If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 95,860Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_635968_1Bid Award Id
ViewTender No
GE (FBD)/AF-49/2023-2024Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
All as per item No 01 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly complete all as specified and directed by Engineer-in-Charge
190
-
-
S&F modular white cover plate with frame, 3 module complete all as specified and directed by Engineer-in-Charge
375
-
-
S&F modular white cover plate with frame, 6 module complete all as specified and directed by Engineer-in-Charge
26
-
-
S&F modular white cover plate with frame, 8 module complete all as specified and directed by Engineer-in-Charge
16
-
-
S&F Metal Flush boxes 3 module complete all as specified and directed by Engineer-in-Charge
375
-
-
S&F Metal Flush boxes 6 module complete all as specified and directed by Engineer-in-Charge
26
-
-
S&F Metal Flush boxes 8 module complete all as specified and directed by Engineer-in-Charge
16
-
-
M&L modular switch 1 way 6 A, 1 module complete all as specified and directed by Engineer-in-Charge
485
-
-
S&F modular fan regulator -1 module complete all as specified and directed by Engineer-in-Charge
45
-
-
M&L modular socket, 6A-2/3 pin combined, 2 module complete all as specified and directed by Engineer-in-Charge
225
-
-
M&L modular Switch 16A, 6 pin, 3 module complete all as specified and directed by Engineer-in-Charge
190
-
-
M&L modular Socket 16A, 6 pin, 3 module complete all as specified and directed by Engineer-in-Charge
190
-
-
S&F switch piano type 5 amp SP one way ISI Marked complete all as specified and directed by Engineer-in-Charge
40
-
-
S&F 15 Amps SP one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
25
-
-
S&F socket outlet 3 pin 5 Amps flush type complete all as specified and directed by Engineer-in-Charge.
20
-
-
S&F socket outlet 2-in-1, 3 pin 5 amp and 15 amps complete all as specified and directed by Engineer-in-Charge.
20
-
-
M&L and fixing following modular switch/ socket on switch box and plate including connections as required complete all as specified and directed by Engineer-in-Charge :-
-
-
-
All as per item No 20 above but Telephone socket outlet
20
-
-
All as per item No 20 above RJ-45 Computer Socket Outlet
25
-
-
All as per item No 20 above T.V outlet
3
-
-
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-Charge.
60
-
-
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge.
12
-
-
Supply and fixing LED light fitting Bulk head with high out put diffuser 10 watt 220 V AC with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge.
18
-
-
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engineer-in-Charge.
55
-
-
S&F MCB SP 5 to 32 Amps, 240 volts curve 'C',breaking capacity 10KA, complete all as specified and directed by Engineer-in-Charge.
384
-
-
S&F MCB SPN 32 /40 Amps, 240 volts, curve 'C', breaking capacity 10 KA, complete all as specified and directed by Engineer-in-Charge.
28
-
-
S&F MCB TPN 63 Amps, 415 volts curve 'C',breaking capacity 10KA, complete all as specified and directed by Engineer-in-Charge.
8
-
-
S&F MCCB, Four pole, 415 volts, 125 Amps , curve 'C', breaking capacity 10 KA, complete all as specified and directed by Engineer-in-Charge.
12
-
-
S & F distribution board iron clad, double door with IP-54 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 6 way, VTPN DB complete with appropriate size copper bus bar and neutral link complete . MCCB and MCB should be of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engineer-in-Charge (Incoming MCCB and MCB will be measured separately)
2
-
-
S & F distribution board iron clad, double door with IP-54 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, VTPN DB complete with appropriate size copper bus bar and neutral link complete . MCCB and MCB should be of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engineer-in-Charge (Incoming MCCB and MCB will be measured separately)
10
-
-
S & F distribution board iron clad, double door with IP-43 protection suitable for MCB TP 415 Volts 3 phase 50 C/s as incommer and 240V SP/SPN MCB as outgoing 4 way, TPN DB complete with appropriate size copper bus bar and neutral link complete . MCBs should be of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engineer-in-Cahrge (MCB will be measured separately)
8
-
-
S&F sheet metal enclosures DB Double door type 8 way SPN 240 volt including 200 Amps rated bus bar with neutral link including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engineer-in-Charge. (MCB will be measured separately).
28
-
-
S&F for ceiling rose surface bakelite 65x50mm two to three terminals complete all as specified and directed by Engineer-in-Charge.
525
-
-
M&L submain wiring with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2.5 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site Note : Two runs of 4 sqmm cable alongwith one run of 2.5 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length) complete all as specified and directed by Engineer-in-Charge.
600
-
-
M&L submain wiring with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site Note : Two runs of 6 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length) complete all as specified and directed by Engineer-in-Charge.
350
-
-
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed by Engineer-in-Charge.
12
-
-
S&F Single pole and neutral enclosure with a two pin and earth Plug and socket complete with provision of one single pole MCB 20 Amp SP MCB C Curve 10 KA complete all as specified and directed by Engineer-in-Charge.
Note :- MCB shall be measured and paid separately
58
-
-
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. IP 66 protection complete all as specified and directed by Engineer-in-Charge.
15
-
-
M&L earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc complete all as specified and directed by Engineer-in-Charge.
6
-
-
Supplying and fixing PVC conduit 25 MM dia along with accessories in surface/recess I/C or cutting the wall and making good the same in case of recessed conduit as required complete all as specified and directed by Engineer-in-Charge.
50
-
-
S&F in replacement of Casing capping double lock type supper quality size 15 mm width ISI marked with fixing accessories complete all as specified and directed by Engineer-in-Charge.
250
-
-
Supply and installation of PVC Duct 100 mm width For AC copper pipes and insulation complete all as specified and directed by Engineer-in-Charge.
150
-
-
M&L for Recess mounted 15 Watt high efficancy recess LED slim round downlighter IP20 with high brightness LED for glare free homogenous illumination celing light complete with electronic driver complete all as specified and directed by Engineer-in-Charge.
50
-
-
Supply and fix in repair on load changeover switch 1250 amp 4 pole ,415 V,50 Hz in sheet steel enclosure for surface mounting with padlocking facility with the connecting accessories complete all as specified and directed by Engineer-in-Charge.
1
-
-
Supply and fix in repair on load changeover switch 1000 amp 4 pole ,415 V,50 Hz in sheet steel enclosure for surface mounting with padlocking facility with the connecting accessories complete all as specified and directed by Engineer-in-Charge.
1
-
-
Supply, installing testing and commissioning in replacement of factory made and tested (Including CPRI test cetified) indoor type floor mounted LT panel board, cubical type suitable for 415 Volts 3 phase, 4 wire 50Hz, Ac supply system having busbar chamber with insulated AL busbar of rating 1.5 times the incomer ACB for phase installed on porcelin/SMC insulators. The panel shall be dust and vermin proof IP-64 class protection and made out of 3.15 mm thick CRCA MS sheet and angle iron frame 50x 50x 6mm thick frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with aproaches for cable entry with double door shutter and locking arrangements including internal wiring with PVC insulated stranded copper conductor cable FRLS IS 694 sheathed 1100V grade of appropriate size comprising of following:-
INCOMING-
(i) Mains ACB 4 pole 415 Volt, 1250 Amps manual drawout with microprocessor release, -01 No.
OUTGOING-
(i) ACB 3 pole 800 Amps,, 415 Volts (manual drwaout type).-02 No.(01 No Spare)
(ii) MCCB 4 pole 415 volts with rating thermal magnetic prottection unit rupturing cap 25 KA,with Rotary handle , 200 amps - 02 Nos for outgoing.
(iii) MCCB 4 pole 415 volts with rating thermal magnetic prottection unit rupturing cap 25 KA, 160 amps - 01 Nos for outgoing.
(iv) MCB SPN 32 AMP 03 Nos . (v) Indicator set RYB -01 Set of 3 pcs only .
(vi) MCB ,SP 10 amps 03 Nos ( for metering equipment)
(vii) Digital Amp meter with CTs & built in selector switch-01 No.
2
-
-
Note : All as per item No 49 Contd…../-
OUTGOING-
(viii) Indication lamp RYB-01 Set.
(ix) Multifunction digital panel meter suitable to display amps, volts, frequency etc - 01 No including CTs of appropriate ratio. (x) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed by Engineer-in-Charge
-
-
-
Supply, installing testing and commissioning in replacement of factory made and tested (Including CPRI test cetified) indoor type floor mounted LT panel board, cubical type suitable for 415 Volts 3 phase, 4 wire 50Hz, Ac supply system having busbar chamber with insulated AL busbar of rating 1.5 times the incomer ACB for phase installed on porcelin/SMC insulators. The panel shall be dust and vermin proof IP-64 class protection and made out of 3.15 mm thick CRCA MS sheet and angle iron frame 40x 40x 6mm thick frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with aproaches for cable entry with double door shutter and locking arrangements including internal wiring with PVC insulated stranded copper conductor cable FRLS IS 694 sheathed 1100V grade of appropriate size comprising of following:-
INCOMING-
(i) Mains ACB 4 pole 415 Volt, 1250 Amps manual drawout with microprocessor release, -01 No.
OUTGOING-
(i) ACB 3 pole 800 Amps,, 415 Volts (manual drwaout type).-01 No.
(ii) MCCB 4 pole 415 volts with rating thermal magnetic prottection unit rupturing cap 25 KA,with Rotary handle , 250 amps - 02 Nos for outgoing.
(iii) MCCB 4 pole 415 volts with rating thermal magnetic prottection unit rupturing cap 25 KA, 160 amps - 01 Nos for outgoing.
(iv) MCB SPN 32 AMP 03 Nos . (v) Indicator set RYB -01 Set of 3 pcs only .
(vi) MCB ,SP 10 amps 03 Nos ( for metering equipment)
(vii) Digital Amp meter with CTs & built in selector switch-01 No.
1
-
-
Note : All as per item No 51 Contd…../-
OUTGOING-
(viii) Indication lamp RYB-01 Set.
(ix) Multifunction digital panel meter suitable to display amps, volts, frequency etc - 01 No including CTs of appropriate ratio. (x) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed by Engineer-in-Charge
-
-
-
M & L for temporary fixing of new LT pannel (Supplied against Item NO 49 and 50) outside Sub Station building room for temprory arrangement of electrcity to entire area near substation location as a temprory installations and refix the same after compeition of job work as mentioned agaisnt Srl Item No to inside sub station building room against item no 49 and 50 . All cable connecting items/ electical dis-connection / elelctrical re- connection must be included in rate complete all as specified and directed by Engineer-in-Charge.
2
-
-
M & L for taking out existing LT panel installed at substation building room out side the substation room includig removal of electric disconnection of all LT cables for repairing , servicing and replacement of LT panels unsv part including complete breakable accesories such as partialy open door , breakable door , Unsv Al bus bar , unsv locking arrangement, repairing of LT Panel legs, welding work , all cable disconnecting items/ T&P items must be included in rate complete all as specified and directed by Engineer-in-Charge.
10
-
-
M & L for re-fixing / Re - Installed of exisiting LT Panel (taking out agaist item No 52)of any capacity, any size , any tpye (indoor or outdoor type), (disconnected against item No 52 ) after repairing / servicing including cleaning properly of all parts ,removing dust, carbon deposits etc of connections, making all connections and re-installation of existing LT panel to same location or any other location after painting of LT panel including removing old dust partical,oily porytion by rubbing with sand paper with spary pump, and writing /digital printing, Capacity Descripton, date of installation,etc with complete electrical connection with existing cable complete all as specified and directed by Engineer-in-Charge.
Note coted rate includes neceassry PCC work , Excavtaion , removal , retruning filling including disconnection and reconnection of cables , for any size any capacity LT Panel .
8
-
-
Labour only for taking out from trenches, wall, pole , Pipe, PCC, under ground, etc exsisting cable LT 1100 volt grade heavy duty , armoured with steel strip of wire , with stranded aluminium conductor of any size, any core, for seggregation of serviceable cable lenght ,unserviceable cable lenght and unuse cable lenght by meggering or any other suitable and recommended method including disconnection and re-connection of Cables. Removing unserviceable and unuse cable leght from site and keeping aside serviceable for reuse at same location or any other location complete all as specified and directed by Engineer-in-Charge.
(Earth work will be measured and paid separately under respective item).
500
-
-
Labour only for taking out from trenches, wall, HT pole , Pipe, PCC, under ground, etc exsisting cable HT 11000 volt grade heavy duty , armoured with steel strip of wire , with stranded aluminium conductor of any size, any core, for seggregation of serviceable HT cable lenght ,unserviceable HT cable lenght and unuse cable lenght by meggering or any other suitable and recommended method including disconnection and re-connection of HT Cable conntection. Removing unserviceable and unuse HT cable leght from site and keeping aside serviceable for reuse at same location or any other location complete all as specified and directed by Engineer-in-Charge.
(Earth work will be measured and paid separately under respective item).
200
-
-
Excavation in trenches not exc 1.5 m wide in depth for laying of cable or pipe for protection of cables or fixing of poles struts or stays and getting out in hard dense soil including trimmimg the side and forming bottom surfaces to required level complete all as specified and directed by Engineer-in-Charge.
50
-
-
M&L for Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engineer-in-Charge.
27
-
-
Removal of excavated soil to a distance not exc 50m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-Charge.
23
-
-
M&L sand cushioning for under ground cable 08 cm layer below the cable and 15 cm layer above the cable complete all as specified and directed by Engineer-in-Charge.
20
-
-
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 sq. mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
225
-
-
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 sq. mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
150
-
-
M & L for brick protection with sub class 'B' bricks laid dry flat over electric cable in trenches complete all as specified and directed by Engineer-in-Charge.
1800
-
-
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx 6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge o the plate not less1.5 mtrs below normal ground level connected to galvanised earth strip 32 x 6 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.5 connected to earthing test point incl necessary earth work, excavation PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provn of PCC cover 40 mm thick 1:2:4 mm type B1 funnel with water Pipe, GI pipe, 15mm dia medium grade protection pipe, GI earth lead complete all as specified and directed by Engineer-in-Charge. Note : (i) Earth lead and protection pipes length up to including 7.5 mtr (ii) Earth filling shall be done by veg soil (iii) Soil Should be free from stone , boulders , aggregates, gravels etc
5
-
-
M&L for broken bricks hard core gauge n.exc 63mm deposited, spred and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces complete all as specified and directed by Engineer-in-Charge.
1
-
-
M&L for PCC (1:3:6) type C2 using 40 mm graded aggr as in surface channels and drains complete all as specified and directed by Engineer-in-Charge.
1
-
-
M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
10
-
-
M&L rendering 15mm thick in CM (1:4) on brick work or concrete surfaces smooth & even with using extra cement complete all as specified and directed by Engineer-in-Charge.
10
-
-
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping/benching and all other similar works including necessary formwork complete all as specified and directed by Engineer-in-Charge.
0.5
-
-
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc complete all as specified and directed by Engineer-in-Charge.
12
-
-
S & F for mild steel framed work as in grill, guard bars etc with ends of bars/FI shoulders and or riveted or forged in to spikes, framed guard bar and similar works confirming to Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge.
560
-
-