Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date18 Jan 2025
Closing Date8 Feb 2025
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and laying in replacement PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 core including suitable size aluminium lugs properly crimpled with crimping tools including testing complete all as specified and directed

60

-

-

... More
All as per item srl No 4.00 abocve but area 300 Sqmm 3.5 core

120

-

-

... More
All as per item srl No 4.00 above but area 240 Sqmm 3.5 core

40

-

-

... More
All as per item srl No 4.00 above but area 120 Sqmm 3.5 core

160

-

-

... More
All as per item srl No 4.00 above but area 95 Sqmm 3.5 core

155

-

-

... More
Supply and laying in replecement XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 120 Sqmm 3 core including testing complete all as specified & directed

45

-

-

... More
All as per item srl No 9.00 above but area 185 Sqmm 3 core

20

-

-

... More
Supply and laying GI pipe light grade in replecement of 100mm dia laid in trenches for protection of UG cable complete all as specified & directed

12

-

-

... More
All as per item srl No 11.00 above but 80mm dia

20

-

-

... More
Taking proper shutdown & Isolate the HT electric supply and taking out the trolley of VCB/OCB HT 11KV 630 to 1250 Amps of any make and type and servicing of all minor/major parts of the VCB by cleaning isolating contact moving parts,removing dust particle from the bus bar chamber spout gear mechanism, repair to motor charge spring mechanism,tightening of all nut & bolts of entire trolley component as directed , inserting the trolley, testing the complete HT electric supply and putting on supply on load including Calibration of relay of 11KV HT VCBs installed at various sub stn at KWC area complete all as specified and directed. complete all as specified & directed. Note:- All cleaning /testing equipment/ safety equipment material shall be provided by the contractor and rate for the same shall be demed to be included in quoted rates.

12

-

-

... More
Supply only in replacement of vaccum interrupter complete all as specified and directed.

2

-

-

... More
Supply only in replacement of big gear and small gear with all fixing arrangement complete all as specified and directed.

1

-

-

... More
Supply only in replacement of closing spring assembly complete all as specified and directed.

1

-

-

... More
Supply only in replacement of tripping spring assembly complete all as specified and directed.

2

-

-

... More
Supply only in replacement of charging motor cut off limit switch complete all as specified and directed.

2

-

-

... More
Supply only in replacement of spring charging handle motorized mechanism of VCB complete all as specified and directed.

2

-

-

... More
Supply only in replacement of push button bracket assembly complete all as specified and directed.

2

-

-

... More
Supply only in replacement of bus bar support insulator 75 mm dia including all fixing accessories complete suitable for VCB/HT Bus bar chamber all as specified and directed.

4

-

-

... More
Supply only in replacement of bus bar barrier as per existing (set of three) with nuts bolts complete all as specified and directed.

3

-

-

... More
Supply only in replacement of toggle switch for space heater complete with all accessories all as specified and directed.

2

-

-

... More
Supply only in replacement of Charged/Discharged indication assembly complete all as specified and directed.

6

-

-

... More
M&L in replacement of control wiring for panel with 2.5 Sqmm copper conductor FRLSH cable including proper laying with the help of locking device as per manufacturer instruction complete all as directed

22

-

-

... More
Taking down repairable potential transformer of HT VCB 11 KV/ 110 V of any make, opening & dismentling the complete unit and refixing after carry out the following repairs/replacement :- (a) Rewinding of transformer as per existing gauge and pattern. (b) Cleaning and servicing of the PT. (c) Replacement of wornout nuts/bolts and other minor parts including HRC Fuse. (d) Soldering / tightening of loose connections. (e) Replacement of potential transformer oil having dielectric strength upto 50 KV. (f) Painting of outer portion of PT with synthetic enameled paint of grey colour of approved make. (g) Testing of the PT's for proper functioning to the entire satisfaction of GE.

2

-

-

... More
S&F in replacement of potential transformer of HT VCB 11 KV/110 V of any make complete all as specified and as directed

2

-

-

... More
S&F in replacement of 11 pin anti pumping relay 110V DC complete all as specified and directed.

5

-

-

... More
S&F in replacement of bottom terminal with jaw contact complete all as specified and directed.

1

-

-

... More
S&F in replacement of top terminal with jaw contact complete all as specified and directed.

2

-

-

... More
S&F in replacement of space heater 230V AC 80W complete with all accessories all as specified and directed.

5

-

-

... More
S&F in replacement of thermostat complete with all accessories all as specified and directed.

2

-

-

... More
S&F in replacement of PT epoxy female bushing suitable for R-Y-B phase complete all as specified and directed.

2

-

-

... More
S&F in replacement of PT epoxy male bushing suitable for R-Y-B phase complete all as specified and directed.

1

-

-

... More
S&F in replacement of PT fuse 11 KV complete all as specified and directed.

2

-

-

... More
Dehydration and filtration of transformer oil with proper dehydration machine to achieve dielectric strength between 45 to 60 KV including testing/recording of dielectric strength result before and after of dehydration complete all as specified and as directed.

2650

-

-

... More
Supply and topping up transformer oil having dielectric strength not less than 60 KV complete all as specified and directed.

250

-

-

... More
Taking shut down from main substation and drain out the transformer oil and to be collected in barrel by opening the transformer cover of capacity 400 to 500 KVA by unscrewing the nuts/bolts and washers and kept in safe custody and reuse the same, and checking any type of leakage from both HT and LT side including cleaning the sludge etc depositing in the core and tank by using soft brushes and clean with old transformer oil, refilling of transformer oil including refixing of top cover including nut/bolts etc and testing the input & output voltage and adjustment of the voltage through tape changer if required complete to the entire satisfaction of Engineer- in-charge.

1

-

-

... More
All as per srl item No 38.00 above but of capacity 630 KVA

1

-

-

... More
S&F in repair HT bushing 11KV suitable for 400 to 630 KVA Transformer including brass rod complete with gasket as per matching to existing all as specified and directed.

1

-

-

... More
S&F in repair LT bushing 11KV suitable for 400 KVA to 1000 /1500 KVA transformer including brass rod complete with gasket as per matching to existing all as specified and directed.

2

-

-

... More
S&F in repair head gasket sheet 6mm thick suitable for Transformer 400 KVA to 500 KVA capacity including replacement of nuts, bolts, washers including necessary T&P required at site complete all as specified and directed.

1

-

-

... More
S&F in repair head gasket sheet 6mm thick suitable for Transformer 630 KVA capacity including replacement of nuts, bolts, washers including necessary T&P required at site complete all as specified and directed.

1

-

-

... More
S&F in repair Dehydrating breather assembly complete with silica gel grains in the breather assembly suitable for transformers 400 KVA to 630KVA as per matching to existing complete all as specified and directed

8

-

-

... More
S&F in repair water temperature gauge analog type complete with all accessories as per matching to existing complete all as specified and directed

2

-

-

... More
S&F in repair Oil temperature gauge analog type complete with all accessories as per matching to existing complete all as specified and directed

2

-

-

... More
S&F in repair voltmeter digital type for voltage range of (0-500V) including all accessories and wiring complete all as specified and directed.

2

-

-

... More
S&F in repair ammeter digital type for current range of 0-1000 Amps as per matching to existing including all accessories and wiring complete all as specified and directed.

1

-

-

... More
S&F in repair power factor meter digital type for frequency range (45-65 Hz) as per matching to existing one including all accessories and wiring complete all as specified and directed.

3

-

-

... More
S&F in repair three phase over current earth fault relay MC-61 as per matching to existing one including all accessories and wiring complete all as specified and directed.

2

-

-

... More
S&F in repair three phase overcurrent earth fault relay MC-61A as per matching to existing one including all accessories and wiring complete all as specified and directed.

2

-

-

... More
S&F in repair LED type Indicating lamp of voltage AC/DC set of RYB, as per matching to existing complete all as specified & directed.

23

-

-

... More
S&F in repair Current Transformer as per matching to exisitng complete all as specified and directed.

3

-

-

... More
S&F in repair Multifunctional meter complete all as specified and directed

2

-

-

... More
S&F in repair VCB Power Pack unit 24 Volt DC 7 AH with battery bank for backup including panel as per matching to exisitng complete all as specified and directed

2

-

-

... More
Excavation in trenches in soft/loose soil not exceeding 1.5m depth & not exceeding 1.5m in width over energised LT cables for carrying out brick work for preparation of cable duct including for taking out and relaying of LT Cables complete all as specifed & directed

121

-

-

... More
Excavation in trenches in hard/dense soil not exceeding 1.5m depth & not exceeding 1.5m in width over energised LT cables for carrying out brick work for preparation of cable duct including for taking out and relaying of LT Cables complete all as specified & directed

8

-

-

... More
Supply & laying dry fine sand for cushioning of underground cable laid in trenches/duct complete all as specified and as directed. Note : Punned thickness shall be measured.

38.23

-

-

... More
Supply and laying in trenches burnt brick sub class 'B' standard size for cable protection keeping width of the brick parallel to the length of the cable all as specified and directed.

6.79

-

-

... More
Supply and laying un-reinforced factory made precast concrete cable cover , class HV, type 1, flat size-300x180x40 mm complete all as specified and directed

220

-

-

... More
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick as in soft/loose soil complete all as specified and directed.

80

-

-

... More
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level and not exceeding 1.5 mtr above the starting point complete all as specified and directed.

49

-

-

... More
S&F in replacement of 3 Pole MCCB, 250 Amp, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified & directed

2

-

-

... More
S&F in replacement of 3 Pole MCCB, 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified & directed

1

-

-

... More
S&F in replacement of 3 Pole MCCB, 630 Amp, 50 Hz, 415 V with rupturing capacity 50 KA complete all as specified & directed.

1

-

-

... More
S&F in replacement of 4 Pole MCCB, 250 Amp, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified & directed.

1

-

-

... More
S&F in replacement of 4 Pole MCCB, 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified & directed.

1

-

-

... More
S&F in replacement of 4 Pole MCCB, 630 Amp, 50 Hz, 415 V with rupturing capacity 50 KA complete all as specified & directed.

1

-

-

... More
S&F in repair Capacitor Bank MPP-H, 5 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.

12

-

-

... More
S&F in repair Capacitor Bank MPP-H, 10 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.

8

-

-

... More
S&F in repair Capacitor Bank MPP-H, 20 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.

5

-

-

... More
S&F in repair Capacitor Bank MPP-H, 25 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.

6

-

-

... More
Supply and laying GI pipe light grade size 40 mm dia fixed on wall/laying in trench including all connected fitting/acessories including taking old unserviceable complete all as specified and directed

40

-

-

... More
Supply and fixing Cross arms of angle iron bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape ( as per site requirment or directed by Engr -in-charge) size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint, two end of angle iron grouting in the wall upto 8 inch including clamp bend to shape with nut & bolt and finishing the wall with cement mortar complete all as specified and directed

1.5

-

-

... More
Dismantling old rusted cross-arms of M.S. channel or angle sections etc. and setting aside with in 50 mtr complete all as specified and directed.

1

-

-

... More
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:- (a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.Angle iron frame made of 40x40x4 mm angle iron for 30x30 cm PCC pit for holding the pit cover and Apply two coat of syntheticnenamel paint over one coat of red oxide zinc chrome primer on exposed steel surfaces and two coat of hot tar on embedded portion of steel surfaces

15

-

-

... More
M&L Galvanised iron strip 25x4mm buried in ground including necessay excavation & earth work in soft/loose soil and removal of excavated naterial n. exc 50m and depositing where directed.

95

-

-

... More
Supplying and laying synthetic Rubber insulated mats for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety. The upper surface having small anti skid aberration marks to avoid slippery effect and lower surface is plane of size 2m x 1m x 2mm thick for voltage upto 3.3 KV complete all as specified and as directed.

15

-

-

... More
Supplying and laying synthetic Rubber insulated mats for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety. The upper surface having small anti skid aberration marks to avoid slippery effect and lower surface is plane of size 2m x 1m x 2.5mm thick for voltage upto 11 KV complete all as specified and as directed.

10

-

-

... More
M&L MS chequred plate of suitable size for cable duct cover 6mm thick and earth pit cover all as specified and directed.

810

-

-

... More
Supply only Electrical insulation HT tape of 3/4"width of 30 feet length Etylene Propylene backing highly comfortable to wrap snugly over most any shape streches up 100 percent to provide avoid moisture, resistant insulation tape of Make-Scotch.

14

-

-

... More
Supply only Fix CRC 2-23 Electrical equipment (contact) cleaner spray used for prevent electronic malfunction equipment caused by water penetration, humidity, corrosion etc and of 500ml can complete all as specified and directed.

6

-

-

... More
Supply and Fix earth pit chamber alongwith cover of Polymer, FRP Pit cover of heavy high grade polypropelene for high stress and starin level of size 225x300x195mm complete all as specified and directed.

7

-

-

... More
S&F ACP retro sign board of size 1.5x1.1 Mtr using retro reflective high intensity prismatic reflective sheeting. The back ground of board is Blue Colour with white border and writing letter, numbers white colour mentioning the HT/LT substation Details, and Single line Schematic diagram of substation. Retro sign board shall be pasted on 3mm thick ACP sheet. The board shall be fixed on Wall including fixing of fastners, nuts, bolts, washer etc complete all as directed by Engineer-in-Charge at site.

2

-

-

... More
Removing and replacing the old unserviceable lead acid battery of size 12 Volt, 42 AH of reputed make including charging all as specified as directed (Make : Amaron, Exide)

12

-

-

... More
S&F LED flood light with pressure die cast aluminium housing 150 Watt completed with connection including taking down old unserviceable .

12

-

-

... More
S&F LED flood light with pressure die cast aluminium housing 200 Watt completed with connection including taking down old unserviceable

8

-

-

... More
Design, fabrication, assembling, wiring, supply installation, testing and commissioning in replacement of LT panel, suitable for outdoor installation, factory fabricated out of CRCA sheet steel 2mm for non-load bearing members and 3.15mm for load bearing members in cubicle formation, compartmentalized, from 3b construction & IP-65 in acc. with IEC 60529 protection, free standing floor mounted, dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and / or flats wherever necessary with extensible type TPN aluminum alloy bus bars of high conductivity,DMC/SMC with supports with short circuit withstand capacity of 31 MVA for 1 sec.Panel shall have a common copper earth bar with 2 nos. earth stud. 3 mm thick cable gland plates shall be provided on top as well as at the bottom of the panels with anti-condensation space heater. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 Nos. earthling terminals shall be provided for all distribution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system duly internal wiring with pvc insulated FRLS multistranded copper conductor cable of suitable sizeand copper thimble etc.. Lifting hooks shall also be provide din case of large panels. Approval shall be taken for panel in the form of shop drawings before fabrication. Galvanized hardware's with zinc passivation shall be used in fabrication of panels in and including of taking out old us panel. Panel shall be consisting with following:-

1

-

-

... More
Incomer : 800 Amps, 50KA, 4P EDO type Microprocessor based Air Circuit Breaker with ON/OFF/TRIP indicating lamps with MCB's and over current, short circuit and earth fault releases - 1 No. Bus-Bar : 2000 Amp, 50 KA, 3 Phase and Nutral Aluminum bus bars of high conductivity electrolytic quality aluminum alloy with colored heat shrinkable insulated sleeve.-1 Set. Instruments : Multifunction Meter including CT's of suitable size- 1 set. RYB phase indicating lamps LED type controlled by, MCB-1 Set Outgoing : 250 Amp 4P MCCB,25kA with RYB phase indicating lamps LED type controlled by, MCB - 1 Nos. 200 Amp 4P MCCB,25kA with RYB phase indicating lamps LED type controlled by, MCB - 2 Nos. 160 Amp 4P MCCB,25kA with RYB phase indicating lamps LED type controlled by, MCB - 2 Nos. 100 Amp 4P MCCB,25kA with RYB phase indicating lamps LED type controlled by, MCB - 3 Nos.

-

-

-

... More
Note: * All MCCB above 200A shall have microprocessor release unit with s/c, o/c & e/f protection. ( ICS as 100% ICU ) * All MCCB up to 200A shall be Thermal agnatic release unit with s/c & o/c protection.( ICS as 100% ICU) * All MCCB/MPCB shall be digital VAF Meter with CT's, LED type ON,OFF & TRIP indicating lamps and operating handle. * All MCB shall be 10kA with 'C' Curve . * All MPCB shall be Type '2' Co-ordination and having s/c, o/c & s/f protection .

-

-

-

... More
Design, fabrication, assembling, wiring, supply installation, testing and commissioning in replacement of LT panel, suitable for outdoor installation, factory fabricated out of CRCA sheet steel 2mm for non-load bearing members and 3.15mm for load bearing members in cubicle formation, compartmentalized, from 3b construction & IP-65 in acc. with IEC 60529 protection, free standing floor mounted, dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and / or flats wherever necessary with extensible type TPN aluminum alloy bus bars of high conductivity,DMC/SMC with supports with short circuit withstand capacity of 31 MVA for 1 sec.Panel shall have a common copper earth bar with 2 nos. earth stud. 3 mm thick cable gland plates shall be provided on top as well as at the bottom of the panels with anti-condensation space heater. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 Nos. earthling terminals shall be provided for all distribution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system duly internal wiring with pvc insulated FRLS multistranded copper conductor cable of suitable sizeand copper thimble etc.. Lifting hooks shall also be provide din case of large panels. Approval shall be taken for panel in the form of shop drawings before fabrication. Galvanized hardware's with zinc passivation shall be used in fabrication of panels in and including of taking out old us panel. Panel shall be consisting with following:-

1

-

-

... More
Incomer : 630 Amps, 50KA, 4P EDO type Microprocessor based MCCB with ON/OFF/TRIP indicating lamps with MCB's and over current, short circuit and earth fault releases - 1 No. Bus-Bar : 1500 Amp, 50 KA, 3 Phase and Nutral Aluminum bus bars of high conductivity electrolytic quality aluminum alloy with colored heat shrinkable insulated sleeve.-1 Set. Instruments : Multifunction Meter including CT's of suitable size- 1 set. RYB phase indicating lamps LED type controlled by, MCB-1 Set Outgoing : 200 Amp 4P MCCB,25kA with RYB phase indicating lamps LED type controlled by, MCB - 2 Nos. 100 Amp 4P MCCB,25kA with RYB phase indicating lamps LED type controlled by, MCB - 03 Nos Note: * All MCCB above 200A shall have microprocessor release unit with s/c, o/c & e/f protection. ( ICS as 100% ICU ) * All MCCB up to 200A shall be Thermal agnatic release unit with s/c & o/c protection.( ICS as 100% ICU) * All MCCB/MPCB shall be digital VAF Meter with CT's, LED type ON,OFF & TRIP indicating lamps and operating handle. * All MCB shall be 10kA with 'C' Curve . * All MPCB shall be Type '2' Co-ordination and having s/c, o/c & s/f protection .

-

-

-

... More
Supply & fixing in replacement manually change over switch of 300 amps 415 V with sheet steel inclosures, mounting on wall including fiting accessories

1

-

-

... More
S&F in replacement sector lugs (long barrel type) for HT connection of size upto 150 sqmm 3 core.

35

-

-

... More
S&F in replacement aluminium sector lugs (long barrel type) for HT connection of size 185 to 400 sqmm 3 core.

23

-

-

... More
S&F in replacement aluminium sector lugs (long barrel type) for HT connection of size 500 to 630 sqmm 3 core.

25

-

-

... More
S&F in replacement aluminium sector lugs (short barrel type) for LT connection of size up to 50 sqmm 3.5 core.

25

-

-

... More
S&F in replacement aluminiumsector lugs (short barrel type) for LT connection of size 70 to 95 sqmm 3.5 core.

27

-

-

... More
S&F in replacement aluminiumsector lugs (short barrel type) for LT connection of size 120 to 185 sqmm 3.5 core.

30

-

-

... More
S&F in replacement aluminium sector lugs (short barrel type) for LT connection of size 240 sqmm 3.5 core.

35

-

-

... More
S&F in replacement aluminium sector lugs (short barrel type) for LT connection of size 300 sqmm 3.5 core.

36

-

-

... More
S&F in replacement aluminium sector lugs (short barrel type) for LT connection of size 400 sqmm 3.5 core.

40

-

-

... More
S&F in replacement aluminium sector lugs (short barrel type) for LT connection of size 630 sqmm 3.5 core.

30

-

-

... More
Material and labour for shifting of VCB 630 Amps from one location to another location in the complex permises including diconnecting at both exiting site and laying at new site with all connections, checking thoroughly serviceability of the parts, fixing the serviceable parts in positiion, replacement of the defective/non functional/unserviceable parts/spares, reassembling, commissioning, fixing in position and testing for its smooth and trouble free operation complete all as specified and directed

2

-

-

... More
Taking shutdown from sub-station & Painting and Servicing of LT feeder panel boards complete with removal of the dust, tightening of electrical connections, replacement of burnt nut/bolts with washers, replacement of connections wires as per power load requirement, including insulation tapping complete all as specified and directed by Engineer-In-charge.

8

-

-

... More
Taking shutdown from LT panel & Servicing of Distribution Boards any type complete with removal of the dust, tightening of electrical connections, replacement of burnt nut/bolts with washers, replacement of connections wires as per power load requirement, including insulation tapping complete all as specified and directed by Engineer-In-charge.

20

-

-

... More
Taking proper shutdown , disconnecting the LT and HT electric main from transformer of any capacity, removing the transfomer of any capacity from pole/structure/ platform shifting to authorised workshop after draining out the transformer oil at site, dismantling and disconnecting damaged HT/LT coil to facilate necessary repairs, rewinding/reconditioning reassembling the tranformer, bringing back to the site, taking out dehydrated old trasformer oil and connecting with existing electrical system of HT and LT including testing complete all as specified and directed. (winding wire and othe items mentioned in schedule will be measured and paid separately)

1

-

-

... More
Rewinding/reinsulation of LT/HT coils of any size and type of transformer including cleaning the brunt out insulating materials, brazing and rewinding with appropriate turns and size of super enamelled DPC insulated copper winding wire of appropriate gauge including filling insulation paper etc all as specified and directed by engr-in-chage Note :- (i) Weight, number of turns, gauge, insulation of winding wire shall be as per OEM. (ii) Work of rewinding shall be carried out through OEM or their authorised vender only.

179

-

-

... More
Supply only 11KV VCB trolly having 18.4KA 1250 Amp acumm Intererrupers as per existing make for DRDO sub stn to maintained for reliable electric suppluy complete all as specified & directed.

1

-

-

... More
M&L for bringing cable testing van (fault locator) for detecting the location of the fault in the LT UG cable 1.1 KV of any size complete all as specifiec and directed.

6

-

-

... More
M&L in replacement of heat shrinkable straight through jointing kit for LT 1.1 KV XLPE cable 185 to 630 sqmm 3.5 core including all accessories required

6

-

-

... More
M&L in replacement of heat shrinkable straight through jointing kit for LT 1.1 KV XLPE cable 70 to 150 sqmm 3.5 core including all accessories required

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.