Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 94,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_663476_1Bid Award Id
ViewTender No
GE ELECT/D-24/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Returning filling in, including spreading, leveling, Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engineer- in- Charge.
453
-
-
... More
Removing excavated material (i.e. soil) from site to a distance n. exec 50 mtrs away and depositing where directed at a level nexc 1.5 mtr above the starting point compelte all as specified and directed by Engineer-in-Charge.
254.4
-
-
... More
M&L for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc complete all as specified and directed by Engineer- in- Charge. Note : Measurement shall be taken after punning down.
212.22
-
-
... More
S&F sub class B bricks of size 230mmx115mmx70mm having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
15
-
-
... More
All as per srl item No 7.00 here-in-before but using old bricks complete all as specified and directed by the Engg-in-Charge.
7783
-
-
... More
Demolition of road, path, drain and concrete in ground floors, RCC/Brick wall (below or above ground level) complete all as specified and as directed by Engi-in- Charge.
0.25
-
-
... More
M&L for providing PCC 1:2:4 type B-2 (using 40 mm grade crushed stone aggregate) 50 mm Thick as in road, path, drain, concrete in ground floors, RCC/Brick wall or similar works complete all as specified and as directed by Engr in charge.
0.25
-
-
... More
M&L for disconnecting of damaged unserviceable underground cable and Supplying, laying, jointing testing and connecting in replacement of XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed of following sizes:-
Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
-
-
-
... More
16 Sqmm 4 core
1500
-
-
... More
25 Sqmm 4 core
500
-
-
... More
35 Sq mm 3.5 core.
300
-
-
... More
10 Sqmm 2 core
500
-
-
... More
Boring of hole under road/pavement/hard standing or any other situation by manual means, suitable for passing of GI pipe 40 to 100 mm bore and making good both ends complete all as specified and directed by Engineer- in- Charge.
40
-
-
... More
S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah complete all as specified and directed by the Engg-in-Charge, of the following bore sizes:-
-
-
-
... More
40 mm bore GI Pipe Light Grade
40
-
-
... More
HDPE pipe suitable for 5 kgf/cm 2 working pressure with all fitting size of size 40 mm dia bore.
50
-
-
... More
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for separately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs.
(c) Excavation and earth work will be measured and paid for separately under respective items of schedule.
600
-
-
... More
Supply, fixing, testing and comissioning Straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armored heavy duty aluminum conductor 1100 Volts grade complete all as specified and directed by the Engg-in-Charge, for the following sizes :-
-
-
-
... More
16 -25 sqmm x 4 core
4
-
-
... More
35-50 sqmm, 3.5 core
4
-
-
... More
S&F in replacement steel tubular swaged poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II) including excavation, earth work, PCC foundation, base plate,PCC coping,GI pipe for cable protection etc. and GI bracket for fitting mounting, complete all as per manufacturer's instructions complete all as specified and as directed by Engg-in-charge. NOTE:- 1.The unit rate in this item is deemed to be included the cost of PCC foundation 1:4:8 type D-2, PCC coping 1:2:4 type B-1. The steel pole shall be painted by bituminous paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminum paint over a coat of red oxide complete all as specified and directed. 2. Excavation, eath work and GI brackets will measured and paid separately under relevant item .
30
-
-
... More
S&F in replacement bracket for street light fitting complete with 1.5 to 2.2 mtr long 32/40mm dia GI pipe medium grade and including necessary mild steel clamp , nuts, bolts and washers and painting on steel surfaces with two coats of aluminum paint complete all as specified and directed by the Engg-in-Charge.
300
-
-
... More
M&L for Cutting / pruning of tree branches along security light pole around 2 mtr radius of security light and removing from site including arrangement of T&P (Axe, rope & ladder etc) complete all as specified and directed by the Engg-in-Charge.
500
-
-
... More
S&F in replacement MCB DP, 63 Amps, 50 Hz with 10 KA breaking capacity 240 Volts in existing Panels complete all as specified and directed by the Engg-in-Charge.
10
-
-
... More
S&F in replacement MCB SP, 6 to 32 Amps, 50 Hz,10 KA breaking capacity 240 Volts in existing Panels complete all as specified and directed by the Engg-in-Charge.
30
-
-
... More
S&F in replacement KIOSK box weather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Amps including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red color on front face of KIOSK box body incl necessary MS clamp of size 25x3 mm with suitable size nut, bolts & washer complete all as specified and directed by the Engg-in-Charge.
350
-
-
... More
M&L for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminum paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed by the Engg-in-Charge.
250
-
-
... More
Earthing in replacement complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanized ironsides complete all as specified, including testing and commissioning complete all as specified and directed by the Engg-in-Charge.
Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc.
(b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
15
-
-
... More
S&F in replacement of galvanized iron strip 32 X 6 mm for additional earthing lead beyond 7.5 meter complete all as specified and directed by the Engg-in-Charge.
50
-
-
... More
Supply drawing, connecting and testing in replacement of 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed copper conductor (flexible ) industrial cable, 1100 Volts conforming to IS 694 in steel tubular poles from KIOSK box to street light fitting including providing suitable copper lugs complete all as specified and directed by the Engg-in-Charge.
750
-
-
... More
-diito- all as Per Srl Item No.24 above but size of cable 3 core, 2.5 Sqmm complete all as specified and directed by the Engg-in-Charge.
720
-
-
... More
S&F in replacement of integral LED light fitting 45/60 watts comprising pressure die cast housing with power coated aluminum housing working as a heat shrink and toughened glass suitable for 32 mm OD pipe bracket with IP-65 protection complete all as specified and directed by the Engg-in-Charge
62
-
-
... More
-ditto- all as above but Street Light of cap 70-75 WATT
25
-
-
... More
-ditto- all as above but Street Light of cap 120/125 WATT
11
-
-
... More
-ditto- all as above but Street Light of cap 190/200 WATT
8
-
-
... More
S&F in replacement Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminum IP66 LED flood light suitable for high lighting architectural façade and general purpose lighting of capacity 120 Watt LED complete all as specified and directed by the Engg-in-Charge.
20
-
-
... More
M&L for disconnecting existing LED street lights/flood lights from PCC/GI poles for repairing of unserviceable LED street light fitting of any type/make of 45-60 watt capacity by replacing UNSV compact LED electronic driver, broken tempered glass, silicon gasket, led blubs, FMSPD suitable to operate on 150 to 277 Volt 50/60 Hz AC supply and reinstall at same location/place after repair work complete all as specified and directed by the Engg-in-Charge.
Note:- Supply only item no 28 to 31 are incorporated against all fitting covered under item no 27.
77
-
-
... More
-ditto- all as above but Street Light of cap 72/75 watt
30
-
-
... More
-ditto- all as above but Street Light of cap 120/125 watt
25
-
-
... More
-ditto- all as above but Street Light of cap 190/200 watt
9
-
-
... More
-ditto- all as above but flood lights 120 watt
4
-
-
... More
Supply only compact LED electronic driver suitable to operate on voltage 150 to 277 volt 50/60 Hz AC supply of cap 40/60 watts all as specified and directed by Engineer in charge.
20
-
-
... More
-diito- all as above but cap of 72/75 watt
8
-
-
... More
-diito- all as above but cap of 120/125 watt
2
-
-
... More
-diito- all as above but cap of 190/200 watt
2
-
-
... More
-diito- all as above but for flood lights of cap 120 watt
2
-
-
... More
Supply only LED tempered glass suitable for LED Light fitting of Cap 40/60 watts complete all as specified and directed by Engineer in charge.
15
-
-
... More
-diito- all as above but cap of 72/75 watt
5
-
-
... More
-diito- all as above but cap of 120/125 watt
2
-
-
... More
-diito- all as above but cap of 190/200 watt
2
-
-
... More
-diito- all as above but flood lights of cap 120 watt
2
-
-
... More
Supply only compact LED blub set suitable to operate on voltage 150 to 277 volt 50/60 Hz AC of cap 40/60 watts complete all as specified and directed by Engineer in charge
15
-
-
... More
-diito- all as above but cap of 72/75 watt
6
-
-
... More
-diito- all as above but cap of 120/125 watt
3
-
-
... More
-diito- all as above but cap of 190/200 watt
2
-
-
... More
-diito- all as above but flood lights of cap 120 watt
2
-
-
... More
Supply only compact LED FMSPD suitable to operate on voltage 150 to 277 volt 50/60 Hz AC of cap 40/60 watts complete all as specified and directed by Engineer in charge.
16
-
-
... More
-diito- all as above but cap of 72/75 watt
6
-
-
... More
-diito- all as above but cap of 120/125 watt
2
-
-
... More
-diito- all as above but cap of 190/200 watt
2
-
-
... More
-diito- all as above but flood lights of cap 120 watt
2
-
-
... More
S&F in replacement 3 Pole power contractor, type MNX 110 having 2 NO+2 NC contacts complete all as specified and directed by the Engg-in-Charge.
10
-
-
... More
S&F in replacement 3 Pole power contractor, type MNX 40 having 2 NO +2 NC contacts complete all as specified and directed by the Engg-in-Charge
5
-
-
... More
S&F in replacement MCCB 3 pole, 32 Amps, 50 Hz, 415 Volts, with 16 KA breaking capacity with thermal magnetic release complete all as specified and directed by the Engg-in-Charge.
10
-
-
... More
S&F in replacement Analog Time switch , 240 Volt AC , 50 Hz complete all as specified and directed by the Engg-in-Charge.
5
-
-
... More
S&F in replacement of Digital Time switch, 240 Volt AC, 50 Hz complete all as specified and directed by the Engg-in-Charge.
10
-
-
... More
Note for Srl item No. 25 to 36:- Contractor will make a identity (ie CANo. & firm name) using permanent paint marker pen on each component which will be replaced under repair of street light and he will be liable to change his new replaced item without any extra cost which become unserviceable due to any reason during execution period of CA and further up to defect liability period. It will be contractor responsibility to take the location of unserviceable street light fitting by MES rep at 9 AM at power house in every working day.
-
-
-
... More
M&L for cleaning of existing LT panel by using blower machine and using CRC spray to remove all dust particle from LT panels ,and changing all burnt out LT thimbles of any sizes by removing of old one complete all as specified and directed by Engineer in Charge.
25
-
-
... More
M&L for welding of existing LT panels doors by using Welding machine and all necessary T&P requied to finish the Job complete all as specified and directed by Engineer in Charge.
15
-
-
... More
M&L for carrying out balance distribution of load on LT Lines by checking the existing load on the feeder (3 phase,4wire system) and accordingly shifting & connecting service cables to another phase conductor in accordance with balancing of Electric load. submit feeder wise report for before load balancing and after load balancing as per format given including maintenance of LT panel i.e. tinting of all nuts, bolts, washers, cleaning of LT panel dust etc complete all as specified and directed by Engr-in-Charge.
20
-
-
... More
M&L for disconnecting burnt end or portion of cable removing the cable from loop including necessary excavation & earth work in soft/loose soil relaying and reconnecting the cable by removing burnt portion of cable and preparing fresh terminals including fixing of new lugs for 50 Sqmm 3½ / 4 to 400 Sqmm of LT cable to pole / main switch complete all as specified and directed by the Engg-in-Charge.
15
-
-
... More
M&L for applying two coats of Aluminum paint on steel surfaces/fencing over a coat of red oxide primer including preparation of old/new surfaces complete all as specified and directed by the Engg-in-Charge.
15
-
-
... More
S&F in replacement Voltmeter 0-500 V digital type as per existing size complete all as specified and directed by the Engg-in-Charge.
15
-
-
... More
S&F in replacement Ammeter 0-400 Amp digital type per existing size complete all as specified and directed by the Engg-in-Charge.
15
-
-
... More
S&F in replacement 3 way rotary selector switch complete all as specified and directed by the Engg-in-Charge.
10
-
-
... More
S&F in replacement indicator lamp for RYB phases complete all as specified and directed by the Engg-in-Charge.
10
-
-
... More
S&F in replacement LT current transformer having ratio 630/5 Amp , 15 VA, Class 0.5 Complete all as specified and directed by Engr-in-Charge.
5
-
-
... More
All as per Srl item No 47.00 herein before but CT ratio 400/5 Amp complete all as specified and directed by the Engg-in-Charge.
5
-
-
... More
All as per Srl item No 47.00 herein before but CT ratio 315/5 Amp complete all as specified and directed by the Engg-in-Charge.
5
-
-
... More
All as per Srl item N 47.00 herein before but CT ratio 250/5 Amp complete all as specified and directed by the Engg-in-Charge.
4
-
-
... More
All as per Srl item No 47.00 herein before but CT ratio 200/5 Amp complete all as specified and directed by the Engg-in-Charge.
5
-
-
... More
S&F in replacement cable gland for LT panel/feeder pilar up to 50 Sqmm cable size complete all as specified and directed by the Engg-in-Charge.
10
-
-
... More
All as per Srl item No.48 herein before but 70 sqmm cable to 185 Sqmm cable complete all as specified and directed by the Engg-in-Charge.
10
-
-
... More
All as per Srl item No.48 herein before but 240 sqmm cable to 400 Sqmm cable complete all as specified and directed by the Engg-in-Charge.
10
-
-
... More
M&L for cutting and removing grass, vegetation bushes etc from surrounding of installation/LT Panel and removing all rubbish to a distance not exceeding 50 m complete all as specified and directed by the Engg-in-Charge.
250
-
-
... More
M&L for re-painting of LT Panels/feeder pillars of approx size 2 to 4 Sqm with 2 coats of super enamel paint over a coat of red-oxide with sparygun including writing of feeder pillar numbers in appropriate size of letters complete all as specified and directed by the Engg-in-Charge.
20
-
-
... More
All as per item No 50.00 above but of approx size upto 1.90 Sqm complete all as specified and directed by the Engg-in-Charge.
20
-
-
... More
Supply, installing, testing and commissioning in replacement of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement of size not less than 400mm x 400mm x 300mm with 4 Nos 400 Amps aluminum bus bar and with 250 Amp MCCB, 4 pole, 25 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded stone aggregate, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded stone aggregate on top and grouting bolts etc for Bus bar chamber. The platform shall be such that it is of a height 45 cm above the nearest road level.
2
-
-
... More
Supply, install, testing and commissioning in replacement of factory made tested LT panel board cubical double door compartment outdoor type leg mounted suitable for , 415 volts 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated Copper bus bar of rating not less than 1.5 times of Incomer/ Outgoings ACB/MCCBs, installed on proceline/ SMC insulator. The panel shall be dust and vermin proof IP -65 class protection and made of 3.15 mm CRCA MS sheet and inner compartment 2.0 mm, 40X40X6 mm thick MS angle iron frame work, powder coated finished over one coat of red oxide on out side surface and painted in side with two coats of red oxide primer and rear opening type with apran for cable entery closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size (but not less than 1.5 sqmm) and comprising of the following including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size:- INCOMING:- (i) Air circuit breaker 4 pole 800 Amps 50 KA withwith Microprocessor release manual drawout Adjustable type- 1 Nos (iii) CT ratio 400/5 Amp class-1 ISI marked - 01 Set of three (iii) Voltmeter 0-500 V digital type with 3 way rotary selector switch - 01 No (iv) Ammeter 0-500 Amp digital type with 3 way rotary selector switch - 01 No (v) CT ratio 800/5 Amp class-1 ISI marked - 01 Set of three (vi) Indicating lamp one set of three OUTGOINGS:- (i) MCCB 3 pole, 315 Amps, 50 Hz, 415 Volts, 36 KA Adjustable Thermal and Adjustable Magnetic setting- 1 Nos (i) MCCB 3 pole, 250 Amps, 50 Hz, 415 Volts, 36 KA Adjustable Thermal and Adjustable Magnetic setting- 3 Nos (ii) MCCB 3 pole, 100 Amps, 50 Hz, 415 Volts, 25 KA Adjustable Thermal and Adjustable Magnetic setting- 2 Nos
1
-
-
... More
All as per item No 52 here-in-before complete all as specified and directed by the Engg-in-Charge but with INCOMING:- (i)MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 315 Amp Amps rating 36 KA rupturing capacity with adjustable Thermal and Magnetic setting releases, - 01 Nos. .
(ii) Digital Voltmeter 0-500 volts, square, 96 mm,flush pattern with 3 way selector switch - 01 No Make: SECURE / L&T (iii) Digital Ammeter 96mm x 96 mm, flush pattern with 3 way selector switch - 01 No. Make: SECURE / L&T (iv) 3 Nos of CTs of ratio 400/5 Amp copper wound, Class 1.0, 10 VA – 1 Set
(v) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-01 set (Make BCH/SIEMENS/L&T) OUTGOING:-
(ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 200 Amps rating 36 KA rupturing capacity with adjustable Thermal and Magnetic setting releases, - 01 Nos.
(ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 100 Amps rating 36 KA rupturing capacity with adjustable Thermal and Magnetic setting releases, - 5 Nos.
1
-
-
... More
All as per item No 52 here-in-before complete all as specified and directed by the Engg-in-Charge but with INCOMING:- (i)MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 315 Amp Amps rating 36 KA rupturing capacity with adjustable Thermal and Magnetic setting releases, - 01 Nos. .
(ii) Digital Voltmeter 0-500 volts, square, 96 mm,flush pattern with 3 way selector switch - 01 No Make: SECURE / L&T (iii) Digital Ammeter 96mm x 96 mm, flush pattern with 3 way selector switch - 01 No. Make: SECURE / L&T (iv) 3 Nos of CTs of ratio 400/5 Amp copper wound, Class 1.0, 10 VA – 1 Set
(v) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-01 set (Make BCH/SIEMENS/L&T) OUTGOING:-
(ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 100 Amps rating 16 KA rupturing capacity with adjustable Thermal and Magnetic setting releases, - 07 Nos. Make of MCCB/MCB-Legrand/Havells/LT or equivalent.
1
-
-
... More
M&L for disconnecting all electric LT Supply from timer panel of High mast and lowering down the high mast light fitting set by using motor/manually for repair/replacement work and change the unsv/worn out parts after repair works completed check the serviceability of high mast and remove all dust/nest and greasing the rope/motor/gear assembly for proper functioning before raising up in the the original position complete all as specified and directed.
Note :- Item Nos 56 to 60 are incorporated in item no 55 as supply only.
4
-
-
... More
Supply only stainless steel rope 6mm dia complete all as specified and directed by Engineer-in-charge.
80
-
-
... More
Supply only D clamp including nut bolt and washers complete all as specified and directed by Engineer-in-charge.
20
-
-
... More
Supply only 6 Sqmm 5 Core flexible aluminum cable complete all as specified and directed by Engineer-in-charge
100
-
-
... More
Supply only 1.5 HP motor 3 Ph 440 volt 50 hz AC supply for operating the stainless steel rope through gear assembly complete all as specified and directed by Engineer-in-charge.
3
-
-
... More
Supply only gear assembly used for operating the stainless rope for lowering down the high mast fitting complete all as specified and directed by Engineer-in-charge.
5
-
-
... More
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements