Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 85,340Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_686122_1Tender No
GE(U)/PM/D-52/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply and fixing and testing in replacement of three pole power contactors of capacity MNX-18 including NO or NC auxiliary contact block, coil voltage 230 V ,control wiring, thimbles, etc and including taking down of old one complete all as specified and as directed.
30
-
-
... More
Supply and fixing in replacement over load relay 30-50 Amps complete all as specified and directed.
20
-
-
... More
Supply & fixing in replacement brass terminals of follwing ways complete all as specified and directed.
-
-
-
... More
3 way
20
-
-
... More
4 way
30
-
-
... More
6 way
30
-
-
... More
10 way
30
-
-
... More
Material and Labour in replacement of unserviceable 3 way modulating motorized valve with Teflon gland, with linear movement actuator 24 V AC input supply, 0-10 V input signal with modulating thermostat & transformer of following sizes complete all as specified and directed.
-
-
-
... More
32mm dia
5
-
-
... More
65mm dia
5
-
-
... More
50 mm dia
5
-
-
... More
40 mm dia
5
-
-
... More
80 mm dia
5
-
-
... More
100 mm dia
5
-
-
... More
Supply and fixing in replacement cast iron Y strainer flenged ends with SS perforated sheet screen of following size complete all as specified and directed.
-
-
-
... More
100mm dia
5
-
-
... More
150mm dia
5
-
-
... More
200mm dia
2
-
-
... More
32mm dia
5
-
-
... More
65mm dia
5
-
-
... More
50 mm dia
5
-
-
... More
80 mm dia
5
-
-
... More
Supply and fixing in replacement cast iron butter fly valves lever operated SS disc type nitrile/EPDM rubber lining PN 16 of following size dia complete all as specified and directed.
-
-
-
... More
300 mm dia.
1
-
-
... More
200 mm dia.
2
-
-
... More
150 mm dia.
5
-
-
... More
125 mm dia.
5
-
-
... More
100 mm dia.
5
-
-
... More
80 mm dia.
6
-
-
... More
50 mm dia.
6
-
-
... More
65 mm dia
6
-
-
... More
Supply, Laying, jointing and testing of under electric cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed.
-
-
-
... More
3.5 core 70 Sqmm
80
-
-
... More
3.5 core 95 Sqmm
75
-
-
... More
Supply and fixing in replacement motorized spring return actuator for device with control panel and temprature sensor complete all as specified and directed.
30
-
-
... More
Supply and fix in replacement Galvanised iron strip 32X6 mm as earth continuity conductor including fixing arrangement on suitable size insulator complete all as directed.
120
-
-
... More
Material and Labour earthing complete with GI plate electrode of size 600 x 600 x 6 mm thick bured directly in ground vertically at a depth not less 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level surrounded from all sides by 1.5 cm thick packed layer of charcoal of dust and common salt filling in alternate layers and making electrode connection by using GI strip of size 32X6 (up to 7 meter GI strip included) mm by means of bolts nuts check nuts and washers made of brass and earth strip protected by light grade 40 mm dia GI Pipe upto test point and connected to main switch board are main controlled board with provision of GI pipe medium grade 20mm bore for watering including funnel wire mass RCC pit cover and PCC Chamber pit with 1:2: 4 type C2 (including excavation earth work) all as specified and shown on plate No 5 of SSR Part-1.
20
-
-
... More
Supply and fixing in replacement 80 mm dia cast iron non return valves of pressure class PN 1.6 including nuts, bolts, washers, gaskets, etc for Central type AC plants complete all as specifed and directed.
1
-
-
... More
ditto- all as per item No. 14.00 above but 100mm dia
1
-
-
... More
ditto- all as per item No. 14.00 above but 150mm dia.
1
-
-
... More
Ditto- all as per item No. 14.00 above but 250mm dia.
1
-
-
... More
Supply, Installation , Testing and commissioning in repair of perfabricated type cable tray of size 45mm wide x 50mm x 1.6mm fabricated out of perforated hot dip galvanized sheet of minimum 1.6mm thick with 50mm flange to be installed horizontally or vertically. The cable tray shall be complete including cost of bends, elbows, cross, tees, reducers etc. site condition and rate shall include cost of anchor fastners, screw, nuts, bolts and misc. and other fixing hardware painting of support structure etc as required complete all as specified and as directed.
50
-
-
... More
All as per Item No. 18.00 above but of size 75mm wide x50mm x 1.6mm complete all as specified and as directed.
40
-
-
... More
All as per Item No. 18.00 above but of size 150mm wide x50mm x 1.6mm complete all as specified and as directed.
30
-
-
... More
Material and Labour for cutting of existing MS/GI water mains of size 80 mm dia of chiller/condensor/cooling towers & GI pipes of make-up tanks of central AC plant at different points/section for replacement with new MS pipe in short lengths including MS fittings complete all specified and as directed.
2
-
-
... More
All as per item No. 21 here-in-before but of size 100 mm.
2
-
-
... More
All as per item No. 21 here-in-before but of size 125 mm.
2
-
-
... More
All as per item No. 21 above but of size 150 mm.
2
-
-
... More
Taking out old unserviceable MS pipes and Supplying & laying , commissioning & testing mild steel (Heavy) 'C' class pipe of size 80 mm dia on exposed surface / underground (in trenches) including welding works, connections with existing chilled water line, chiller, pump, fabrication of bends, MS flange, tees, reducers, shoe, support (brick masonry block & wooden support for underground / MS angle- clamp & wooden support for exposed surface) along with priming coat of steel primer as per standard specification complete all specified and as directed. Note:- (i) The rates quoted by the contractor shall deemed to include the cost of MS fittings required during laying of MS Pipes. (ii) The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be heavy class of thickness min. 7mm as per IS: 3589. (iii) Cost of excavation, returning, filling and removing shall be paid separately under relevant item.
100
-
-
... More
All as per item No. 25 here-in-before but of size 100 mm.
100
-
-
... More
All as per item No. 25 here-in-before but of size 125 mm.
120
-
-
... More
All as per item No. 25 here-in-before but of size 150 mm.
150
-
-
... More
Material and Labour for replacement of chilled water or refrigerent MS class 'C' pipe insulation inside the building but excluding valves/strainers/pr gauges etc and adequately supported on rigid supports and duly insulated with closed cell elastometric nitrile rubber of class 'O' insulation and insulation applied by adhesive confirming to standard OEM specifications secured with 0.63 mm GI sheet cladding complete at the joints and repairing of damage to the buildings if any etc as per specifications and as required complete in all respects.The size of pipes and insulation shall be as shown below:-
-
-
-
... More
50 mm Pipe (32mm thick insulation)
120
-
-
... More
65 mm Pipe (32mm thick insulation)
110
-
-
... More
80 mm Pipe (40mm thick insulation)
100
-
-
... More
100 mm Pipe (40mm thick insulation)
100
-
-
... More
125 mm Pipe (40mm thick insulation)
100
-
-
... More
150 mm Pipe (40mm thick insulation)
90
-
-
... More
200 mm Pipe (40mm thick insulation)
15
-
-
... More
250 mm Pipe (40mm thick insulation)
15
-
-
... More
Taking out all electrical connections of old unserviceable motor with pump of any capacity, supply & fix new motor pump for chiller /conderser pumps of capacity 10 HP, 3 phase, 440+ 10%, 50 Hz, 1400-1500 RPM, IP-55, 4 Pole protected with suction and discharge as per existing at site including necessary arrangements for mouting on existing angle iron frame, nuts, bolts and washers of suitable size, connecting with the existing frame and pump complete all as specified and as directed.
3
-
-
... More
Taking out all electrical connections of old unserviceable squirrel cage motor of any capacity, supply & fix new squirrel cage induction motor of capacity 7.5 HP, 3 phase, 440+ 10%, 50 Hz, 1400-1500 RPM, IP-55, 4 Pole protected including necessary arrangements for mouting on existing angle iron frame, nuts, bolts and washers of suitable size, connecting with the existing AHU blower complete all as specified and as directed.
3
-
-
... More
Taking out all electrical connections of old unserviceable squirrel cage motor of any capacity, supply & fix new squirrel cage induction motor of capacity 20 HP, 3 phase, 440+ 10%, 50 Hz, 1400-1500 RPM, IP-55, 4 Pole protected including necessary arrangements for mouting on existing angle iron frame, nuts, bolts and washers of suitable size, connecting with the existing AHU blower complete all as specified and as directed.
2
-
-
... More
Taking out all electrical connections of old unserviceable squirrel cage motor of any capacity, supply & fix new squirrel cage induction motor of capacity 15 HP, 3 phase, 440+ 10%, 50 Hz, 1400-1500 RPM, IP-55, 4 Pole protected including necessary arrangements for mouting on existing angle iron frame, nuts, bolts and washers of suitable size, connecting with the existing AHU blower complete all as specified and as directed.
2
-
-
... More
Taking out all electrical connections of old unserviceable squirrel cage motor of any capacity, supply & fix new squirrel cage induction motor of capacity 10 HP, 3 phase, 440+ 10%, 50 Hz, 1400-1500 RPM, IP-55, 4 Pole protected including necessary arrangements for mouting on existing angle iron frame, nuts, bolts and washers of suitable size, connecting with the existing AHU blower complete all as specified and as directed.
3
-
-
... More
Taking out all electrical connections of old unserviceable squirrel cage motor of any capacity, supply & fix new squirrel cage induction motor of capacity 3 HP, 3 phase, 440+ 10%, 50 Hz, 1400-1500 RPM, IP-55, 4 Pole protected including necessary arrangements for mouting on existing angle iron frame, nuts, bolts and washers of suitable size, connecting with the existing AHU blower complete all as specified and as directed.
3
-
-
... More
Taking out all electrical connections of old unserviceable squirrel cage motor of any capacity, supply & fix new squirrel cage induction motor of capacity 5 HP , 3 phase, 440+ 10%, 50 Hz, 1400-1500 RPM, IP-55, 4 Pole protected including necessary arrangements for mouting on existing angle iron frame, nuts, bolts and washers of suitable size, connecting with the existing AHU blower complete all as specified and as directed.
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%