If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 44,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681772_1Tender No
GE/SP/TOKEN-64/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L for Sand cushioning of cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable complete all as specified and directed by engineer-in-charge.
112
-
-
Supply and laying well burnt sub class ‘B’ bricks old size as mechanical protection to under ground cables laying across the cable complete all as specified and directed by engineer-in-charge.
12
-
-
M&L for precast cement concrete block masonry with solid blocks,exceeding 10 cm in width and setting in mortar type B-1, 1:2:4 (using 20 mm graded stone aggregate) complete all as specified and directed by engineer-in-charge.
0.3
-
-
Material and labour for cutting of road/ hard standing up to a size not exceeding 20cm width and not exceeding 60cm in depth for laying of cable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 and block top with black bituminous upto existing surface level complete all as specified and as directed by Engineer-in-charge.
12
-
-
Supply and laying as in repair 80mm bore GI pipe light grade galvanized with all fittings laid in trenches or fix on wall for cable protection complete all as specified and directed by engineer-in-charge.
20
-
-
All as per srl item No 08 here in before but size 50 mm bore
20
-
-
Disconnecting,removing & taking out faulty U/G cable off sizes from trenches,wall and ducts complete all as specified and directed
1749
-
-
Supply, Laying, Testing and connecting cable XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade cross section area of 300 sqmm x 3.5 core complete all as specified and directed
90
-
-
All as per srl item No 11 here in before but size 185 Sq mm x 3.5 core
100
-
-
All as per srl item No 11 here in before but size 120 Sq mm x 3.5 core
110
-
-
All as per srl item No 11 here in before but size 95 Sq mm x 3.5 core
100
-
-
All as per srl item No 11 here in before but size 70 Sq mm x 3.5 core
150
-
-
All as per srl item No 11 here in before but size 50 Sq mm x 3.5 core
220
-
-
All as per srl item No 11 here in before but size 35 Sq mm x 3.5 core
284
-
-
All as per srl item No 11 here in before but size 16 Sq mm x 4 core
245
-
-
All as per srl item No 11 here in before but size 10 Sq mm x 2 core
150
-
-
All as per srl item No 11 here in before but of size 400 sq mm x 3.5 core
300
-
-
Supply and fixing in replacement of aluminium thimble stud type suitable for size of cable 240 to 400 sq mm complete all as specified and directed by engineer-in-charge.
60
-
-
Supply and fixing in replacement of aluminium thimble stud type suitable for size of cable 16 to 180 sq mm complete all as specified and directed by engineer-in-charge.
60
-
-
M & L in replacement FRP juction box including MCBs with front cover fixed with locking arrangement with suitable clamp/fixture on pole complete all as specified and directed by Engineer-in-Charge.
25
-
-
Material and labour for cleaning of Electric panel at rusted portion with sand paper and painting with synthetic enamel paint suaitable for metal complete all as specified and as directed by Engineer-in-Charge
10
-
-
Supply & fix in replacement PVC insulated Aluminium conductor twin core service cable ISI marked of size 6 Sqmm complete all as specified & directed by engineer in charge
300
-
-
Supply & fix in replacement PVC insulated Aluminium conductor twin core service cable ISI marked of size 10 Sqmm complete all as specified and as directed by Engr-in-Charge.
200
-
-
M&L for Preparation of old painted surface of steel tubular swaged poles (9 to 11 meter long) with good neck brackets including junction box, GI pipe and light fittings i.e HPSV/HPMV any rating and painting with one coat of aluminium paint including cleaning the acrylic cover and painting with black to 1.5 mtr height from top of PCC coping and marking pole numbers with one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge
10
-
-
M&L as in repair earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to galvanized earth lead wire 4 mm dia by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-1 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
10
-
-
All as per item No 28 here in before but using galvanised iron strip 25x4mm as earthhing lead
10
-
-
M&Las in repair for 4mm dia GI wire complete all as specified and directed
20
-
-
Material and labour as in repair for galvanised iron strip 25 X 4 mm with saddles and fixing screws and connected as per site requirement complete all as specified and as directed by Engineer-in-Charge.
20
-
-
Disconnecting to worn out cable off size from main control panel /LT over head line/UG line cutting worn out portion and reconnecting including suitable size of aluminium lugs & thimbles ,nuts, bolts & washers complete all as specified and as directed by Engineer-in-Charge.)
Note : Excavation of necessary earth work shall be measured and paid separately.
10
-
-
S&F in replacement of ACB 800 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 36 KA complete all as specified and directed
1
-
-
S&F in replacement of MCCB 400 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 36 KA complete all as specified and directed
6
-
-
S&F in replacement of MCCB 250 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 35 KA complete all as specified and directed
6
-
-
S&F in replacement of MCCB 200 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 35 KA complete all as specified and directed
6
-
-
S&F in replacement of MCCB 160 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 35 KA.
5
-
-
Supply and fixing as in repair amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 5 To 32 AMP in the MCB DB/ junction box complete with connection testing and commissioning complete all as specified and directed
100
-
-
Supply and fix tape insulation PVC 25 mm wide in various colours of standard length complete all as specified and as directed by Engineer-in-Charge.
150
-
-
Taking down old unsv MCB DB of any size complete all as specified and directed
29
-
-
Supply and fixing in replacement load line vertical distribution board 'A' frame made out of CRCA 2mm thick mild steel sheet,double door, surface mounting TPN 8 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP 'A' frame MCCB of 125 Amps =01 No MCB for outgoing complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
9
-
-
Supply and fixing in replacement load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP 'A' frame MCCB of 125 Amps =01 No MCB for outgoing comlete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
8
-
-
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
6
-
-
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 12 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
6
-
-
Supply and fixing in replacement MCBs 10 KA breaking capacity, single pole, and neutral, 240 volts, 40 amps C Curve capacity.
60
-
-
S&F MCB TP 63 Amps 10 KA, 440 volt 50 Hz complete all as specified and directed by engineer in- charge.
10
-
-
S&F MCB TP 100 Amps 10 KA 440 volt 50 Hz complete all as specified and directed by engineer in- charge.
11
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%