Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date31 Aug 2024
Closing Date28 Sep 2024
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ or otherwise called Price Bid or Sch A
It is compulsory for the contractor - Phase 1 material is to be procured within 30 days after issuance of Work Order 1
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Semi UG sump of capacity 200000 GLNS at GE office complete all as specified and directed by Engr-in-charge.

2

-

-

... More
OH tank of capacity 106000 GLNS at Tech area complete all as specified and directed by Engr-in-charge.

1

-

-

... More
Semi UG sump of capacity 50000 GLNS at VSB complete all as specified and directed by Engr-in-charge.

3

-

-

... More
Semi UG sump of capacity 30000 GLNS at VSB complete all as specified and directed by Engr-in-charge.

1

-

-

... More
OH tank of capacity 150000 GLNS at VSB complete all as specified and directed by Engr-in-charge.

1

-

-

... More
SWT of capacity upto 5000 Glns at Tech Area and VSB area complete all as specified and directed by Engr-in-charge.

13

-

-

... More
HDPE tank of capacity 5000Ltrs to 10000 Ltrs at VSB area complete all as specified and directed by Engr-in-charge.

21

-

-

... More
HDPE tank of capacity 2000Ltrs at VSB & Tech Area complete all as specified and directed by Engr-in-charge.

5

-

-

... More
HDPE tank of capacity 1000Ltrs at VSB & Tech Area complete all as specified and directed by Engr-in-charge.

30

-

-

... More
M&L for painting with black enamel paint of SWT angle iron cover mesh after applying one coat of red oxide after scrapping, complete all as specified and directed by Engr-in-charge.

6

-

-

... More
S&F in replacement of garden Green net of 1.5mtrs wide to cover SWT over angle iron mesh, complete all as specified and directed by Engr-in-charge.

40

-

-

... More
S&F in replacement of Float Valve /Ball valves high pressure of PTMT of 15 MM dia with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed, complete all as specified and directed by Engr-in-charge.

30

-

-

... More
All as per item: 4 above but of size 20 mm dia, complete all as specified and directed by Engr-in-charge.

30

-

-

... More
All as per item: 4 above but of size 25 mm dia, complete all as specified and directed by Engr-in-charge.

30

-

-

... More
All as per item: 4 above but of size 50 mm dia, complete all as specified and directed by Engr-in-charge.

30

-

-

... More
M&L for Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position of any capacity complete all as specified and directed by Engr-in-charge.

12

-

-

... More
S&F of Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 5000Ltr hoisted and fixed in position all as specified in SSR Part I, complete all as specified and directed by Engr-in-charge.

4

-

-

... More
All as per item: 9 above but of capacity 2000Ltrs, complete all as specified and directed by Engr-in-charge.

2

-

-

... More
All as per item: 9 above but of capacity 1000Ltrs, complete all as specified and directed by Engr-in-charge.

6

-

-

... More
S&F replacement of HDPE water tank cover suitable for 5000Ltr capacity tank, complete all as specified and directed.

20

-

-

... More
S&F replacement of HDPE water tank cover suitable for 2000Ltr capacity tank, complete all as specified and directed.

20

-

-

... More
S&F replacement of HDPE water tank cover suitable for 1000Ltr capacity tank, complete all as specified and directed.

20

-

-

... More
M&L for demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) for HDPE tank foundations, complete all as specified and directed by Engr-in-charge.

2

-

-

... More
S&F M-Seal suitable for pipe jointing, complete all as specified and directed by Engr-in-charge.

3

-

-

... More
M&L for hard core of broken stone or boulders of gauge n.exc. 63mm deposited spread and levelled in layers n.exc. 15 cm thick watered and rolled/ rammed to a true surface complete all as specified and directed by Engr-in-charge.

2

-

-

... More
M&L for Cement concrete in foundations, filling and mass concrete of Type C2 (1:3:6), (40 mm graded aggregate) for 5000Ltrs HDPE tank foundation, motor foundation etc. complete all as specified and directed by Engr-in-charge.

3

-

-

... More
Supply and fixing in repair of pre-fabricated MS structural steel (IS marked) work consisting of channels / angles /flats/ round bars/MS pipe & other sections etc of various sizes and shape, cut / weld / drilled holes etc hot / cold in position for cross arms with FI clamps (full, half D and earth clamp etc) incl necessary MS bolts, nuts etc and painting for hanging strcture for repair bay complete all as specified and directed by Engr-in-charge.

40

-

-

... More
S&F in replacement of pre-painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/clading to wall, fixed with self tapping screws and bending of sheet as required and as directed by Engineer-in-Charge.

10

-

-

... More
Supply and laying in replacement of galvanised steel water tubing medium grade in trenches / wall /floor with all fittings , connections as required at site of size 15 mm bore, complete all as specified and directed by Engr-in-charge.

60

-

-

... More
All as per Item No 21 Above but Bore of pipe 20 mm, complete all as specified and directed by Engr-in-charge.

100

-

-

... More
All as per Item No 21 Above but Bore of pipe 25 mm, complete all as specified and directed by Engr-in-charge.

100

-

-

... More
All as per Item No 21 Above but Bore of pipe 50mm, complete all as specified and directed by Engr-in-charge.

100

-

-

... More
S&F in replacement of Stop valve gun metal valve with iron handle screwed both ends for iron pipe and fixed of size 15 mm bore, complete all as specified and directed by Engr-in-charge.

20

-

-

... More
All as per Item No 25 Above but Bore of pipe 20mm, complete all as specified and directed by Engr-in-charge.

20

-

-

... More
All as per Item No 25 Above but Bore of pipe 25mm, complete all as specified and directed by Engr-in-charge.

20

-

-

... More
All as per Item No 25 Above but Bore of pipe 50mm, complete all as specified and directed by Engr-in-charge.

20

-

-

... More
S&F in replacement of 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) of size 63mm outer dia of pipe UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors or in trenches, complete all as specified and directed by Engr-in-charge.

50

-

-

... More
S&F in replacement of PP-R Gate valves (brass insert) of size 63mm dia as per requirement of the site, complete all as specified and directed by Engr-in-charge.

15

-

-

... More
M&L for Cutting existing steel tubing/PPR tubing for alterations or additions for 40/50mm dia pipe complete all as specified and directed by Engr-in-charge.

10

-

-

... More
M&L for Cutting existing steel tubing/PPR tubing for alterations or additions for 25mm dia pipe complete all as specified and directed by Engr-in-charge.

15

-

-

... More
M&L for Cutting existing steel tubing/PPR tubing for alterations or additions for 20mm dia pipe complete all as specified and directed by Engr-in-charge.

20

-

-

... More
M&L for servicing of Chloronome plant by oiling greasing, gland dori, gasket, motor fan, replacing unserviceable bearings, removing dealignement of agitaor shaft, locking keys, blades, servicing of dosing pumps, detecting & fixing minor faults, replacing u/s knob and push buttons etc. complete all as specified and directed by Engr-in-charge.

10

-

-

... More
S&F in replacement of chlorine dosing pump of capacity 0-10LPH, minimum 3.5-4.5 Kg/cm2 dosing pressure, 6mm suction tube, 23watt, 230V AC, 50Hz & stoke control system including all connected items, complete all as specified and directed by Engr-in-charge.

5

-

-

... More
M&L for rewinding of chlorine agitator induction motor of capacity upto 1.5HP, 1410rpm, 3 phase, 415 V, 50 Hz of any make with copper conductor of the same specification as per old one after dismantling / cutting out burnt windings from stator assembly, cleaning slots complete all as specified and directed by Engr-in-charge.

5

-

-

... More
M&L for in replacement of chlorine agitator induction motor of capacity upto 1.5HP, 1410rpm, 3 phase, 415 V, 50 Hz of any make with copper conductor of the same specification complete all as specified and directed by Engr-in-charge.

3

-

-

... More
S&F in replacement of chlorine agitator motor worm gear box assembly suitable for agitator of capacity 1.5HP, 3phase, made of Steel, 90 degree mounting flange fixed Suitable for motor as per site requirement, complete all as specified and directed by Engr-in-charge.

5

-

-

... More
S&F in replacement of Chlorine agitator shaft & blades along with locking key arrangment made of Solid SS rod of length not less than 1mtr including bush/bearing for support & guided rotation all as per required at site complete all as specified and directed by Engr-in-charge. Note: Any lath work, gears, bush bearing required for mounting with agitator is deemed to be included in quoted rates.

5

-

-

... More
S&F in replacement Three phase Direct on line starter of capacity 1.5 HP overload relay range 1.50-2.5 Amp complete all as specified and directed by Engr-in-charge.

5

-

-

... More
S&F in replacement of heavy duty PVC suction& discharge pipe of 6mm dia along with connectors, complete all as specified and directed by Engr-in-charge.

50

-

-

... More
S&F in replacement of MCB TPN 10KA , 'C' curve, 40-63Amp, complete all as specified and directed by Engr-in-charge.

21

-

-

... More
All as per item: 42 above but, TP, 40-63Amp, complete all as specified and directed by Engr-in-charge.

21

-

-

... More
All as per item: 42 above but, DP, 40-63Amp, complete all as specified and directed by Engr-in-charge.

15

-

-

... More
All as per item No: 42 above but SP 6-32Amps, complete all as specified and directed by Engr-in-charge.

30

-

-

... More
S&F in replacement of PVC insulated Copper cable of 2.5Sqmm 3 core complete all as specified and directed by Engr-in-charge.

200

-

-

... More
S&F in replacement motor cover made of FRP sheets 3mm thick in U shape with handle for lifting including fastner, nut bolts as required on site suitable for monoblock pumpset upto 5HP, complete all as specified and directed by Engr-in-charge.

10

-

-

... More
M&L for visiting of service engineer/ technician at site and inspecting DG set upto 250 KVA (including AMF panel problems, control unit/sensors, Engine, radiator, Alternator or any other type of complaint i.e. Mechanical, electrical or electronic or including all the three teams togather) and checking for fault/defect and noting down items required for rectification, including rectifying minor defect on site if possible, complete all as specified and directed by Engr-in-charge. Note: (i) visit for servicing of DG set will not be considered in this item. (ii) Minor complaints occuring within one month after servicing of a particular DG set will not be considered in this item after lodging complaint to Contractor by Engineer-in-charge or JE. (iii) Visiting of Different technician i.e. electrical, mechanical, electronic or combine of three for the same complaint will be considered as one visit or one complaint only. (iv) Subsequent visit after first visit (defect found or not), if founded then visit for rectification of defect will not be considered in this item.

50

-

-

... More
M&L for Carry out 'B' check and servicing of DG set as per OEM specification for DG set of 100 KVA capacity, (including the cost of the following spares (quantity) as per make/OEM and as directed by Engineer in Charge. (i) Engine oil (ii) lube oil filter (iii) Fuel Filter Kit 1.1 Ltrs (iv) Coolant (v) Air cleaner Safety Element (vi) Air cleaner primary element (vii) K clean 1 ltrs (viii) Poly V belt 4PK/8PK (any type & length) (ix) Thermostat Element (x) Rubber hoses of any type with tie clips of suitable size (xi) Gaskets,glands, nut, bolts & washers (xii) Radiator cleaning from outside with pressure jet spray, chemical & brush (xiii) Cleaning of DG set engine within canopy and AMF panel (xiv) Freight & labour charges

3

-

-

... More
All as per item No-49 above but for below 40- 62.5 KVA DG set complete all as specified and directed by Engr-in-charge.

3

-

-

... More
Dismantling of radiator assembly of DG Set upto 100 KVA capacity, and transporting it to workshop (if required) from site otherwise performing job at site. thereafter cleaning fins and chocked tubes after draining out water, washing with caustic, descaling and brazing for water tube leakage, repalcing of copper tube of suitable length and and size and refixing the same properly by deploying sufficient numbers of labour and commissioning and again checking for leakage after running DG on Load and checking flow speed of water through it, complete all as specified and directed by Engr-in-charge. Note: Transportation charges are deemed to be included in quoted rates.

4

-

-

... More
Dismantling of Fuel pump assembly and fuel injectors of any nos of engine for DG Set of capacity upto 100 KVA, and transporting it to workshop and Caliberation fuel pump & its fuel injection system and overhauling of pump valve, valve seat, Nozzel pin holes by metal deposition and machining on lathe machine, gasket, bolts etc. and refixing the same and commissioning till fuel consumption and quality & quantity of smoke is within permissible level complete all as specified and directed by Engr-in-charge. Note: Transportation charges are deemed to be included in quoted rates.

4

-

-

... More
Dismantling of Self Starter motor of any capacity for DG Set of capacity upto 100 KVA (Suitable for 12 V), and transporting it to workshop and rewinding with suitable gauge of copper wire, overhauling, repair & replacement of gears, pinion & its locking arrangment, armature, Carbon plate, carbon bush & brush, Gears etcand and refixing the same and commissioning for the torque developed by it for starting DG Set, complete all as specified and directed by Engr-in-charge. Note: Transportation charges and charges for dismantling & reconnecting electric cable of starter & synchronising with control unit are deemed to be included in quoted rates.

4

-

-

... More
S&F in replacement of AVR S/F VARIABLE SPEED DCDG suitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage for DG set upto 100 KVA as per OEM specifications, including wiring as per required at site complete all as specified and directed by Engr-in-charge.

4

-

-

... More
M&L for cutting and removing burnt out AMF panel wiring and rewiring it with copper wire of solid/stranded conductor all as per existing size with proper labelling/tagging, new thimble/ termination, connecting all circuit & logical controls, repalcing relays, timers, sensors & signal reciever, removing carbon deposition on bus bars & terminals, repairing cable tray, rewiring and proper connection of AMF panel parameters with DG set safety control unit, replacing new CTs etc. Testing and commission of AMF panel in auto and manual mode and demostrating the functionality of all the safety parameter both from saftey control panel and AMF panel complete all as specified and directed by Engr-in-charge. NOTE: wiring, CTs, thimble, tagging, rewiring of DG set mounted safety control unit etc required are deemed to be in quoted rates.

3

-

-

... More
Supply and fixing of digital VAF + PF meter, Class 1.0 in square in size of 96mm x 96mm cross-section for DG sets suiatble for DG set upto 100 KVA, complete all as specified and directed by Engr-in-charge.

3

-

-

... More
Supply and fixing of DC Ammeter 0-30Amps of square in size of 96mm x 96mm cross-section, for DG sets suiatble for DG set upto 100 KVA, complete all as specified and directed by Engr-in-charge.

3

-

-

... More
Supply and fixing digital RPM meter as per site suiatble for DG set upto 100 KVA, complete all as specified and directed by Engr-in-charge.

3

-

-

... More
Supply and fixing of 'under/over voltage relay, 3 phase, 415 volts', for DG sets of capacity upto 100 KVA complete all as specified and directed by Engr-in-charge.

3

-

-

... More
Supply and fixing of 'under/over voltage relay, single phase, 240 volts', (set of 3 for each phase in one panel) for DG sets of capacity upto upto 100 KVA, complete all as specified and directed by Engr-in-charge.

3

-

-

... More
Supply and fixing of battery voltage relay 12/24 VDC suiatble for DG set upto 100 KVA, complete all as specified and directed by Engr-in-charge.

3

-

-

... More
Supply and fixing Three element overcurent and earth fault relay as per site suiatble for DG set upto 100 KVA, complete all as specified and directed by Engr-in-charge.

3

-

-

... More
Supply and fixing frequency relay as per site suiatble for DG set upto 100 KVA, complete all as specified and directed by Engr-in-charge.

3

-

-

... More
Supply and fixing engine start relay as per site suiatble for DG set upto 100 KVA, complete all as specified and directed by Engr-in-charge.

3

-

-

... More
Supply and fixing speed relay as per site suiatble for DG set upto 100 KVA, complete all as specified and directed by Engr-in-charge.

3

-

-

... More
S&F ammeter selector switch, 6 A, rotary type, single hole inerted, with display plate suitable for 250 KVA DG set, complete all as specified and directed by Engr-in-charge.

4

-

-

... More
S&F 3 phase Voltmeter selector switch, 6 A, rotary type, single hole inerted, with display plate suitable for 250 KVA DG set, complete all as specified and directed by Engr-in-charge.

4

-

-

... More
S&F 2 step selector switch, 16 A, rotary type, single hole inerted, with display plate suitable for 250 KVA DG set, complete all as specified and directed by Engr-in-charge.

4

-

-

... More
Supply and fixing LED lamp of any colour (Red, yellow, green and blue) suitable for 12/24 v DC & AC for DG sets of capacity upto 100 KVA, complete all as specified and directed by Engr-in-charge.

5

-

-

... More
Supply and fixing 160 Amp, 415 Volts, 50 Hz Power contactor of coil voltage 415 Volts, including spring operated add-on block and spring operated locking block along with spread suitable to bear current upto 250 Amps complete all as specified and directed by Engr-in-charge.

3

-

-

... More
All as per srl item No - 70 but of 100 Amp, 415 Volts, 50 Hz Power contactor, spreader suitable to bear current upto 300 Amps complete all as specified and directed by Engr-in-charge.

3

-

-

... More
M&L in replacement for MCCB 4 pole 160 amps, thermal adjustable magnetic type, 25 KA complete all as specified and directed by Engr-in-charge.

8

-

-

... More
M&L in replacement for MCCB 4 pole 100 amps, thermal adjustable magnetic type, 35 KA complete all as specified and directed by Engr-in-charge.

9

-

-

... More
Supply and fixing battery charger 24 VDC 10 AMP with 3 mode of operation (floated, boost & manual) including complete wiring, complete all as specified and directed by Engr-in-charge.

6

-

-

... More
S&F in replacement of DG set acoustic enclosure door lock/ door hinges suitable for capacity 30 KVA to 180 KVA complete all as specified and directed by Engr-in-charge.

6

-

-

... More
S&F in replacement of unserviceable water pump assembly rating upto 180 KVA DG set all as specified and directed by Engr-in-charge.

6

-

-

... More
Supply and fixing in replacement of Pre wired Engine safety unit (ESU) for DG set of capacity upto 100 KVA complete all as specified and directed by Engr-in-charge.

6

-

-

... More
Dismantling existing fuel injection pump of DG set of capacity from 30KVA to 180 KVA, transporting to work shop and servicing complete including replacement of plunger, spring,nozzle assembly, calibrating and re-fixing the same and testing the DG Set to the entire satisfaction of Engineer-in-charge.

6

-

-

... More
Supply and fixing in replacement of oil sensor complete all as specified and directed by Engr-in-charge.

6

-

-

... More
Supply and fixing in replacement of unserviceable water line socket for capacity upto 180 KVA complete all as specified and directed by Engr-in-charge.

5

-

-

... More
Supply and fixing in replacement of unserviceable Turbo charger kit upto 180 KVA DG set complete all as specified and directed by Engr-in-charge.

4

-

-

... More
Supply & Fixing in replacement of PVC insulated with standard copper conductor cable 2 mtrs length, 10 Sqmm suitable for 150 AH 240 volts DC battery, complete all as specified and directed by Engr-in-charge.

6

-

-

... More
S&F in replacement of brass terminals for battery upto 150 Ah, complete all as specified and directed by Engr-in-charge.

12

-

-

... More
Supply only distilled water in one litre container complete all as specified and directed by Engr-in-charge.

60

-

-

... More
Dismantling Oil Pressure gauge of DG set , supply and fix the same and testing complete all as specified and directed by Engr-in-charge.

6

-

-

... More
Supply & Fixing in replacement lead acid battery of 12 volts capacity 150 AH complete all as specified and directed by Engr-in-charge.

7

-

-

... More
M&L for dismantling alternator of DG set upto 100 KVA and transporting it to workshop and rewinding with suitable gauge of copper wire, overhauling & replacement of gear, pinion, pulley, carbon brush & brush etc as per OEM specification including wiring & refixing at site complete all as specified and directed by Engr-in-charge.

4

-

-

... More
S&F in replacement of stop solenoid assembly vertical mounted S/F C lever 12V with spring (energies to run) all as per OEM specification including electrical & sensor connection, complete all as specified and directed by Engr-in-charge.

4

-

-

... More
supply & filling lubrication oil 20W40 for DG set as per manufacturer's recommendation for topping up as and when required at site complete all as specified and directed by Engr-in-charge.

200

-

-

... More
Supply and filling coolent for radiator as per manufacturer's recommendation for topping up as and when required at site complete all as specified and directed by Engr-in-charge.

60

-

-

... More
S&F in replacement of flexible lube oil pipe as per OEM specification and site requirement complete all as specified and directed by Engr-in-charge.

30

-

-

... More
S&F in replacement of heavy duty V Belt of any type in DG set set upto 100KVA as per DG model at site, complete all as specified and directed by Engr-in-charge.

15

-

-

... More
S&F in replacement of Monoblock pumpset 1HP, 25x25mm cross section pipe, head range - 6-39m, discharge 3000-750LPH, 2780 RPM complete all as specified and directed by Engr-in-charge.

2

-

-

... More
S&F Radiator fan suitable for DG set upto 100 KVA along with locking key as per OEM specification, complete all as specified and directed by Engr-in-charge.

3

-

-

... More
S&F Fuel spray injectors suitable for DG set upto 100 KVA specification, complete all as specified and directed by Engr-in-charge.

20

-

-

... More
S&F in replacement of PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt 1.5 Sqmm 12 core for connection with ESU and AMF panel, complete all as specified and directed by Engr-in-charge.

60

-

-

... More
Material and labour in replacement of earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 25×4mm mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt all around earth plate, PCC (1:3:6) type C-1 (using 40mm graded stone aggregate), angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI medium grade earth lead protection pipe, complete all as specified and directed by Engr-in-charge. NOTE : Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of BoQ.

10

-

-

... More
All as above item No: 97 but for galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel, complete all as specified and directed by Engr-in-charge.

5

-

-

... More
M&L for dismantling of old existing earthing PCC earthing pit with cover and new construction of earthing PCC earthing pit with new polyplastic earth pit cover heavy duty with sign board triangular shape, making connection of earth strip including minor adjustment, construction of rectangular of size 0.75 X0.75x .50 (LXBXH) brick boundary alongwith necessary plastering work with specified colour coding around poly plastic earth pit cover, complete all as specified and directed by Engr-in-charge.

40

-

-

... More
M&L for Two coat of apex emulsion painting of Earthing pit in existing colour or complete all as specified and directed by Engr-in-charge.

60

-

-

... More
M&L for GI brazing (welding) at site to connect loop GI earthing strip of any size after tighten by nut, bolt, washer, checknuts all as specified and as directed by Engr-in-charge. Note: GI brazing should be done upto 20 mtr height. Cost of necessary tool/plant and ladder required for working upto 20 mtr height shall be deemed to be included in the rate quoted.

60

-

-

... More
M&L for dismantling the strip from earth pit and testing of earth pit to be done as per fall of potential method mentioned in IS-3043 with digital earth resistance tester to check the healthiness of earthing system in and including replacement earth pit nut bolts with brass nut bolts as per required size and record should be kept on ledger duly signed by user representative and submitted to Engr in charge, complete all as specified and directed by Engineer-in-Charge. Note: The testing of earth pit shall be done as and when required basis as directed by Engineer-in-Charge from time to time.

60

-

-

... More
Supply and fixing in replacement 25x4 mm GI strip in short pieces on surface or in recess for all interconnecting, in and complete all as specified and directed by Engr-in-charge.

100

-

-

... More
Supply and fixing in replacement 4 Sqmm GI wire in short pieces on surface or in recess for all interconnecting, in complete all as specified and directed by Engr-in-charge.

100

-

-

... More
Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete all as specified and directed by Engr-in-charge.

35

-

-

... More
M&L for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft soil, complete all as specified and directed by Engr-in-charge.

10

-

-

... More
M&L dry clean river sand for cushioning in trenches for protection of under ground cable including watering and consolidation complete all as specified and directed by Engr-in-charge.

10

-

-

... More
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete all as specified and directed by Engr-in-charge.

1800

-

-

... More
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point complete all as specified and directed by Engr-in-charge.

5

-

-

... More
Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed by Engr-in-charge.

20

-

-

... More
M&L in replacement for panel inbuilt change over switch 160A, 4 pole, open execution, Phase Barriers & Handle with door interlock kit is integral part of the Changeover Switch, complete all as specified and directed by Engr-in-charge.

3

-

-

... More
M&L in replacement for panel inbuilt change over switch 100A, 4 pole, open execution, Phase Barriers & Handle with door interlock kit is integral part of the Changeover Switch, complete all as specified and directed by Engr-in-charge.

2

-

-

... More
M&L in replacement for MCCB 3 pole 160 amps, thermal adjustable magnetic type, 25 KA complete all as specified and directed by Engr-in-charge.

5

-

-

... More
M&L in replacement for MCCB 3 pole 100 amps, thermal adjustable magnetic type, 35 KA complete all as specified and directed by Engr-in-charge.

6

-

-

... More
M&L in replacement for MCCB 3 pole 63 amps, thermal adjustable magnetic type, 35 KA complete all as specified and directed by Engr-in-charge.

10

-

-

... More
M&L in replacement for MCCB 4 pole 250 amps, thermal adjustable magnetic type, 50 KA complete all as specified and directed by Engr-in-charge.

4

-

-

... More
M&L in replacement for MCCB 4 pole 350 amps, thermal adjustable magnetic type, 50 KA complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Supply and Laying in replacement of cable XLPE insulated screened PVC bedded, galavanised steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of following sizes :-

-

-

-

... More
95 sqmm 3.5 core.

60

-

-

... More
70 sqmm 3.5 core.

60

-

-

... More
50 sqmm 3.5 core.

80

-

-

... More
35 sqmm 3.5 core.

150

-

-

... More
25 sqmm 4 core.

150

-

-

... More
16 sqmm 4 core.

30

-

-

... More
10 Sqmm 2 core

30

-

-

... More
S&F in repair of GI tubing 'Light' grade for cable protection fixed in poles/walls/laid under roads/crossing etc OF 80mm dia complete all as specified and directed by Engr-in-charge.

20

-

-

... More
S&F in repair of GI tubing 'Light' grade for cable protection fixed in poles/walls/laid under roads/crossing etc OF 50mm dia complete all as specified and directed by Engr-in-charge.

30

-

-

... More
M&L for defect rectification 1.1 KV cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additional excavation in normal alluvial strata required for exposing the cable fault; removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of size up to 95 Sq mm 3.5 core. The fault locating equipments will be brought to site within the hours complete all as specified and directed by Engr-in-charge.

8

-

-

... More
M&L for heat shrinkable 1.1KV XLPE cable outdoor termination, complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50sqmm, complete all as specified and directed by Engr-in-charge.

5

-

-

... More
M&L for heat shrinkable 1.1KV XLPE cable outdoor termination, complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 150sqmm, complete all as specified and directed by Engr-in-charge.

5

-

-

... More
Supplying and laying in replacement of synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed by Engr-in-charge.

10

-

-

... More
S&F in replacement 150 Watt LED floodlight made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection, complete all as specified and directed by Engr-in-charge.

2

-

-

... More
S&F in replacement with Powder coated pressure die cast aluminium compact LED Street light/building lighting of 45 watt with toughened glass and high power LEDs with option of secondary optic with IP65 protection complete all as specified and directed by Engr-in-charge.

3

-

-

... More
S&F in replacement of copper cable 1.5 Sqmm, 3 core PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt complete all as specified and directed by Engr-in-charge.

100

-

-

... More
All as above item No: 134, but of 16 sqmm 3 core, complete all as specified and directed by Engr-in-charge.

50

-

-

... More
S&F heavy duty PVC cable, 1100 volts grade insulated aluminium stranded conductor, twin core wire of size 10 sqmm complete all as specified and directed by Engr-in-charge.

60

-

-

... More
Supply and fix in repair of rubber coupling suitable for 20 to 65 HP pump set as per existing pattern complete all as specified and directed by Engr-in-Charge.

12

-

-

... More
M&L for minor repairing / rectified and attending the complaint of LT panels by skilled tradesmen and making functional including fixing panel accessories, MCCB, MCB etc as required at site complete all as specified and directed by Engr-in-charge.

25

-

-

... More
M&L for taking proper shut down from substation and servicing the LT panel board of any type (indoor/Out door) make complete with removal of dust reconnection of all incoming and outgoing cable with proper gland replacemnet of all nut bolds and washers repalcement of control wiring including insulation tapping with colour coding replacement of burned aluminium bus bars, fixing of LT panel front and back door covers on hinges complete with cutting ,welding ,grinding etc and providing porper locking arrangements ext complete all as specified and directed by Engr-in-charge. Note : (a) Cost for replacement of minor spares are deemed to be included in the quoted rates. (b) The rates shall be deemed to be included for replacement of worn out rusted, Channels, hinges, bolts, split pins and cable lugs, cable glands and neoprene gasket to all doors including raising of foundation to 300cm height etc. (c) Cost of replacement of MCCB's, Repairs to ACB's not included in the scope of work. (d) Cost of replacement of defective CT's, Ammeter, Voltmer and indication lamps will be paid in separate items.

10

-

-

... More
M&L in replacement of ampere meter digital type, 415V suitable for existing panel CT operated of range 0-100 as required complete all as specified and directed by Engr-in-charge.

10

-

-

... More
M&L in replacement of ampere meter digital type, 230V suitable for existing panel CT operated of range 0-100, complete all as specified and directed by Engr-in-charge.

10

-

-

... More
M&L in replacement of voltmeter digital type, 415V suitable for existing panel CT operated of range 0-500, complete all as specified and directed by Engr-in-charge.

10

-

-

... More
M&L in replacement of LED indicator lamp, complete all as specified and directed by Engr-in-charge.

10

-

-

... More
M&L in replacement of panel mounted ON/OFF push button with contact block, complete all as specified and directed by Engr-in-charge.

10

-

-

... More
M&L in replacement of CT 100/5 complete all as specified and directed by Engr-in-charge.

12

-

-

... More
S&F in replacement of LT panel connetor suitable for stater & MCCB connection made of heavy duty plastic with ss nut & bolt suitable for upto 50Amp, 215volts as per site requirement complete all as specified and directed by Engr-in-charge.

20

-

-

... More
M&L for Removal of the existing paint from the LT panel of any size by the hand scrapping and painting LT panel of any type or size with two coats of synthetic enamelled grey paint over a coat of red oxide primer including preparation of old painted surface complete all as specified and directed by Engr-in-charge.

10

-

-

... More
Taking down old unserviceable and S&F standard duty power capacitor 440 V 3 phase LTBCD series 1 to 30 KVAr, box type for APFC panel of any capacities including wiring and connection with main LT panel, complete all as specified and directed by Engr-in-charge. Note: Cost of Spreader, wiring of panel, lugs & visiting charges are deemed to be included in quoted rates.

4

-

-

... More
S&F in replacement of power factor controller suitable for 5 steps APFC panel, complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Supply and fix in repair kiosk pole box made out of Engineering plastic comprising 60Amps, 4 pole strips, mounted on DMC insulator one in No. MCB SP 6 Amps, 10 KA, Size 310 x 210 x 120mm and fixed with MS flat iron clamps to pole complete all as specified and directed by Engr-in-charge.

10

-

-

... More
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed by Engr-in-charge.

15

-

-

... More
M&L for Taking out the unserviceable LT Feeder Panel board including all connection and supply, installation, commissioning and testing of LT Feeder panel, outdoor type, double door, IP 65 Protection, CPRI Approved base frame mounted dust proof and vermin proof with bus bar of 200 Amps current capacity to accommodate 3 Phase, 415Volt with suitable aluminium busbar designed as per relevant IS connected to busbar by aluminium strip of suitable Size, fabricated out of 3.15 mm thick CRCA sheet for outer chamber and 2 mm thick for partition and doors and painting with seven tank process with twin shutter closing, locking arrangements and with 2 nos earthing sprout connectors complete and fixed in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in foundation 40 cm above ground level including provision for fixing of MCCB 160A, 36 KA, 4Pole -1 Nos (Incomer), Digital Amp Meter, Digital Voltmeter, Selector switch, LED Indication Lamps, CT's etc and outgoing TP MCB C curve 63 Amp, 10 KA, 4 pole - 3 nos, pumpset starter - 2 nos including contactor rating 18-30 Amp with 1NO, Add-on block- 1NC, Relay 14-23 Amp, single phase preventor & push button along with indication lamps, complete control wiring for the above accessories complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Supply, installing, testing and commissioning factory made and tested LT Outdoor type, platform mounted, with IP 65 as per IS 13947 protection, fault rating 50 KA/1 Sec, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars of capacity 100 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, and made out of 2.00 mm thick Stainless Steel Sheet SL316 thick & Channel frame work made out of 75 mm, front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm & incl necessary earth work and PCC for foundation including taking down complete all as specified and directed by Engr-in-charge. The scope of work also comprising of the following:- BUS BAR CHAMBER:- (a) 150 Amp TPN, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.

2

-

-

... More
INSTRUMENT CHAMBER:- (i) Volt Meter,96mm,flush type rated 0-500V, Digital type with Volt Meter selector switch- 01 Set. (ii) Amp Meter,96mm,flush type rated 0-60A, Digital type with suitable size C.T's, and Amp Selector switch- 01 Set (iii) RYB Phase indicating light LED type with MCB 6 A SP C Series- 1 Set of three. INCOMING:- (i) MCCB 63 Amps 16 KA , TPN =01 No., OUTGOING:- (i) DOL Starter 7.5 H.P. (Contactor 22A 3 Pole, OLR 9-15A, Push buttons, Indicating Lights)= 02 Nos. , (ii) Motor Protection Automation Phase Sequence Corrector, single phase preventer, digital timer with facility to change over from automatic to manual with contactors upto 7.5 HP motor etc= 01 No Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring minimum 2.5 Sqmm flexible. The panel manufacturer should have following Govt. Approved Certificates: 1. CPRI Certification Degree of Protection IP-65 (should have IEC:60439-1 & IEC:60529 tests) 2. CPRI Certification Short Circuit withstand strenght should be 50kArms for 1.0 Sec with intial peak of 105kA 3. CPRI Certification Rated current for short circuit not less than 6000A with rated insulation voltage 660V 4. ISO 9001 CERTIFIED

-

-

-

... More
M&L for painting of steel tubular pole including cable protection pipe and all iron parts of 9/11 mtr long pole complete with two coats of aluminium paint after cleaning all rust and dust and preparing surface with wire brush and including strip of white and red colour of synthetic enamel paint complete all as specified and directed by Engr-in-charge. Note: Rate quoted deemed to be inclusive of all T&P like ladder required at site & has to be arranged by contractor.

10

-

-

... More
Supply and fixing in replacement Aluminium tube terminal of capacity 25 sqmm complete all as specified and directed by Engr-in-charge.

30

-

-

... More
Supply and fixing in replacement Aluminium tube terminal of capacity 35 sqmm complete all as specified and directed by Engr-in-charge.

30

-

-

... More
Supply and fixing in replacement Aluminium tube terminal of capacity 50 sqmm complete all as specified and directed by Engr-in-charge.

30

-

-

... More
Supply and fixing in replacement Aluminium tube terminal of capacity 70 sqmm complete all as specified and directed by Engr-in-charge.

30

-

-

... More
Supply and fixing in replacement Aluminium tube terminal of capacity 95 sqmm complete all as specified and directed by Engr-in-charge.

30

-

-

... More
Supply and fixing in replacement of Aluminium Thimble of size 25mm complete all as specified and directed by Engr-in-charge.

40

-

-

... More
Supply and fixing in replacement of Aluminium Thimble of size 35mm complete all as specified and directed by Engr-in-charge.

40

-

-

... More
Supply and fixing in replacement of Aluminium Thimble of size 50mm complete all as specified and directed by Engr-in-charge.

40

-

-

... More
Supply and fixing in replacement of Aluminium Thimble of size 70mm complete all as specified and directed by Engr-in-charge.

40

-

-

... More
Supply and fixing in replacement of Aluminium Thimble of size 95mm complete all as specified and directed by Engr-in-charge.

40

-

-

... More
S&F in replacement of LED retrofit tubelight, 4 ft long of 20 watt, complete all as specified and directed by Engr-in-charge.

50

-

-

... More
S&F in replacement of LED retrofit tubelight, 2ft long of 10 watt, complete all as specified and directed by Engr-in-charge.

10

-

-

... More
S&F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor able of suitable size, complete all as specified and directed by Engr-in-charge.

10

-

-

... More
S&F in replacement of Street light bracket of size 40mm dia light grade GI pipe, including nut, bolts, Fastner etc, complete all as specified and directed by Engr-in-charge.

10

-

-

... More
Supply and fixing manual change over switch AC 21 (side handle) in sheet enclosure, 200 Amps, 415 Volts AC, 50 Hz, confirming to IEC 947-3, EN-60947-3, AC-23A, 4 pole complete all as specified and directed by Engr-in-charge.

1

-

-

... More
S&F in replacement of DIN Type Fuse Links Type HN of 160Amp, Suitable for Type FN 200 / FNX 200 S-D-F & for HB 250 Fuse base complete all as specified and directed by Engr-in-charge.

6

-

-

... More
S&F in replacement of DIN Type Fuse Links Type HN of 200Amp, Suitable for Type FN 200 / FNX 200 S-D-F & for HB 250 Fuse base complete all as specified and directed by Engr-in-charge.

6

-

-

... More
S&F in replacement of SPN MCB, 32Amp , B Curve, 10 KA , complete all as specified and directed by Engr-in-charge.

6

-

-

... More
S&F in replacement of SP MCB, 6-32Amp , B Curve, 10 KA , complete all as specified and directed by Engr-in-charge.

10

-

-

... More
M&L for dismantling of broken Valve pit chamber brick work, cleaning old bricks and reconstructing wall (same height/ raising height above ground level) of wall pit chamber with old/new bricks upto 1200mmx 1200x 900mm size valve pit chamber including plastering & two coat white wash all surfaces both internal & external and refixing MS cover by welding complete all as specified and directed by Engr-in-charge.

40

-

-

... More
M&L for scrapping broken plasters from valve pit chamber, & preparing surface for Rendering 10mm thick on fair faces of brick work or concrete surfaces with cement plaster 1:4, complete all as specified and directed by Engr-in-charge.

60

-

-

... More
M&L for Two coat of white wash valve pit chamber in white colour and MS cover of pit chamber with black paint or complete all as specified and directed by Engr-in-charge.

60

-

-

... More
M&L for taking down corroded, broken & u/s MS valve pit cover of any thickness upto 1200mmx 1200x 900mm size valve pit chamber and replacing MS sheet not less than 4mm thick and angle iron frame not less than 40mmx40mmx5mm by deploying skilled welder & black smith including painting with one coat of primer & two coat of paint in black colour, complete all as specified and directed by Engr-in-charge.

60

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.