If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 89,900Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_686198_1Tender No
GE/DS-96/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR/REPLACEMENT OF DBs, SUBMAIN WIRING, REWIRING, SUMMER AND COOLING APPLIANCES AT KHANPUR ARMY CAMP, MANESAR ARMY CAMP, INDU BINOLA AND DUNDAHERA MIL STN UNDER AGE E/M OF GE (SOUTH) DELHI CANTT-10
BOQ Items
... More
S&F in repair switch piano flush type 6 Amps SP 2-way complete all as specified and as directed.
20
-
-
... More
S&F in repair bell push, flush type 6 Amps complete all as specified and as directed.
50
-
-
... More
S&F in repair socket outlet 6 Amps flush mounted piano type 5 pin multi purpose complete all as specified and as directed.
550
-
-
... More
S&F in repair switch piano type 16 Amps SP one way complete all as specified and as directed.
450
-
-
... More
S&F in repair socket outlet 2 in 1 (multipurpose) 6 pin 6 and 16 Amps flush mounted type complete all as specified and as directed.
450
-
-
... More
S&F in repair lamp holder bakelite insulated body with back plate suitable for batten fitting complete all as specified and as directed.
400
-
-
... More
S&F in repair bell Ding dong type 230 volts single phase complete all as specified and as directed.
60
-
-
... More
S&F in repair ceiling rose surface Bakelite 65x25 mm two to three terminals complete all as specified and as directed.
150
-
-
... More
S&F in repair fan regulator electronic, stepped type, Switch type, suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed.
400
-
-
... More
S&F in repair fan condenser of capacity 2.5 Mfd complete all as specified and as directed.
450
-
-
... More
S&F in repair fan condenser of capacity 3.15 Mfd complete all as specified and as directed.
50
-
-
... More
S&F in repair LED Glass Bulb 9 Watt B-22 Cap, AC 230V, 50 Hz, suitable for Batten Holder/Bulk head/wall light fittings complete all as specified and as directed.
600
-
-
... More
S&F in repair Decorative wall light made up of high grade engineering plastic material suitable for 9 W LED lamp B22 base complete all as specified and as directed.
80
-
-
... More
S&F in repair LED Bulk head 10 watt integrated type complete with 3 core flexible connecting wires complete all as specified and as directed.
80
-
-
... More
S&F in repair LED Batten T-5 fitting 20 watt LED White, indoor decorative aluminum extruded integrated type environmental friendly complete all as specified and as directed.
1000
-
-
... More
S&F in repair LED Integrated Batten T5 10 watt - 2FT long White, indoor decorative polycarbonate extruded integrated type environmental friendly complete all as specified and as directed.
150
-
-
... More
S&F in repair LED Building security light fitting 45W energy saving and environmental friendly made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening with seperate driver compartment and IP66 protection complete all as specified and as directed.
60
-
-
... More
S&F in repair Circuler Hylam/PVC Sheet upto 10 cm dia of 3 mm thick (for using as Junction box Cover) including screws and cup washer complete all as specified and as directed
25
-
-
... More
S&F in repair PVC casing caping of size 25mm with suitable size of nails for fixing PVC casing caping, in repairs of batten/surface wiring complete all as specified and as directed.
25
-
-
... More
M&L for submain wiring with two runs of 4 Sqmm size for main cable and one run of 4 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked , drawn through existing Steel/PVC concealed conduit of size 25mm dia with all fittings accessories complete all as specified and as directed. Note :- New conduit of suitable size with connected fittings will be laid if there is a burnt/blockage/damage to the existing conduit including bends/elbows/tees/ Junction boxes including making good to disturbed surface finished with the adjoining surface of disturbed area and the rates are deemed to be inclusive of quoted rates.
200
-
-
... More
M&L for submain wiring with two runs of 6 Sqmm size for main cable and one run of 6 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked , drawn through existing Steel/PVC concealed conduit of size 25mm dia with all fittings etc complete accessories all as specified and as directed. Note :- New conduit of suitable size with connected fittings will be laid if there is a burnt/blockage/damage to the existing conduit including bends/elbows/tees/ Junction boxes including making good to disturbed surface finished with the adjoining surface of disturbed area and the rates are deemed to be inclusive of quoted rates.
800
-
-
... More
M&L for submain wiring with two runs of 10 Sqmm size for main cable and one run of 10 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked, drawn through existing Steel/PVC concealed conduit of size 25mm dia with all fittings accessories all as specified and as directed. Note :- New conduit of suitable size with connected fittings will be laid if there is a burnt/blockage/damage to the existing conduit including bends/elbows/tees/ Junction boxes including making good to disturbed surface finished with the adjoining surface of disturbed area and the rates are deemed to be inclusive of quoted rates.
150
-
-
... More
Taking down of ceiling fan/ exhaust fan/ wall mounted fan including dismantling of blades, transportation to work shop and carrying out rewinding, transportation to site, reinstallation and testing etc complete all as specified and as directed. Note:- Rewinding will be measured and paid under respective item of BoQ.
300
-
-
... More
M&L for Rewinding of ceiling fan 1200/1400 mm sweep by dismantling of fan motor, cutting and removing of burnt windings, cleaning, winding with supper enamelled copper wire of superior quality of same gauge, same Nos of turns, provn of insulation paper, applying of varnish, drying of varnish and assembling of fan including replacement of gun metal bush, shaft and ball bearing etc where ever required complete all as specified and as directed.
Note: Ball bearing and shaft will be measured and paid separately under respective item of BOQ.
150
-
-
... More
All as per item 26 above, but exhaust fan/wall mounted fan upto 450 mm sweep complete.
150
-
-
... More
S&F in replacement Gun metal bush for fans of any size/fan etc complete all as specified and as directed.
100
-
-
... More
S&F in replacement Ball bearing of suitable size & model for ceiling/Exhaust fan (as per sample) complete all as specified and as directed.
150
-
-
... More
S&F in replacement exhaust fan iron blades for size 225/300/450 mm sweep as per sample complete all as specified and as directed.
80
-
-
... More
Supply only motor of exhaust/fresh air fans of 225/300 mm sweep, heavy duty, duly painted with one coat of synthetic enamel paint of suitable colour complete all as specified and as directed.
20
-
-
... More
Supply only motor of exhaust/fresh air fans of 450 mm sweep, heavy duty, duly painted with one coat of paint of suitable colour complete all as specified and as directed.
30
-
-
... More
Supply only metal frame of exhaust/fresh air fans of 225/300/450 mm sweep, heavy duty duly painted with one coat of synthetic enamel paint of suitable colour complete all as specified and as directed.
50
-
-
... More
S&F in replacement Exhaust fan Louvers 225/300/450 mm sweep, MS, including taking out old louvers complete all as specified and as directed.
50
-
-
... More
Supply only in replacement ceiling fan holder hook with rubber real suitable for size 1200/1400 mm sweep ceiling fan as per sample complete all as specified and as directed.
140
-
-
... More
S&F in repair PVC canopy for ceiling fan of size 1200/1400 mm sweep as per sample complete all as specified and as directed .
90
-
-
... More
S&F in repair plug top 20 Amps complete all as specified and as directed.
10
-
-
... More
S&F in repair single pole and neutral metal clad sheet steel enclosures with 2 pin and earth plug and socket complete with one no MCB SP upto 20 Amps as per site requirement of existing type complete all as specified and as directed.
12
-
-
... More
S&F in replacement MCB DB SPN 4 Way double door type, (IP 43 Protection) flush mounting complete all as specified and as directed.
12
-
-
... More
S&F in replacement MCB DB SPN 8 Way double door type,(IP 43 Protection) flush mounting complete all as specified and as directed.
20
-
-
... More
S&F in replacement MCCB 3 Pole 415V, Adjustable type, 100 amps with breaking capacity 16 KA complete all as specified and as directed.
5
-
-
... More
S&F in replacement MCCB 3 pole, 415V, Adjustable type,125 amps with breaking capacity 16 KA complete all as specified and as directed.
5
-
-
... More
S&F in replacement MCCB 3 pole 250 Amps 36 KA 415 Volts with breaking capacity 36 KA, complete all as specified and as directed.
1
-
-
... More
S&F in repair Recessed mounting 36 Watt 2'x2' flat LED panel fitting luminaire to enhance the delight of occupants with comfortable experience through its classic design and glare & Flicker free illumination. White powder coated CRCA housing with seamless front frame with flat non-yellowish diffuser to fix in existing POP including cutting/grouting of existing POP and get electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and as directed.
40
-
-
... More
S&F in repair MCB SP 06 to 32 Amps 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and as directed.
350
-
-
... More
S&F in repair MCB SPN 40 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and as directed.
75
-
-
... More
S&F in repair MCB SPN 63 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and as directed.
60
-
-
... More
S&F in repair MCB TPN/ Isolator 4P from 63 Amps 415 volts, 'C' Series 10 KA as per site requirement complete all as specified and as directed.
35
-
-
... More
S&F in repair MCB TP 3 Pole from 40 Amps 415 volts, 'C' Series 10 KA as per site requirement complete all as specified and as directed.
12
-
-
... More
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and as directed.
970
-
-
... More
M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through existing concealed PVC/ MS conduit and including replacement of unserviceable pressed steel terminal boxes of required size with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing) and making good to disturbed surface of walls including necessary touch up with adjoining surface of disturbed area i.e with OBD/colour work/white wash as existing finishes complete all as specified and as directed for the followings :-
Note :- In existing conduit wiring, new conduit will be added where there is a burnt/blockage/damage to the existing conduit including bends/elbows/tees/junction boxes etc.
-
-
-
... More
(a) One light / fan/bell point controlled by one switch SP, one way, 230 volts.
450
-
-
... More
(b) One 3 pin socket outlet 5/6 Amps on same board.
250
-
-
... More
(c) One socket outlet 5/6 Amps on independent board.
150
-
-
... More
(d) One power socket 15/16 Amp but with cable 2.5 Sqmm for phase & neutral and for earth 2.5 sqmm.
120
-
-
... More
S&F in replacement distribution board vertical triple pole and neutral 4 way, double door for fixing MCCB upto 125 Amps as incommer and MCBs as out goings with metal door with IP 43 Protection and connecting complete all as specified and as directed.
8
-
-
... More
S&F in repair MS fastner bolt 8mm dia and 100mm (Min.) for fixing Exhaust fan/Bldg security light etc with nuts and washer etc complete all as specified and as directed.
40
-
-
... More
Taking down geyser 25/50 ltrs capacity of any make, opening up complete for inspection descalling by chemical treatment of internal tank , themrostate pipe, base plate assembly carrying out minor repairs including replacement of gaskets testing and refixing in position including making electrical and water connection complete all as specified and as directed.
52
-
-
... More
S&F in repair heating element 1.5 KW for any make of geyser of 25 litres capacity as per sample complete all as specified and as directed.
40
-
-
... More
S&F in repair heating element 2 KW for any make of geyser of 50 litres capacity as per sample complete all as specified and as directed.
10
-
-
... More
S&F in repair thermostat for 25/50 ltrs capacity geysers complete all as specified and as directed.
35
-
-
... More
S&F in repair indicating lamp, round / flat type as required for geyser 25/ 50 litres capacity as per sample complete all as specified and as directed.
50
-
-
... More
S&F in repair safety valve ISI marked for geyser 25/50 litres capacity as per sample complete all as specified and as directed.
35
-
-
... More
S&F in repair safety plug for geyser 25/50 litres capacity as per sample complete all as specified and as directed.
30
-
-
... More
S&F in repair PVC connection with brass nipple 15 mm x 450 mm long for geyser 25/50 ltrs capacity as per sample complete all as specified and as directed.
50
-
-
... More
S&F in repair base plate geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket for any make of geyser of 25 litres cap as per sample complete all as specified and as directed.
18
-
-
... More
S&F in repair base plate geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket for any make of geyser of 50 litres cap as per sample complete all as specified and as directed.
12
-
-
... More
S&F in repair 25 Ltr inner stainless steel tank suitable for 25 Ltr storage water heater complete all as specified and as directed.
25
-
-
... More
S&F in repair 50 Ltr inner stainless steel tank suitable for 50 Ltr storage water heater complete all as specified and as directed.
5
-
-
... More
M&L for welding /brazing the inner shell made out of stainless steel /copper sheet for geyser of 25/50 ltrs capacity of any make and make the shell water tight including testing etc complete all as specified and as directed.
Note:-Taking down, de-scaling, replacement of rubber gasket and any minor repair involved will be mesured and paid seperatly.
22
-
-
... More
S&F in repair Rubber gasket for water heater storage type of any capacity fixed and suitable as per the existing, complete all as specified and as directed.
45
-
-
... More
M&L for Top & Bottom cover body suitable for 25 Ltrs storage water storage heater made of MS sheet as per site requirement complete all as specified and as directed.
30
-
-
... More
M&L for Top & Bottom cover body suitable for 50 Ltrs storage water storage heater made of MS sheet as per site requirement complete all as specified and as directed.
5
-
-
... More
Comprehensive maintenance of desert cooler of any type and make, fixed at different locations at Dundahera Mil Stn and Manesar Army Camp including taking down, cleaning all dirt, dust, oiling of motor and pump, checking of parts, including replacement of nuts, bolts, screws etc and preparation of desert cooler body and tank by scrubbing the old paint and spray painting with two coats of synthetic enamel paint complete all as specified and as directed. Note : Supply and replacement of parts shall be measured and paid separately under respective item of BOQ.
79
-
-
... More
S&F in repair 18 inch mounting frame including 3 sets of side Panels made with 2mm thick MS sheet as per existing size/Model and as per sample for desert cooler complete all as specified and as directed.
20
-
-
... More
S&F in repair blade of 18 inch sweep suitable for desert cooler complete all as specified and as directed.
20
-
-
... More
S&F in repair operating kit for 18 inch desert cooler complete all as specified and as directed.
20
-
-
... More
S&F in repair fan mounting bracket set as required for desert cooler complete all as specified and as directed.
20
-
-
... More
S&F in repair water lifting pump,single phase suitable for desert coolers complete all as specified and as directed.
20
-
-
... More
S&F in repair cooler fan motor 1/7 HP or any HP as per site requirement 230 volt, 50Hz cycles AC complete all as specified and as directed.
20
-
-
... More
S&F in repair capacitor, 4 mfd rating complete all as specified and as directed.
20
-
-
... More
S&F in repair wood wool pad (set of 3) suitable for 18 inch sweep desert cooler of good quality in all respect complete all as specified and as directed.
20
-
-
... More
M&L for refilling of gas in 1.5 Ton AC including necessary arrangement for gas filling.R-22 complete all as specified and as directed.
2.8
-
-
... More
M&L for refilling of gas in 320 ltr capacity Deep Frzeer including necessary arrangement for gas filling. R-134A complete all as specified and as directed.
3.2
-
-
... More
S&F in repair compressor for deep freezer of capacity 320 ltr complete all as specified and as directed.
1
-
-
... More
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE, Five Star rated with Brush Less Direct Current (BLDC) motor including taking down of old unsv BER declared conventional ceiling fans and depositing old fans safely to MES storeyard complete all as specified and as directed.
225
-
-
... More
Notes :- (i) The contract sum shall be after deducting the amount of Credit shown in Sch of Credit of this Tender.
(ii) If any item of same description in nature is found to be entered as "double in BOQ" and the bidder quotes different rates against same item, then the rate quoted on lower side shall be applicable and higher rate will not be allowed to be paid in any circumstances. No claims on this account shall be entertained on a later date.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%