Military Engineer Services Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 2,20,600Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_693552_1Tender No
CWE (U)/D-21/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Sch 'A' Part-III (Internal Electric Supply) (Ref pre priced Schedule attached seperately)(B/F from Ser page No 27).
1
96339
-
... More
Sch 'A' Part-IV (Interlocking TIles) (Ref pre priced Schedule attached seperately)(B/F from Ser page No 28).
1
123645
-
... More
Sch 'A' Part-V (Culvert) (Ref pre priced Schedule attached seperately)(B/F from Ser page No 29).
1
255946
-
... More
Sch 'A' Part-VI (Shed) (Ref pre priced Schedule attached seperately)(B/F from Ser page No 31).
1
655547
-
... More
Total amount of Sch 'A' Part VII (Road) (Ref pre priced Schedule attached seperately) (B/F from Ser page No 34).
1
376291
-
... More
Total amount of Sch 'A' Part VIII (Fencing & Gate) (Ref pre priced Schedule attached seperately) (B/F from Ser page No 35).
1
134299
-
... More
SCHEDULE `A` PART-IX (Entry Gate Security System)
-
-
-
... More
Design,Supply ,installation,testing and commissoing of Boom Barrier of length 3.0 Meter length with outdoor application,height of boom from 875 mm ,housing thickenss 2.0mm , electro machanical drive unit,Microprocessor based control unit,boom dimensinon 90x32 mm, IP54 controller protecting rating ,230 V,50/60 HZ ,24 V motor power supply ,200 W Power and Opening/Closing Time - 2 to 6 Secs , 100% Duty cycle,- 20 degree C to +55 degree C operating temperature ,5 million cycle MCBF including necessary foundation/ fixing arrangements ,optical beam sensor ,access control operation, high range receiver,high range remote control,push button ,photosensor for human safety,loop detector, bar with protective rubber profile ,flash point , manual release key in case of power failure ,for better visibity shall be aluminium with red reflective strip and all connected accessories ,including necessary foundation as per OEM instructions complete all as specified and as directed. Note:- Civil Work and electric work for installation of above equipment will be scope of the Firm.
2
-
-
... More
Design, Supply ,installation,testing and commissoing of Electro hydraulically operated Tyre-Killer/ Axiel breaker ,length of the block 6 mtr Meter, width of the blocked driveway - 6000mm and installation depth 700 mm, height of spike in raised position - 450 mm, MTBF -500000 operation, load capacity upto 40 Ton, thickness of spike 20 mm,protection class-IP67, Rise/down time-3-5 Sec,blocking angle 60 degree,100% duty cycle, safety against vehicle/human- Loop dector and photo sensor should be provoded. remote control operation, with microprocessor beased control panel and manual operation in case of power failure with 04 cycle up and down movements and manual hand pump ,high level shock resistance and extremely sturdy, opening speed of 1 seconds ,operating temperature -20 degree C to 60 degree C, with foundation as per manufacturers instructions ,and provide to drainage system with pump set and finishing treatment to all steel element hot dib galvanised+spikes powder painted to red colour RAL3000 and traffic light complete The underground casing should consist of an all around closed sheet steel casing with concrete anchors. The solid blocking spikes are welded to the solid rotation axis in a distance of approx. 200 mm to each other. The axis should be connected with the hydraulic cylinder via a lever system necessary foundation as per OEM instructions all as specified and as directed. Note:- Civil Work and Elctrical work for installation of above equipment will be scope of the Firm.
1
-
-
... More
Design, Supply ,installation,testing and commissoing of Under Vehicle Scanning System (UVSS) 3D should produce two angular view high resolution 3D COLOR images of the complete underbody of any vehicle passing over it using dual Area-scan camera with ANPR and driver image camera complete based technology should be details given as below:- Scaneer/Processor unit Processor - Intel core I7 3.6 Ghz
Sensor- Progressive scan CCD/CMOS
RAM - 16 GB
Storage - 1 TB or more
Display image-18.5" or more
Operating system- window 10
video format- GIGE
Zoom Capability- 16X Scanner size minimum- 1250x 1000 mm
Load bearing capacity ( structure)- Upto 40 Ton
1
-
-
... More
Main Camera of the dual imaging cameras should be of high resolution Area-scan, GigE type with XGA resolution of (1920 x 1200) or above with specification as below
Camera Type - Gigabit Ethernet progressive camera
Sensor - CMOS XGA resolution (1920 x 1200) or better
Field of View - 155
Format - GiGE Vision compliant specifications
Composite Image resolution of the underside - 4 megapixel
Camera certification - CE
Camera casing ingress protection rating - IP 68, duly certified by NABL accredited lab for upto 24 hours of water proof .
scanning Speeed upto 0-30KMPH
-
-
-
... More
ANPR & Driver Cameras must have the following specifications:
Sensor type - CMOS XGA area sensor
Camera/Len Type- 2MP (varifical lens)
Camera Resolution- 1920 x 1080
Video format- H.264/MJPEG/H.265
focus distance- 10-40 Mtr
housing protection- IP67
Image Input- Still Image
(d) UVSS should be as per specification given as below........
The UVSS should be capable of handling vehicles moving at different speeds ranging from Zero (0) to 30 Km/hr, while the morphed composite images so captured by it should be automatically and dynamically adjusted according to the speed of the vehicle using multiple induction loop based sensors.
The UVSS must give output of all the data simultaneously i.e. the composite images, driver photos, vehicle’s frontal image and its number display – all should be displayed on the monitor (as per OEM recommandation) almost instantaneously after the vehicle cross the unit. Also, the system should have a facility to view the composite image, off-line also, for all vehicle .
-
-
-
... More
Srl No (d) ...........Contd...........
The UVSS should enable detection of suspicious objects that are hard to see via single view scanning systems, including visual access to cavities and niches, areas around suspensions, below the engine areas, side wall of fuel tanks & exhaust pipes etc.
The UVSS must have have high security feature to Immediately identifies any foreign object or modifications to the undercarriage by circling them with a RED RING and at the same time activates an audio alarm.
The UVSS must also provide a 3D image of the complete underside of any vehicle. Point zoom Comparison of both the images formed by the two area scan camera should be possible to see all the hidden areas .
The UVSS must have (scene) view camera, which can capture the complete scenic image & the traffic movement to keep track of vehicle before the vehicle is being scanned and the image of the same will be stored in database.
-
-
-
... More
Srl No (d) ...........Contd...........
The UVSS should also provide a feature to capture the image of the driver of all RHS driven vehicles, captured through a suitable driver view camera.
The system should have an Automated Number Plate Reading System (ANPRS) tuned to the Indian license plates, i.e. it should be able to automatically read and record a wide range of vehicle registration number plates’ alpha-numeric characters, written in English. Also, the frontal image view of the vehicle to be provided in the GUI, to facilitate manual viewing of the license plate image. in addition to that ANPR should be stand alone system and it must have its own software where all the captured images will be stored and can be cross verified with UVSS software.
The System shall have option to input certain vehicle registration number according to category like “wanted”, “suspicious”, “stolen”, “expired” etc by authorized personnel. On successful recognition of registration number the system shall generate automatic alarm. The vehicle categories shall be customizable.
-
-
-
... More
Srl No (d) ...........Contd...........
The UVSS shall have open protocol for integration with other security systems which will allow operator to give opening command to any other integrated barrier, bollard, tyre killer etc. if scanned vehicle is found OK. The UVSS system must have a facility to take back-up of all the transactions to storage media and must have the facility to generate report in excel, pdf and word format.
The UVSS unit should be compact and the underside illumination must be adequate and obtained through a dual array of long life, LED lighting modules.
The overall installed unit should be properly designed, and its structure should be able to withstand a vehicle axle-load up to 40-Tons at any point over the structure, so as not to suffer any accidental physical damage to the unit and the components under the pit cover should be in SS 304.
Underground cameras & lighting units of the UVSS must be enclosed in a suitable all-weather-proof housing of IP 68 equivalent or higher standard. provide to drainage system with sump pump to be provided to throw the drainage water accumulated in the sump pit for UVSS with all "civil work" shall be complete as per OEM recommandation.
Note:- All Civil Work and Elctrical work for installation of above equipment will be scope of the Firm.
-
-
-
... More
Design, Supply Installation, Testing Commissioning of Physical crash rated Electro Hydraulic Bollard set of 05 Fold , with min K12 Physical Crash Rating as per CTS / MIRA / KARCO Standard.
As per specification for Crash rated Bollord set of 05 fold as under mentioned...
Width of Block drive way - 6 Mtr
1)Blocking Height Min 1200 mm
2) bollard Diameter 355 mm
3)Number of blocking segments 05 Fold 4)Installation depth: 1350mm or as per manufutures standard
5)Drive Unit electro-hydraulic- PLC based
6)Electric motor capacity approx. 3 / 4 kW, 3-phase, 50/60 Hz,400 V
7)Protection class IP 55
8)Total weight 1500 kg approx.
9)Dimension of outdoor cabinet to be fixed to concrete plinth approx. 1200 x 800 x 300 mm (H x W x D)
10)Impact load 926kN, acc to PAS68/ASTM ( Should immobilize 7.5 ton vehicle crashing at a speed of 80 KMPH )
1
-
-
... More
11)Wheel load 100 kN vertically
12)Operation time Raising 6- 8 sec., lowering 5- 6 sec.
Hydraulic fluid Mineral or biodegradable fluid (RSL 22)
13)Operation temperature range - 40 / + 60°C
14) Power failure / emergency operation By integrated hydraulic hand pump
15) Electric controls inside outdoor cabinet - Glass-fiber reinforced cabinet, IP67
16) Hydraulic drive unit - Independent electro hydraulic power drive unit for set of bollards in separate weather- proof lockable protective housing for outdoor installation. Protection class at least IP55. Hydraulic power pack should be in a separate cabinet above the ground at a distance of approx. 15 mtrs (max) from the bollard and all the bollards should be operated simultaneously.
17) Hand pump - for manual or emergency operation in case of Power failure
Operation Automated Operation using “UP” & “Down” push button for standalone operation. The bollards shall be in operation- up or down; only till the push button is kept pressed condition. This ensures avoiding accidents due to carelessness of the operator there by ensuring additional safety and operator alertness during operation.
-
-
-
... More
18) Power failure operation - Hydraulic accumulator sufficient to cater to 4 full cycles (up + down ) automatically in case of power failure.
19) Emergency operation Speedy operation in case of emergency (bypassing normal operation )
20) Surface Protection / galvanizing procedure of Blocking Bollards: Long term corrosion protection by clean blasting of the surface as per SIS 055900, level Sa 3. This is followed by electrical arc galvanizing according to DIN 8565 and DIN 8566. The minimum thickness of the first galvanizing layer should be 100µ. Subsequently followed by two component power coating of 80 µ each. The total thickness of corrosion resistant layers should be min 260 µ.
21) Colour Standard- Colours according to RAL standard or as required.
-
-
-
... More
22) Drainage Provision:- Underground casing of each Blocking Bollard should have outlet at the lowest point of the casing for drainage purpose. An external sump pump to be provided to throw the drainage water accumulated in the soak / sump pit of the bollards near the drainage system.
23)Safety Loops / Sensors:- Two loop detections / Sensors should be provided for safety operation.
Led strips (blinking) to be provided with audio alarm during rising & lowering
24) Controllers: Should provide at least the following inputs and outputs (potential free).
Inputs Status - Outputs status
Open Opened Close Closed
Power monitoring Oil Level Phase monitoring Oil pressure , Temp Status 25) Standards:- The System should confirm to CE/UL or any other International Standard
-
-
-
... More
Physical Crash test Certification The Manufacturer should furnish physical crash test certificate in accordance with DOS or PAS 68/ ASTM Standards for impact resistance of 926 KN (7.5 ton vehicle crashing at a speed of 80 Kmph) from reputed premier agencies like MIRA / TRL/KARCO 26) Physical Crash Test certification submitted should match the product The crash test should be done on a SINGLE BOLLARD in actual field condition and not on set of 3 or 4 units. “Manufacturer’s declaration, computer simulations or static calculations of testing would not be considered valid”. Note:- Civil Work and Elctrical work for installation of above equipment will be scope of the Firm.
-
-
-
... More
Design, Supply Installation ,testing and commissioning of X-ray Baggage Scanner System with consist of X ray machine, Image acquisition, recording, storage and display system ,input/output roller, Servo voltage stabilizer of required capacity with combined test piece /test bag etc fabricated structure of steel frame to house the machine with mobile heavy casters and stable screw jack levelling feet and necessary steel structure to hose image acquisition, recording, storage and display system complete and must be included as per technical specification as below... 1. General Specification :-
a) Tunnel Opening – 600mm (W) X 400mm (H).
b) Power supply- 220V AC, 50HZ
c) Imaging - 3D Isometric
d) Color imaging – 3 Colors imaging based on atomic number and 6 colors imaging based on atomic number.
Ability to move between 3 colors and 6 colors during baggage scanning in real time.
e) Video display -22’’ high Resolution, Low Radiation, Ergonomic, LCD Color Monitor.
1
-
-
... More
f) Conveyor speed – 0.2m/Sec
g) Conveyor load – 180 Kg ( distributed load)
h) Storage temp - -20⁰C to 70⁰C
i) Operating temp - 0⁰C to 50⁰C j) Conveyor belt height- Range of 750mm and adjustable 100mm.
2. Image processing:-
a) Penetration - In steel 30mm guaranteed.
b) Wire Resolution- 40 AWG Wire Typical, 38 AWG Guaranteed
c) Contrast Sensitivity- 24 Visible Levels, 4096 Gray Levels
d) Beam Divergence- Beam Divergence: 74° diagonal vertically up-word.
e) Display Resolution- 1920 x 1280; 24 bit/pixel color.
f) Resolution and Penetration - Both resolution and penetration should be seen without press of a button.
g) Zoom – 2X to 64X step & step less Zoom.
h) Material Discrimination - Organic and inorganic material discrimination based on atomic number and density.
-
-
-
... More
3. Computer specification:-
a) Operating System - should be use latest Window operating system.
b) Processor- minimum i5 core, 3.0 GHz processor.
c) Memory - 8 GB RAM.
d) Storage Capacity- 1 TB HDD/SSD.
e) Key board & mouse - 01 No.
f) USB Port – 3.0 Supports 9 (04 Nos).
g) DVD/CD R/W
h) Video card - 2GB.
4. X-Ray Generator:-
a) Voltage -160 KV rating.
b) Cooling- Sealed Oil bath
c) Duty Cycle-100%
d) X ray detector- “L-shaped array
-
-
-
... More
5. Software features:-
a) The system shall also have multi energy system with four colour palette for material discrimination high, low, medium penetration. Thin object screening facility like razor blade, envelops etc.
b) Edge enhancement
i. Inverse video
ii. Black and white image
iii. Pseudo colour
iv. Bi-direction / scanning
v. NARCS can
vi Automatic image archiving c) The X-Ray Beam divergence should be such that the complete image of maximum size of bag is displayed without corner cuts with Edge-enhancement imaging.
d) Facility for variable contrast must be incorporated to allow enhancement of lighter and darker portion of the image. Facility of image enhancement and image gradient should be available.
e) Machine should be capable of recalling 100 previous images. It should have capability of archiving 50000 and more images.
-
-
-
... More
f) High Density Alert - Audio visual alarm and draw square around the object area where High density is found.
g) All software features of machine should be online, and password protected and should have PAN Option, Date and Time Display.
h) Threat image projection (TIP) should be available & Programmable.
i) Film Safety: Guaranteed up to ISO 1600 (33 DIN) and Maximum leakage radiation less than 0.1 mR/hr (1μ Sv/hr).
j) The systems should be food safety/ film safety / Radiation Safety and AERB/BARC certificate enclosed.
Note:- All Civil Work and Electrical work for installation of above equipment will be scope of the Firm.
-
-
-
... More
Supply installation testing and commissoning of Door Frame Metal detector (DFMD) 18 Zones with Microprocessor based, digitally controlled, Weatherproof with very low frequency pulse induction, LAN connectivity & Remote Operating Software complete as per technical specification as below.
1) Number Of Zones- 18 2) Sensitivity Leavl - 0-200
3) Power supply 90V to 240 V, 50/60Hz
4) Metal Alarm indication :- a. Visual: Alphanumeric display on the over head control unit. LED zones on left and right side of the DFMD showing height on person bar display (metal locator)
b. Audible: Audible tone alert for metal indication, with at least 5 selectable audio tones and audio intensities. 5) Detection capability- i. Uniform detection over the entire walk through area from top to bottom
ii. Should be capable to detect ferrous and non – ferrous metals including 9mm cartridge.
iii. Should be able to detect multiple metal objects of various sizes in different zones simultaneously
6) Calibration- Should have automatic Calibration /self installation for easy set up.
7) Sensitivity control- selectable membrane switch
1
-
-
... More
8) operating temperature - 10 to 55 degree celcius
9) Outer frame size - 2180mm (h)x 850mm (W)x 440mm (d)
10) Humidity- 95% non condensing
11) In case of power failture- Back up power Battery[12 V dc] back up for a minimum of 8 hours
12) Display unit - The display shall be equipped with alphanumeric display, keypad, including standby button, statusLEDs and audible indicator.
13) Health & safety:- i. Conform to relevant electric safety standard (supported by test certificate from NABL (India) accredited lab or by reputed labs from the country of origin of the equipment)
ii. Magnetic field should be harmless to magnetic media,electronic devices, wearers of pacemaker (heart) and pregnant women. Supporting test certificates from NABL (India) accredited lab or by reputed lab from the country of origin of the equipment should be attached.
14) Communication- RS 232/Infra-red/ Ethernet
15) IP rating - IP 55,
Make ;- Godrej / Brosis / Astrophysics / CEIA Note:- All Civil Work and Elctrical work for installation of above equipment will be scope of the Firm.
-
-
-
... More
Supply, Installation, Testing and Commissioning of UHF readers (02 nos.),2 Door Controller 1 no.with 100 cards and 01 no Computer system complete with ACS software all as specified and directed.
Make:- Honeywell / Brosis / HID /ID Cube
1
-
-
... More
Repair/replacement Sliding gate motors kit for the automation of sliding gates up to 400 kg , 24V DC, incorporated control unit with following accessories (a) RB 400,irreversible electromechanical gear motor-01 Nos (b)OXI, Reciver -01 Nos (c ) ON2E, Transmitter-01 Nos (d) MOFB, pair of photocell-01 Nos (e) MOSE, key selector -01 Nos (f) MLBT, Flashing Light-01 Nos.And along with repair of automatic industrial sliding door of size 4.9mx3.25m with alignment bottom & top track, replacement of gesket to ensure complete air tightenness along bottom, top and side wall, complete all as directed.
2
-
-
... More
Supply, installation, testing and commissioning of slient diesel engine driven generating set of capacity 30.0 KVA/ 24.0 KW, with AMF panel,415 Volt. 3 Phase, 4 Wire ,50 Hz, comprising of diesel engine alternator mounted and alinged on a comman base frame complete. Engine as per IS 10001/10002 and Alternator as per IS 13364 complete with relay panel and switch gear for automatic starting on main power failture ,Control panel having meter and sound proof canpoy as per CPCB-2 norms and foundation etc of rating 30.0 KVA/ 24.0 KW, power factor 0.8 (lagging) and connection as per IE rules complying CPCB/Govt norms of following OEMs:-
(a) POWERICA
(b) Cummins India Limited
(c) Kirloskar Oil Engines NOTE:-
(i) Complete DG set shall be procured directly from abobe mentioned OEMs
(II) The foundation shall be provided at site as per recommandation of manufactures design & drawing cost for the same is deemed to be included in unit rate of above items.
1
-
-
... More
M&L for Earthing of machinery /equipment installed for DG set, using 25 x 3 mm copper strip and copper plate of size 300X300X3mm as earth electode. ( for Neutral Earthing)- Set of 2 Eeathing counting as one Job
1
-
-
... More
M&L for Earthing of machinery /equipment installed for DG set, using 32 x 6 mm galvanised MS strip and MS Plate of size 600X600X6mm as earth electode. ( for Body Earthing) -Set of 2 Eeathing counting as one Job
1
-
-
... More
Supply, Installation, commissioning and testing of Inverter Technology Split Type wall mounted Air Conditioner cooling based (indoor & outdoor unit with cordless remote control unit) of capacity 1.5 Ton, BEE 5 star rating , fitted with rotary compressor Refrigerant type R-410A/R-32, including outdoor stand (Wall mounted/ Floor mounted), PVC FRLS grade multi stranded copper conductor cable 4 core 2.5 Sqmm for connections with outdoor unit, powder coated brackets/Chowki Stand for outdoor unit, clamps, nuts, bolts washers drilling holes on walls/ceiling for connection/drain pipes complete all as specified and directed. (Make:- Latest Model of Daikin/ O-General/Hitachi/ Blue Star.) Note:-(i) PVC drain pipes of suitable size & heavy duty Copper connection pipes including suitable insulation upto 3 Mtrs are deemed to be included in above quoted rate.
1
-
-
... More
Supply, Installation, testing and Commissioning of voltage stabilizer for automatic operation single phase, wall mounted ,Copper wounded ,Air cooled with digital display designed for input variation between 160 Volt to 260 Volt with output voltage 220 + 9% Volt with Calibration accuracy + 3% with high low cutoff , Intelligent time delay facility and of capacity 4.0 KVA. Make-Microtek/Volina/Sinetrac/V-Guard”
1
-
-
... More
SCHEDULE `A` PART-X (External Electric Supply)
-
-
-
... More
Supply, installation, testing and commissioning of powder coated outdoor type compartmentalized cubicle LT Feeder pillar box fabricated out of 3.15 mm thick CRCA sheet steel weather proof vermin proof and suitable for operation on 415 volts, 50Hz, 3 Phase 4 wire AC supply complete with gland plates, lifting hooks, ventilating louvers, bus bars, inter connections, earthing, labeling electrical interlocking, suitable for termination of cables including, supply and fixing of following switchgear and accessories in the panel. complete as required. The panel should be CPRI approved and having protection IP 65.
INCOMER :
1 no. 100 A, 415V, 36 KA, 4P MCCB with variable O/C, S/C & E/F Microprocessor based releases..
1 No. Digital type multifunction meter to show 0 - 500V, 0-100A, Kwh meter and set of cast resin C.T.'s of suitable ratio 1 set of Phase indicating lamp BUS BARS:
150 A TPN bus bars of aluminium alloy with epoxy based insulation.
1
-
-
... More
OUT GOING: MCCB TP 32 A, 18 KA ,415 volts AC - 03 Nos MCB DP 25 A , 16KA, 230 volts AC - 02 No MCB DP 20 A, 16 KA, 230 volts AC - 05 Nos
The foundation shall be provided at site as per recommandation of manufacturers design & drawing cost for the same is deemed to be included in unit rate of above item.
-
-
-
... More
M&L for Earthling complete with galvanised steel earth plate electrode 60cm x60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, including provision of galvanized earth strip 25 x4 mm connected by means of bolts nuts, checknuts and washers of galvanized iron or steel, provision of 40mm dia GI pipe medium grade for earth strip protection connected from earth plate electrode to main switch board, provision of 20mm dia GI pipe perforated medium grade for entering watering arrangement and PCC 1:3:6 type CI chamber, MS funnel, wire mesh, 50mm thick RCC 1:2:4 type B1 for earth pit cover with 6 Nos 8mm dia high strength deformed steel TMT bars on both ways, including necessary excavation in any type pf soil returning filling in, removal of surplus soil to a distance n.exc.50m, provision of charcoal and salt complete all as shown in electrical plate No3 of Schedule Part-I 2009 all as specified and directed and testing on completion.
Note : (i) Cost of GI earth strip and GI protection pipe upto 7.5 Mtr length shall abe deemed to be included in the rate quoted for this item.
6
-
-
... More
M&L for Earthling complete with galvanised steel earth plate electrode 60cm x60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, including provision of galvanized Iron wire 4.0mm dia connected by means of bolts nuts, checknuts and washers of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for earth wire protection connected from earth plate electrode to main switch board, provision of 20mm dia GI pipe perforated medium grade for watering entering arrangement and PCC 1:3:6 type CI chamber, MS funnel, wire mesh, 50mm thick RCC 1:2:4 type B1 for earth pit cover with 6 Nos 8mm dia high strength deformed steel TMT bars on both ways, including necessary excavation in any type pf soil returning filling in, removal of surplus soil to a distance n.exc.50m, provision of charcoal and salt complete all as shown in electrical plate No3 of Schedule Part-I 2009 all as specified and directed and testing on completion.
Note : (i) Cost of GI earth wire and GI protection pipe upto 7.5 Mtr length shall abe deemed to be included in the rate quoted for this item.
6
-
-
... More
Material&Labour,Earth continuity conductor or main earthing lead fixed to wall on batten or recessor chasesor buriedin ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc as required,25x4mm galvanised iron strip complete all as specified and as directed.
45
-
-
... More
Supplying laying or fixing or passing through pipe,ducts,pole laid in trench, road crossing,1100 volts grade XLPE insulated heavy duty electric cable size of 95 Sqmm 3.5 Core with standard aluminium conductor served with an inner shething of PVC tape armoured with GI wire and over all PVC sheathed in laid in trench/passing throughpipe/duct/road crossing/surface of wall/in hume pipe etc including fixing hardware clamps, making good the damaged surface etc complete all as specified and as directed.
Note:- Earthwork shall be measured and paid separately
120
-
-
... More
Supply and fixing post top lantern LED type 20watt 230 volts Ac outdoor type with decorative post top for 360 degree indirect light IP 65proctection with impact and corrosion resistant complete with driver and lamp complete all as specified .
Make:Crompton / Phillips /Havells / Bajaj
3
-
-
... More
Supply and fixing LED flood light 70 Watt 230 Volt AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified .
Make:Crompton / Phillips /Havells / Bajaj
2
-
-
... More
Supply and fixing LED 35 Watts Security light fitting along with 35 Watt LED, pressure die cast aluminium housing, heat resistant glass, IP 65 protection and mounted on suitable dia GI pipe bent and fixed on wall / poles using GI clamps, bolts, nuts and washers including provision of copper flexible cable 23/0.0076 twin twisted PVC insulated cable from ceiling rose to light fitting complete all as specified and directed Make:Crompton / Phillips /Havells / Bajaj
8
-
-
... More
Material and labour for Sub main wiring with two runs of single core 2.5 sq mm PVC insulated, unsheathed multistranded copper conductor 1100 volts FRLS cable, including one run of 2.5 sq mm single core PVC insulated unsheathed multistranded copper conductor 1100 volts FRLS cable as earth continuity conductor drawn through and including one run of rigid non metallic PVC conduit not less than 25mm external dia and conduit accessories etc., concealed in wall/floors /ceiling etc and connecting to common earth dolly complete all as specified and as directed.
Notes : (i) Three runs of 2.5 Sqmm cable and one run of rigid non metallic PVC conduit will be measured as one unit for payment purpose.
(ii) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
205
-
-
... More
M&L for Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation, for laying of pipes / cables / poles etc., or for shafts, wells,cesspits,manholes,pier holes etc not exceeding 10Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
24.3
-
-
... More
M&L for Returning, filling in trenches/ Back, filling of retaining walls with approved soil, including spreading, levelling, watering and well ramming in layers n.exc. 25cm complete all as specified and directed.
8.11
-
-
... More
M&L for Removing excavated soils to a distance not exceeding 50m and depositing where directed at level not exceeding 1.5m above the starting point complete all as specified and directed.
16.19
-
-
... More
Supply and laying un-reinforced precast concrete cable cover Class LV type-I, flat size 250mm X 150mm X 40mm in trenches for cable protection ,embossed with ELECTRIC on the top surface complete all as specified and directed.
600
-
-
... More
M&L Sand filling to the full width of trenches for protection of cables including spreading and punning down incuding watering and consolidation etc, complete al as specified and as directed. Note: Punned thickness only will be considered for payment.
7.29
-
-
... More
Supply and fixing MCCB FP 160 Amp, 36KA,415 Volts with fixed thermal and fixed magnetic setting type with suitable SS enclosure complete terminal links with thimbles, gland complete as specified and directed
Make- Havells/Legrand /HPL/ABB/L&T
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%