Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 Nov 2024
Closing Date11 Dec 2024
Tender Amount₹ 47,65,000
Costs
EMD
₹ 96,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684737_1Tender No
GE/RND/T-69/DLI/2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://mes.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
One 3 pin socket outlet on same board.
34
-
-
One light point controlled by two way switches.
6
-
-
All as per item No 1.00 here in before but for one socket point out let 3 pin 15 Amp with 2.5 sqmm PVC copper conductor FRLSH and 2.5 sqmm PVC insulated copper conductor FRLSH as earth continuity conductor.
243
-
-
M&L for power point wiring concealed type with PVC insulated unsheathed copper cable FRLS 4 sqmm multi stranded two single copper conductor in Including 20 mm PVC conduit pipe complete with all accessories and with 2.5 sqmm PVC insulated copper cable FRLS continous earth wire, re-recessed mounting pressed steel (mild steel) sheet box suitable for modular switch/sockets/AC metal clad socket of adequate size complete all as specified and directed.
75
-
-
Supply and fixing in replacement modular switch single pole one way 6 Amps 1 module complete all as specified and directed
498
-
-
Supply and fixing in replacement modular switch single pole Two way 6 Amps 01 module complete all as specified and directed
12
-
-
Supply and fixing in replacement modular switch single pole one way 16/20 Amps 1 module complete all as specified and directed
243
-
-
M&L in replacement modular socket 6 A/16 amp -3/5 pin combined 2 module complete all as specified and directed.
243
-
-
M&L in replacement modular socket 6 A-2/3 pin combined 2 module complete all as specified and directed.
121
-
-
S&F in replacement metal flush box and cover plate for modular switches 4 module complete all as specified and directed
6
-
-
S&F in replacement metal flush box and cover plate for modular switches 3 module complete all as specified and directed
257
-
-
S&F in replacement metal flush box and cover plate for modular switches 6 module complete all as specified and directed
16
-
-
S&F in replacement metal flush box and cover plate for modular switches 8 module complete all as specified and directed
12
-
-
S&F in replacement metal flush box and cover plate for modular switches 12 module complete all as specified and directed
20
-
-
S&F in replacement ceiling rose, surface bakelite 65x50mm three terminals complete all as specified and directed
238
-
-
S&F in replacement fan step regulator, 120W, 2 Module complete all as specified and directed
73
-
-
Taking down of ceiling/wall fan and refixing after minor repair like replacing bearing, bushes and painting with two coats of white/existing paint and marking the MES number complete all as specified and directed.
99
-
-
Taking down of exhaust fan upto size 250mm and refixing after repair/rewinding with the existing wire gauge, replacing bearing, bushes and marking the MES number complete all as specified and directed.
9
-
-
S&F for TP&N vertical load line DB double door Make: Legrand Cat part No. 507753 or equivalent as approval by GE with provision of MCCB as Incomer upto suitable 160 Amps, 415 volts 8 way, 50 Hz complete all as specified and directed Note: MCCB and MCB shall be measured and paid against respective item of BoQ.
2
-
-
S&F for TP&N vertical load line DB double door with provision of MCCB as Incomer upto suitable 160 Amp, 415 volts 04 way, 50 Hz complete all as specified and directed
Note: MCCB and MCB shall be measured and paid against respective item of BoQ.
16
-
-
S&F for SP&N DB with 63 Amps rated bus bar, double door with 230 volts 12 way, 50 Hz complete all as specified and directed
8
-
-
S&F for SP&N DB with 63 Amps rated bus bar, double door with 230 volts 8 way, 50 Hz complete all as specified and directed.
8
-
-
S&F MCB 6-32Amps,10 KA SP C-curve complete all as specified and directed
512
-
-
S&F MCB TPN 63 Amps C curve, 10 KA complete all as specified and directed
16
-
-
S&F MCB SPN 40 Amps C curve,10 KA complete all as specified and directed
16
-
-
S&F in replacement MCCB of 04 pole 125 amp, TPN, 16 KA (Ics=Icu=100%) thermal magnetic based with adjustable over current short circuit current with in bulk LCD display for trip cause alongwith tined copper spreader links, extended rotary handle, phase barrier (both side), Aux contact for on and trip indication complete all as specified and directed.
4
-
-
S&F in replacement MCCB of 04 pole 100 amp, TPN, 16 KA (Ics=Icu=100%) thermal magnetic based with adjustable over current short circuit current with in bulk LCD display for trip cause alongwith tined copper spreader links, extended rotary handle, phase barrier (both side), Aux contact for on and trip indication complete all as specified and directed.
12
-
-
S&F in replacement MCCB of 04 pole 500 amp, TPN, 50 KA (Ics=Icu=100%) microprocessor based with adjustable over current short circuit current with in bulk LCD display for trip cause alongwith tined copper spreader links, extended rotary handle, phase barrier (both side), Aux contact for on and trip indication complete all as specified and directed.
2
-
-
S&F in replacement of sheet metal enclosure SPN type with 2 pin and earth plug and socket (industrial type with an including one MCB SP, C-curve type of capacity 20 Amp, 10 KA complete all as specified and directed
60
-
-
Taking down and refixing sheet metal enclosure SPN type with 2 pin and earth plug and socket (industrial type with an including one MCB SP, C-curve type of capacity 20 Amp, 10 KA complete all as specified and directed. Note : Serviceable Sheet metal enclosure will be fixed at different location/floor in same building.
15
-
-
M&L for Wiring for circuit/submain wiring alongwith earth wire of FRLS PVC insulated copper conductor,single core cable in surface/recessed of size 4X16 sq mm + 2X10 Sq mm earth wire including 50mm PVC conduit and lugs/thimble with nuts,bollts and washers etc complete including taking down existing old unserviceable wiring complete all as specified and directed
160
-
-
M&L for wiring for circuit/submain wiring alongwith earth wire of FRLS PVC insulated copper conductor,single core cable in surface/recessed of size 2X6 sq mm + 1X6 Sq mm earth wire including 25mm of PVC conduit and lugs/thimble with nuts,bollts and washers etc complete including taking down of existing unserviceable wiring complete all as specified and directed
300
-
-
M&L for wiring for circuit/submain wiring alongwith earth wire of FRLS PVC insulated copper conductor,single core cable in surface/recessed of size 4X10 sq mm + 2X6 Sq mm earth wire including 32mm of PVC conduit and lugs/thimble with nuts,bollts and washers etc complete including taking down of existing unserviceable wiring complete all as specified and directed
350
-
-
M&L in replacement of Wiring for circuit/submain wiring alongwith earth wire of FRLS PVC insulated copper conductor,single core cable in surface/recessed of size 2X10 sq mm + 1X6 Sq mm earth wire including 25mm of PVC conduit and lugs/thimble with nuts,bollts and washers etc complete including taking down of existing unserviceable wiring complete all as specified and directed
200
-
-
S&F in replecement energy efficient LED light fitting, slim LED panel, recessed mounting2 ftx 2 ft made out of power coated CRCA sheet with acrylic diffuser, constant current output of electronic driver operating voltage range of 150 to 270 volts AC, PF0.95, high powder LEDs having efficiency of 100-120 lumins/watts, junction temparature less than 85 degree C and TH less than 12 % and CCT 6500K,, CRT90 suitable for 36 watt LED, LM 80 certified LM, pri wired in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose /connector etc and testing complete all as specified and directed.
91
-
-
S&F in replecement energy efficient LED light fitting, slim LED panel, surface mounting 2'x2' made out of power coated CRCA sheet with acrylic diffuser, constant current output of electronic driver operating voltage range of 150 to 270 volts AC, PF0.95, high powder LEDs having efficiency of 100-120 lumins/watts, junction temparature less than 85 degree C and TH less than 12 % and CCT 6500K, CRT90 suitable for 36 watt LED, LM 80 certified LM, pri wired in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose /connector etc and testing complete all as specified and directed.
100
-
-
S&F in replacement energy efficient LED light fitting surface mounted 4' long, 20 watt, 240 volts, 50 hz made out of extrunded aluminium housing with acrylic diffuser, LM 80 certified LED, costant current out put of electronic driver of operating voltage 140v to 270v and temperature - 10 degree centigrade to 50 degree centigrade with ingress protection IP 20 duly pre wired with insulated copper wire, PF0.95 with efficiency 120 lumins/watt and TDH less than 10%, CRI 90 degree , CCT 6500 K in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose complete all as specified and directed.
59
-
-
S&F in replacement energy efficient LED light fitting surface mounted 2' long, 10 watt, 240 volts, 50 hz made out of extrunded aluminium housing with acrylic diffuser, LM 80 certified LED, costant current out put of electronic driver of operating voltage 140v to 270v and temperature - 10 degree centigrade to 50 degree centigrade with ingress protection IP 20 duly pre wired with insulated copper wire, PF0.95 with efficiency 120 lumins/watt and TDH less than 10%, CRI 90 degree , CCT 6500 K in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose complete all as specified and directed.
17
-
-
Supply installation testing and commissioning factory made and tested (incl CPRI type test certified) LT feeder pillar box (KIOSK) outdoor type plateform mounted suitable for 415 volts 3 phase 4 wire 50 Hzs AC supply system having bus bar chamber with insulated Alluminium bus bar 1200 Amps rating installed on porcelain insulators. The panel shall be dust and virmin proof IP 65 cass protection and made of 3.15mm CRCA MS sheet and 50x50x6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer inside, front opening type with provisions for cable entry with double door shutter and locking arrangement including probision of 65mm godrej freedom lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The Panel shouild be suitable in and including civil work for panel foundation with PCC (1:2:4) at suitable height and including the following :-
(A) Main Incoming : ACB with microprosessor release based,100% ICS=100% ICU, 800 A 4 pole, 415 volt -01 Nos
(B) Outgoing Main MCCB 4P 500A with microprosessor release based,100% ICS=100% ICU, 50 KA - 01 No (For lighting) (i) Outgoing MCCB TPN 100Amps with thermal magnetic release based,100% ICS=100% ICU, 25KA - 3 No. ( for AC) (ii) Outgoing MCCB TPN 63 Amp with thermal magnetic release based,100% ICS=100% ICU 16 KA - 1 Nos (GF Flr AC)
(C) Metering, indication
(i) Set of RYB phase indication lamps - 01 set of three
(ii) Digital type Multimeter CTs , PTs and selector switch (D) Terminal connection between busbar and switchgear shall be insulated aluminium strip with colour code.
(i) one set of 1000 amps copper bus bar with PVC sleeve with minimum clearance of 25mm is required between phases and between phase & earth.
Note :- Before execution of work the drawing of LT Panel shall be got approval by GE.
1
-
-
M&L for earthing complete with copper plate 300×300cm ×3 mm thick burried in ground vertically to a depth not less than 2.5 meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. copper plate connected with 25×3mm copper strip by means of Copper nuts, bolts and washers. Copper strip shall be laid in 40 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :-
(a) 25 x 3 mm copper strip.
(b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits)
(c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
2
-
-
S&F in replacement earth continuity conductor or main earthing lead fixed to wall or batten or recess or chases or burried in ground or drawn in coduit/ any other indicated situation for loop earthing etc. As required of size 25x3mm copper strip complete as specified.
82
-
-
Excavation in trenches in soft/loose soil not exceeding 1.5m depth & not exceeding 1.5m in width over energised LT cables for carrying out brick work for protection of cable duct including for taking out and relaying of LT Cables complete all as specified and directed.
45.1
-
-
All as per item No. 41.00 but in hard / dense soil.
15
-
-
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and directed.
54
-
-
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
6.1
-
-
Supply & laying dry fine sand for cushioning of underground cable laid in trenches/duct complete all as specified and directed.
Note - Punned thickness shall be measured.
18.7
-
-
Supplying and laying reinforced precast concrete cable cover, class EHV, type 1 with flat, size 250mm x 150mm x 40m complete all as specified and directed.
1450
-
-
Supply and laying in replacement of old unserviceable GI pipe medium grade of 80 mm dia including GI fittings laid in trenches for protection of UG cable complete all as specified and directed
30
-
-
All as per item No. 47.00 above but 50 mm dia.
15
-
-
Supply and laying in trenches, fixed to wall / pole/ tray etc UG cable XLPE insulated armoured heavy duty electric UG cable with aluminium conductor 1100 volts grade of cross sectional area of following size.
-
-
-
35 Sqmm 3.5 Core
100
-
-
50 Sqmm 3.5 Core
150
-
-
M & L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) for coping of pole and filling in road cuts/ hard standing complete all as specified and directed.
3.5
-
-
Boring of holes under road , pavement , hard standing by trenches techonology using ultra sound technology/ mannualy mechanically and necessary machine for upto 100 mm dia GI pipe complete all as specifed and directed.
45
-
-
S&F DLP U PVC trunking system plastic adoptable type 50x150x50mm with two compartment duly covered installed with suitable support joints incl all accessories complete all as specified and directed.
150
-
-
S&F in replacement LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
2
-
-
M&L for rendering plaster in CM1:6 finshed even & fair without using extra cement complete all as specified and directed.
100
-
-
M&L for preparation of new previously untreated suface & applying two coats of oil emulsion distemper over 1mm thick wall care putty.
100
-
-
M&L for GI bracket made of 40 mm medium grade GI pipe bend to shape approx 1.2 mtr length including mild steel flat iron Clamps with nut bolts etc complete for fixing of street light including taking out old unserviceable GI brackets complete all as specified and directed.
2
-
-
S&F manually opening and closing roller type blinds of approved make with characteristic composition 100% polyster (translucent), weight 230 gm/Sqm and thickness 0.35mm complete all as specified and directed by Engineer-in-Charge.
442
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%