-
-
... More
M & L in replacement for panel wiring in replacement of un-armoured 10 Sqmm (nominal area), PVC insulated, single core, unsheathed and stranded copper conductor cable, ISI marked and making all electric connections, complete all as directed.
10
-
-
... More
M & Lin replacement for panel wiring in replacement of un-armoured 6 Sqmm (nominal area), PVC insulated, single core, unsheathed and stranded copper conductor cable, ISI marked and making all electric connections, complete all as directed.
10
-
-
... More
M & L in replacement for panel wiring in replacement of un-armoured 1 Sqmm (nominal area), PVC insulated, single core, unsheathed and stranded copper conductor cable, ISI marked and making all electric connections, complete all as directed.
10
-
-
... More
M&L for applying one coat of synthetic enameled spray paint of existing colour on steel/iron surfaces(existing) of pipes, LT panel boards etc with and incl preparing of surface by scratching / removing rust, dust and old paints etc with wire brush, emery paper, grinder etc complete all as directed.
10
-
-
... More
S & F in replacement Sheet metal enclosure of size 600 mm X 450 mm X 300 mm made with the help of 2 mm thick CRCA Sheet suitable for MCCB /Star & Delta switch gear/relay etc,switch gear should be hold on the shock proof hylam sheet of 2 mm thick , front door should be openable type holding with hinges and lock and key system for protection , start/ stop button and three phase indicator lamp including voltmeter/ameter ,single phase MCB for controls , busbar 160Amps Capacity . Note - fastener, nut and bolt /anchoring hook /drilling/colour painting deemed in the quoted rate and Switch gear should be measured and paid seperately .
5
-
-
... More
S & F three phase VFD (Variable Frequency Drive ) 7.5 Hp to 10 Hp capacity compact type with micro processor suitable for controlling of motor speed working voltage 415 Volt,50 Hz including cable connection as per existing position and taking down old unserviceable one all as directed by Engr-in-Charge.
2
-
-
... More
S& F in replacement scroll Compressor capacity 8.5 TR for package type ACs and taking down old unserviceable one complete as directed by Engineer-in-charge. Make: Danfoss(As per existing)
2
-
-
... More
S& F in replacement scroll Compressor capacity 12 TR for package type ACs and taking down old unserviceable one complete as directed by Engineer-in-charge. Make: Danfoss(As per existing)
1
-
-
... More
S& F in replacement scroll Compressor capacity 10 TR for package type ACs and taking down old unserviceable one complete as directed by Engineer-in-charge. Make: Danfoss(As per existing)
1
-
-
... More
S& F in replacement scroll Compressor capacity 5.5 TR for package type ACs and taking down old unserviceable one complete as directed by Engineer-in-charge. Make: Danfoss(As per existing)
2
-
-
... More
Supply and fix V-Belt suitable for 12000 CFM AHU including taking down u/s item all as directed by .
10
-
-
... More
Supply and fix V-Belt suitable for 6000 CFM AHU including taking down u/s item all as directed by .
10
-
-
... More
Supply and fix V-Belt suitable for 3000 CFM AHU including taking down u/s item all as directed by .
10
-
-
... More
S & F in replacement thermostatic expansion valve suitable for package type unit with 12 TR circuit complete all as specified and as directed.
2
-
-
... More
S & F in replacement drier filter suitable for package type AC complete all as specified and as directed.
10
-
-
... More
S&F in replacement water flow switch suitable for package type AC 22.5TR TR complete all as specified and as directed.
2
-
-
... More
S&F in replacement water flow switch suitable for package type AC 34 TR complete all as specified and as directed.
2
-
-
... More
S & F in replacement HP/LP switch suitable for package unit 22.5 TR complete all as specified and as directed.
6
-
-
... More
S & F in replacement HP/LP switch suitable for package unit 34 TR complete all as specified and as directed.
6
-
-
... More
S & F in replacement EWT/LWT sensor suitable for package unit 22.5/34 TR complete all as specified and as directed.
4
-
-
... More
S & F in replacement AFT switch suitable for package unit 22/34 TR complete all as specified and as directed.
2
-
-
... More
S&F in replacement condenser coil 2/3 row-deep suitable for package type unit 22.7TR including taking down old unserviceable coil complete all as specified and as directed.
2
-
-
... More
S&F in replacement condenser coil 2/3 row-deep suitable for package type unit 7.5TR including taking down old unserviceable coil complete all as specified and as directed.
1
-
-
... More
S&F in replacement condenser coil 2/3 row-deep suitable for package type unit 34TR including taking down old unserviceable coil complete all as specified and as directed.
1
-
-
... More
Checking of leakage in chiller circuit of package type AC Plant 22.5/34 TR, with the help of full pressure of Nitrogen gas to check the leakage and repairing/blocking of leakage with the help of copper brazing or block the leakage pipe and testing of complete circuit system to the satisfaction of Engr-in-charge complete all as specified and directed.
Note: Nitrogen gas required to check leakage is deemed to be included in quoted rates.
2
-
-
... More
S & F PVC insulated LT XLPE armoured heavy duty electric cable 4 core with aluminium conductor,1100 volt grade cross-sectional area 10 Sq mm with connection of motor /LT panel of AHUs including gland, thimble etc all as per site requirment and taking down old U/S Cable all as specified and directed by Engr- in -Charge.
20
-
-
... More
S & F PVC insulated LT XLPE armoured heavy duty electric cable 4 core with aluminium conductor,1100 volt grade cross-sectional area 16 Sq mm with connection of motor /LT panel of AHUs including gland, thimble etc all as per site requirment and taking down old U/S Cable all as specified and directed by Engr- in -Charge.
20
-
-
... More
S & F PVC insulated LT XLPE armoured heavy duty electric cable 3.5 core with aluminium conductor,1100 volt grade cross-sectional area 25 Sq mm with connection of motor /LT panel of AHUs including gland, thimble etc all as per site requirment and taking down old U/S Cable all as specified and directed by Engr- in -Charge.
20
-
-
... More
M&L for repair of PCB of package type unit any capacity by replacing whichever of the following parts is required to be changed i.e. capacitor, relay, optocoupler, microcontroller, resistor by taking out unserviceable complete all as specified and as directe
5
-
-
... More
S&F PCB card of outdoor unit of 12/10 HP VRF unit including taking down old unserviceable PCB complete all as specified and as directed.
2
-
-
... More
S&F in replacement PCB card of air cooled package type unit (Bluestar) capacity 22.5/34 TR by taking down old unserviceable card and doing proper electrical connection and testing on completion complete all as specified and as directed.
1
-
-
... More
S&F in replacement HMI display of air cooled package type unit (Bluestar) capacity 22.5/34 TR by taking down old unserviceable display and doing proper electrical connection and testing on completion complete all as specified and as directed.
2
-
-
... More
S&F in replacement wall mounted Star delta Starter 3 HP 3 phase including overload relay, electronic timer, phase failure relay, start and stop push buttons, ON/OFF indication lamp, voltmeter and ammeter including electrical connection complete all as specified and as directed.
2
-
-
... More
S&F in replacement wall mounted Star delta Starter 5 HP having overload relay, electronic timer, phase failure relay, start and stop push buttons, ON/OFF indication lamp, voltmeter and ammeter including electrical connection complete all as specified and as directed.
2
-
-
... More
M&L for servicing of hot water generator suitable for package type AC 22.5/34 TR by checking all safety, heaters, electronic circuit plate including proper cleaning of control panel complete all as specified and as directed.
2
-
-
... More
S&F heating rods of capacity 3 KW for hot water generator all as specified and directed by engr-in-charge.
4
-
-
... More
M&L for cleaning of inside surface of supply Return/Exhaust Ducts of HVAC system by (NADCA certified duct cleaning agency ) using high power vacuum air compressor robotic camera air hammer, special nozzle, air sweep with other required accessories and inspection of dust before and after cleaning of duct using color video inspection complete all as directed.
1200
-
-
... More
M&L in replacement motorised fire damper made up of 22 gauge GI sheet including fusible link, driving motor,actuator,spiral spring to tightens clock wise when motor is driven and with suitable size incl. control wiring from panel to damper for each damper all as specified and directed by engr-in-charge.Note:- All electrical components required to make equipment functional is deemed to be included in quoted rate.
54
-
-
... More
Supply, installation and testing of online electrostatic mechanical water treatment system with electrically operated control panel to be fixed on sub header of AC Plant. The outer casing shal be of 304 grade stainless steel with both ends falnged and capable preventing scale formation. The same shall be suitable for water flow rate 2700 LPM each dia of pipe 6''/150mm in condenser circuit. The work includes cutting of existing GI/MS sub header and providing mild steel flange heavy duty and joining with nut & bolts ,gaskets at both ends with welding and modification in existing system complete as reqd. electrostatic scale of online non chemical scale preventer system 'scale off'. Model No.7011 by M/S Weldon Engineers (India) suitable for 180 TR AC Plant. Make:- Weldon Engineers (INDIA) Scale off/Hydrokon/Dolphin
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%