Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date7 Oct 2024
Closing Date28 Oct 2024
Tender Amount₹ 45,74,000
Costs
EMD
₹ 91,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_671700_1Bid Award Id
ViewTender No
GE/SW-57/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
One ceiling/exhaust/wall fan point controlled by one switch.
5
-
-
One socket outlet 5 amps on the same board with other switches with cables 1.5 sq.mm size.
5
-
-
One socket outlet 5 Amps controlled by one switch on independent board with cables 1.5 sq.mm size.
8
-
-
M&L for point wiring surface type with 2.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLSH copper conductor cable including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, GI metal flush box of 1.60 mm thick or surface mounting plastic/ PVC box for 1 Nos 3 pin, 6/16 Amps socket outlet independent board complete with cover plates (modular/ conventional type as required), blanking plates, brass screws, cup washers etc including all cutting/ chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and as directed.
18
-
-
All description as per srl item No 3 here- in- before but wiring with 4 sq mm PVC insulated multi-stranded copper conductor for industrial socket outlet 3 pin 16 / 20 Amps point and one single core 4 sqm mm PVC insulated unsheathed copper cable as earth continuity conductor.
2
-
-
M&L for point wiring in existing conduit with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into existing rigid non-metallic conduit of 20mm dia or higher, GI metal flush box of 1.60 mm thick or surface mounting plastic/ PVC box suitable for modular/conventional switches/ sockets/ fan regulators with cover plates (modular/ conventional type as required), blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings:-
-
-
-
One light point controlled by one switch
4
-
-
One ceiling/ exhaust fan point controlled by one switch
4
-
-
One socket outlet 5 Amps controlled by one switch on same board
6
-
-
One socket outlet 5 Amps controlled by one switch on independent board
6
-
-
All as per serial item No 5 above but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 16 Amps socket outlet point on independent board with 2.5 Sqmm nominal cross sectional area copper conductor cable as continuous earth wire.
14
-
-
S&F in replacement of modular white cover plate and with frame 6 module suitable for fixing of modular switches/sockets complete all as specified and directed.
20
-
-
S&F in replacement of modular white plate and cover suitable for fixing of modular switches/ sockets, 3 modules complete all as specified and directed.
20
-
-
S&F in replacement of PVC Non metallic conduit of external dia 20 mm medium grade including of all tees, bends elbow, reducers bell mouth tube end and fixing accessories such as coupler, lock nuts, saddles, pipe hooks etc but exclusive of junction boxes complete all as specified and directed.
80
-
-
All as per Srl item No 09 here-in-before but 25 mm dia.
80
-
-
S&F in replacement of PVC box suitable for fixing of modular Switches/ sockets of 3 modules complete all as specified and directed.
20
-
-
S&F in replacement of PVC box suitable for fixing of modular Switches/ sockets of 6 modules complete all as specified and directed.
20
-
-
S&F in replacement of modular white plate and cover suitable for fixing of modular switches/ sockets, 2 modules complete all as specified and directed.
65
-
-
S&F in replacement of energy efficient LED round (dia as per site requirement) or square shape (6inch x 6 inch), recess/surface mounted downlight fitting 15 Watt, 140V-270V, 3000 K to 6500 K couler temp, white powder coated, aluminium heat sink with efficacy of ≥140 lm/W, symmetrical light distribution, powered by an independent, isolated, SELV output electronic driver, snap fixed on the fixture, pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire as per existing at site complete all as specified and as directed.
4
-
-
All as per srl item no 14 but LED 18 watt round shape recess mounted as per site requirement complete all as specified and as directed.
4
-
-
All as per srl item no 14 but LED 10 watt round shape recess mounted as per site requirement complete all as specified and as directed.
2
-
-
All as per srl item no 14 but LED 5/6 watt round shape recess mounted as per site requirement complete all as specified and as directed.
2
-
-
All as per srl item no 14 but LED 2/3 watt round shape recess/ surface mounted as per site requirement complete all as specified and as directed.
4
-
-
S&F in replacement LED energy efficient flood light of 100 watt, 230 volt, anti glare diffuser, IP-65 incl connection complete all as specified & directed. (Make- Havells Cat Part No :- JETAADORNFLS100WLED757SSYMTOTG or equivalent model of the make as per PS.)
7
-
-
Supply only high grade drywall gypsum screw 3.5 to 4.2 mm dia upto 65 mm long, metalic finish, black color, fully threaded complete all as specified and directed.
7
-
-
Supply only high grade GI Saddle with base complete upto 25 mm dia conduit pipe complete all as specified and directed.
20
-
-
Repair, preventive and periodical maintenance, testing and commisioning of DG Set 1010 KVA , Make- Perkins, ESN-DGBH6037-U17270X, U17272X, U17269X, installed in main substation (NBC) including servicing and replacement of unserviceable parts etc complete all as specified and as directed.
Notes: (i) Spare parts shall be measured and paid sepretaly as "Supply only" under respective item of this Schedule. All the spare part of DG set 24.01 to 24.05 shall be bought through respective OEM (i.e. Perkins) or their authorised dealer and fitted through OEM's engineer only.
(ii)Fixing charges of Materials of item no 24.01 to 24.05 is included in the quoted rate of item no 23.
(iii) After repair/ replacement of spare parts, caliberation of all the system should be done accordingly as before.
(iv) The contractor shall immediatly attend break down on short notice as & when required with T&P and transport on receipt of information in required to breakdown on the direction of Engr-in-Charge. (v) In case contractor fails to attend and rectify the fault in 24 hr after intimation by department, he shall be liable to bear the recovery @ Rs 1000 /- per hour after intimation of 24 hrs and department shall rectify the fault through other agency on contractor risk and cost and double amount should be recovered from contractor dues.
1
-
-
Supply only in replacement following Spare parts of DG Set of capacity 1010 KVA (Make : Perkins) installed in main substation (NBC) complete all as specified and as directed:-
-
-
-
Bellow cat part no LCL/Bellow/4000
1
-
-
Washer cat part no 277/124
6
-
-
Seal O ring cat part no 576/137
12
-
-
Injector cat part no T402742
6
-
-
Current Transformer CT CL-1, 15VA, 3500/5A
1
-
-
Taking down and supply and fixing in replacement of steel tube medium grade galvanized in any length with all fittings laid in trenches complete and all as specified the following sizes:-
-
-
-
a) 80 mm bore
180
-
-
b) 50 mm bore
100
-
-
c) 40 mm bore
50
-
-
Supply and fixing in replacement CPVC pipe including fittings in any length with all fittings laid in trenches/bore/wall complete and all as specified of following sizes:-
-
-
-
(a) 50 mm bore
24
-
-
(b) 40 mm bore
24
-
-
M&L cleaning of existing CI/GI water main line upto 80 mm bore inside trench/wall/floor /roof area by removal of scale/blockage mud or any other materials inside from pipe by maually or mechanically as required as per site condition after cleaning relaying, jointing and testing of same in in position after cleaning complete for the following sizes:- (Note- Any extra jointing materials if required at site, shall be included in the quoted rate):-
200
-
-
Repair of sluice valve 80 mm dia in position double flanged cast iron for repair, replacement of unserviceable components such as of bonnet, gland packing, seat, disk gasket nut bolts and spindal with nut after repair grending, resurfacing refixing the valve in position and testing all as specified and dircted by Engr-in-Charge of following sizes:-
2
-
-
Supply and fixing in replacement of sluice valve 80 mm dia type PN-1.6 double Flanged cast iron type with brass spindle and iron wheel iron nuts, bolts & washers and rubber insertion sheet conforming to IS specification complete and all as specified dismentling old unserviceable valve as following sizes:-
2
-
-
Supply and fixing in replacement of gun metal gate valve with iron wheel head screwed both ends for GI pipe complete and all as specified and dismantling old valve of following sizes:-
-
-
-
a) 50 mm bore
6
-
-
b) 40 mm bore
5
-
-
c) 25 mm bore
4
-
-
d) 20 mm bore
5
-
-
Material and labour in repair of mild steel plates (plain or chequered) of 5mm thick or over in thickness in available sizes Fe-290 (Gde E-165) complete all as specified and directed.
200
-
-
Dismantling and taking out pump motor of 10 HP capacity (Make - Kirlosker/CG) transporting to work shop opening the motor, removing burnt winding and cleaning to starter slots and rewinding of motor using copper winding wire of suitable gauge/ size supper enamelled winding wire, replacing insulating paper of class F and fire proof sleeves, varnishing complete, oiling, greasing, replacing old rear/ front bearings motor crank set, shaft seal assembly, rubber gasket, nut, bolt & washers and re-fixing it in original position including testing at site on full load all as directed by Engr-in-Charge.
1
-
-
All as per item No 32 above but for motor pump set up to 7.5 HP motor pump set.
1
-
-
Dismantling the coupling and taking out 10 HP pump set (Make- Kirosker) and transport to work shop including opening the pump, servicing of impeller replacement unserviceable bearing and bushes and worn out nut and bolts gaskets, machining of shafts, over hauling & greasing of pump and reassembling complete with existing motor at site testing on full load all as specified and directed by Engr-in-Charge.
1
-
-
All as per item No 34 above but for motor pump set up to 7.5 HP motor pump set (Make- Kirlosker)
1
-
-
Disconnecting electric connection lifting/ taking out unserviceable submersible pump set 7.5 HP capacity complete from bore well disconnecting of motor and pump assembly transporting pump set to workshop, opening the motor, removing burnt winding and cleaning sleeves and rewinding of motor using new super enameled copper winding wire of suitable gauge / size, replacing paper insulating fire proof sleeves, varnishing etc. opening of pump impeller for necessary repair work such as grinding reallignment replacement of unserviceable thrust bearings, bushes shaft seal assembly complete pump and motor after repairing lowering in existing position all as specified and directed.
1
-
-
All as per item No 36 above but for motor pump set up to 5 HP motor pump set.
1
-
-
M&L replacement of submersible pump set of 5 HP (3.7 KW) 3 phase 415 volt minimum flow rate 475 LPM 5 stage from existing borewell of depth up to 35 mtr all as specified and directed by Engr-in-Charge. (Note- T&P required for replacement of pump including lifting lowering shall be catered for under scope of work.)
1
-
-
Material & Labour for replacement of stainless steel wire rope (ss-304) size 8 mm dia with 2 nos holding clamps suitable for hanging of submersible pump complete all as directed.
30
-
-
Material & Labour for replacement of base frame of cetrifugal pump set 10/ 7.5 HP pump set made out of MS channel MC 100/ 75 including necessary fabrication of channel to match with existing frame in size & shape incl cutting, welding, grinding and civil work for grouting with PCC 1:2:4 and dismantling & taking down pump set and re-fixing the same on new base frame complete all as directed.
4
-
-
Supply and fix in repair 3 pole power contactor MNX 25 AC-1 rating 25 A and AC 3 rating 25 A three phase, AC 440 volts, 50Hz.
2
-
-
Supply and fix in repair ST timer 100 range 3-30 Sec coil voltage 160-415 Volt AC. (Make - L&T equivalent rating on other make)
2
-
-
Supply and fix in repair thermal overhead relay MN-2 with start and off/reset of Amps range Relay 24-40 A 415V AC Class.
2
-
-
M&L for replacement of submersible cable round/flat of 3 core 6 Sqmm with multistanded copper coundecter all as directed.
80
-
-
Devlopment of borewell for submersible pump up to 7.5 HP capacity in accordance with standard Engineer practice to establish maximum rate usable water yield without sand content (Beyond the permisible limit) with required capacity air compressor, running the compressor required time till well is fully devloped. (Note:- T&P required for devlopment job shall be arranged by the contractor as per site requirement and same shall be included in the quoted rate)
24
-
-
M&L for cleaning of under ground sump /roof stage tank/ ground stage storage tank by dewatering complete by pumping motor set or manually and removing sludg/mud settled at bottom, scrapping of floor/wall internally by wire brush and washing floor and wall with diluted Sulphuric Acid to remove the alage thoroughly and clean till surface is clean in all respect and throwing out the sludge/mud muddy material along with foreign material from inside to outside where directed. After cleaning the reservoir completely, wash the surface of the wall with lime solution/Alum water with two coats and dried up with Anti baterial spay and ultra voilet radiation treatment etc i.e. complete in all respect including writting letters or figures for date of cleaning and capacity of tank wit synthetic enamel paint black background & letter /numbers in white colour & words size is 10 cm height on tank complete to the entire satisfaction of Engr-in-Charge and all as specified for the following capacity of tanks:-
Note: Contractor shall be arrange necessary T&P required for execution of work as per ground on such a way that to avoid hampering of water supply to user and same will be done as per instruction & as directed by Engr-in-Charge.
-
-
-
a) Under ground RCC sump with water storage capacity up to 50000 Gallon
3
-
-
b) Roof stage water tank made out of fiber board of capacity up to 12000 Gallons
8
-
-
c) Roof/ground stage water tank made out of fiber board of capacity up to 25000 Gallons
1
-
-
Repair / find out leakages of GI pipe line up to 80 mm bore and repair jointing complete including necessary exavation, returning filling, removing etc in any type of soil all as directed by Engr-in-Charge. Note:- T&P and fittings if required shall be inclusive in qouted rate.
8
-
-
Potability Testing of water sample by collecting water sample in clean bottle from borewell/ UG sump/service tank and getting Chemical, Boilogical, potable test (as per IS 10500:2012) at Govt recognised/ approved institute/ Lab for potability and chemical analysis complete all as specified & directed.
6
-
-
Supply only bleaching powder Calcium Hypochloride minimum 32% cholorine as per IS-1065:1989 in 25 Kg Bag. (Note:- Fresh lot of bleaching powder shall be supplied with in 45 Days from date of manufacturing as per monthy demand or as directed)
10
-
-
Repair and maintenance of industrial type RO plant of capacity 1000 LPH - 2 Nos through authorised dealer of OEM by checking, servicing, preventive/periodical, routine & corrective (break down) maintenance, cleaning, inspection and testing and including repair/ replacement of defective components /parts /accessories by the authorised peronnel of OEM. Notes: The term of maintenence includes chemical cleaning of RO membrane (4 Nos) once in three months or as directed by EIC to free the membrane from deposits, bacteriological growth and any from the scaling (Once in 6 months) replacement of filter eliments as per under mentioned qty. cleaning of installations repair and maintenance of allied pump/motors, valves and repair/ servicing of electrical accessories as per direction of Engr-in-Charge.
M&L replacement of following accessories/spares of RO plants:-
2
-
-
(i) Activated carbon pre-filter media (App : 275 Kg) of existing pressure vessel
2
-
-
(ii) Big blue housing cartridge for 20" filter housing
12
-
-
(iii) Thin film composite membrane (TW – 40-40) (Make: LG/Blue cell)
8
-
-
(iv) Anti-Scalant chemical Make: Microchem / DOW / Ge)
10
-
-
(v) Chemical PH correction chemical (Make : Microchem /DOW/GE)
10
-
-
M&L for replacement of filter media of pressure type softner plant of 1000 kg (Make- Aquapure ) with suitable size of filter media viz Rasin (Make- Ion Exchange/ Doshion), quatz send, and pebbles by disconnecting of inlet and outlet water connection opening of top/side cover of main vessele removing old filter media any type and supply and refilling new filter media as per manufacturer instruction basis after filling painting with two coat of anti corrosive super enameled paint, testing all as specified and directed.
(Note- T&P required for replacement of filter media as per site requirement shall be deemed to be included in the quoted rate)
1
-
-
M&L for replacement of filter media of pressure type softner plant of 500 kg (Make- Aquapure) with suitable size of filter media viz Rasin (Make- Ion Exchange/ doshion), quatz send, and pebbles by disconnecting of inlet and outlet water connection opening of top/side cover of main vessele removing old filter media any type and supply and refilling new filter media as per manufacturer instruction basis after filling painting with two coat of anti corrosive super enameled paint with two coat, reassebling testing all as specified and directed.
1
-
-
M&L for replacement of filter media of multigraded raw water filtration plant of 1200 kg capacity with suitable size of filter media viz pabbles, quatz send, activated carbon by disconnecting of inlet and outlet water connection opening of top/side cover of main vessele removing old filter media any type and supply and refilling new filter media as per manufacturer instruction basis after filling painting with two coat of anti corrosive super enameled paint with two coat , reassebling testing all as specified and directed.
1
-
-
M&L repair and servicing of incinerator unit of capacity 10 Kg/Hr (Make- Maridi) by replacement of combution chamber with refactory line of main chamber through out with special castable refactory having high strength at high temperature for maintaining required tempreture all as specified and directed.
1
-
-
Supply fixing in replacement of heating element inside of main chamber of incinerator unit capacity 10 Kg/Hr (Make- Maridi) as per existing capacity to maintain desire tempreture all as specified and directed.
1
-
-
M&L in replacement of main ontrol panel of incinerator unit factory made (indoor type) fixed on wall/floor with suitable size of controlling componants viz main incommer and outgoing MCCB, contactor,relays timers with control wiring (as per pump rating) including necessary provision for incoming and outgoing cables all as specified and directed.
1
-
-
M&L for painting of incinerator unit capacity 10 Kg/Hr (Make- Maridi) outer body, ventury scrubber, ID fan, FD fan and inside the incinerator shed base frame including machinery parts by scrubing of existing surface for preparation of painting with two coat of high tempreture aluminium paint all as specified and directed by Engr in Charge.
1
-
-
Taking down of old motor and supply and fix in repair induction motor 3 HP single phase suitable for ID fan of incinerator unit complete all as specified and directed.
1
-
-
M&L repair of automatic operated Boom barrier (Make- Motwane, Model SECG1116R) by repair and replacement of faulty photocell, contactor and relay assembly repair and servicing of main driver motor all as specfied and as directed.
1
-
-
M&L for painting of street light pole of size 7.5 mtr including bracket, base plate and accessories with two coat of aluminium paint after preparation of existing surface all as specified and directed.
70
-
-
M&L for painting of post top lentren pole of size 3.0 mtr including base plate and accessories with two coat of aluminium paint after preparation of existing surface all as specified and directed.
90
-
-
S & F in replacement of pedestal fan PVC made 450 mm sweep 230 volts, five star rated complete all as specified and directed. (Make- Havells Cat part No FHSPCNSWHY16 or equivelent)
5
-
-
Supply only wall mounted fan, PVC Body complete with all standard accessories, 230 V, 400 mm sweep complete all as specified and directed.
10
-
-
Supply and fix electric operated fly trap machine (insect killer) single phase 230 volt 40 watt with hanging accessories all as specified and directed by Engr-in-Charge.
5
-
-
S & F in replacement MCB DB double door, SPN, 16 Way with 200 Amp Cu bus bar, suitable for Flush Mounting or Surface mounting, IP 43, IK-09 as per IEC 61439-3 complete all as specified and as directed.
6
-
-
S & F in replacement MCB DB double door, TPN 4 Way with 200 Amp Cu bus bar, suitable for Flush Mounting or Surface mounting, IP 43, IK-09 as per IEC 61439-3 complete all as specified and as directed.
3
-
-
Supply and fixing in replacement of MCB distrubution board vertical type 125 Amps double door type steel sheet flush mounting type factory fabricated, powder coated , degree of protection IP-42 detachable gland plate neutral link, earth link with copper bus bar houseing with one incommer MCCB, four pole of rating 125 amp and 24 outgoing ways (without MCBs) complete all as specified and directed.
1
-
-
Supply only LED Recess Mounted Type, 2 x 2 feet Luminarie with high brightness fittings LED, 36 Watt, White/Worm White, cast Aluminium housing, toughened glass, Silicon gasket 6500K high power LED with lens for uniform distribution and suitable for armstrong/grid ceiling, pre-wired and electric connection with suitable size stranded copper flexible PVC insulated wire including clamps and nut & bolts for fixing complete all as specified and directed. Make : Havells Cat Part No. LHEBAEP7IW1W036 or its equivalent model mentioned in PS.
30
-
-
S & F Thermal magnetic release 63 Amps, 4 Pole MCCB 415 Volts, 16 KA suitable for Isolation and Ics = 100% Icu including suitable size/capacity of Spreadr Links and Phase Separator on both side and nut-bolts and washers etc complete all as specified and directed.
3
-
-
S & F Thermal magnetic release 100 Amps, 4 Pole MCCB 415 Volts, 16 KA suitable for Isolation and Ics = 100% Icu including suitable size/capacity of Spreadr Links and Phase Separator on both side and nut-bolts and washers etc complete all as specified and directed.
2
-
-
S & F Thermal magnetic release 125 Amps, 4 Pole MCCB 415 Volts, 25 KA suitable for Isolation and Ics = 100% Icu including suitable size/capacity of Spreadr Links and Phase Separator on both side and nut-bolts and washers etc complete all as specified and directed.
3
-
-
S & F Thermal magnetic release 160 Amps, 4 Pole MCCB 415 Volts, 25 KA suitable for Isolation and Ics = 100% Icu including suitable size/capacity of Spreadr Links and Phase Separator on both side and nut-bolts and washers etc complete all as specified and directed.
4
-
-
Supply only Insulation tape roll 5mtr long for day to day use during attending electric complaints.
100
-
-
Supply of Hammer /Hilty type Drilling & Chiselling Machine, Electric Operated, 1-ph, 720 watt, 230 V, RPM - 1500 capacity with Reverse /Forward operation including a set of all sizes of drill bits as per sample given complete all as specified and directed. (Make- Bosch or equivelent)
2
-
-
S & F of PVC Flexible spiral conduit pipe of 25 mm dia complete all as specified and directed.
100
-
-
S & F in replacement of condenser 2.5 mfd including fixing of clamps with screws, Sleeves etc complete all as specified and as directed.
40
-
-
Supply only 12 Module, PVC box fixing on wall surface complete all as specified and directed.
25
-
-
Supply only 12 Module, modular face plate/cover plate suitable for fixing of modular Switches/ sockets complete all as specified and directed.
25
-
-
M&L in repair/ replacement of LT indoor panel board made of 2.0 mm thck MS sheet front openable with locking arrangment fixed on angle iron frame of 50x50x5mm (thick) including necessary incoming & outgoing cable connections, cable glands, thimbles of required sizes working on 440 Volt 3 phase, 50 HZ, AC supply suitable capacity aluminium bus bar and suitable provision for housing following items:-
(a) Aluminium bus bar for three phase with neutral of capacity 300 Amps - 01 Set
(b) MCCB 4 Pole 200 amps, 36 KA breaking capacity, 415 Volt as main incoming. - 01 No (L&T or equvilent) (c) MCB TPN 63 Amps 415 Volts, 16 KA, 'C' Curve as per IS/IEC 60898-1 2002, IP-20 - 06 No (L&T or equvilent) (d) MCB, TP 32 Amps, 415 Volts, 16 KA, 'C' Curve as per IS/IEC 60898-1 2002, IP-20 - 06 No (L&T or equvilent)
e) MCB SP 20 Amps 20 Amps, 240 Volts, 10 KA, 'C' Curve as per IS/IEC 60898-1 2002, IP-20 - 32 Nos (L&T or equvilent) (f) Volt meter digital type 0-500 V - One each Ameter digital type 0-125A -One each CTs - Set of three
1
-
-
Supply, installation, testing and commissioning in repair/ replacement of outdoor LT panel board fixed on angle iron frame of 50x50x5mm(thick) double door opening with locking arrangment, including necessary incoming & outgoing cable connections, cable glands, thimbles of required sizes working on 440 Volt 3 phase, 50 HZ, AC supply of 250 Amps capacity aluminium bus bar fully compartmentalised mounted on epoxy insulator, dust proof and vermin proof 3.15 mm thick CRCA sheet steel enclosure powder coated suitable and all as specified CPRI Approved and having the following items:-
1
-
-
Incoming:- (a) One No MCCB 250 Amp, 4 pole, Icu 36 KA (Ics=Icu) 415 volts, 50 Hz with microprocessor release (S1 type) adjustable between 40% to 100% against overload setting.
(b) BUS BAR:- 4 Nos (three for phase of rating 400 Amp and one for neutral of rating 250 Amps made of aluminium mounted on heavy duty rubberised/ porcelain support.
-
-
-
Outgoing:- (i) MCCB 4 Pole, 415 V, 160 Amps with breaking capacity 36 KA adjustable between 70% to 100%- 01 No (PHOTO LAB) (ii) MCCB 100 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 04 Nos. (BLDG DB)
(iii) MCCB 63 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 02 Nos.(BLDG DB)
(iii) MCCB 32 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 01 No. (PARKING LIGHT AND S/PUMP)
-
-
-
METERING
(a) Voltmeter upto (0-500 volt) digital type with selector switch -01 Set
(b) Ameter 0-300 A Digital type with reincast CT set of 3 & with in built phase selection- 01 Nos.
(c) Indicator lamp LED type (set of three) -01 Set
-
-
-
All as per item No 80 here in before but Panel No -2 (UPS panel near new bldg) with and including following accessories:-
1
-
-
Incoming:- (a) One No MCCB 250 Amp, 4 pole, Icu 36 KA (Ics=Icu) 415 volts, 50 Hz with microprocessor release (S1 type) adjustable between 40% to 100% against overload setting.
(b) BUS BAR:- 4 Nos (three for phase of rating 400 Amp and one for neutral of rating 250 Amps made of aluminium mounted on heavy duty rubberised/ porcelain support.
-
-
-
Outgoing:- (i) MCCB 160 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 01 No (Bldg DB)
(ii) MCCB 100 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 04 Nos. (BLDG DB)
(iii) MCCB 63 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 04 Nos. (BLDG DB)
-
-
-
METERING
(a) Voltmeter upto (0-500 volt) digital type with selector switch -01 Set
(b) Ameter 0-300 A Digital type with reincast CT set of 3 & with in built phase selection- 01 Nos
(c) Indicator lamp LED type (set of three) -01 Set
-
-
-
All as per item No 80 here in before but panel-3 (Near pond) with and including following accessories:-
1
-
-
Incoming:- (a) One No MCCB 400 Amp, 4 pole, Icu 36 KA (Ics=Icu) 415 volts, 50 Hz adjustable between 40% to 100% against overload setting.
(b) BUS BAR:- 4 Nos (three for phase of rating 600 Amp and one for neutral of rating 400 Amps made of aluminium mounted on heavy duty rubberised/ porcelain support.
-
-
-
Outgoing:- (i) MCCB 160 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 02 No (O/G for ITBP mess sub panel)
(ii) MCCB 100 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 03 Nos. (For submersible panel and fountain panel)
(iii) MCCB 63 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 02 Nos. (Car washing panels)
(iv) MCCB 32 amp, 4 pole, Icu 25 KA (Ics=Icu) 415 volts, 50 Hz thermally adjustable between 70% to 100%- 04 No. ( fountain lght & garden lights )
(v) MCB DP 16 Amps -06 Nos (post top lghts)
-
-
-
METERING
(a) Voltmeter upto (0-500 volt) digital type with selector switch -01 Set
(b) Ameter 0-300 A Digital type with reincast CT set of 3 & with in built phase selection- 01 Nos
(c) Indicator lamp LED type (set of three) - 01 Set
-
-
-
Street light Auto ON/ OFF system
(i) Time switch 415 volts, 3 phase of 32 Amp - 01 No.
(ii) Contactor 3 plole 415 volt, 32 Amp - 01 No.
(iii) MCB SP 16 Amp 10 KA - 02 No
(iv) Toggle switch 16 Amps - 01 No
(v) Neutral link copper - 01 No.
-
-
-