Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Dec 2024
Closing Date11 Jan 2025
Tender Amount₹ 67,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Note for item No 2:- 1. Comprehensive maintenance included main equipments of plant viz chiller unit evaporator unit, including control panel station and checking the functioning of allied equipments such as Air Handling units/Pumps/Cooling towers/Controls and all other eqpts. Descaling of condenser / evaporator unit by chemical cleaning as per OEM instructions. 2. Replacing of defective/worn out parts with new or repaired parts for compressor/thermostat/cutouts based. 3. Descaling of condenser/chemical cleaning as per OEM recommendation. 4. Replenishing/topup refrigerant gas and compressor oil as per OEM recommendation. 5. Checking of Microprocessor control panel, control boards, transducers of packaged chillers/condensing unit for their correctness and replacing other allied parts.

-

-

-

... More
Special note for item Ser No. 1 & 2: 1. The cost of spares and labour for any minor or major repairs of chiller plants as and when required (as recommended by the OEMs (S) during inspection/analysis report) shall be provided by the contractor at no extra cost and rate for the same are deemed to be included in the unit rates of item as above. 2. Charging of refrigerant gas and and compressor oil in chiller plant shall be arranged by the contractor as per terms and condition of OEM (S) as required. 3. The contractor is liable to maintain 21 degree centigrade temperature (plus/minus 2 degree C) and 50% relative humidity (plus/minus 5%) in the rooms. 4. Contractor is required to enter in to "Level-3" MOU with respective OEM . The contractor shall submit Coppy of MoU to Accepting officer for his approval berore commencement of work. The service Engineer from original OEM (s) will visit the A/C plant minimum one time in a month and will submit inspection report to the Engineer-in-charge. Necessary repair action will be taken immediately if/as required and periodical maintenance of plant will be carried out by contactor as per technical instructions OEM. 5. In case of any minor fault in the machineries of Central AC plant due to which the plant is put off more than 12 hours the following penalties shall be recovered from the contractor.

-

-

-

... More
6. Rs. 10000/- per day will be recovered from the contractor for non rectification of defect/replacement of any unserviceable spares after 12 hours from lodging of complaint telephonically or verbally. 7. Thereafter Rs. 10000/- will be added every day till rectification of fault/replacement of unserviceable spares as directed. 8. In case of any major fault in the machineries of Central AC plant due to which the plant is put off more than 48 hours the following penalties shall be recovered from the contractor :- 9. Rs. 10000/-per day will be recovered from the contractor for non rectification of defect/replacement of any unserviceable spares after 48 hours from lodging of complaint telephonically or verbally. 10. Thereafter Rs. 10000/- will be added every day till rectification of fault/replacement of unserviceable spares as directed.

-

-

-

... More
Supply and lay in replacement of MS pipes heavy grade with all fittings laid in trench, floors or fixed to walls and ceilings etc of sizes as shown following size:-

-

-

-

... More
40 mm dia 

60

-

-

... More
65 mm dia 

140

-

-

... More
100 mm dia

60

-

-

... More
125 mm dia

75

-

-

... More
150 mm dia

20

-

-

... More
300 mm size

30

-

-

... More
Supply and fixing in replacement of Butterfly Valve manually operated complete all as specified and directed of following sizes:-

-

-

-

... More
300 mm dia

2

-

-

... More
150mm dia

8

-

-

... More
125mm dia

10

-

-

... More
100 mm dia

3

-

-

... More
80 mm dia 

3

-

-

... More
65 mm dia

8

-

-

... More
Supplying and fixing in replacement of mild steel strainer (ISI marked) (pot strainer for Suction) of 300 mm dia top flange openable type complete all as specified and directed

1

-

-

... More
Supply and fixing in replacement of balancing Valve 150 mm dia (ISI marked) manually operated complete all as specified and directed.

4

-

-

... More
Supply and fixing in replacement of balancing Valve 125 mm dia (ISI marked) manually operated complete all as specified and directed

4

-

-

... More
Supplying and fixing in replacement of Y strainer 150 mm dia (ISI marked) complete all as specified and directed.

2

-

-

... More
Supplying and fixing in replacement of Y strainer 125 mm dia (ISI marked) complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement of NRV Valve 150 mm dia (ISI marked) manually operated complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement of NRV Valve 125 mm dia (ISI marked) manually operated complete all as specified and directed

2

-

-

... More
Material and labour for insulation of M.S Pipe 125 mm dia with PUF slab insulation 40 mm thick of density 36 Kg/Cum with and including applying bituminous compound and GI cladding with 26 gauge Gl sheet including taking down unserviceable insulation complete.

75

-

-

... More
Material and labour for insulation of M.S Pipe 100 mm dia with PUF slab insulation 40 mm thick of density 36 Kg/Cum with and including applying bituminous compound and GI cladding with 26 gauge Gl sheet including taking down unserviceable insulation complete.

60

-

-

... More
Material and labour for insulation of M.S Pipe up to 80 mm dia with PUF slab insulation 40 mm thick of density 36 Kg/Cum with and including applying bituminous compound and Gl cladding with 26 gauge Gl sheet including taking down unserviceable insulation complete.

140

-

-

... More
M&L for taking down existing diffuser/grill from duct and cleaning, washing with detergent mixed with hot water to remove all dirt, dust, foreign materials, germs etc and painting with one coat of super enameled synthetic paint and refixing the same back to its original position complete as directed

50

-

-

... More
Material and labour for robotic cleaning of existing duct through high power vacuum cleaner, high pressure compressor air using special nozzle, brush, scrubbers, 'HEPA AIR" equipment & technology i.e fixing/showing for inspection of duct before and after cleaning of duct complete including removing and refixing of existing grill/diffuser for cleaning all as specified and directed.

1000

-

-

... More
Supply and fixing in replacement of louver faced ceiling diffusers surfaces/recessed mounted white finish with aluminum white finish with aluminum construction with neck size 6 and panel size 24 x 24 inches with damper control handle all as directed. Make - MRI or Equivalent.

10

-

-

... More
Supplying and fixing in replacement industrial pressure gauge 100mm dia dial type complete all as specified and directed

10

-

-

... More
Supplying and fixing in replacement of balancing valve 80mm dia (ISI marked) suitable for hot water pump valve package for hot water pump all as specified and directed

2

-

-

... More
M&L for servicing and cleaning of AHUs capacity up to 13000 CFM by taking out the filters (any type ) from AHUs for cleaning grills, coil/mesh with suitable chemical and jet of water pressure cleaning of blower assembly, water tubes with air pressure to sweep up all the dust particles and ensure throughout flow of air over the cooling coil complete all as specified and directed for any capacity of AHU and refixing the air filter after cleaning complete all as specified and as directed.

20

-

-

... More
M&L for repairing/ servicing AHU Fan Motor of following capacity, opening the motor, cutting & removing old and burnt winding wire. rewinding the motor with new super enameled copper winding of size & description to match with existing including insulating materials, varnishing, drying, replacement of both driven end & non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed. Note:- fabrication work for taking down of motor from main AHU shaft and after repair refixing of motor in same position is part of the scope of work and cost of the same is deemed to be included in the quoted rate.

-

-

-

... More
5 HP/ 5.5 HP AHU fan motor

4

-

-

... More
7.5 HP AHU fan motor

2

-

-

... More
10 HP AHU fan motor

1

-

-

... More
M&L for taking out Cooling tower Motor (Kirlosker / CG or as per existing model) of following capacity, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of size & description to match with existing including insulating materials, varnishing, drying, replacement of both driven end & non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed. (Note:- T&P required for taking down of motor from main sprinkler shaft and necessary fabrication work viz cutting/Belding for removing and refixing of motor frame in same position is part of the scope of work and cost of the same is deemed to be included in the quoted rate)

-

-

-

... More
5 HP Cooling Tower Motor

3

-

-

... More
7.5 HP Cooling Tower Motor

2

-

-

... More
M&L for taking out condenser/chiller motor from foundation/base frame (Kirlosker/CG or as per existing) of following capacity, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of size & description to match with existing including insulating materials, varnishing, drying, replacement of both driven end & non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed:-

-

-

-

... More
15 HP Motor

1

-

-

... More
10/12.5 HP Motor

1

-

-

... More
15 HP Motor

2

-

-

... More
20 HP Motor

1

-

-

... More
Taking down condenser/ chiller pump assembly of capacity up to 10 HP (Make- Kirlosker/KSB/CG or as per existing model) form pump motor unit by disconnecting electric connection removing coupling joint servicing/grinding of impeller unit of pump replacement of gland packing, bushes, both side bearing ( as per existing model) greasing of all movable parts replacement of tyre coupling after repairing preparation of existing foundation with replacement of rusted nut bolts refixing of pump with motor all as specified and directed

2

-

-

... More
All as per item No 24.00 here-in-before but pump capacity up to 20 HP capacity.

2

-

-

... More
Supplying, fixing in replacement of pre filter (EU-4) size 610x610x50 mm of efficency 90% down to 10 micron filtration with complete set for AHU capacity up to 10500 CFM (Make - Thermadyne / Spectrum / Puromatic / Athlete)

40

-

-

... More
Supplying, fixing in replacement of pre filter (EU-4) size 610x305x50 mm of efficency 90% down to 10 micron filtration with complete set for AHU capacity up to 10500 CFM (Make - Thermadyne / Spectrum / Puromatic / Athlete)

10

-

-

... More
Supplying, fixing in replacement of FCU pre filter (EU-4) size 595x465×35 mm of efficency 90% down to 10 micron filtration with complete set for capacity up to 2500 CFM (Make - Thermadyne / Spectrum / Puromatic / Athlete)

10

-

-

... More
Supplying, fixing in replacement of FCU pre filter (EU-4) size 420x470x35 mm of efficency 90% down to 10 micron filtration with complete set for capacity up to 1500 CFM (Make - Thermadyne / Spectrum / Puromatic / Athlete)

10

-

-

... More
S&F in replacement Absolute micro filter of size 610x610x305mm having rated flow 2000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 %down to 0.3 micron, complete all as directed. Make - Thermadyne / Spectrum / Puromatic / Athlete

30

-

-

... More
S&F in replacement Absolute HEPA filter of size 610x610x50 mm having rated flow 1000 CFM, static pressure drop less than 25 mm of WG and efficiency more than 99.97 down to 0.3 micron, complete all as directed. Make - Thermadyne / Spectrum / Puromatic / Athlete

10

-

-

... More
S&F in replacement, of MCCB 100 Amp, 4 pole thermal magnetic release based with breaking capacity 16 KA, Ics = 100% Icu, with adjustable thermal magnetic setting alongwith spreader terminals (Thimble as per site requirement) and phase barriers, taking down unserviceable one complete all as directed.

6

-

-

... More
S&F in replacement, of Air circuit breaker 4 Pole 800A C curve type breaking capacity 50 KA 440 Volt 3 phase suitable for fixing in existing LT panel with taking down unserviceable one complete all as directed.

1

-

-

... More
Supply and fixing in replacement of power contractor 3 phase,415 volt,50Hz, AC, Type ML-4 2 NO plus 2 NC including coil voltage 220 volts with existing make and properly fitting in existing panel and making electric connection complete all as directed.

2

-

-

... More
Supply and fixing in replacement of power contractor 3 phase, 415 volt,50Hz, AC, Type MNX-25 including coil voltage 220 volts with existing make and properly fitting in existing panel and making electric connection complete all as directed.

4

-

-

... More
Supply and fixing in replacement of power contractor 3 phase,415 volt,50Hz, AC, Type MNX-40 including coil voltage 220 volts with existing make and properly fitting in existing panel and making electric connection complete all as directed.

4

-

-

... More
S&F in repair bimetallic thermal over load relay 9-15 Amps complete as specified and directed.

8

-

-

... More
S&F in repair bimetallic thermal over load relay 14-23 Amp complete as specified and directed.

8

-

-

... More
S&F in repair bimetallic thermal over load relay 20-33 Amp complete as specified and directed.

10

-

-

... More
S&F in repairs fan belt of Size B-42 complete as specified and directed.

24

-

-

... More
S&F in repairs fan belt of Size B-72 complete as specified and directed.

24

-

-

... More
Supply and laying in replacement LT power cable copper 6 core 1.5 Sqmm ISI mark all as specified and directed (Make-Polycab / Havells / Finolex or equivalent)

150

-

-

... More
Supply and fixing in repairs MS channel stainless steel Pre-galvanized 250 X 50 mm perforated cable tray fixed on wall/ceiling for cable duly supported with MS angle of size 50 × 50 mm including welding all as specified & directed by Engineer-in-Charge

20

-

-

... More
Supply in replacement heating element (strip heater) capacity 2 KW, ISI marked and making electric connections and taking down old unserviceable heating elements, complete all as directed. Make: Daspass/ Theata or equivelant make)

10

-

-

... More
Supply only, in replacement heating element (strip heater) capacity 1.5 KW, ISI marked and making electric connections and taking down old unserviceable heating elements, complete all as directed. Make: Daspass/ Theata or equivelant make)

10

-

-

... More
M&L for repair/servicing of main HVAC LT indoor panel board of any size/type, cleaning with blower ,checking all internal components / control accessories viz main MCCB starter assembly, contactor, relay, timer and controls wiring replacement of old lugs, nut, bolts, thimble for proper connection to main earth lead, glands to be provided/replaced as required at cable entries, fixing of front & back side broken door hinges after repair and servicing spray painting with powder coated paint with weather protection supper enameled paint of existing colour in outer/inner side of panel after cleaning and preparing surface complete all as directed. Note- Any other UNSV spares if required for replacement, same will be measured from relevant item of Schedule.

2

-

-

... More
S&F in repair including testing and commissioning of totally enclosed weather proof /water proof electric CT fan motor three phase 415 volt 50 Hz 960 RPM with connected accessories and fitting suitable for 110 TR cooling tower Make- Mihir/ Paharpur etc all as specified and directed.

2

-

-

... More
S&F in repair CT fan complete section fan dia 900 mm connected Gl nut bolt and accessories all fitting suitable for 110 TR cooling tower make- Mihir or paharpur all as directed by Engr in Charge

2

-

-

... More
S&F in repair accessories of cooling TR 110 TR viz corrosion proof PVC filling, inlet louvers drift PVC eliminators PVC water distribution chamber and PVC nozzles alongwith self rotating sprinklers system complete with Gl nut bolt and all fitting as per specified and directed by Engr in Charge. Note: (a) The spray system should be work satisfactory even with 50% reduced flow rate of water (b) The induced draught cooling tower should be operate according to counter flow principle (c) Cooling tower specification for PVC filling (delta make). Cooling tower specification for PVC filling :- (i) Capacity- 110 TR (ii) Water flow- 120 USGPM (iii) water flow in- 97.5 degree F (iv) Water out 90 degree F (v) Design wet bulb temperature - 83 Degree F (vi) Pump head -5 M

1

-

-

... More
S&F in repair square/round shape FRP induced type cooling tower casting by fiber glass reinforced casing and basin (FRP) over all appx dimension 2500mm x 2500mm x 4000 mm alongwith base frame and outer PVC mess MSHDG type mechanical equipment support electroplated hardware, inlet outlet and drain water provision GI inspection ladder steel supporting structure anti-vibration mounting suitable for 110 TR cooling tower make Mihir complete as per manufacturer’s design / specifications with all fittings as per specified and as directed.

1

-

-

... More
M&L for servicing and cleaning of cooling tower of capacity up to 110 TR by draining of water from tower cleaning of bottom surface by scrubber, repair and servicing rotating components PVC eliminators, PVC water sprinkler, nozzles viz base frame supporting arms, drift, and inlet and outlet pipe line and valves, cleaning of outer body replacement of new outer fins/mesh, rusted Gl nut bolt (included float valve) and all fitting after servicing spray painting with weather protection super enameled paint of existing colour in outer side after cleaning and preparing surface complete all as directed

4

-

-

... More
M&L for painting of condenser/chiller line size up to 300 mm bore MS/CI/GI pipe with one coat of red oxide primer and two coats of synthetic enamel paints as per existing colour code on all external steel surface after thoroughly cleaning/scraping of old paints, rust and scale etc. before applying the primer complete all as specified and as directed.

200

-

-

... More
M&L painting of pump, motor complete set including base plate, of capacity up to 10 HP motor with two coat of synthetic enamel paint after preparing surfaces all as directed.

6

-

-

... More
All as per item No 53.00 above but for motor pump set up to 15/20 HP motor pump set.

8

-

-

... More
M& L for fabrication/structural work with mild steel sheet/ angle iron in any shape or size as indicated or directed and including belding/ bracing, painting with one coat of red oxide primer and two coat of black paint (one coat before fixings and one coat of black paint after fixing) complete all as specified and directed.

1

-

-

... More
Supply only refrigerant R - 134A Gas complete all as specified and directed. (Make:- Mafron/ Freon/ Floron)

186

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.