Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date26 Nov 2024
Closing Date7 Jan 2025
Tender Amount₹ 7,18,00,000
Costs
EMD
₹ 6,84,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_660757_2Tender No
AF_TKD_801232Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Blank
-
-
-
... More
Blank
-
-
-
... More
Blank
-
-
-
... More
Blank
-
-
-
... More
Blank
-
-
-
... More
Blank
-
-
-
... More
Blank
-
-
-
... More
Blank
-
-
-
... More
Blank
-
-
-
... More
Blank
-
-
-
... More
SCH 'A' PART XIV (MISC B/R & E/M ITEMS) Note:- Excavation and earthwork to the extent required for execution of relevant item under this schedule unless otherwise specified shall be measured and paid under relevant items of Schedule 'A' Part-II.
-
-
-
... More
INTERNAL WATER SUPPLY
-
-
-
... More
Supply and fixing angle valve of cast copper alloy chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions and fixed 15mm bore (concealed) , complete all as specified and as directed.
6
-
-
... More
Supply and fixing PVC connections 15mm ,450mm long with CP nuts , complete all as specified and as directed.
12
-
-
... More
Supply and fixing Urinal spreader of CP any colour for fixing with 15mm dia pipe , complete all as specified and as directed.
6
-
-
... More
INTERNAL ELECTRIFICATION
-
-
-
... More
Supply and fixing for Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 10 W (1000 Lumens) output, 5700 K of cool /warm white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
10
-
-
... More
Material and labour of Sheet metal enclosure MCCB DBs, Triple pole & neutral 4 way with 200 Amp rated bus bar double door suitable for 01 No incoming MCCB of 100 Amp capacity ,complete all as specified and as directed.
1
-
-
... More
Supply & Fixing 40 Amps,415 V ,TPN industrial type ,socket outlet with 4 Pole & Earth ,metal enclosed plug top alongwith 40 Amps ‘C’ Curve TPN MCB in sheet metal enclosure on surface or in recess with chained mtal cover for the socket outlet & complete connections ,testing & commissioning.
2
-
-
... More
Supply & Fixing 32 Amps,240 V ,SPN industrial type ,socket outlet with 4 Pole & Earth ,metal enclosed plug top alongwith 32 Amps ‘C’ Curve SPN MCB in sheet metal enclosure on surface or in recess with chained mtal cover for the socket outlet & complete connections ,testing & commissioning
2
-
-
... More
Supply and fixing for Exhaust fan,steel body AC Single phase 230 V of size 230 mm sweep with blades ,and frame and louvers complete all as specified and as directed .
10
-
-
... More
Supply and fixing Residual current Circuit breaker with overload current (RCBO) 100 Amp 4 pole , 415 volts having a sensetivity of upto 300 milli Amps in MCCB DB complete with connections , testing & commissioning etc , complete all as specified and as directed.
1
-
-
... More
Supply and fixing Prewired vertical type TPN MCCB Distribution Board 04 WAY Double door for 415 volts on surface/recess complete with loose wire box of sheet steel, dust protected, duly powder painted inclusive of 200 Amps tinned copper bus,comman neutral link, earth bar , din bar for mounting MCCB's terminal connectors for all incoming and outgoing duly prewired with adequate size of FRLS PVC insulated copper conductors upto the terminal connector, neutral link, earthing etc complete all as specified and as directed.
3
-
-
... More
Material and labour for Sub main wiring with Three single core FRLS,PVC Insulated ,stranded unsheathed cable FRLS copper conductor of size 25 Sqmm & drawing through & including Non metallic PVC Conduit of dia not less than 25 mm concealed in wall including Earth continuity Conductor of size 25 Sqmm PVC insulated unsheathed stranded copper conductor cable & connected to earth dolly to be drawn in concealed PVC Conduit including connecting to TPN DB complete all as specified and directed.
Note :Three Runs of 25 Sqmm wire and one run of PVC Concealed conduit shall be measured as one run only.
10
-
-
... More
EXTERNAL WATER SUPPLY
-
-
-
... More
M & L for Shifting and replacement of GI Pipe line 50 mm dia Supply & Laying of jointing and testing GI tubing medium grade with all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches complete all as specified and as directed.
Note: (i) The laying and jointing of pipes are required to be carried out in short / long streches catering to specific requirements of a purticular quarter, building block or a group of blocks.) (ii) Excavation & earth work shall be measured & paid seperately.
100
-
-
... More
Material and labour for Construction of brick masonary valve pit of 600 mm x 600 mm x 600 mm ( Internal size) sizes with 3 mm thick mild steel sheet cover and angle iron frame of size 40 x 40 x 6 mm including provision of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and all as specified:
2
-
-
... More
EXTERNAL ELECTRIFICATION
-
-
-
... More
Material and labour for complete drilling hole under hard standing /road for laying of pipe for protection of cable etc by manual booklet without disturbing the top surface and making good the disturbed surface if any complete all as specified.
53
-
-
... More
Material and labour for Cable route indicater shown "HT U/G cable" and root of cable with aero, made of CI in suitable eliptical shape and fixed in MS rod 12 mm dia 70 cm long (all word embosed) and embaded duly painted in approved colour for letter on both side in PCC block of size 30 x 30 x 60 cm in ground complete all as specified and as directed.
NOTE:-
(i)Rate quoted shall be deemed to be included for Excavation and Earthwork required at Site.
(ii) Cable Route marker shall be embedded in Cement Concrete PCC (1:2:4) of Size 60cm x60cm.The Rates Quoted deemed to include the cost of the same.
10
-
-
... More
Supply and fixing for Cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material shrink type suitable for 3.5/4 Core XLPE armoured ,AL Conductor cable of size 120 Sqmm outdoor,complete all as specified and as directed.
4
-
-
... More
Supply and fixing for Cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material shrink type suitable for 3.5/4 Core XLPE armoured ,AL Conductor cable of size 185 Sqmm outdoor,complete all as specified and as directed.
4
-
-
... More
Supply and fixing for factory made vermin proof LT panel indoor cubical type of suitable size made out of 2 mm thick MS Sheet and MS angle section 50x50x6mm on PCC 1:2:4 type B-1, plateform 60 CM above the ground level and 45 CM below the ground level, factory fabricated with front and back openable double door system with and lock openable by keys having chromium plated 19 mm dia fancy lock and 01 No Navtal lock for main door louvers and air vent, gasket ‘U’ type for natural flow of air, complete dust and vermin proof suitable for 3 phase 4 wire 415 volt 50 Hz factory made (Factory approved from CPRI) having modern fabrication followed by powder coated painting including making connections with aluminium strip conductor and general construction confirming to IS -8623 of 1993 comprising of the following: (a) Aluminum bus bar 600 Amps cap 4 wire fixed on insulator not less than 1.0 mtr long bus bar -1 set (b) MCCB , 4 pole 400 amps, Icu=100%Ics, having microprocessor based release for over current,short circuit & earth fault with display and fault discrimination 35 kA -01 (INCOMING) (c) -ditto- but MCCB ,4 pole 315 amps, 35 ka -01 (For connection to DG SET )
1
-
-
... More
Above item contd...
(e) -ditto- but MCCB, 4 pole , 63 amps, 25 ka-01(street light) (f) Voltmeter digital type 0-500 volts with inbuilt selector switch-01 Nos. (g) Ammeter 0-500 amps, with CT, and inbuilt selector switch -01 Nos (h) Indicting lamps LED type (R,Y,B) -01 Set (k) Three phase energy meter digital type of range 300 amps including CT
-
-
-
... More
Supplying, Installing, Commissioning and Testing in repairs of CPRI Prototype tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proof LT Cubical Panel Board, Compartmentalised, Indoor type, fabricated with 2mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist of 400 Amps rating TPN bus bars of high conductivity Copper Alloy and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size, including instrumentation such as Ampere Meter, Volt Meter, Phase Indicating LED Lamps [RYB], Selector Switches etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts Grade, 3 Phase, 415 Volts, 4 Wire, 50 Hz, AC Supply and to withstand short circuit fault level of not less than 100KA and degree of protection shall be IP 54. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables etc. and comprising the following:-
1
-
-
... More
Above item contd...
i) MCCB 315 Amp 4Pole 35 KA-01 No(Incoming from main panel )
ii)MCCB 100 Amp 4 Pole 25 KA-04(3 Working+1 Standby) as outgoing
iii) Indicator Lamp set-01 No (R Y B)
(iv)Digital Voltmeter (0-500 V)-01 No
(v)Digital Ammeter(0-100 Amp)-01 No
-
-
-
... More
Supply and fixing for non transparent looping SMC kiosks pole box 3 phase of size 310 x 210 x 120 mm made out of engineering plastic one piece moulding Siemens grey colour with hold fast including 4 Nos of aluminium strips 60 amp of required size fixed on unbreakable insulator and one No of single pole MCB 1 to 6 Amp, C curve including taking out of old unserviceable complete all as specified and as directed.
2
-
-
... More
Supply and Erection of 11 KV Pin Insulator complete with large steel head GI Pin,Nuts washers etc as required complete all as specified.
6
-
-
... More
Supply and fixing for GI Pipe Medium Grade 100 mm dia along the Pole with GI fittings including trenching 75 cm deep and Re-filling as required complete all as specified.
14
-
-
... More
Supply and fixing for Three piece non-linear resistor lightening arrestor suitable for 3 wire ,11 KV overhead lines with rated voltage 9 KV(RMS) with a nominal discharge current rating of 5KA complete with galvanised clamping arrangement GI Bolts,nuts & washers etc complete all as specified and as directed.
2
-
-
... More
AREA DRAINAGE
-
-
-
... More
Material and labour for Pre cast perforated RCC drain cover with frame (rectangular or square) the area of each cover of any size any shape and thickness of 60mm each with holes manufactured with M-30 grade of concrete by Vibro Compaction process using accurately designed molds and as suitable reinforced to enable the covers to take load as specified i.e. 20 MT for heavy duty (when tested as per IS 12592), complete all as specified and as directed.
150
-
-
... More
LIGHTINING PROTECTION
-
-
-
... More
Supply and Fix epoxy insulator duly coloured with necessary fixing arrangement on wall and roof for fixing of down conductor complete all as specified and as directed
150
-
-
... More
FIRE FIGHTINING AND FIRE ALARM SYSTEM
-
-
-
... More
Supply & Fixing of fire survival control cable cable size 1.5 sqmm, 2core, multistranded copper conductor twisted pair, sheathed, FRLS, PVC insulated cable, 650V, as per IS 1554 passing through steel enameled conduit and complete all as directed.
Note:-
Steel conduit required will be paid separately under respective item of the schedule.
400
-
-
... More
Supply, Installation, Testing and Commissioning 4.5 kg capacity CO2 type ISI marked confirming to (IS15683:2006) fire extinguisher complete with delivery hose horn, release valve, locking arrangement, operation manual, bracket complete all as specified and directed. ,complete all as specified and as directed.
12
-
-
... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 0.5 KVA.Make:V Guard VG-400 ,complete all as specified and as directed.
1
-
-
... More
M&L complete for earthling with galvanized mild steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground ( in vertical position ) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5mtr (B.G.L.) and connected to 4MM GI Wire by means of bolts, nuts, check nuts and washer of galvanized iron including PCC(1:2:4) type B1 precast RCC cover slab with suitable handle made of 12mm round bar, including necessary excavation &earth work in any type of soil. 20mm dia med gde galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mmdia bore, light grade galvanized steel tubing up to 7.5 mtr length for drawing earth lead wire protection common salt, charcoal etc complete all as shown in EP No 3 of SSR Part 1 and testing on completion.,complete all as specified and as directed.
8
-
-
... More
ROAD
-
-
-
... More
Material and labour for Preparation of road surfaces and applying thermoplastic reflective paint in making of minimum 2.00mm thick single coat as in centre line and edge line road marking of 150/100mm width using 'HOT MARK' thermoplastic paint (Hot application) white/yellow by indigenious modern rolled road marking machine as directed including all ingredients such as binder ,glass beads, titanium dioxide calcium carbonate inter filler thermoplastic requirement for glass shall be the table No. 800.4 of MORTH specification including spraying of glass beads etc all as per manufacturer instructionn and as directed.
150
-
-
... More
Supply and fixing for solar cat eye (stud ) made of aluminium dicasted body,. 100% waterproof , both side reflectors, designed according to IP 65 of size 12.5mm X 125mm X 25mm with shank not less than 60mm length, high efficiency mono crystaline solar panel (2.5V/0.3V), one Ni-Mh or Ni-cd rechargeble battery (1.2V/1600MA) having 6 super bright LEDs with 10000 to 18000 mcd (milicandela), view distance upto1000 metre and flush road bearing capacity 10 MT , fixing in road by drilling a hole and with epoxy hardner etc as per manufacturer's instructions at the locations complete all as specified and as directed.
30
-
-
... More
Supply and fixing for road safety convex mirror of polycarbonate mirror of dia 600mm fitted on 50 mm dia powder coated MS pipe min length 2.00 Mtr and fixed with PCC 1:2:4 in foundations , complete all as specified and as directed.
4
-
-
... More
DG SET
-
-
-
... More
Supply,.Install,testing and Commissioning of Outdoor Type 200 KVA Diesel Generating Set consisting of Engine,alternator(coupled together)AMF Panel 415 Volts ,50 Hz,04 Wire 0.8 PF with acoustic enclosure conforming to CPCB norms on a common base frame except AMF Panel and all connected items etc with following specification:-
(a)ALTERNATOR:Standard design alternator rated at 200 KVA/160 KW net output at site as per site condition confirming to latest IS:4722 at power factor 0.8,AC 3 phase 4 Wire ,415 Volts 50 Cycles 1500 RPM,self excited,self regulated through an AVR screen protected,drip proof IP 23 enclosure brushless design ,winding in each pole faces insulating class ‘H’ Plus/minus 1.5% voltage regulation (max) in static conditions including permanent lubricated sealed bearing .The alternator shall in position to generate supply with frequency regulation with in plus/minus 1% tolerance and permissible overload of 10% of operation.The alternator shall be confirming to BS 2613/5000/IS latest IS:13364 andthe alternator shall generally confirm to BS-2613/5000/IS-4722 (b)DIESEL ENGINE -Diesel Engine of engine electric start,water cooled,1500 RPM and suitable to drive above alternator independently.Engine directly coupled with above alternator by flexible coupling .
1
-
-
... More
above item contd..
Engine shall be 10001/10002/5514with an overload capacity of 10% complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under
(i)Batteries of Capacity as recommended by Manufacturers complete with initial Charging.
ii)Exhaust System:-Silencer complete with exhaust piping of suitable size adequate for safe exhaust along with turbocharger,flexiblebellow,companion flanges complete.
(iii) Engine Protection devices include audio,indicators and cut off system during following instances:- (a) Low Lubricating Oil Pressure (b) High Coolant Temperature (c) Over Speeding of Engine (d) Battery Charging Indicator iv) Fuel Tank with locking arrangements of storage capacity not less than 12 hrs continuous run at full load with level indicating arrangements,stopcock,drain plug and fuel supply GI piping from tank to pump including return of over flow.
(v) DC Electric starter and DC battery charging alternator as per OEM Rating
vi) Engine Instrument Panel consist of Start Switch ,electricLub Oil pressure gauge,Electric water Temperature gauge,electric hour meter ,Battery Charging Indicator,Bell failure indication and Magnetic Pick up fail indication etc. (vii)Suitable base Frame for Mounting complete unit of Engine and Alternator with anti vibration pads. (viii) Air intake System shall be air intake manifold and dry type air cleaner.
-
-
-
... More
above item contd...
(c)AMF Panel:AMF Panel board indoor type for 200 KVA DG Set made out of CRCA sheet of 2 mm thick totally enclosed,weather ,dust and vermin proof with front and rear opening rated voltage 440 volts,3 phase ,4 wire 50 Cycles having 04 strip aluminium bus bar of capacity 1.5 times the full load current of alternator,duly colour coded with coloured heat shrinkable PVC Sleeves suitable on load changeover for bypass arrangement of main supply and DG Supply including two coats of finishing grey paint over one coat of primer red oxide suitable for and including frequency meter ,volt meters and amp meters with selector switches along with following controls and components:-
(i)CONTROLS:-Contactor ON indication ,Contactor OFF Indication,Engine Start push button.
(ii)BREAKER:-Two NO’s ,Electrically operated contactor 3 pole of suitable capacity for DG set and Main Supply Complete.
(iii)BATTERY CHARGER:Battery Charger consist of Transformer ,rectifier,DC Voltmeter,Amp Meter ,float/boost charging facility range selector switch etc. (iv)RELAYS:-One set of Microprocessor based Relay for AMF logic.
(v) By Pass Arrangement:-One on load change over switch suitable capacity of DG set main supply and by pass arrangement for Main,DG Sets.
(d)FOUNDATION:Suitable size of Foundation not less than 45 cm height above ground level as per the design and direction of manufacturer to Installed DG set.Excavation ,Earth work ,PCC and Brick work etc shall be included in the quoted rate.
-
-
-
... More
15.24A S&F On Load Change over switch 415 Volts in Sheet Metal Enclosure 4 Pole of Capacity 300 Amp complete all as specified and directed
1
-
-
... More
AIR CONDITIONING
-
-
-
... More
Supply, install ,commissioning and testing Voltage stabilizer of capacity 5 KVA for automatic operation,Single phase,naturally air cooled ,indoor type ,designed for input variation between 170 V to 250V and with output voltage stabilsed at 230 Volt with accuracy of +-2.5% and connecting up all as per manufacturer's instrucions with mounting bracket complete with time delay relay for 1.5 Ton Air conditioner complete all as specified and directed.
Note:Contractor shall submit necessary submit necessary company test certificate and purchase voucher omplete all as specified and directed.
3
-
-
... More
Supply and fix Canvass connection fire retardant (1 No per machine) complete all as specified and as diectred.
6
-
-
... More
Supply and Fixing for Copper refrigerant piping for Package split units duly insulated with nitrile tube and supported (10 RM per Circuit), complete all as specified and as directed.
200
-
-
... More
Supply,Installation,testing and Commissioning of Air Aluminium grill with Aluminium Damper,complete all as specified and as directed.
6
-
-
... More
Supply,Installation,testing and Commissioning of Air Aluminium grill without Aluminium Damper,complete all as specified and as directed.
12
-
-
... More
Supply,Installation,testing and Commissioning of Air Aluminium Diffuser with Aluminium Damper,complete all as specified and as directed.
2
-
-
... More
Supply,Installation,testing and Commissioning of Air Aluminium Diffuser without Aluminium Damper,complete all as specified and as directed.
4
-
-
... More
Supply,installation,testing and commissioning Nitrile Rubber Insulation 13 mm thick,complete all as specified and as directed.
300
-
-
... More
Supply,installation,testing and Commissioning of accoustic armasound insulation 10 mm ,complete all as specified and as directed.
120
-
-
... More
15.33A:Supply,Installation & Testing One No Temper Proof Electronic Digital Thermometer ,Hygrometer with recording & display facility fixed at Plant Room from Relative Humidity & Return Air Temp Sensor with necessary fixing arrangement complete all as specified and as directed.
2
-
-
... More
LIFT
-
-
-
... More
Designing,Supply,Installation,Erection ,testing and commissioning of Goods Lift 3000 Kg Capacity 0.5 m/s (Car Dimensions 2 m Width x3 m x2.3 m High) Bldg With Synchronous axial motor 415 V, 3 phase AC 50 Hz supply conforming to IS- 14665, suitable to serve G+02 upper floors with AC V3F drive complete with all standard accessories, simplex automatic & neutral duel controlled operation with/without attendant , entry through centre opening power doors with door drive (electric motor driven mechanism) sliding stainless steel hair line finish doors. Automatic rescue drive (ARD) system, 3D infrared door sensor in full height of door & built in announcing system without handset (04) Nos, one each in car & near ground floor landing door all as specified. Braile buttons to be integrated in COP and surface mounted LOP. complete all as specified including accessories ,necessary equipment and testing from inspector of lift. Delhi. (a) Designation of lifts-Goods Lift
(b) No.of Elevators - 01 (c) Type of capacity - 3000 Kg (d) Speed: 0.5 M/Sec.
(e) Drive: Variable Voltage Variable Frequency (VVVF) Drive.
1
-
-
... More
above item contd...
(f) Operation: Micro-processor based Simplex Collective Selective Control with provision of AUTO. attendant control.
(g) Location of Machine Room : Above lift well (h) Total Travel: 14 Metres (approx) (i) Serving - Floor Designation will be 0,1,2
(j) Required well size 2900mmx3300mm
(k) Power Supply 415 V 3 phase 50 Cycles AC (l) Auxiliary Single Phase 220V 50cycles AC (m) Car Size: About 2000 mm (W) x 3000 mm (D) x 2300 mm (H) up to Suspended Ceiling.
(n) Stops & Opening: 03 Stops & 03 Openings. (o) pit depth 1350 mm (p) Head Room 4500mm Car enclousre :-
(a) Car ceiling - CL 88 Silver Mirror Polish Stainless Steel (b) Car Panel- Mid Panel : - Silver Mirror Polish Stainless Steel, Side Panel - Laminated - Macassar (c) Model -N-MONOSPACE-EXTENTIA-33023P2Z (d) Car Flooring -White Stone .
(e) Car Illumination: Round LED Spot Lights & Fan as per standard design.
(f) Car Entrance : Centre opening power Door With Full glass in Stainless Steel Hairline Finish with Variable Voltage Variable Frequency (VVVF) door drive
(g) Clear Openings: About 2000 mm (W) x 2000 mm (H).
(h) Control - Selective collective Simplex. Indicators (a) Car : KDS 300 Full height Silver Mirror Polish Stainless Steel Face plate with round flush Mounted white button
(b) KDS 300 White ,Dot Matrix Display Silver Mirror Polish Stainless Steel on Lintel Flush Mounted.
(c) Other Features : Emergency Light and alarm, Emergency stop button with rechargable battery 2 phase, Fireman drive Auto. Circuit Light & cross flow pan, Door Open and Close Button, Auto-Attendant Switch, Overload device, Inbuilt Automatic Rescue Device, Infra-Red Curtain 128 beams, single phase sensing device.
-
-
-
... More
above item contd...
(d) 02 Nos Earthing connections of the machine drive motor and control panel shall beprovided from near by earth dolly complete with suitable size copper strip.
(e) Grouting suitable size MS ISMB, bolts & plates etc on existing RCC/PCC foundation all as directed complete as per manufacturer's design / requirement.
(f) Provision of hoist way and Governor Rope with Governor.
(g) Provision of New buffer springs for car as well as counter weight as per manufacture's design.
(h) Battery operated alarm bell and emergency light.
(i) Steel Wire Rope as per IS: 14665 Requirement.
(j) Provision of travelling cables with copper conductor with suitable size GI/PVC through and other accessories complete.
(k) Provision of any other components not considered in this schedule but required at the time of execution for smooth functioning of the lifts as a whole.
(l) Car ceiling - CL88 silver mirror polish stainless steel.
(m) Handrail - HR61 round tubular with straight ends alongwith silver mirror polish stainless steel finish.
Safety measures as per manufacturer's design:
(i) Over load relays and warning device.
(ii) Contacts and fuses of suitable size and capacity.
(iii) Electrical terminals, of suitable size and capacity.
(iv) Limit switch with accessories on each door /cage.
(v) Gravity /counter weight limit switches for top most position.
(vi) Electro magnetic brake of suitable size with manned released arrangement.
-
-
-
... More
above item contd...
(vii) Phase sequence corrector & single phase preventer.
(viii) Painting work with super enameled synthetic pain to all the exposed surfaces all as directed by GE/Engineer-in-Charge.
(ix) Provision of necessary electrical wiring of lift well / shaft with FRLS copper cable multistranded 1.5 sq mm, LT 1100 Volts grade for minimum 5 points including bulk head luminary LED 12 watt. Make : Bajaj / Philips / Crompton Greaves.
(x) One inspection lamp and one power socket 5/15 Amps on top of car.
(xi) Display of wiring diagram of lift control panel.
Note :-
(i) "Press & Speak" system to be connected with lift (ii) Intercom in the cabin & machine room shall be connected with existing communication network as desired.
(iii) Dos & Don'ts chart on steel plates have to be installed inside car cabin.
(iv) Contractors must check the details and dimensions at site before quoting the rates. The lift car door opening and landing door opening must be aligned with lift well opening so that maximum lift well opening is available at each floor. No addition/alteration to existing RCC columns will be permitted to provide neccessary lift car/landing gate opening.
(v) 415 Volts 3 Phase 50 Hz, AC supply shall be made available by MES and the contractor has to make necessary connections to the lift panel board.
(vi) The rate quoted by the contractor is deemed to be inclusive of preventive and periodical maintenance for 02 years after completion of work as per the manufacturer's guide lines.
-
-
-
... More
above item contd...
(vii) Provide of Automatic Rescue Device (ARD) by providing UPS of adequate capacity with SMF battery(s) having a power back up for minimum 30 minute stop at the car a get at the nearest floor level for auto opening of door & for ejaculation of passenger & to operate car cabin fan, carlights, emergency lights, and alarm bell and intercom in the event of electric break down all as directed by GE/Engineer-in-Charge.
(viii) Provn of voltage fluctuation with standing capacity to new microprocessor controller to safe guard the electric circuit and to enable smooth functioning of the light in case of voltage fluctuation in the system.
(ix) Provision of safety guard equipments such as two Nos pit switches controller guarding pit pulley, guarding pit ladders, fascia plates to cover free space between car cabin and hoist way & switches.
-
-
-
... More
REVISION OF CMD
-
-
-
... More
Deposit with BSES for additional /Revised CMD 200 KVA ,complete all as specified and as directed.
200
-
-
... More
Total amount of Schedule 'A' Part XIV carried over to General Summary
-
-
-
... More
Blank
-
-
-
... More
Blank
-
-
-
... More
GENERAL SUMMARY
-
-
-
... More
Lumpsum price worked out by the contractor for "BUILDING AND STRUCTURES" as listed in Sch ‘A' Part I representing above / below the lumpsum price as inserted by MES for Sch ‘A’ Part I on Srl Page No.31
1
49971668
-
... More
Lumpsum price worked out by the contractor for “SITE CLEARRANCE, EXCAVATION AND EARTHWORK" as listed in Sch ‘A” Part II representing above / below the lumpsum price as inserted by MES for Sch ‘A’ Part II on Srl Page No.32
1
628646
-
... More
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY” as listed in Sch ‘A” Part III representing above/below the lumpsum price as inserted by MES for Sch ‘A’ part III on Srl Page No. 33
1
19230
-
... More
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION” as listed in Sch ‘A” Part IV representing above/below the lumpsum price as inserted by MES for Sch ‘A’ part IV on Srl Page No.36
1
1278920
-
... More
Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Sch ‘A” Part V representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part V on Srl Page No.37
1
98791
-
... More
Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIFICATION" as listed in Sch ‘A” Part VI representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part VI on Srl Page No.42
1
3172489
-
... More
Lumpsum price worked out by the contractor for “ROAD/PATH"' as listed in Sch ‘A” Part VII representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part VII on Srl Page No. 44
1
2256691
-
... More
Lumpsum price worked out by the contractor for “ SEWAGE DISPOSAL” as listed in Sch ‘A” Part VIII representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part VIII on Srl Page No. 46
1
429502
-
... More
Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Sch ‘A” Part IX representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part IX on Srl Page No. 47
1
1021710
-
... More
Lumpsum price worked out by the contractor for “LIGHTENING PROTECTION” as listed in Sch ‘A” Part X representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part X on Srl Page No. 48
1
330688
-
... More
Lumpsum price worked out by the contractor for "DG SET ” as listed in Sch ‘A” Part XI representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part XI on Srl Page No. 49
1
42985
-
... More
Lumpsum price worked out by the contractor for “FIRE FIGHTING /FIRE ALARM SYSTEM ”as listed in Sch ‘A” Part XII representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part XII on Srl Page No. 50
1
239117
-
... More
Lumpsum price worked out by the contractor for “AIR CONDITIONING ”as listed in Sch ‘A” Part XIII representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part XIII on Srl Page No. 52
1
4436519
-
... More
Total amount of SCHEDULE 'A' PART XIV (MISC B/R & E/M ITEMS) brought forwarded from Serial Page No. 68
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%