Military Engineer Services Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Dec 2024
Closing Date31 Dec 2024
Tender Amount₹ 7,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking out unserviceable AHU motor and rewinding AHU blower motor 1 to 3 HP 3 phase 415 V 50 Hz installed at AFCME with copper winding wire including insulation thimbles greasing & replacement of minor spare parts such as keys, bushes etc and testing after rewinding and refixing to its existing location after rewinding complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Taking down unserviceable AHU blower of ceiling mounted AHU installed at AFCME,also taking down false ceiling and refixing the same after blower fixing complete all as specified and directed by Engg-in-charge.

2

-

-

... More
Taking down unserviceable AHU blower shaft of ceiling mounted AHU installed at AFCME, also taking down false ceiling and refixing the same after blower fixing complete all as specified and directed by Engg-in-charge.

2

-

-

... More
Supply and fix in replacement of unserviceable V belt for AHU for central AC plant of cap 1x36 TR complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
M&L to Open/dismantle the supply air duct joints from AHU section to conditioned space, disengaging the diffuser units from the duct complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
M&L to Open/dismantle the return air duct joints from conditioned space to AHU section, disengaging the diffuser units from the duct complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
M&L to clean the supply air duct from inside with the help of pull through or as required at site with chemical CTC to remove large quantity of carbon dust particles complete all as specified and directed by the Engineer-in-Charge.

1200

-

-

... More
M&L to clean the return air duct from inside with the help of pull through or as required at site with chemical CTC to remove large quantity of carbon dust particles complete all as specified and directed by the Engineer-in-Charge.

1000

-

-

... More
M&L for refrigerant charging (M-22/F-22/R-22) for central AC plant including pressure testing the complete plant by dry nitrogen gas by separating high side and low side, rectifying the leakage by gas welding brazing pressure testing vacuuming the system and re-charging the system with gas, testing and commissioning complete all as specified and directed by Engr-in Charge. Note:- Any leakage occurs after charging of gas same shall be repaired and rectified by contractor without claiming extra cost from department.

120

-

-

... More
S&F in replacement of condenser water and chilled water pipes of MS heavy grade of following sizes/dia with all fittings complete laid in trenches/on wall/on ceiling/roof etc including necessary suitable size of MS clamps/saddling on walls etc complete all as specified and directed by the Engineer-in-Charge.

-

-

-

... More
80 mm dia.

40

-

-

... More
65 mm dia.

30

-

-

... More
Supply and fix in replacement of unserviceable MCCB 200 amps 4 pole 36 KA 415 volts 50 Hz with adjustable thermal and fixed magnetic setting, (Ics=100% Icu) complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
Supply and fix in replacement of unserviceable MCCB 160 amps 4 pole 36 KA 415 volts 50 Hz with adjustable thermal and fixed magnetic setting, (Ics=100% Icu) complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
Supply and fix in replacement of unserviceable MCCB 100 amps 4 pole 25 KA 415 volts 50 Hz with adjustable thermal and fixed magnetic setting,(Ics=100% Icu) complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable MCCB 100 amps 3 pole 25KA 415 volts 50 Hz with adjustable thermal and fixed magnetic setting complete (Ics=100% Icu) all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable MCB TP 16-32A complete all as specified and directed by the Engineer-in-Charge.

3

-

-

... More
Supply and fix in replacement of unserviceable MCB TPN 63A complete all as specified and directed by the Engineer-in-Charge.

3

-

-

... More
Supply and fix in replacement of unserviceable MCB DP 63A complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
S&F in replacement of scroll compressor of cap 12.5 TR with washers, bolts and nuts three phase 415 V 50 Hz suitable for central AC plant including brazing leak test of the system with compressed nitrogen and testing the unit for satisfactory functioning complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
Charges for attending to central AC plant complaints for rectification of minor complaints in LT panel, control Panel, AHU, Compressor and condensor including replacement of minor parts like nut bolts, washer, small gasket, complete all as specified and directed by the Engineer-in-Charge.

8

-

-

... More
M&L for insulation to chilled water piping with 12 mm thick rubber nitrile with Aluminium foil of density 30 Kg/Cum for 65 mm chilled water pipe complete with rubber based adhesive Pidlite SR 998/equivalent and thermal conductivity not exceeding 0.0035 W/Mk at an average temp of 40 Degree C complete all as specified and directed by the Engineer-in-Charge.

20

-

-

... More
M&L for insulation to chilled water piping of central AC plant of following sizes with 19 mm (for all pipes) and 13 mm (for drain pipes) thick, closed cell chemically cross linked fire retardant polyethylene foam insulation of density 30 Kg/Cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C, covered with aluminium faced foil complete with application with rubber based adhesive pidilite SR 998 and 50 mm X 3 mm thick self adhesive tape on both longitudinal & transverse joints simultaneously complete all as specified and directed by the Engineer-in-Charge.

-

-

-

... More
65 mm dia chilled water pipe including valves, strainers etc.

40

-

-

... More
50 mm dia drain pipe.

35

-

-

... More
M&L for insulation to HDPE expansion tank of size 1000 Ltr of central AC Plant with suitable FR-XLPE/XPE 19 mm thick of minimum bulk density 28/-4 Kg/Cum covered with vapour barrier and finished with 0.5 mm thick aluminium cladding and application with rubber based adhesive pidilite SR 998 and 50 mm X 3 mm thick self adhesive tape on joints complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
S&F in replacement of 6 Sqmm copper Control Cable,3 core for AHU motor including connection from panel to Motor complete all as specified and directed by the Engineer-in-Charge.

45

-

-

... More
Supply and fix in replacement of Expansion Valve capacity of 12.5 TR installed at AFCME central AC plant including welding/brazing and checking of leaking and leak arrest complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
M&L for repair to unserviceable PCB board suitable for central AC plant installed at AFCME of compressor 3x12.5 TR capacity by means of re-programming of PCB as per existing software complete and testing for proper working of PCB complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
M&L in repair of cross arms bracings supports, clamps and back plates fabricated from structural steel sections including nuts bolts washers welding bending cold or hold drilled holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under and one finished coat of paint for installation of make up water tank complete all as specified and directed by the Engineer-in-Charge.

80

-

-

... More
M&L for taking out unserviceable condensor fan motor and rewinding of motor for air cooled central ac plant at AFCME with super enamelled copper winding wire and replacement of bearing and minor spare parts like as keys, bushes etc and testing after rewinding and refixing to its existing location after rewinding complete all as specified and directed by the Engineer-in-Charge.

1

-

-

... More
Supply and fix in replacement of unserviceable water pressure gauge 0-150 PSI 4" dia dial type complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable Thermometer industrial type complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of unserviceable oil pressure gauge 0 to 150 PSI of dia 4" complete all as specified and directed by the Engineer-in-Charge.

2

-

-

... More
S&F in replacement of 10 Sqmm copper Control Cable , 4 core for compressor connection from panel to Motor complete all as specified and directed by the Engineer-in-Charge.

90

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.