Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date17 Dec 2024
Closing Date7 Jan 2025
Tender Amount₹ 44,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Notes for Item No 1.01 & 1.02 :- (i) Any material required for attending complaints shall be measured & separately under respectvie items here - in- after. (ii) The complaints shall be attended and the defetcs shall be rectified by a team of matric qualified having minimum 03 years experienced electrician/Plumber as applicable assisted with adequate No of helpers as directed by Engineer-in-charge. (iii) The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 50/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues. (iv) In case, after checking & attending the defect, it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Engineer-in- charge is satisfied with contractors view, no recovery will be made. (v) While attending the complaint of water supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A' i.e item No 3.0 to 12, 14, 15, 35 & 38. However , no extra payments shall be made for dewatering. (vi) Cutting of GI pipe in position and threading is also deemed to be included in the job rate (Fittings and fixtures will be measured and paid separetely under respective items of Sch).

-

-

-

... More
(vii) All T&P required for attending the Complaints shall be provided by the contractor. (viii) The Pipe Fitter shall always be in possession of die set complete with cutters,Taps, Pipe wrench, Chain wrench, Caulking tools, complete set of spanners and ladders etc as required at site. (ix) The Electrician shall always in possession of all Electrician tools, LT Megger, Earth Tester, Multimeter, Crimpling tool, insulation tape, Hand gloves etc required at site. (x) Rate for taking down/out existing & fittings & fixtures and refixing to make it functional shall be into account. (xi) A BOO ordered for material procured by contractor and taken on charge through RV and complaint wise dockets will maintained and USR's duly vetted by AO GE (E/M) for procured materials issued for incorporation in work will be mentioned in BOO. BOO will concorn/approved by Accepting Officer in one time for complete materials to be consumed in work and if any balance quantity of material left with contractor the same will received back on credit USR's & kept on record. (xii) Old U/s material iron scarp obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill)

-

-

-

... More
Supply only GI socket Med grade ISI marked of following sizes :

-

-

-

... More
15 mm bore

60

-

-

... More
20mm bore

110

-

-

... More
25mm bore

50

-

-

... More
40mm bore

30

-

-

... More
50mm bore

40

-

-

... More
Supply only GI Elbow Med grade ISI marked of following sizes :

-

-

-

... More
15 mm bore

60

-

-

... More
20mm bore

110

-

-

... More
25mm bore

50

-

-

... More
40mm bore

30

-

-

... More
50mm bore

30

-

-

... More
Supply only GI Union Med grade ISI marked of following sizes :

-

-

-

... More
15 mm bore

40

-

-

... More
20mm bore

60

-

-

... More
25mm bore

25

-

-

... More
40mm bore

20

-

-

... More
50mm bore

25

-

-

... More
Supply only GI Nipple Med grade ISI marked of following sizes :

-

-

-

... More
15 mm bore

48

-

-

... More
20mm bore

65

-

-

... More
25mm bore

40

-

-

... More
40mm bore

15

-

-

... More
50mm bore

15

-

-

... More
Supply only GI Reducer socket Med grade ISI marked of following sizes :

-

-

-

... More
20mm x 15 mm bore

10

-

-

... More
25mm x 15mm bore

10

-

-

... More
25mm x 20mm bore

15

-

-

... More
50mm x 40 mm bore

10

-

-

... More
Supply only GI solid plug heavy duty ISI marked of following sizes :

-

-

-

... More
15 mm bore

15

-

-

... More
20mm bore

15

-

-

... More
25mm bore

10

-

-

... More
40mm bore

5

-

-

... More
50mm bore

5

-

-

... More
Supply only GI Tee Med grade ISI marked of following sizes :

-

-

-

... More
15mm x 15mm x15 mm bore

10

-

-

... More
20mm x 20mm x15 mm bore

10

-

-

... More
20mm x 20mm x 20 mm bore

10

-

-

... More
25mm x 25mm x 25 mm bore

10

-

-

... More
25mm x 25mm x 15 mm bore

5

-

-

... More
40mm x 40mm x 40mm bore

5

-

-

... More
50mm x 50mm x 50 mm bore

5

-

-

... More
50mm x50mm x25 mm bore

5

-

-

... More
Supply only PTMT Float valve with epoxy coated aluminium rod and high density plastic ball complete of following sizes :

-

-

-

... More
15 mm bore

60

-

-

... More
20 mm bore

100

-

-

... More
25 mm bore

40

-

-

... More
50 mm bore

15

-

-

... More
Supply only Gun metal gate valve with iron wheel head screwed both ends for iron pipe as per IS-778 compete, ISI marked of following sizes :-

-

-

-

... More
15 mm bore

15

-

-

... More
20 mm bore

15

-

-

... More
25 mm bore

15

-

-

... More
40 mm bore

10

-

-

... More
50mm bore

10

-

-

... More
Supply only following items in loose containers:-

-

-

-

... More
Supply only Lead Pig bar

100

-

-

... More
Supply only Spun yarn

20

-

-

... More
Labour only for run lead joint by using new lead and new spun yarn including jointing material for CI/DI pipes of following size/bore (Note: Lead and spun yarn used for repairing the following sizes of pipe joints shall be paid separately)

-

-

-

... More
80 mm bore

10

-

-

... More
100 mm bore

18

-

-

... More
150 mm bore

15

-

-

... More
Supply only Nuts ,Bolts and Washers 25 to 150 mm long of 6 to 20 mm dia complete all as specified and directed.

30

-

-

... More
Supply only 15mm bore Bib tap of PTMT, any tint, high pressure screwed for made/Female threaded for pipe of size 15mm bore complete all as specified and directed.

100

-

-

... More
Taking up old GI steel tubing with connection including fittings all as specified and as directed by Engineer-in-Charge of the follwing sizes :- (Note :- Old U/s iron scrap obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill)

-

-

-

... More
15 mm bore dia

455

-

-

... More
20 mm bore dia

500

-

-

... More
25 mm bore dia

450

-

-

... More
40 mm bore dia

280

-

-

... More
50 mm bore dia

500

-

-

... More
Supply & Laying of GI pipe medium grade ISI mark including all fittings in old/new positions in trenches/wall/floor complet and making good the distributed surfaces as per existing as directed of following sizes. (Note:- Excavation and earth work will be measured and paid separately.)

-

-

-

... More
15 mm bore

455

-

-

... More
20 mm bore

500

-

-

... More
25 mm bore

450

-

-

... More
40 mm bore

280

-

-

... More
50 mm bore

500

-

-

... More
Taking up GI/Nidhi/CI/MS/DI Pipes including all fitting as available at the site of the following sizes complete all as specified and directed by Engineer-in-Charge (Note :- Old U/s DI/CI Pipe obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill)

-

-

-

... More
80 mm bore

100

-

-

... More
100 mm bore

155

-

-

... More
150mm bore

125

-

-

... More
200 mm bore

50

-

-

... More
Supply, laying jointing, testing DI pipe with class-K-7 spigot socketed ends , conforming to IS-8329 laid in trenches including providing route indicators of suitable height and laying at spacing of @ 50m center to center at GL mentioning name of contractor, date of execution & CA No with name of work & rubber gasket (Tyton) joints with jointing material & route indicators of the following sizes complete all as specified and directed by Engineer-in-Charge. Note 1: - Excavation & earth work shall be measured and paid seperately under respective items of BOQ. Note 2:- Contractors will provide route indicators mild steel body with top 150 mm plate 3mm thick and height not less than 300mm above finished GL at suitable intervals as directed by EIC. Cost of route indicators shall be deemed included in quoted unit rates. Note3:- DI pipe whole quantity of tender shall be procured by contractor in one time from the authorised dealer of approved make and PV's, MTC & e-way bill will produced by contractor during payment of 1st RAR as material laying at site. Note4:- Piece meal site for laying of pipe shall be given by EIC and contractor arrange to transport the DI pipe accordingly at his own arrangement. No any additional payment for transportation will be given to contractor. Contractors are requested to quote rate accordingly. Note5:- Layout plan for laying of DI pipe shall be given by EIC in writing. Note6 :- Cost of Rubber gasket joints (Tyton Joint) included in quoted unit rates.)

-

-

-

... More
80 mm bore

100

-

-

... More
100 mm bore

155

-

-

... More
150 mm bore

125

-

-

... More
200 mm bore

50

-

-

... More
M&L in repair DI specials like bends, tapers any type any radius and angle, Tee pieces single branch `Y' junction, double branch, cross (all sockets or socket and spigot) collars, DI connecting pieces one end flanged and other end spigot/socket, reducers/bell mouth pieces one end flanged and other end tapering as bell mouth for the size up to 250 mm dia bore complete all as specified and directed. (Note :- Old U/s DI fitting obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill)

180

-

-

... More
Supplying, laying, jointing, welding and testing MS Pipe (Heavy class 'C') IS : 1239/3589, of followiing sizes laid in trenches or in Horizontal/Vertical/inclined position or laying on floors for connections for suction, to header and connected to out going water main CI/DI pipe line, for following size including taking out the old unserviceable pipes :- (Note:- (i) MS Flanges incl fabrication work will be measured and paid separately. (ii) Excavation and earth work will be measured and paid separately. (iii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill.)

-

-

-

... More
80 mm dia

30

-

-

... More
100 mm dia

42

-

-

... More
150 mm dia

30

-

-

... More
M&L including jointing and testing of cast iron sluice valves class PN-1.0, conforming to IS:14846 flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gaskets including taking out unserviceable sluice valve and removal from site for the follwing sizes complete all as specified and directed:- (Note:- Old U/s sluice valve material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in numbers (EACH) shall be taken into account and attach with RAR/F Bill.)

-

-

-

... More
80 mm bore

2

-

-

... More
100 mm bore

2

-

-

... More
150 mm bore

4

-

-

... More
200 mm bore

2

-

-

... More
Supply and Fixing in replacement of CI Foot valve PN 0.2 of following size , Flanged ends, Swing type opration with rubber sheet as per IS-4038 including taking out unserviceable of following sizes complete all as specified and directed. (Note :- Flanged joints comlete with jointing material shall deemed to be included in the unit rate of this items.)

-

-

-

... More
80 mm bore

1

-

-

... More
100 mm bore

2

-

-

... More
150 mm bore

4

-

-

... More
M&L painting two coat of synthetic enamel paint as per existing pattern on pipe surface/header connection including preparation of surfaces by scratching and removing the rust, applying one coat red oxide primer complete all as specified and as directed.

100

-

-

... More
M&L for removing weeds and wild grass inside the installations using chemical spray and trimming trees and unwanted plants using petrol operated Tree/Grass cutting tools and dressing of the surface by scrapping high patches and filling low patches with the scrapping soil to give an even and neat look to the site and disposing off all the unwanted grass, bushes and debris complete all as specified and directed by the Engineer-in-Charge.

1500

-

-

... More
Openning of gland packing coupling and removing the unserviceable gland rope from Sluice valve of size 80 to 300 mm dia and fixing the new gland rope all as per existing size gland rope complete all as specified and directed.

75

-

-

... More
M&L Decorative ultra slim round profile LED lighting fitting/fixture of 20W, 6000K, with extruded polycarbonate environmental friendly energy efficient box and other fittings incl taking down old unsv light fitting with bracket complete all as specified and as directed. (Note:- Old U/s material fitting obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in weight (KG) shall be taken into account and attach with RAR/F Bill.

50

-

-

... More
Supply and fixing in replacement 45 watt LED street light New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 including making connections with GI pipe 0.6mtr angle braket fixing on wall and connectng to ceiling rose with apropriate wire complete all as specified and directed. (Note:- Old U/s material street light fitting obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap of brackets, if available at site in weight (KG) shall be taken into account and attach with RAR/F Bill.

8

-

-

... More
Excvation in trenches not exc. 1.5 mtr wide and not exc 1.5 mtr deep for pipe line in soft/loose soil, getting out and levelling of bottom surface as required complete all as specified and as directed.

260

-

-

... More
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed.

234

-

-

... More
Removing excavated material to a distance not exc 50 m and depositing where directed not exc 1.5 meters above the starting point complete all as specified and as directed.

26

-

-

... More
Labour work required for taking out suction pipe from sump of any capacity 80 mm to 200 mm size screw / flanged type and relowering after refixing in position the same duly cleaned / minor repair if any required such as replacement of rubber gasket / lifting bolts & nuts including making thread for the suction pipes off sizes etc complete all as specified and directed by Engineer - in - charge

10

-

-

... More
M&L for testing of drinking water being collected from local source (bore wells/shallow wells/under ground sumps) one test in one month for one source in the area under AGE (U) W/S No-I as directed by EIC and submission of detailed test report to the office of Engineer-in-Charge. (a) Collection of water from different sources of water ie Sump, bore wells & shallow wells in sterilized bottle and testing in Govt Approved laboratory as mentioned in specification. (b) Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour, taste, turbidity, Lead, PH value TDS total hardness, iron, chloride, fluride and residual free chlorine and Bacteriological total Collie from organisms per 100 ml (MPN) and E Collie in 100 ml) and submission to this office with specific recommendation regarding suitability of water for drinking purpose. Note :- Rate quoted shall deemed to be included for : - (i) Cost of sterilized bottle as required. (ii) To and fro transportation charges for collection of samples from source(sump/bore well/shallow wells) (iii) Contractor will required to visit the site of AGE (U) W/S-I area for working out number of sources i.e borewells/shallow wells/under ground sumps etc. Approximately 50 Number of tests will be carried out in eleven months period. (iv) Period of testing of water sources is of 11 (Eleven) months from the commencement of work. (v) Mode of payment: - Payment will be made after completion of work as one JOB for 11 (Eleven) months for number of tests. Part payment will be allowed after dividing number of months in quoted unit rate.

1

-

-

... More
Supply only switch /sockets ISI marked of following items :

-

-

-

... More
Switch piano flush type 5/6 Amps singal pole one way, 240 volts complete all as specified and directed.

20

-

-

... More
Switch piano flush type 15/16 Amps singal pole one way, 240 complete all as specified and directed.

10

-

-

... More
Socket outlet 2 in 1, 3/5 pin, 5/6 Amps 240 volts complete all as specified and directed.

10

-

-

... More
Socket outlet 2 in 1, 3/5 pin, 15/16 Amps 240 volts complete all as specified and directed.

10

-

-

... More
Switch socket combination 2 in 1, 3/5 pin, 5/6 Amps 240 volts complete all as specified and directed.

10

-

-

... More
Switch socket combination 2 in 1, 3/5 pin, 15/16 Amps 240 volts complete all as specified and directed.

10

-

-

... More
Supply only following electrical items:-

-

-

-

... More
MCB SP 10 to 32 Amp, 240 volts complete all as specified and directed.

10

-

-

... More
SPN 40 Amp , 240 volt complete all as specified and directed.

5

-

-

... More
MCB TP 63 Amp , 415 volt

4

-

-

... More
PVC insulation tape role 15mm wide, 20 Running meter long complete all as specified and directed.

20

-

-

... More
Supply only FRLS type PVC insulated multistranded copper conductor wire of size 1.5 Sqmm, 1100 volts grade complete all as specified and directed.

50

-

-

... More
Supply only FRLS type PVC insulated multistranded copper conductor wire of size 2.5 Sqmm, 1100 volts grade complete all as specified and directed. Note for ser item No 35 & 36 :- (i) Old U/s material electrical fittings obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in weight (KG) shall be taken into account and attach with RAR/F Bill. (ii) Old U/s material copper wire obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of copper scrap in weight (KG) shall be taken into account and attach with RAR/F Bill.

50

-

-

... More
Suppply & fixing in replacement MCCB 25-100 Amps fixed type, 3 pole, 415 V, breaking capacity 16 kA, connection complete all as specifed and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill.

10

-

-

... More
Suppply & fixing in replacement MCCB 215 Amps fixed type, 3 pole, 415 V, breaking capacity 16 kA, connection complete all as specifed and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill.

8

-

-

... More
Suppply & fixing in replacement MCCB 3 pole, 415V, Adjustable Type, 160 Amps,breaking capacity 36 kA, connection complete all as specifed & directed

4

-

-

... More
Suppply & fixing in replacement MCCB 3 pole, 415V, Adjustable Type, 200 Amps,breaking capacity 36 kA, connection complete all as specifed & directed

2

-

-

... More
Suppply & fixing in replacement MCCB 3 pole, 415V, Adjustable Type, 250 Amps,breaking capacity 36 kA, connection complete all as specifed & directed

4

-

-

... More
Suppply & fixing in replacement MCCB 3 pole, 415V, Adjustable Type, 400 Amps,breaking capacity 36 kA, connection complete all as specifed & directed

2

-

-

... More
Suppply & fixing in replacement 3 pole, 415V, Adjustable Type, 630 Amps,breaking capacity 50 kA, connection complete all as specifed & directed. (Note for ser item No 37 to 43 :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill.

1

-

-

... More
Suppply & fixing in replacement analog type time switch FM 1/Quartz daily 240 volts, AC, 50 Hz code J 6107B 204 connection complete all as specifed and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill.

20

-

-

... More
Supply, installation, commissioniong and testing of soft starter suitable for motor capacity 15HP 3 phase 415 Volts 50 Hz with Compact design, with built-in bypass contactor, Essential motor protection, Selectable soft starting profiles, Flexible communication options, Excess start time settling including taking down old starter and related accessories and deposited to MES store yard complete all as specified and directed. (Note:- Old U/s material soft starter obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill.

1

-

-

... More
M&L incls fabrication of glow ditribution diagram of pipeline network including showing of all Pumps, Headers, Valves and pipeline of different sizes etc comprising of printing of complete distribution diagram on Vinyl sheet, weather proof and pasting the same on bakelite sheet min 3 mm thick of size Size 1500mm x 2400mm x 150mm thick fixed on MS frame of similar size made out of square MS Pipe of size 25 mm x 25 mm with proper back lighting for proper illumination and proper color legends for all the feeders, pumps and valves with proper circuit controlled wiring of suitable size and one top plug 3-Pin 5 Amp including fixing the same at the pump house wall and including all fixing material required in replacement complete all as specified and directed. (Note:- Old U/s material glow sign board obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in weight (KG) shall be taken into account and attach with RAR/F Bill.)

2

-

-

... More
Supply, Installation Testing & Commissioning of ULTRASONIC LEVEL SENSORS Water Level Sensor for underground tank suitable for up to 6 meter water level depth of U/G sump, with dead band of less than 0.6meter, IP66 protection, accuracy of 0.25% of F.S. and RS485 Modbus RTU communication protocol, Capable for working in ambient temperature of 0 degree Centigrade to 75 degree Centigrade, non-condensing at 25 degree Centigrade and humidity up to 95% with response time of less than 1 sec with 230VAC to 24VDC, 50Hz power supply, LCD display type, vertical type mounting on top of OHTs with all connections and fixing including clamp, nut-bolt etc in replacement complete all as specified and as directed. (Note:- Old U/s material water level sensor obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill.)

2

-

-

... More
Supply and fixing in replacement 3 pole power contactor ML/MNX-1.5, 25 Amps suitable for fixing in existing panel complete all as specified and as directed.

15

-

-

... More
Supply and fixing in replacement 3 pole power contactor ML/MNX-2, 32-40 Amps suitable for fixing in existing panel complete all as specified and as directed

12

-

-

... More
Supply and fixing in replacement 3 pole power contactor ML/MNX-3, 40-45 Amps suitable for fixing in existing panel complete all as specified and as directed

5

-

-

... More
Supply and fixing in replacement 3 pole power contactor ML/MNX-4, 70-100 Amps suitable for fixing in existing panel complete all as specified and as directed

3

-

-

... More
Supply and fixing in replacement of over load relay, type ML 1.5 relay, range 10-16 Amp complete all as specified and as directed

5

-

-

... More
Supply and fixing in replacement of over load relay, type ML-2 starter range 9-14 Amps complete all as specified and as directed.

5

-

-

... More
Supply and fixing in replacement of over load relay, type ML-2 starter range 13-21 Amps complete all as specified and as directed.

3

-

-

... More
Supply and fixing in replacement of over load relay, type ML-2 starter range 20-32 Amps complete all as specified and as directed.

3

-

-

... More
Supply and fixing in replacement of over load relay, type ML-2 starter range 28-42 Amps complete all as specified and as directed.

6

-

-

... More
Supply and fixing in replacement of over load relay, type MN-12 relay, range 90-150 Amp complete all as specified and as directed.

4

-

-

... More
Supply and fixing in replacement single phase preventor, type VSP-II complete all as specified and as directed. (Note for ser item No 48 to 58 :- Old U/s material contactor & overload relay obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in weight (KG) shall be taken into account and attach with RAR/F Bill.

10

-

-

... More
Supply and fixing rotational moulded polyethylene water storage tank , cylindrical vertical with closed top, 500 ltrs capacity, triple layered hoisted and fixed in position alongwith lid cover after taking down as existing at site (of any capacity) complete all as specified an as directed. (Note: (i) For Pump Priming purpose in pump house. (ii) Old U/s material PVC tank obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of PVC scrap in weight (KG) shall be taken into account and attach with RAR/F Bill.)

2

-

-

... More
Taking down cement plaster or cement lime plaster on PCC/Stone Surface/Brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed .

50

-

-

... More
M&L rendering 15 mm thick in CM (1:4) on fair faces of brickwork or concrete surfaces finished even and smooth complete all as specified and directed .

50

-

-

... More
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoin jambs pillars etc complete all as specified and directed .

2

-

-

... More
M&L Brick work with sub class 'B' old size bricks bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and directed .

2

-

-

... More
Demolition and dismantling concrete in ground floors and pavings n exc 15 cm thickness below or above ground level.

2

-

-

... More
M&L PCC (1:3:6) type C2 using 40mm graded crushed stone aggregate as in foundation for including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed

2

-

-

... More
M&L Machine pressed precast concrete rubber moulded interlocking paverblocks any shape and size confirming to IS 15658-2006 of 60 mm thick, M-30 Grade with grey cement and colour pigments over and including 40 mm thick sand cushioning complete all as specified and as directed. (Note:- Excavation and earth work shall be measured and paid seperately under respective items).

50

-

-

... More
M&L Tank Cover/Valve Chamber Cover made out of mild steel plain sheet of any thickness as in cover for existing valve chamber along with provision of angle iron frame cut to length, bent to shape, welding and fabricate to requiredd shape/ size incl necessary fixing materials like hinges, nut/ bolts etc with two coat of synthetic enamel paint over a coat of red oxide primar and incl lifting handle and taking out the old unsv valve chamber cover complete all as specified and directed. (Note:- Old U/s material cover obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in weight (KG) shall be taken into account and attach with RAR/F Bill.

120

-

-

... More
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 volts LT cables of different sizes from both ends , removal of fault , reconnection and testing of cables after removal of fault complete all as specified and directed by Engr-in-charge. NOTE: (a) 1100 volt cables and joints shall be measured and paid for seperately under respective items of schedule (b) Retrieved old serviceable cable cover/ bricks will be laid in trenches for cable protection. If extra PCC cover / bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Exacavation and earth work will be measured and paid for separately under respective items of schedule (d) DC testing machine report and payment receipt of Electrical department for hiering machine will be kept on record duly verified & signed by EIC.

2

-

-

... More
Supply and fixing in replacement heat shrinkable joint kit suitable for XLPE cable insulated screened PVC bedded armoured electric power cable heave duty 1100 volts grade, with straded aluminium conductor, cross sectional area 25/35 Sqmm, 3.5 core after taking down/out faulty portion as exists compete all as specified and as directed. (Note:- Old U/s material joint kit obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in weight (KG) shall be taken into account and attach with RAR/F Bill.)

4

-

-

... More
M&L fabrication (welding work) of MS Header /any size upto 300 mm MS pipe at various pump house for arresting leakages on header complete all as specified and directed.

2

-

-

... More
Supply and fixing DI MJ Collar fittings all as per IS: 9523 (2000) of following sizes all as specified and directed by Engr-in-Charge.

-

-

-

... More
80 mm dia

4

-

-

... More
100 mm dia

9

-

-

... More
150 mm dia

8

-

-

... More
200 mm dia

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.