Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 29,420Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_685727_1Tender No
GE/H-59/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Taking down cement plaster of any description on brick or stone masonry wall, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed by Engr-in-Charge.
180
-
-
... More
M&L for rendering 15 mm thick in cement and sand mortar 1:4 on brick work or cement concrete surfaces of walls including finishing the surface even and fair, complete all as specified & directed by Engr-in-Charge.
180
-
-
... More
M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior grade weather proof paint over a coat of primer & 1 to 2mm thick cement base wall care putty, complete all as specified & directed by Engr-in-Charge.
180
-
-
... More
M&L for complete removal of existing treatment from external surfaces of walls by electrically operated grinder, washing and filling of holes with filler material and applying 1-2mm thick cement base wall care putty on the whole surface to achieve smooth, even & uniform surface including grinding with sand paper and levelling of surface and applying two coats of exterior grade weather proof paint over one coat of primer, complete all as specified & directed by Engr-in-Charge.
50
-
-
... More
Demolition of cement concrete (any description and in any position not otherwise specifically provided for, complete all as specified & directed by Engr-in-Charge.
2
-
-
... More
M&L for cement concrete 1:2:4, type B-1 (using 20mm graded aggregates), as in copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified & directed by Engr-in-Charge.
2
-
-
... More
M&L for precast cement concrete 1:2:4 type B-0 (using 12.5mm graded aggregates), as in louvres and jallies, 25mm thick (measured solid), set in cement mortar 1:4 including all mouldings and including demolition of old RCC jali, complete all as specified & directed by Engr-in-Charge.
10
-
-
... More
S & F in replacement of LED 18 Watt Outdoor UP Down Wall Light Warm White, IP-65 Rainproof & Shockproof Alluminium Body (4 Way Splitter)(Metal) PF0.9 and operated Voltage rated 220V to 240V complete all as specified & directed by Engr-in-Charge.
107
-
-
... More
Taking down unserviceable sub main wiring of aluminium any type with earth wire and making good disturbed surfaces of wall/ floor or roof etc and applying putty complete all as specified & directed by Engr-in-Charge.
550
-
-
... More
Material and labour for Sub main wiring with 2 run of 2.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit with wall thickness 1.6mm thick and including 2.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB complete all as specified & directed by Engr-in-Charge.
Note : 1. The two run of 2.5 Sqmm wire, one run of 2.5 Sqmm wire and 1 mtr PVC conduit pipe will be measured as one unit.
2. Cutting chases required for sub main wiring shall be finished with cement mortar 1:4 and surface shall be matched with existing shade of surface shall be deemed to be included in the unit rate quoted by the contractor.
550
-
-
... More
S & F in replacement MCB, SP, 6 to 32 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified & directed by Engr-in-Charge.
15
-
-
... More
S & F in replacement MCB, SPN, 32 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified & directed by Engr-in-Charge.
3
-
-
... More
Supply & fixing in replacement of street light timer panel with Nature switch single phase 25 Amp rating with all accessories like sensor, contactor, MCB, voltage monitoring system etc which automatically switch ON at sunset and automatically switch OFF at sunrise and enclosed in SMC enclosure dust and water proof complete incl fixing by making proper foundation with angle iron frame or fixed on pole/ on wall all as directed by Engr -in-charge.
1
-
-
... More
S & F in replacement Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, flush /mounting on wall, SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as specified & directed by Engr-in-Charge.
3
-
-
... More
M & L Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all by means of nuts and bolt check nuts and washers of galvanised iron sheet all as shown in electrical plate Nos 5 of SSR Part - I and connected to and including earthing test point complete including testing filling of adequate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil up to 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made but at 6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified & directed by Engr-in-Charge.
1
-
-
... More
S&L, testing and jointing XLPE insulated, screened, PVC bedded, galvanised stee strip or wire armoured , electric power cable (heavy duty) w, 1100 V grade with aluminium conductorof 10 sqmm, 4 core complete all as specified & directed by Engr-in-Charge.
75
-
-
... More
S&F GI tubing light grade 80mm dia with all fittings laid in trenches/fixed on wall/ceiling including dismantling of old pipe etc. complete all as specified & directed by Engr-in-Charge.
7
-
-
... More
Excavation in trenches not exe 1.5m depth and not exe 1.5m wide in Soft/loose soil and getting out complete as specified and directed by Engr-in-Charge.
15.19
-
-
... More
M & L for road cutting /hard standing for laying of cable and re making good the same to match the existing surface complete all as specified & directed by Engr-in-Charge.
4
-
-
... More
Supply and spread river sand for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified & directed by Engr-in-Charge.
6.08
-
-
... More
Supplying laying, brick sub class 'B' common burnt laid in trenches for cable protection complete all as specified & directed by Engr-in-Charge.
0.6
-
-
... More
Returning, filling in including spreading, leveling, watering and well ramming in layers not exe.25cm at a level complete all as specified & directed by Engr-in-Charge.
7.92
-
-
... More
Removal of surplus soil to a distance not exe 50m and depositing where directed at a level not exe1.5m above the starting point complete all as specified & directed by Engr-in-Charge.
7.27
-
-
... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and refixing the same as per exiting floor tiles complete all as specified & directed by Engr-in-Charge.
40
-
-
... More
Dismantaling of 10 Sqmm 2 Core cable carefully mounted on wall and making good disturbed surface to match with the existing surface of roof/ wall/ floor by applying putty and applying colour/ white wash finish complete all as specified & directed by Engr-in-Charge.
75
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%