Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 10,37,380Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_672212_1Tender No
CEWAC/PAL/T-02/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Construction of ORs and Equivalent , each block of 14 qtrs(G+3) including Stilt Parking with permanent specification complete all as specified and shown on drawings.
1
-
-
Construction of 'SERVICE TOILET' with permanent specification complete all as specified and shown on drawings.
1
-
-
Construction of 'RAIN WATER HARVESTING' complete all as specified and shown on drawings.
1
-
-
NOTE: Schedule ‘A’ Part II to XIV under are Prepriced by MES.
-
-
-
Lump sum price worked out by the Contractor for “SITE CLEARANCE INCL EARTHWORK & EXCAVATION” as listed in Schedule ‘A’ Part II
1
1618399
-
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part III
1
6728884
-
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part IV
1
1315864
-
Lump sum price worked out by the Contractor for “AREA DRAINAGE as listed in Schedule ‘A’ Part V
1
2557983
-
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part VI
1
1403423
-
Lump sum price worked out by the Contractor for “ROAD PATH & CULVERT ” as listed in Schedule ‘A’ Part VII
1
3434469
-
Lump sum price worked out by the Contractor for “LIFT” as listed in Schedule ‘A’ Part VIII
1
106020
-
Lump sum price worked out by the Contractor for “DG SET” as listed in Schedule ‘A’ Part IX
1
37864
-
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part X
1
427237
-
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’ Part XI
1
1302612
-
Lump sum price worked out by the Contractor for “DEMOLITION & DISMANTLING” as listed in Schedule ‘A’ Part XII
1
7839861
-
Lump sum price worked out by the Contractor for “ARBORICULTURE” as listed in Schedule ‘A’ Part XIII
1
41732
-
Lump sum price worked out by the Contractor for “VERMICOMPOST” as listed in Schedule ‘A’ Part XIV
1
298981
-
SCHEDULE `A' PART - XV MISC B/R & E/M ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only.
-
-
-
INTERNAL ELECTRIFICATION
-
-
-
S&F Telephone socket RJ-11, single phase, complete all as specified and directed.
56
-
-
LIFT
-
-
-
Design supply, install, testing and commissioning 13 passenger lift (884Kg), speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665, suitable to serve G+03 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without handset (04 Nos, one each in car, Machine room & near ground floor landing door),one fireman switch at GF complete with LED concealed lights in ceiling of car all as specified & directed.The following items shall be provided in the lift and cost thereof shall be deemed to be inclusive in the quoted price. NOTE:- 1.Floor of lift shall be of grey or black granite or marble as directed by GE. 2. A recessed fan in the ceiling with metal diffuser. 3. All fixing accessories in addition to the standard mountings as per lift manufacturer if required at site. 4. Any other parts/components required for smooth operation of the lift. 5. Light and sockets required in the lift shaft as per OEM's requirement
1
-
-
Design supply, install, testing and commissioning 08 passenger lift (544Kg), speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665, suitable to serve G+07 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without handset (04 Nos, one each in car, Machine room & near ground floor landing door), one fireman switch at GF complete with LED concealed lights in ceiling of car all as specified & directed. The following items shall be provided in the lift and cost thereof shall be deemed to be inclusive in the quoted price. NOTE:- 1.Floor of lift shall be of grey or black granite or marble as directed by GE. 2. A recessed fan in the ceiling with metal diffuser. 3. All fixing accessories in addition to the standard mountings as per lift manufacturer if required at site. 4. Any other parts / components required for smooth operation of the lift. 5. Light and sockets required in the lift shaft as per OEM's requirement
6
-
-
DG SET
-
-
-
Supplying, installing, commissioning and testing Silent Diesel Generating Set with AMF Panel with automatic On load change over switch(ATS Switch) comprising of necessary contractor, relays, timer etc of suitable capacity not less than 75 KVA/66KW capacity 3 phase with water cooled engine of sutable BHP for 66KW power generation @RPM 1500, brushless frame with silencer and canopy for sound less mode (sound level not exceeding 65 dB as specified by CPCB) and all engine accessories such as self starter, alternator/dynamo and 75KVA/66KW electric alternator, 415Volt, 3 Phase 4 wire , 50 Hz, Voltage regulation + 15, insulation class H coupled to engine with suitable coupling and base frame on foundation as recommended by the manufacturer and consisting of other electrical components,auto Governor/auto voltage regulator fuel tank of capacity of not less than 12 Hr run with level indicator installed on suitable steel frame with PCC foundation as per manufacturers insructions, Power command genset controller, fuel pipes, dual spin on fuel filter , Dry type Air cleaner , shut off coil with safeties for LLOP/HWT, fuel pipes bar meter, hour meter, oil temperature gauges, ammeter,ignition switch , radiator with cooling fan, maintenance free battery including suitable size of copper cable leads with terminals , all mountings accessories and necessary foundation and AVM pads complete as per manufacturers recommendations and to the satisfaction of Engr in charge
1
-
-
(A) Prime Mover (Diesel Engine) :-
Prime mover Suitable for driving 75KVA/66KW alternator water cooled battery start diesel engine of adequate capacity conforming of BS 649 and fuel tank suitable for 12 hrs running capacity mounted on MS frame pedestral supported with anti vibration mounting rated for continuous running capable of taking 10% over load for one hr in any 12 Hrs operation complete with the following standard accessories :-
(a) Fly wheel to match with the flexible coupling
(b) Flexible coupling with guard
(c) Air cleaner Oil bath type/dry type as per OEM
(d) Lubricating oil filter, fuel filter paper element type
(e) Blower type fan and radiator
(f) Governor for class 'A' Governing as per IS-1601 (g) Starter motor for electric start complete with dyamo alternator, lead acid batteries heavy duty of capacity 12V 150Ah or adequate size , Nos and capacity as required with copper conductor leads of adequate size and length not less than 2M including battery box all as directed,
(h) Hour meter and RPM indicator
(j) Exhaust pipe through outside the building and lagging of entire length of exhaust pipe with 12mm dia (k) Instrument panel duly wired comprising the following including protection for low lub oils pressuer and high temperature
(l) Lub oil pressure gauge
(m) Battery change indicator meter
(n) Starting switch with key
(o) Lub oil temperature
(p) Water temperature
-
-
-
(B) Alternator
Alternator suitable for continuous operation generating 75 KVA/66 KW at 1500 rpm, 50 Hz, 415 volts at NTP 0.8 power factor 3 phase 4 wire 50 Hz, self excited & regulated, copper wound, coupled to prime mover , screen protected drip proof free from simulatenous problems continuous rating conforming to BS 2613 complete with automatic voltage regulator regulated between +/- 1% or set voltage from no load to full load and conforming to IS-13364.
(C) Fuel tank of suitable size as per manufacturers design powder coated with inlet and outlet connection and fuel level indicator.
(D) Base frame made out of suitable channel duly reinforced and provided with adequate numbers of anti vibration pads to ensure minimum vibration as recommended by manufacturer including provision of PCC foundation above ground level as per manufacturer’s drawing/instructions.
( E) Batteries maintenance free of suitable size and numbers as per recommendations of manufacturer along with the connecting leads and battery stand.
(F) Acoustic enclosure with natural air circulation without loss of any power for ventilatin fan. The enclosure shall be modular in costruction with hinge.
-
-
-
(G) AMF (Automatic Main Failure) :- AMF (Automatic Main Failure) panel duly fixed outside the canopy of DG set of suitable size out door, Cubicle type, factory fabricated out of MS CRCA Sheet of 3.15 mm thick dust, vermin proof, weather proof, IP-54 Grade of protection, fabricated on 50x50x5 mm thick MS angle iron frame both side opening and locking arrangement including providing Aluminium bus bar of capacity , 160 Amps rating for 415 V 50 Hz 3 Phase system including interconnection with multistranded conductor/Strips/Wires/Cables with hot shrink color coded sleeves with RYB colours and suitable adopter boxes with spreader links for connecting cables with switch terminals (Where necessary) complete as per OEM Recommendation.The AMF panel shall comprise the following assessories.
INCOMING
(a) MCCB 160 Amps 4 pole 16 KA -01(Output from DG i.e Incoming to AMF Panel)
(b) MCCB 160 Amps 4 pole 16 ka-01(Main supply)
Note : (i) Connection of incoming and out going cables and complete wiring of LT switch gears with pre insulated copper conductor of suitable size by using copper thimbles testing and commissioning complete. (ii) Cost of PCC foundation as per OEM's recommendation & all other fixing accessories shall be deemed to be inclusive in quoted rate.
-
-
-
EXTERNAL WATER SUPPLY
-
-
-
Supply,fixing & Laying Ductile iron Pressure pipes 150 mm bore with socket & spigot end class K-9 conforming to IS 8329/2000 suitable for (push on), including rubber gasket joint with inside cement morter lining and out side zinc coating with finished layer of synthetic resin(Blue Epoxy) including fittings such as Tees, bends, elbows etc, in any length and laid in trenches complete all as specified and directed.
210
-
-
Supply,fixing& Laying Ductile iron Pressure pipes 100 mm bore with socket & spigot end class K-9 conforming to IS 8329/2000 suitable for (push on), including rubber gasket joint with inside cement morter lining and out side zinc coating with finished layer of synthetic resin(Blue Epoxy) including fittings such as Tees, bends, elbows etc, in any length and laid in trenches, complete all as specified and directed.
30
-
-
M&L for Cutting//taping the existing cast iron pipes of 150/100/80mm bore in position and reducing to required length for insertion of new tee 150X150X100mm, branches including jointing with lead etc complete all as specified and directed.
5
-
-
M&L for construction of valve chamber of size 900x900x900mm internal size suitable for valves with PCC 1:4:8 type D2 for foundation and brick masonry wall in cement mortar 1:6 PCC 1:3:6 type C 1 for coping rendering in CM 1:4,15mm thick including Provn of mild steel sheet cover 3.15mm thick on 40x40xx6mm angle iron frame work and opening handle with two coats of synthetic enamel black paint over a coat of red oxide primer and locking arrangement including necessary excavation,retunning, filling etc,complete all as specified and directed.
5
-
-
M&L for construction of valve chamber of size 1200x1200x1200mm internal size suitable for valves with PCC 1:4:8 type D 2 for foundation and brick masonry wall in cement mortar 1:6 PCC 1:3:6 type C 1 for coping rendering in CM 1:4,15mm thick including Provn of mild steel sheet cover 3.15mm thick on 40x40xx6mm angle iron frame work and opening handle with two coats of synthetic enamel black paint over a coat of red oxide primer and locking arrangement including necessary excavation,retunning, filling etc complete all as specified and directed.
3
-
-
EXTERNAL ELECTRIC SUPPLY
-
-
-
Supply,install, test and commission of LT Panel of suitable size, outdoor, Cubicle type, factory fabricated out of MS Sheet of 3.15 mm thick dust, vermin proof, weather proof, IP-54 Grade of protection, fabricated on 50x50x5 mm thick MS angle iron frame both side opening and locking arrangement including providing aluminium bus bar of capacity 300 Amps rating for 415 V 50 Hz 3 Phase system including interconnection with Solid conductor/Strips /Wires/Cables with hot shrink color coded sleeves with RYB colours and suitable adopter boxes with spreader links for connecting cables with switch terminals(where neccessary), complete with following:- (03 For ORs and 01 for JCO block)
INCOMING
(a) MCCB 160 Amps 4 pole Icu=Ics=Icw=16 KA -01 Nos
(b) Digital Voltmeter 0-500 volt with selector switch suitable for 3Ph, 50 Hz,415 V with accuracy class CL-0.5- 01 Nos-01
(c) Digital Amperemeter 0-400 Amp with CT & selector switch suitable for 3Ph, 50 Hz, 415 V with accuracy class CL-0.5- 01 Nos-01
(d)LED indicator set, Selector switch-01 set
OUT GOING
(a) MCCB 63 Amps 4 pole ,Icu=Ics=Icw=16 KA -05 Nos
4
-
-
Supply , install, test & commission of LT Panel of suitable size,Outdoor Cubicle type, factory fabricated out of MS Sheet of 3.15mm thick dust, vermin proof, weather proof, IP-54 Grade of protection, fabricated on 50x50x5 mm thick MS angle iron frame both side opening and locking arrangement including providing Aluminium bus bar of capacity 300 Amps rating for 415 V 50 Hz 3 Phase system including interconnection with solid conductor/Strips/Wires/Copper Cables with hot shrink color coded sleeves with RYB colours and suitable adopter boxes with spreader links for connecting cables with switch terminals(where neccessary),complete with following:- (For ORs Lift)
INCOMING
(a) MCCB 1600 Amps 4 pole, Icu=Ics=Icw=16 KA.
(b) Digital Voltmeter 0-500 volt with selector switch suitable for 3Ph, 50 Hz,415 V with accuracy class CL-0.5- 01 Nos-01
(c) Digital Amperemeter 0-400 Amp with CT & selector switch suitable for 3Ph, 50 Hz, 415 V with accuracy class CL-0.5- 01 Nos-01
(d)LED indicator set, Selector switch-01 set
OUT GOING
(a ) MCCB 63 Amps 4 pole, Icu=Ics=Icw=16 K-06 Nos
1
-
-
Supply,install, test and commission of LT Panel of suitable size, outdoor, Cubicle type, factory fabricated out of MS Sheet of 3.15 mm thick dust, vermin proof, weather proof, IP-54 Grade of protection, fabricated on 50x50x5 mm thick MS angle iron frame both side opening and locking arrangement including providing Copper bus bar of capacity 300 Amps rating for 415 V 50 Hz 3 Phase system including interconnection with Solid conductor/Strips/Wires/Cables with hot shrink color coded sleeves with RYB colours and suitable adopter boxes with spreader links for connecting cables with switch terminals(where neccessary),complete with following:- (For JCO block Lift & Main DG Panel)
INCOMING
(a) MCCB 160 Amps 4 pole Icu=Ics=Icw=16 KA -01 Nos
(b) Digital Voltmeter 0-500 volt with selector switch suitable for 3Ph, 50 Hz,415 V with accuracy class CL-0.5- 01 Nos-01
(c) Digital Amperemeter 0-400 Amp with CT & selector switch suitable for 3Ph, 50 Hz, 415 V with accuracy class CL-0.5- 01 Nos-01
(d)LED indicator set, Selector switch-01 set
OUT GOING
(a) MCCB 63 Amps 4 pole ,Icu=Ics=Icw=16 KA -03 Nos
2
-
-
Refixing & installation only of existing prepaid 1 phase, 2 wire single source energy meters retreived from demolition of building under this job, complete all as specified and directed.
28
-
-
Supply, installing, testing and commissioning of 1 phase, 2 wire, single source, pre-paid smart energy meters confirming to IS 16444 having current range 10-60 Amps, complete all as specified and directed.
28
-
-
Design, manufacturing, supplying and installation in correct aligned position making proper connecting testing and commissiong of energy meter panel for accomodation for 07 nos meter suitable for 415V, 4 wire 50 Hz in distribution system. Panel should be indoor IP-42 rating free standing, floor mounted sheet ,metal clad cubicallly dust and vermin proof type compact design fabricate of 2mm CRCA sheet steel complete adequate size of incoming and outgoinfg feeder cable alloy proper locking arrangement transparent glass for checking of reading, painting with two coats of synthetic enamel paint over a coat of red oxide primer coat, earthing numbering, danger plate including necessary earthing and PCC work for erection of panel, complete all as specified and directed.: and as follows-
(i) Aluminium bus bar Nos 4 pole, 200 Amp capacity
(ii)Incoming MCCB 63 Amp 4 pole 16KA-01 No
(iii) MCB SPN 32 AMp 230 V 10 kA-07 Nos
(iv)MCB SPN 10 AMp 230 V, 10 KA-01 No
(v) Internal wiring with 6sqmm PVC insulated unsheathed multistranded copper conductor
(vi)Voltmeter 500 Volts, Amp meter 0-200 Amps and LED Indicator Lamp complete.
8
-
-
DEMOLITION AND DISMANTLING
-
-
-
Taking down flushing cistern and flush pipe of any description/capacity, complete all as specified and directed.
32
-
-
Taking down wash basins vitreous china of any size including brackets, complete all as specified and directed.
32
-
-
Taking down of old unserviceable bib taps of 15mm bore complete all as specified and directed.
144
-
-
Taking down of old unserviceable stop/angle valve of 15mm bore complete all as specified and directed.
64
-
-
Taking down of the old perished Meter Board & DBs,MCBs any type by necessary cutting, chasses including disconnection of incoming and out going cable etc compete all as specified and directed.
37
-
-
Disconnecting and taking down unserviceable service connection / cable of any size from pole/main switch board complete all as specified and directed.
200
-
-
Taking out carefully earthing set complete of any type including earthing wire/strip complete all as specified and directed.
7
-
-
ARBORICULTURE
-
-
-
Supplying and planting below mentioned best quality grown trees of 8-10 ft height plants at site including transportation of plants, pit digging 0.9mX0.9mX0.9m in ordinary soil, including HEDGE around trees and refilling the same with excavated soil mixed with manure, fertilizers and chemicals as may require and removal of remaining soil to a distance not exceeding 50 metres and lift upto 1.5m, complete all as specifieed and directed.
-
-
-
ALSTONIA SCHOLARIS(BLACK BOARD TREE)
3
-
-
LAGERSTROEMIA SPECIOSA(JARUL)
6
-
-
AZADIRACHTA INDICA(NEEM)
6
-
-
MIMUSOPS ELENGI(MAULSARI)
4
-
-
ALSTONIA MACROPHYLLA (DEVIL TREE)
2
-
-
PLUMERIA OBTUSA (CHAMPA)
22
-
-
DELONIX REGIA (GULMOHAR)
5
-
-
Complete maintenance of new plant/trees for complete 12 months lsuch as making of basin at regular interval, watering, weeding application, manuering and fertilizer application etc, complete all as specified and directed.
(Note: If any plant /tree found dead during this period shall be replaced)
48
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%