Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_694244_1Tender No
GE/DS-119/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR/MAINT OF OVERHEAD LINES, TRANSFORMERS, ELECTRIC POLES, VCBs, RMUs AND CONNECTED ACCESSORIES AT KHANPUR ARMY CAMP, MANESAR ARMY CAMP, DUNDAHERA MIL STN AND INDU BINOLA UNIVERSITY UNDER AGE E/M OF GE (SOUTH) DELHI CANTT-10
BOQ Items
... More
M&L for transportation of transformer of capacity upto 400 KVA from site location to workshop using Hydra/Crane and truck as per requirement to replace defective transformer including installation, testing and connecting at site and to deposit the same to site location after receipt and installation of repaired transformer at site complete all as specified and as directed.
Note:- Contractor must arrange for transportation and installation for replacement of transformer at site immediately after receipt of verbal/telephonic/written complaint from JE/Engr-in-Charge within 1 day. Any delay beyond 1 day post receipt of complaint shall be penalized @ Rs 2500/- per day and shall be recovered from the RAR.
3
-
-
... More
M&L for alternative arrangement by hiring, transportation of transformer of capacity up to 400 KVA in place of unserviceable transformer on hire basis for 15 days including, installation, connecting and testing of transformer and return back after installation of repaired transformer complete all as specified and as directed.
3
-
-
... More
Notes:-
(i) Contractor must arrange hired transformer including transportation and installation at site immediately after receipt of verbal/telephonic/written complaint from JE/Engr-in-Charge within 1 day. Any delay beyond 1 day post receipt of complaint shall be penalized @ Rs 3500/- per day and shall be recovered from the RAR.
(ii) Repairing of transformer must be completed within 15 days after receipt of verbal/ telephonic/ written complaint from JE/Engr-in-Charge. In case of any delay, no extra claim will be entertained towards hiring charges beyond 15 days and the contractor shall not be allowed to shift the hired transformer until replaced by repaired transformer. In case of any kind of fault / defect occurred in hired transformer, the contractor shall have to arrange further replacement without any additional cost and shall repair the defect from his own expenses.
(iii) Contractor should check the available infrastructure and to be sure regarding safety of hired transformer before installation. The rate quoted is deemed to be including transportation cost, earthing lead etc.
-
-
-
... More
Taking out unserviceable copper winding wire from transformer of capacity upto 250 KVA after opening top cover and carrying out the following works complete all as specified and as directed:-
(a) Dismantling of all attachment viz breather assembly, conservator, oil temperature gauge, HT/LT bushing etc. and keeping aside for reuse.
(b) Taking out the core with winding assembly.
(c) Removing of complete winding from core and dismantling the core, cleaning of core laminate sheet and keeping aside for reuse
(d) Cleaning of complete transformer tank oil fins, removing of sludge, and making the inside surface of tank dry by blowing of hot air as directed and specified.
1
-
-
... More
All as per item No.6 above, but capacity of transformer from 315 to 400 KVA.
2
-
-
... More
Note for Item Nos.06 & 07 : - In case the defective transformer not repaired & installed at site within the specified period of 15 days from the date of handing over of defective transformer/complaint to contractor, a penalty recovery @ Rs 500/- per day will be charged from his dues/RAR.
-
-
-
... More
(a) M&L for repairing the transformer of capacity upto 250 KVA with following activities complete all as specified and as directed:-
(i) Rewinding of HT/LT leg coil complete using copper wire /strip of appropriate gauge, size and turn as per existing with double paper coated insulation including all requisite insulating materials like packing sleeves, separator, tapes etc. heating, varnishing the core and winding assembly after framing up top and bottom steel structure of transformer as required and directed. (ii) Replacement of all insulating materials other than incorporated for rewinding of HT/LT coils as per existing.
(iii) Fixing only HT procelain bushing with studs, nuts, washers 3 Nos. and LT procelain bushing with studs, nuts, and washers 4 Nos. and connection with primary and secondary windings and reconnecting with the main terminals as required and directed. (iv) Fixing only breather assembly, conservator, oil temperature gauge after proper cleaning, minor repairs etc. as required and directed.
(v) Replacement of all unserviceable gasket from top cover, HT/LT bushing with new one by using rubberised gasket sheet 4.0mm/6.0mm thick duly pasted with suitable adhesive .
1
-
-
... More
(vi) Replacement of unserviceable bolts with new one and fixing of existing serviceable bolts, nuts, washers of different sizes and tightening properly.
(vii) Repositioning of core and winding assembly inside the tank, assembling complete unit and making the transformer ready for filling oil and subsequent testing as directed. (viii) Filling/topping up of new transformer oil of required quantitiy.
(b) M&L for transportation of repaired transformer to the original position (from where taken-down), disconnecting the alternative transformer, taking down the same, Re-installation of repaired indoor/outdoor transformer on 4/6 pole structure/plinth/inside sub station, connecting electrically and mechanically, testing and commissioning complete all as specified and directed. (c) The following routine test as per IS 2026 (Part I) -1977 shall be carried out at repairing workshop/manufacturer having NABL Lab accredition and valid calibration of test equipments and shall submit MOU with any repairing workshop/manufacturer as per format attached along with quoted tender, bid shall be rejected in case of non submission of MOU/MOU from non qualified repair workshop/manufacturer :
(i) Measurement of winding resistance.
(ii) Measurement of voltage ratio and check of voltage vector relationship.
(iii) Measurement of impedance voltage/short circuit impedance (principal tapping) and load loss .
(iv) Measurement of no load loss and current.
(v) Measurement of insulation resistance.
(vi) Dielectric tests
(d) The contractor shall give written warranty of five years from the date of sucessfull testing and installation of transformer. The contractor shall submit test report from repair workshop/manufacturer for above mentioned test. Note :-HT/LT leg coils copper wire/strip and transformer oil required shall be measured and paid separately under relevant items of this Schedule here-in-after as supply only.
-
-
-
... More
All as per item No.8 here-in-before, but capacity of transformer 315 to 400 KVA.
2
-
-
... More
Supply only HT coils with super enamelled copper wire/DPC of high quality duly matching with the existing guage and impedance complete all as specified and as directed.
460
-
-
... More
Supply only LT coils with super enamelled copper wire strip/DPC of high quality duly matching with the existing guage and impedance complete all as specified and as directed.
300
-
-
... More
M&L for ON load Centrifuging and dehydration including filteration and cleaning of transformer oil by dehydration machine of 11/0.433 KV transformer installed at various site on plinth 2/4 pole structure of any capacity and topping up deficient transformer oil including testing of samples before and after dehydration and filteration complete all as specified and as directed.
Note :- Deficient quantity of Transformer oil required for top up shall be measured and paid separately under item No 13 here-in -after as supply only.
2100
-
-
... More
Supply only in replacement transformer oil of approved quality as per IS having dielectric strength of 45-60 KV in 2.5mm gap for filling in transformer or for topping up as required complete all as specified and as directed.
950
-
-
... More
S&F in repairs Porcelain Transformer bushing on LT (440 Volt) side, including brass stems conical bush and gasket after disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 160 KVA and re-connecting electrically and mechanically, testing complete all as specified and as directed. Note.The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil, opening of top cover by unscrewing nut, bolts washers and provision of pad type bus bar almuminium of approppiate size /capacities of transformers with nut bolt & washers.
4
-
-
... More
All as per Serial item No.14 above, but capacity 200 KVA to 315 KVA
4
-
-
... More
All as per Serial item No 14 above, but capacity 400 KVA
4
-
-
... More
S&F in repairs Porcelain Transformer bushing on HT (11 KV) side, including brass stems conical bush and gasket after disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 160 KVA and connecting electrically and mechanically, testing complete all as specified and as directed. Note:-The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil, opening of top cover by unscrewing nut, bolts washers and connections.
3
-
-
... More
All as per Serial item No.17 above, but 200 KVA to 315 KVA
3
-
-
... More
All as per Serial item No.17 above, but 400 KVA
3
-
-
... More
S&F in repairs all unserviceable gasket after disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 160 KVA and re-connecting electrically and mechanically, testing complete all as specified and as directed. Note:- The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil, opening of top cover by unscrewing nut, bolts washers etc.
4
-
-
... More
All as per Serial item No.20 above, but 200 KVA to 315 KVA
4
-
-
... More
All as per Serial item No.20 above, but 400 KVA
4
-
-
... More
S&F in repairs Silica Gel Breather assembly including vent pipe and Silica Gel for indoor/outdoor transformers, capacity upto 400 KVA complete all as specified and as directed.
5
-
-
... More
S&F in repairs thermometer of transformer upto capacity 400 KVA complete all as specified and as directed.
1
-
-
... More
S&F in repairs cross arms, bracings, supports, channel,clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete including taking out existing supports of wooden pieces for holding overhead conductor complete all as specified and as directed.
2
-
-
... More
Dismantling burnt/defective Gang Operated Switch including removing from site and Supply & installing 11 KV 3 Phase Gang operated air break switch with drop out fuses set (consisting 12 Nos Post Insulator) 400 amp capacity, vertical mounting with fixed and moving contacts complete with locking arrangement and fixing the gang operated switch on existing two/four pole structure including making all jumper connections with insulated leads of suitable size with line tops etc. complete all as specified and as directed.
3
-
-
... More
S&F in repairs lightening arrestor explusion type complete with all fittings, transmission class, discharge capacity 65KA and suitable for working voltage 11000 volts complete all as specified and as directed.
12
-
-
... More
S&F in repairs danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with & including M.S. clamps, bolts and nuts of approved size, for LT of 20x15cm size complete all as specified and as directed.
10
-
-
... More
S&F in repairs danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with & including M.S. clamps, bolts and nuts of approved size, for HT of 25x20cm size complete all as specified and as directed.
5
-
-
... More
Cleaning, preparing and painting with one coat of super enamelled aluminium paint over two coats of red oxide primer to cross arms, MS channels, angle iron, frame work etc. on pre-stressed HT concrete 2 pole/4 pole structure complete all as specified and as directed.
2
-
-
... More
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised iron strip 25x4 mm by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No.5 of SSR 2009 Part-I and connecting to Transformer/Poles all as specified or indicated including testing on complete all as specified and as directed.
2
-
-
... More
S&F in replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing/connecting as required 25x4 mm galvanised iron strip complete all as specified and as directed.
15
-
-
... More
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised earth lead wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 5 of SSR 2009 Part-I and connecting to Poles all as specified or indicated including testing on complete all as specified and as directed.
5
-
-
... More
S&F in replacement test point terminal block made of gun metal or phosphorus bronze size gun metal or phosphorus bronze size 75 X 75 X 25 mm, drilled and screwed including 3 nos. 8mm dia 25 mm long hex. Head screw complete all as specified and as directed.
10
-
-
... More
S&F in replacement synthetic insulating mat of size 2m x 1m x 12 mm thick complete all as specified and as directed.
8
-
-
... More
S&F in repairs HT brass stem, 11000 volts, 50 Hz suitable for transformer 11/0.433 KV, 250 to 400 KVA capacity of any make complete with one chuck nut, two nuts, washers and rubber seal (as per sample) complete all as specified and as directed.
3
-
-
... More
S&F in repairs HT brass stem, 11000 volts, 50 Hz suitable for transformer 11/0.433 KV, 100 to 200 KVA capacity of any make complete with one chuck nut, two nuts, washers and rubber seal (as per sample) complete all as specified and as directed.
3
-
-
... More
S&F in repairs LT brass stem, 1100 volts, 50 Hz suitable for transformer 11/0.433 KV, 250 to 400 KVA capacity of any make complete with one chuck nut, two nuts, washers and rubber seal (as per sample) complete all as specified and as directed.
3
-
-
... More
S&F in repairs LT brass stem, 1100 volts, 50 Hz suitable for transformer 11/0.433 KV, 100 to 200 KVA capacity of any make complete with one chuck nut, two nuts, washers and rubber seal (as per sample) complete all as specified and as directed.
3
-
-
... More
Disconnecting HT supply from 11 KV, 630 Amps RMU, 2/3/4 way and servicing and overhauling of RMU, checking of tripping mechanism, greasing of moving contacts, cleaning of carbon from main contacts, checking of spring tension, Checking of loosened bolts and nuts, checking of loosened connections, rust, damaged lead wires, checking of spring charging motor, Improvement of resistance of CTs, PT, epoxy insulator and epoxy body by applying post heated varnish and testing on load complete all as specified and as directed
4
-
-
... More
M&L for checking the existing pressure of SF6 Gas in Gas Chamber of 11 KV , 630 Amps RMU , 2/3/4 way before filling and topping up the SF6 gas in the chamber of RMU including supervision of gas filling/topping up process and checking the pressure of gas after filling complete all as specified and as directed at site.
2
-
-
... More
S&F in repairs operating mechanism (2PA Mechanism W/O hex Rod) for 11 KV, 630 Amps RMU, 2/3/4 way complete all as specified and as directed.
1
-
-
... More
S&F in repairs cable Boots 11 KV, in 630 Amps RMU, 2/3/4 way complete all as specified and as directed.
3
-
-
... More
S&F in repairs associated ring-core cast-resin insulated CTs 100/50/1 -1 Amp , 2.5 VA, 10P10 for protection in 11 KV, 630 Amps RMU complete all as specified and as directed.
2
-
-
... More
S&F in repairs 1-Ph (11kV/rt3):110VAC, 500VA Auxiliary transformer in 11 KV, 630 Amps RMU (Ring main unit) complete all as specified and as directed.
2
-
-
... More
S&F in repairs closing coil assembly suitable for RMU 630 A complete all as specified and as directed.
1
-
-
... More
S&F in repairs tripping coil assembly suitable for RMU 630 A complete all as specified and as directed.
1
-
-
... More
M&L for servicing /testing of breaker/control panel including CT, PT and relays in control panel of VCB of capacity 630 Amps and rating 11 KV complete all as specified and as directed for the details as mentioned under:-
(a) Details of servicing of breaker :-
(i) Adjustment of mechanism if required.
(ii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth.
(iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts.
(iv) Check for rust and wear.
(v) Check Spring Tension and pitting of the Cluster Contacts.
(vi) Visual check for rust and deformation.
(vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc.
(viii) Check for loosened connections, rust, damaged lead wires.
(ix) Check whether the contacts are damaged by arcing.
(x) Checking of control circuit & tighten the connections if any.
(xi) Check close & trip coil.
(xii) Checking of Jaw Contacts Conditions and repair/adjust.
(xiii) Replace the jaw contacts,If required.
(xiv) Improvement of resistance of epoxy insulator and epoxy body by applying post heated varnish.
(xv) Replacement of Dashpot/shock absorbers .
(xvi) Replacement of carbon brush of spring charging motor.
4
-
-
... More
(b) The following test shall be carried out:-
(i) Primary Injection Test of CT / PT
(ii) Closing & Opening Timing Test for all three poles.
(iii) IR Test with megger in open and closed condition.
(iv) Contact resistance test for all three poles
(v) Closing coil resistance
(vi) Tripping coil resistance.
(c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :-
(i) Over current and earth fault relay
(d) Testing of followig Aux relay
(i) DC Supply supervision relay.
(ii) Master trip relay
-
-
-
... More
S&F in repairs tripping push button as per sample suitable for VCB/OCB11 KV complete all as specified and as directed.
1
-
-
... More
S&F in repairs closing coil assembly suitable for VCB 11 KV complete all as specified and as directed.
1
-
-
... More
S&F in repairs tripping coil assembly suitable for VCB 11 KV complete all as specified and as directed.
1
-
-
... More
S&F in repairs earth contact assembly suitable for VCB 11 KV complete all as specified and as directed.
1
-
-
... More
S&F in repairs spring charging mechanism assembly suitable for VCB 11 KV complete all as specified and as directed.
1
-
-
... More
S&F in repairs spring charged indicator suitable for VCB 11 KV complete all as specified and as directed.
1
-
-
... More
S&F in repairs ON/OFF indicator suitable for VCB/OCB 11 KV complete all as specified and as directed.
2
-
-
... More
S&F in repairs auxiliary switch suitable for VCB 11 KV complete all as specified and as directed.
1
-
-
... More
S&F in repairs vacuum interreputer bottle 400/630 Amps, 11KV per phase suitable for VCB complete as per sample and complete all as specified and as directed.
2
-
-
... More
S&F in repairs moving contact assembly suitable for VCB 11 KV complete all as specified and as directed.
1
-
-
... More
S&F in repairs fixed contact assembly suitable for VCB 11 KV complete all as specified and as directed.
1
-
-
... More
S&F in repairs motor & gear assembly for spring charging suitable for VCB 11 KV complete all as specified and as directed.
1
-
-
... More
S&F in repairs main shaft inter lock assembly suitable for VCB 11 KV complete all as specified and as directed.
1
-
-
... More
S&F in repairs space heater with thermostat suitable for VCB 11 KV complete all as specified and as directed.
1
-
-
... More
S&F in repairs power pack unit suitable for 230 volts, 50 Hz AC input voltage and 3 Nos of output voltage i.e. 110, 24 & 12 volts DC complete with battery back up (minimum 2 Nos x 7 AH capacity battery) suitable for operation of HT VCB 11 KV matching with existing system complete all as specified and as directed.
1
-
-
... More
S&F in repairs ON/OFF switch with NO/NC contact suitable for VCB/OCB 11 KV complete all as specified and as directed.
2
-
-
... More
S&F in repairs indicating lamp LED type in red, yellow, blue suitable for VCB 11 KV Panel complete all as specified and as directed.
1
-
-
... More
S&F in repairs indoor type 3 phase 11KV/110V potential transformer, 12KV, 50 Hz, earthed type, draw-out type with accuracy class 0.5 for metering & protection, rated burden both winding 100VA, hermetically sealed to eliminate breathing and prevent air & moisture, secondary terminal should be partitioned so as to house the metering terminals separately from protection & various terminal connectors providing sufficient earth clearance complete all as specified and as directed.
1
-
-
... More
S&F in repairs 11 KV current transformer, cast resin type, 50 Hz with ratio of 600-400/5 Amps having protection & metering core, 15 VA burden or as matching with existing, class 1.0 of minimum breaking capacity 13.10 KV for 1.0 second complete all as specified and as directed.
2
-
-
... More
S&F in repairs master tripping relay suitable for protection/tripping of HT 11 KV VCBs Panel including carry out necessary modification in existing panel complete all as specified and as directed.
1
-
-
... More
S&F in repairs electromechanical type over current relay (inverse) type, CDG type with range 2.5 to 10.0 Amps in 7 steps suitable for protection/tripping of HT 11 KV VCBs/OCBs Panel including carry out necessary modification in existing panel complete all as specified and as directed.
2
-
-
... More
S&F in repairs electromechanical type earth fault relay (inverse) type, CDG type with range 1.0 to 4.0 Amps in 7 steps suitable for protection/tripping of HT 11 KV VCBs/OCBs Panel including carry out necessary modification in existing panel complete all as specified and as directed.
1
-
-
... More
M&L for preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner, applying two coats of synthetic enamel paint by spray machine on all sides of 11 KV VCB panel including writing of MES /SM No and details of feeder as directed by Engr-in-Charge on graphic plastic sheet complete all as specified and as directed.
1
-
-
... More
S&F in replacement PT fuse failure relay, 50/24 Volt DC in control panel including wiring complete all as specified and as directed.
2
-
-
... More
Supply, Installation, testing & commissioning of following items/spares in the existing panel of automatic power factor improvement (outdoor) capacitor bank having aggregate capacity 100 KVAR to 250 KVAR (As per site requirment) in different stage with microprocessor along with factory made type panel board including taking down old/unservicable following parts complete all as specified and as directed:-
-
-
-
... More
Power factor corrector relay 8 to 10 Stage.
1
-
-
... More
Capacitor duty contactor for 25 KVAR.
3
-
-
... More
Capacitor duty contactor for 20 KVAR.
2
-
-
... More
Capacitor duty contactor for 15 KVAR.
3
-
-
... More
Capacitor duty contactor for 10 KVAR.
3
-
-
... More
Capacitor duty contactor for 5 KVAR.
5
-
-
... More
A/M selector switch.
2
-
-
... More
ON-OFF push button.
5
-
-
... More
Aux Contactor 4 No + 4 NC.
3
-
-
... More
Indicating lamp ON-OFF.
6
-
-
... More
Power factor 25 KVAR ultra heavy duty MPP type having tolerance 0% with discharge device resistor.
2
-
-
... More
Power factor 20 KVAR ultra heavy duty MPP type having tolerance 0% with discharge device resistor.
2
-
-
... More
Power factor 15 KVAR ultra heavy duty MPP type having tolerance 0% with discharge device resistor.
3
-
-
... More
Power factor 10 KVAR ultra heavy duty MPP type having tolerance 0% with discharge device resistor.
4
-
-
... More
Power factor 5 KVAR ultra heavy duty MPP type having tolerance 0% with discharge device resistor.
4
-
-
... More
Digital Voltmeter 0-500 V with VSS.
4
-
-
... More
Digital Ammeter 0-400 A with VSS & CT.
4
-
-
... More
Supply and installation of Harmonic filter for APFC panel including taking down of old unsv harmonic filter by proper isolation of all the connection of cable/busbar and reconnecting complete all as specified and as directed.
2
-
-
... More
M&L for Servicing of complete APFC panel upto 250 KVAR including cleaning of the terminal and coil and incoming & outgoing connections fixed with high tensile nut and bolts fixed and associated wiring of the auxiliary blocks and Manual functional testing of the Panel after servicing by directly giving command from the terminal blocks with all required tools, manpower and Assembling the panel after servicing , closing and mounting of all components. Cleaning of the Panel with Vacuum cleaner/blower ensuring that no control and power wiring is disturbed during the work complete all as specified and as directed.
6
-
-
... More
Restringing of LT OH conductor ACSR including binding of conductor making jumper connection etc complete all as specified and as directed.
1800
-
-
... More
Cutting of tree branches touching or leaning over overhead power lines and removing of cut tree branches from the site complete all as specified and as directed.
2200
-
-
... More
Dismantling the existing unserviceable stay assembly complete using stay rod of any size/type including breaking of PCC foundation and throwing away demolished materials at low laying areas and making good disturbed surface complete all as specified and as directed.
3
-
-
... More
M&L for stay assembly complete using stay rod of 20 mm dia complete with accessories as shown in electrical plate No.1 of SSR-2009, Part-I complete all as specified and as directed. Note:-Loop type insulator excavation, stay clamp, nuts, bolts, washers and concrete to be measured and paid separately.
3
-
-
... More
Excavation in trenches in any type of soil n.exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, foundation filling of poles or stays etc. complete all as specified and as directed.
2.16
-
-
... More
S&F in repairs Anti-Climbing device spike type fabricated out of MS bars (round, square and flat) including nuts,bolts and washers and welding into two halves made to shape to suit the cross section of the pole including taking down of old unserviceable anti climbing device complete all as specified and as directed.
0.5
-
-
... More
S&F in repairs PVC Line spacer of superior quality of 2 Way spiral type complete all as specified and as directed.
10
-
-
... More
S&F in repairs PVC Line spacer of superior quality of 4 Way spiral type complete all as specified and as directed.
10
-
-
... More
S&F in repairs aluminum conductor steel reinforced (ACSR) of size 1 of 6/1x2.59mm (Weasel) for LT lines on pre-stressed concrete poles, streching without kinks and bends including dismantling & taking down of old unserviceable ACSR conductor complete all as specified and as directed.
2.56
-
-
... More
Supply & stringing Galvanised steel earth wire of 4mm dia with hooks, streching kinks and bends including dismantling and taking down galvanised steel complete all as specified and as directed.
0.6
-
-
... More
Dismantling & taking down insulator any type any size from LT/HT poles complete all as specified and as directed
70
-
-
... More
S&F in repairs Pin Insulator, porcelain, vitreous white, brown or green insulator incl one galvanized mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100 mm height , 65 mm dia for 1100 volts grade complete all as specified and as directed.
40
-
-
... More
S&F in repairs Disc type Porcelain Insulator, vitreous brown, large size with overall dimension 145x250mm clearence of hole 25.5 mm, working pressure 11000 volts complete all as specified and as directed.
10
-
-
... More
S&F in repairs Shackle type, porcelain, vitreous white, brown or green insulator incl one galvanized mild steel straps, washers insulator bolts, washers & nut 75 mm height, 90mm dia for 1100V grade complete all as specified and as directed.
20
-
-
... More
S&F in repairs Loop Insulator, porcelain, vitreous white, brown or green large size with overall dimension 90x140mm clearence of hole 25.5 mm complete all as specified and as directed.
5
-
-
... More
S&F in repairs Prestressed concrete pole, 11.0 metres long. 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 complete with cast iron base plate, finial taper plug, bolts, nuts & screws complete all as specified and as directed.
5
-
-
... More
S&F in repairs Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and l2mm x 279mm at bottom,class 10 complete with cast iron base plate, finial taper plug, bolts, nuts & screws complete all as specified and as directed.
20
-
-
... More
S&F in repairs Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws asspecified type 410 SP-31 (9.0 metres long) complete all as specified and as directed.
10
-
-
... More
M&L for cement concerete 1:4:8, type D-2, using 40mm grade stone aggregate cement concrete as in foundation filling and mass concrete for sub base of LT poles complete all as specified and as directed.
1.89
-
-
... More
M&L for cement concerete 1:3:6, type C-2, using 20mm grade stone aggregate cement concrete as in foundation filling for base of LT poles, stay assembly complete all as specified and as directed.
23.82
-
-
... More
M&L for cement concerete 1:2:4, type B-1, using 12.5mm grade stone aggregate cement concrete as in coping of LT poles complete all as specified and as directed.
3.36
-
-
... More
Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr in depth (7 cm) for LT poles and stay and getting out soil in soft/loose soil complete all as specified and as directed.
19.5
-
-
... More
Removing excavated material n.exc. 50 mtr and depositing where directed in a level n.exc. 1.5 mtr above the starting point of any type of soil complete all as specified and as directed.
19.5
-
-
... More
Supply, laying and spreading pea gravel of nominal size 10mm dia as in replacement complete all as specified and as directed.
5
-
-
... More
S&F decorative LED type post top lanterns luminaire(Warm white light) 60 watts, out door type for 360 degree indirect light with resistant to corrosion, glare free having better uniformity complete with suitable driver complete all as specified and as directed.
6
-
-
... More
S&F decorative LED type post top(Cool Day white light) lanterns luminaire 60 watts, out door type for 360 degree indirect light with resistant to corrosion, glare free having better uniformity complete with suitable driver complete all as specified and as directed.
5
-
-
... More
S&F LED bollard luminaire 10 watts, inverted pyramid tripod type with soft 360 degree light out door type having resistant to corrosion with better optics for uniform distribution complete with suitable driver & fixing nuts, bolts & washers complete all as specified and as directed.
30
-
-
... More
S&F LED flood light luminaires 100 watts, 230 volts AC, out door type with pressure die cast housing resistant to impact and corrosion, glare free complete with lamp, driver complete all as specified and as directed.
20
-
-
... More
S&F LED flood light luminaires 50 watts, 230 volts AC, out door type with pressure die cast housing resistant to impact and corrosion, glare free complete with lamp, driver complete all as specified and as directed.
20
-
-
... More
S&F LED flood light luminaires 70 watts, 230 volts AC, out door type with pressure die cast housing resistant to impact and corrosion, glare free complete with lamp, driver complete all as specified and as directed.
20
-
-
... More
Notes :- (i) The contract sum shall be after deducting the amount of Credit shown in Sch of Credit of this Tender.
(ii) If any item of same description in nature is found to be entered as "double in BOQ" and the bidder quotes different rates against same item, then the rate quoted on lower side shall be applicable and higher rate will not be allowed to be paid in any circumstances. No claim on this account shall be entertained on a later date.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%