Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date7 Jan 2021
Closing Date28 Jan 2021
Tender Amount₹ 22,71,545 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fix in replacement of gun metal single headed ISI marked oblique pattern hydrant valve with 80mm dia flanged inlet and 63mm dia female outlet branch pipe and nozzle conforming to IS : 903 including gun metal cap and GI chain realese type plug and all accessories as per IS : 5290 complete all as specified and directed by Engr-in-charge.

7

-

-

... More
Supply ,installing, testing and commissioning of hose box for hose reel of size 1200mmX2100X600mm internal dia made of 16 SWG MS sheet angle frame capable of accomodating of the following (for internal ) (i) 01 No 63mm dia oblique pattern instataneous female type GM landing valve with caps and chain conforming to IS : 5290 with 100mm dia pressure guage complete including taking down the existing one all as specified and directed by Engr-in-charge. (ii) 2X15 mtr long 20mm dia reinforced rubber hose reel with MS, painted , swing type reel drum 6.5mm nozzle etc conforming to IS: 884 incl supporting bracket. (iii) One set of GM branch pipe conforming to IS 903 (iv) One branch pipe, one fire man axe, first aid hose reel and fire extinguisher

6

-

-

... More
Supply, fixing, testing and commissioning in replacement of wall mounting swinging type first aid fire hose reel with drum, hanging bracket 30mtr long and 20mm dia high pressure hosereel as per IS: 444 with gun metal shutt off nozzle having 5mm dia orifice. The hose reel shall be conforming to IS: 884-1985. Rate shall including for 25mm dia MS pipe connection from riser to hose reel sockets, nipples, elbows and ball valve (25mm dia), Drum shall be fixed on adjoining wall through anchor fastener/cement concrete hook or MS stand as per site requirement and the rate for fixing/hanging items inthe rate quoted( for internal hydrant and one each an either side of stage) complete all as specified and directed by Engr -in-charge.

11

-

-

... More
S&F in replacement of 63mm dia15mtr long controlled perclating rubberised fabric hose conforming to IS: 8423 (type A) including gun metal male and female instantaneous coupling bound and rivetted to hose pipe with 1.5mm dia copper wire complete in all respect, hose BSI marked, conforming to IS : 636 type II and complete male female coupling conforming to IS :903 complete all as specified and directed by Engr-in-charge.

7

-

-

... More
Supply and fixing in replacement of fire hydrant stand post 1.5mtr height single head outlet gunmetal of 80mm dia with 63mm dia female outlet complete and 80mm inlet rubber blank cap and chain as per IS 5280-1983 suitable for brigade hose of 63mm with coupling conforming to IS 903 for external hydrant complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Supply, fixing , testing and commissioning in replacement of Gun Metal four way, fire brigade inlet to hydrant ring with 63mm dia instantaneous type inlet and 150mm dia flanged outlet conforming to IS : 904 with blank cap and chaincomplete all as specified and directed by Engr-in-charge.

1

-

-

... More
Supply ,fixing ,testing and commissioning in replacement of 150mm dia heavy duty class 'C' MS pipe 6mm thick ISI marked as per IS:1239 with all necessary fittings & fabrication like tees, elbow, flanges, reducer, gaskets, nut and bolts etc welding or screwed joint as required including fixing of pipe with necessary standard standard clamps structural steel supprt (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red color over two coats of red oxide primer complete all as specified and directed by Engr-in-charge.

120

-

-

... More
All as per item No.10 above but size of pipe 100mm.

150

-

-

... More
All as per item No.10 above but size of pipe 80mm.

200

-

-

... More
Supply and fixing in replacement of Cast Iron NRV of 150mm bore both end flanged with necessary packing materials nut, bolt & washer of suitable size PN 1.6 complete.

1

-

-

... More
S&F in replacement of valve reflux with by pass arrangement complete all as specified and directed by Engr-in-charge.

1

-

-

... More
S&F in replacement of 500 Ltrs capacity rotational moulded polyethylene water storage tank two layers Cylindrical vertical with closed top with threaded lid with 25 mm GI medium grade pipe for inlet, outlet, over flow, checknuts for inlet and outlet, hoisted and fixed in position.

2

-

-

... More
S&F in replacement of 80mm dia flanged end basket with foot valve conforming to IS:4038 strainer fabricated from 16 guage brass sheet with 3mm slot made from MS body bottom and top removable flange with nuts, bolts etc complete including joints and joining materials as per site requirement complete.

2

-

-

... More
Supply and fixing in replacement of rubber mat of size 1 mtr X2 Mtr X 19mm chequre type black complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Supply and installing in replacement of fire extinguisher mechanical foam 09 ltrs capacity conforming to IS :15683 all as specified and directed by Engr-in-charge.

6

-

-

... More
Supply and installation in replacement of fire extinguisher dry chemical powder (ABC type ) 6 kgs capacity conforming to IS : :15683 all as specified and directed by Engr-in-charge.

8

-

-

... More
Supply and installation in replacement of fire extinguisher light weight squeez grip type CO2 of 4.5 Kgs conforming to IS 15683 and all as specified and directed by Engr-in-charge.

8

-

-

... More
Supply & fixing in replacement of butterfly valve of size 150 mm dia conforming to IS :13095 , flanged ends drilled type with steel spindle including nuts bolts washers and jointing material complete.

2

-

-

... More
Supply & fixing in replacement of butterfly valve of size 100 mm dia conforming to IS: 13095 , flanged ends drilled type with steel spindle including nuts bolts washers and jointing material complete.

4

-

-

... More
Supply & fixing in replacement of non return butterfly valve of size 150 mm dia ISI marked all as specified and directed by Engr-in-charge.

1

-

-

... More
Supply & fixing in replacement of non return butterfly valve of size 80 mm dia ISI marked all as specified and directed by Engr-in-charge.

2

-

-

... More
Supply , fixing in replacement of 100mm dia burden type stainless steel dial type pressure gauge having calibration of 0-15 kg/cm2 including brass isolation valve and pipe all as specified and directed by Engr-in-charge.

2

-

-

... More
M&L for Servicing of induction motor 75 HP coupled with fire pump complete including oiling, burnt winding replacement, greasing replacement of wornout rubber packing, wornout nuts and washers etc including testing to the entire satisfaction of Engineer in charge.

1

-

-

... More
M& L for Servicing of induction motor 25 HP coupled with fire pump complete including oiling burnt winding replacement , greasing replacement of wornout rubber packing wornout nuts and washers etc including testing to the entire satisfaction of Engineer in charge.

1

-

-

... More
M&L for Servicing of induction motor 15 HP coupled with fire pump complete including oiling, burnt winding replacement, greasing replacement of wornout rubber packing wornout nuts and washers etc including testing to the entire satisfaction of Engineer in charge.

2

-

-

... More
Comprehensive monthly maintenance of auto fire alarm system installed in BBJ Hanger & RSS Hangar and ISH in Tech Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement will be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 02 Nos. (b) UL Listed intelligent addressable multi-criteria detector with base- 284 Nos. (c) UL Listed intelligent heat detector - 08 Nos. (d) Manual call point - 08 Nos. (e) Control module for hooter - 18 Nos. (f) zone Monitor module - 28 Nos. (g) Fault isolator - 12 Nos. (h) Wall mounted hooter - 18 Nos. (j) Response indicator - 25 Nos. (k) IR Flame detector - 28 Nos. (l) UPS 1 KVA - 02 No.

11

-

-

... More
Comprehensive monthly maintenance of auto fire alarm system installed in AW 101 Hanger No -I, II & III in Tech Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement will be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 02 No. (b) UL Listed intelligent addressable multi-criteria detector with base- 192 Nos. (c) UL Listed intelligent heat detector - 02 Nos. (d) Manual call point - 18 Nos. (e) Control module hooter - 05 Nos. (f) Monitor module - 06 Nos. (g) Fault isolator - 12 Nos. (h) Wall mounted hooter - 06 Nos. (j) Response indicator - 70 Nos. (k) IR Flame detector - 44 Nos. (l) UPS 1 KVA - 02 Nos.

11

-

-

... More
Comprehensive monthly maintenance of auto fire alarm system installed in SES LAB OF 181 FLIGHT, TWIN DSS BLDGS & CARGO TERMINAL in Tech Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Material required for replacement will be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 02 No. (b) UL Listed intelligent addressable multi-criteria detector with base- 59 Nos. (c) Manual call point - 05 Nos. (d) Control module for hooter - 05 Nos. (e) Fault isolator - 04 Nos. (f) Wall mounted hooter - 07 Nos. (g) Response indicator - 07 Nos.

11

-

-

... More
Comprehensive monthly maintenance of auto fire alarm system installed in SIGNAL EXCHANGE BLDG IN Camp area & EDN SECTION in Camp Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement will be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 02 No. (b) UL Listed intelligent addressable multi-criteria detector with base- 99 Nos. (c) UL listed intelligent heat detector-02 Nos (d) Manual call point - 08 Nos. (e) Control module for hooter - 08 Nos. (f) Monitor module- 09 Nos (g) Fault isolator - 06 Nos. (h) Wall mounted hooter - 08 Nos. (j) Response indicator - 48 Nos.

11

-

-

... More
Comprehensive monthly maintenance of auto fire alarm system installed in 737 Boeing Lab, 41 SQN Simulator Bldg in Tech Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement will be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 02 No. (b) UL Listed intelligent addressable multi-criteria detector with base- 130 Nos. (c) UL Listed intelligent heat detector - 04 Nos. (d) Manual call point - 11 Nos. (e) Control module for hooter - 06 Nos. (f) Monitor module - 05 Nos. (g) Fault isolator - 12 Nos. (h) Wall mounted hooter - 20 Nos. (j) Response indicator - 48 Nos. (k) UPS 1 KVA -02 Nos.

11

-

-

... More
Comprehensive monthly maintenance of auto fire alarm system installed in AFCNWP CAMP AREA at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement will be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 01 No. (b) UL Listed intelligent addressable multi-criteria detector with base- 65 Nos. (c) UL Listed intelligent heat detector - 06 Nos. (d) Manual call point - 06 Nos. (e) Control module for hooter - 06 Nos. (f) Monitor module - 06 Nos. (g) Fault isolator - 06 Nos. (h) Wall mounted hooter - 06 Nos. (j) Response indicator - 13 Nos.

11

-

-

... More
Comprehensive monthly maintenance of auto fire alarm system installed in SES SCTION OF CPRU, COLOUR LAB, CFNL LAB IN TECH AREA at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement will be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 03 No. (b) UL Listed intelligent addressable multi-criteria detector with base- 162 Nos. (c ) UL listed intelligent heat detector - 02 Nos (d) Manual call point - 14 Nos. (e) Control module for Manual call point - 14 Nos. (f) monitor module - 06 Nos. (g) Fault isolator - 10 Nos. (h) Wall mounted hooter - 14 Nos (j) Response indicator - 72 Nos. (k) sounder relay - 08 Nos. (l) UPS 1 KVA - 03 Nos. (m) central control including 21" colour monitor 21"and its CPU , Key board ,mouse & UPS -01 Set (n) Repeater panel -01 No

11

-

-

... More
Supply only in replacement of UL Listed addressable muiti-criteria type photo electric smoke cum thermal detectors (acelimate) with mounting base complete.

250

-

-

... More
Supply only in replacement of addressable manual call point/pull station single action type with gold plated SPST contacts. Make: Siemens./Honeywell

25

-

-

... More
Supply only in replacement of addressable control relay module for manual call point.

20

-

-

... More
Supply only in replacement of intelligent addressable monitor module.

10

-

-

... More
SSupply only in replacement of fault isolator module with automatic resetting arrangement.

10

-

-

... More
Supply only in replacement of response indicator (RI)

18

-

-

... More
Supply only in replacement of control module (HZM) item suitable for flame detectors

7

-

-

... More
Supply only in replacement of hooter with control module.

7

-

-

... More
Supply only in replacement of intelligent addressable heat detector with base.

4

-

-

... More
Supply only in replacement of Infra ray flame detector (beam detector).

10

-

-

... More
M&L for taking out unserviceable Power supply unit Model PSC-12 of Siemens Make from the existing Fire detection control panel and repairing the unit including replacement of unserviceable parts complete and refixing the same in its original position including testing commissioning complete all as specified and directed.

4

-

-

... More
M&L for taking out unserviceable repeater fault control panel of existing fire finder XLS system of Honey Well Make from the existing site and repairing the repeater panel including replacement of unserviceable parts complete and refixing the same in its original position including testing commissioning complete all as specified and directed.

1

-

-

... More
Supply only in replacement of PCB loop cord suitable for self addressable fire finder system.

5

-

-

... More
Supply & fixing in replacement of PVC insulated armoured copper conductor cable size 1.5 sqmm 2 core FRLS 1100 volts fixed on wall/celling of the hanger with fixing accessories complete.

380

-

-

... More
S & F in replacement of PVC insulated PVC sheathed copper conductor cable size 1.5 sqmm 2 core FRLS 1100 volts drawn in existing PVC conduit fixed on wall/celling of the bldg complete.

425

-

-

... More
Supply and fixing in replacemnt of PVC conduit medium grade of size 20 mm dia including fixing accessories like saddles, couplers bends tees etc complete.

50

-

-

... More
Supply only in replacement of UPS 1.0 KVA suitable for working on 230 Volts, 50 Hz AC supply complete.

14

-

-

... More
Supply only in replacement of Battery 12 Volts 7 AH dry type complete all as specified.

14

-

-

... More
Disconnecting and taking out old unserviceable CPU display unit including PMI of fire finder and supply and fixing new CPU display unit including PMI suitable for self addressable fire finder XLS system Make: Siemens/ Honey well/Edward

2

-

-

... More
Disconnecting and taking out old unserviceable Mother Board of fire finder and supply and fixing new mother board for two Nos loops cards suitable for self addressable fire finder XLS system Make: Siemens / Honey well/Edward

2

-

-

... More
Excavation in trenches not exc 1.5 metres wide and not exc1.5 metres deep for pipe line in soft/loose soil, getting out and levelling of bottom surface to required level all as specified and as directed by Engr-in-charge.

19

-

-

... More
Returning filling in, including spreading, leveling, watering and well ramming of soil in layers not exc 25 cm thick .

17

-

-

... More
Removing excavated material from site to a distance not exc 50 metres away and depositing where directed not exc 1.5 metres from the starting point.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.