Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Dec 2024
Closing Date31 Dec 2024
Tender Amount₹ 10,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for repair to suction & discharge valve of compressor 3x25 TR of capacity by means of replacing the teflon washer sheet, suction & discharge valve ring, spring, 'O' rings, gaskets etc complete and testing for proper holding of valve, leak testing etc complete all as specified and as directed by the Engineer-in-Charge. NOTE: The rate inclusive of suction & discharge valve which is considered as one job.

2

-

-

... More
S & F in Replacement of panel air filters, dry type, washable, rated air flow capacity 1600 CFM 99.9%, down to particle 20 micron of Suitable sizes or nearest for AHU of central AC plant complete all as specified and directed by the Engineer-in-Charge.

10

-

-

... More
Supply and fix in replacement of liquid line Y strainer for AHU 20000 CFM and condenser pipe line including welding, leak testing and leak arrest complete all as specified and directed by the Engineer-in-Charge..

1

-

-

... More
M & L for Preparation of old painted surfaces and applying two coats of synthetic enamelled paint to external surfaces of chiller units - 03 No's, including foundation of compressor & motor units- 03 No's, suction & discharge refrigerant pipe line, condenser water pump with motor & foundation - 02 No's, chiller water pump with motor & foundation-02 Nos water pipe line, AHU unit and motor/blower- 01 No, cooling tower with motor -01 No condenser - 03 No's sets of any capacity of central AC plant at 3x25 TR AC plant complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
Supply and fix in replacement of unserviceable suction pressure gauge minus 30 to 150 PSI of dia 4" complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable oil pressure gauge 0 to 150 PSI of dia 4" complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable 3 pole power contactor ML-1 complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable 3 pole power contactor ML-1.5 complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable 3 pole power contactor ML-2 complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable 3 pole power contactor ML-3 complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable timer unit ET-100, 0-60 sec complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable Single phase preventor (Auto reset, 40 Volts unbalanced) VSP-2 complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable thermal overload relay 6-10 Amps as per existing make complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
All as per item No 16.00 here in before but 10-16 Amps complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
All as per item No 16.00 here in before but 20-32 Amps complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable overload relay 25 Amps complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
All as per item No 19.00 here in before but 25-40 Amps complete all as specified and directed by the Engineer-in-Charge.

3

-

-

... More
Supply and fix in replacement of unserviceable MCCB 200 amps 4 pole 36 KA 415 volts 50 Hz with adjustable thermal and fixed magnetic setting complete (Ics=100% Icu) all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
Supply and fix in replacement of unserviceable MCCB 100 amps 4 pole 25 KA 415 volts 50 Hz with adjustable thermal and fixed magnetic setting including taking out old unserviceable MCCB from panel complete (Ics=100% Icu) all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable MCB C curve TP 16-32A complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable MCB C curve TPN 63A complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable MCB C curve TP 63A complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable MCB C curve SP 6-32A complete all as specified and directed by the Engineer-in-Charge.

3

-

-

... More
Supply and lay (in trenches/duct/fixing to pole/wall or in such similar position ) LT UG cable XLPE insulated armoured and PVC sheathed LT 1100 volts grade with aluminium conductor in replacement of existing U/s UG cable including taking down old unserviceable UG cable from existing position of following stranded of sizes :-

-

-

-

... More
10 Sqmm 4 core

50

-

-

... More
25 Sqmm 4 core

40

-

-

... More
35 Sqmm 3.5 core

40

-

-

... More
50 Sqmm 3.5 core

30

-

-

... More
Supply and installation in replacement of phase frequency corrector of capacity 200 HP of 3 phase corrector for 3 phase central AC plant other 3 phase items , electrically controlled with interlocking system duly pre wired with multi stranded copper wire of durable rating , powder coated metallic housing with hanged door and indicator for each phase. current rate 40A- 300 A, Voltage rating 440V complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
Supply and fix in replacement of unserviceable filter drier connected with compressor with existing model complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable water pressure gauge 0-150 PSI 4" dia dial type complete all as specified and directed by the Engineer-in-Charge.

3

-

-

... More
Supply and fix in replacement of unserviceable Thermometer industrial type complete all as specified and directed by the Engineer-in-Charge.

3

-

-

... More
Supply and fix in replacement of unserviceable contactor MNX-12 2 pole with thermal magnetic release and 1 NO complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable add on contacts MNX A2 with 1 NO+NC complete all as specified and directed by the Engineer-in-Charge.

3

-

-

... More
Supply and fix in replacement of unserviceable add on contacts MNX A1 with NO+NC complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
M&L in repair for insulation to chilled water piping with 12 mm thick rubber nitrile with Aluminium foil of density 30 Kg/Cum for 65 mm Chilled water pipe complete with rubber based adhesive Pidlite SR 998/equivalent and thermal conductivity not exceeding 0.0035 W/Mk at an average temp of 40 Degree C complete all as specified and directed by the Engineer-in-Charge.

20

-

-

... More
M&L in repair for insulation to following chilled water piping of central AC plant of following sizes with 19 mm (for all pipes) and 13 mm (for drain pipes) thick closed cell chemically cross linked fire retardant polyethylene foam insulation of density 30 Kg/Cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C, covered with aluminium faced foil complete with application with rubber based adhesive pidilite SR 998 and 50 mm X 3 mm thick self adhesive tape on both longitudinal & transverse joints simultaneously complete all as specified and directed by the Engineer-in-Charge.

-

-

-

... More
80 mm dia chilled water pipe including valves, strainers etc.

30

-

-

... More
65 mm dia chilled water pipe including valves, strainers etc.

20

-

-

... More
50 mm dia drain pipe.

5

-

-

... More
M&L in repair for insulation to HDPE expansion tank of size 1000 Ltr of central AC Plant with suitable FR-XLPE/XPE 19 mm thick of minimum bulk density 28±4 Kg/Cum covered with vapour barrier and finished with 0.5 mm thick aluminium cladding and application with rubber based adhesive pidilite SR 998 and 50 mm X 3 mm thick self adhesive tape on joints complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
M&L for repair to 3 phase monoblock water pump set of capacity 7.5 HP including rewinding in replacement of bearings, seal, cleaning of parts and carry out necessary inspection for wornout parts, replacement of old unserviceable worn out parts,also replacement pump motor casing and refixing the unit to its existing location after completion of overhauling/repair complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
M&L for taking out unserviceable squirrel case motor and rewinding squirrel case motor of mono block pump set model KDS-527 of capacity 5 HP 3 phase with super enamelled copper winding wire and replacement of bearing and minor spare parts like as keys, bushes etc and testing after rewinding and refixing to its existing location after rewinding complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
M&L for painting LT Panel installed for central AC plants at WAC Ops room as per existing colour code with one coat of synthetic enamel paint with the help of spray gun after cleaning and preparation of surfaces complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
M&L for painting Servo Voltage stablizer of capacity 200 KVA as per existing colour code with one coat of synthetic enamel paint with the help of spray gun after cleaning and preparation of surfaces including writing SM/MES No with white letters on black back ground complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
S&F in replacement scroll compressor of cap 12.5 TR with washers, bolts and nuts three phase 415 V 50 Hz suitable for central AC plant including brazing leak test of the system with compressed nitrogen and testing the unit for satisfactory functioning complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Taking out unserviceable AHU motor and rewinding AHU motor 12.5 HP 3 phase 415 V with copper winding wire including insulation thimbles greasing & replacement of minor spare parts such as keys, bushes etc and testing after rewinding and refixing to its existing location after rewinding all as specified and directed by Engr-in-Charge.

1

-

-

... More
Taking out unserviceable CT motor 5 HP suitable for cooling tower with capacity 60 TR and rewinding with super enamelled copper winding wire including replacement of bearings and testing after rewinding and refixing to its existing location complete all as specified and irected by the Engineer-in-Charge.

1

-

-

... More
Supply only refrigeration gas R-407C in manufacturer sealed cylinder including pressure testing the complete plant by dry nitrogen gas by separating high side and low side, rectifying the leakage by gas welding brazing pressure testing vaccuming the system and re-charging the system with gas, testing and commissioning complete all as specified and directed by the Engineer-in-Charge. NOTE:- (i) Gas to be supplied in manufacturer sealed container. (ii) Empty containers will be returned to contractor .

110

-

-

... More
Supply & filling in replacement of transformer oil in servo stabilizer of capacity 200 KVA complete all as specified and directed by the Engineer-in-Charge.

90

-

-

... More
Supply, installation, testing and commissioning in replacement electric strip heater in replacement to unserviceable one for winter heating and monsoon reheating with finned type heaters of cap 3 KW including end terminations complete all as specified and directed by the Engineer-in-Charge.

15

-

-

... More
S&F in replacement PVC fills as per existing model and size heavy duty for forced draught type cooling tower of central AC plant complete all as specified and directed by the Engineer-in-Charge.

150

-

-

... More
S&F in replacement of condenser water and chilled water pipes of MS heavy grade of following sizes/dia with all fittings complete laid in trenches/on wall/on ceiling/roof etc including necessary suitable size of MS clamps/saddling on walls etc complete all as specified and directed by the Engineer-in-Charge.

-

-

-

... More
100 mm dia.

40

-

-

... More
80 mm dia.

30

-

-

... More
65 mm dia.

20

-

-

... More
S&F in replacement GI tubing medium grade of following sizes/dia with all fittings complete laid in trenches/on wall/on ceiling/roof etc including necessary suitable size of MS clamps/saddling on walls etc complete all as specified and directed by the Engineer-in-Charge.

-

-

-

... More
GI Tubing 15 mm dia.

40

-

-

... More
GI Tubing 20 mm dia.

30

-

-

... More
GI Tubing 25 mm dia.

20

-

-

... More
GI Tubing 32 mm dia.

15

-

-

... More
Supply and fix in replacement of discharge safety valve with checking of leak testing complete all as specified and directed by Engr-In-Charge

2

-

-

... More
S&F in replacement of 6 Sqmm PVC insulated and FR sheathed copper Control Cable , 3 core 1100 V conforming IS 694 for AHU motor including connection from panel to Motor complete all as specified and directed by Engr-in-Charge.

30

-

-

... More
S & F in replacement of Oil HP cut out Type MP - 5 suitable for R 407C gas complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
S & F in replacement of GAS LP/HP combination cut out MP - 15 Suitable for R 407C gas complete with flare nut complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
S & F in replacement of solenoid pilot control valve type 10 with two / three coil assembly of same model complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of Gate valve suitable for 50 mm dia MS pipe complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of butterfly valve suitable for 80 mm dia MS pipe complete all as specified and directed by the Engineer-in-Charge.

3

-

-

... More
Supply and fix in replacement of butterfly valve suitable for 65 mm dia MS pipe complete all as specified and directed by the Engineer-in-Charge.

3

-

-

... More
S& F in replacement of earth leakage relay suitable for 3x25TR compressor motor starter complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
Supply & fix replacement of ammeter with ratio of 100/5 Amps complete all as specified and directed by the Engineer-in-Charge.

3

-

-

... More
Supply & fix replacement of voltmeter 0-500 V AC supply 50 Hz complete all as specified and directed by the Engineer-in-Charge.

4

-

-

... More
Supply and fix in replacement of unserviceable V belt for AHU for central AC plant of capacity 3x25 TR complete all as specified and directed by the Engineer-in-Charge. Make: Fenner model No. B 76 or equivalent in Asian or existing as per site.

3

-

-

... More
Supply and fixing in repair Electrical wiring of panel with suitable 1.5 Sq.mm/2.5 Sqmm/4 Sqmm (nominal area) PVC unsheathed multi stranded copper conductor PVC insulated 1100 volt FRLS grade single core cable, testing and commisioning of complete power system including taking down and refixing of serviceable connector,thimble, timer,overload relay,earth leakage relay, MCCB, servicing of starter etc satisfactory operation of the AC plant of capacity 3x25TR complete all as specified and directed by the Engineer-in-Charge. Note:- Additional spare parts measured and paid separately

2

-

-

... More
Supply and fix in replacement of Expansion Valve capacity of 11 TR including welding/brazing and checking of leaking and leak arrest complete all as specified and directed by the Engineer-in-Charge.

4

-

-

... More
M&L for repair to unserviceable PCB board suitable for central AC plant of compressor 2x12.5 TR capacity by means of re-programming of PCB as per existing software complete and testing for proper working of PCB complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of sprinkler system of cooling tower is suitable for 60 TR, anti corrosive material,including fan and outlet pipe system complete all as specified and directed by the Engineer-in-Charge.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.